SEARCH · Search NASA
Results for “testing facility”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
National Solar Thermal Test Facility Control Room SolarPACES poster.
Abstract not provided.
LANL’s CARIE MeV photoinjector test facility
Explore the source record for details and available documents.
Optimization of a Monte Carlo Model of the Transient Reactor Test Facility
The ultimate goal of modeling and simulation is to obtain reasonable answers to problems that don't have representations which can be easily evaluated while minimizing the amount of computational resources. With the advances during the last twenty years of large scale computing centers, researchers have had the ability to create a multitude of tools to minimize the number of approximations necessary when modeling a system. The tremendous power of these centers requires the user to possess an immense amount of knowledge to optimize the models for accuracy and efficiency. Research reactors require that the neutron flux be well characterized so that the flux in a given location or the power delivered to the target in an experiment center can be accurately determined.
Enabling targeted TRISO transient analyses using the Transient Reactor Test Facility
Presentation
Comparison of Results between the Legacy and Refined RELAP5-3D Models of the High Temperature Test Facility in Exercises 1 and 2 of the HTTF Benchmark
Work conducted in FY23 identified that RELAP5-3D was capable of reproducing trends in HTTF data during experiment PG-27 but was incapable of reproducing measured values. The primary cause of this discrepancy between RELAP5-3D results and experimental data was hypothesized to be a distortion in power density that was introduced by the radial nodalization of the model. We further hypothesized that a new model would provide better results when compared to the experiments PG-27 and PG-29. Work this FY developed a new model that is better capable of capturing local heat generation rates and contains a representation of each 1/6 azimuthal sector of the core. We used this model to develop a new set of solutions to Exercises 1 and 2 of Problems 2 and 3 in the benchmark. In this report, we present the first comprehensive comparison of the results between the two models. We see that in Exercise 1A, which is common between problems 2 and 3, the results are similar, though the results from the new model show greater detail than those from the legacy model. In Problem 2 Exercise 1B and Problem 3 Exercise 1B, we see that heat removal is slower in the new model than the legacy model. Problem 3 Exercise 1C shows temperatures that are lower in most places in the new model than the legacy model, but the area with active heat generation has higher block temperatures in the new model than the legacy model. Problem 3 Exercise 1D further shows that long-term heat removal is lower in the new model. Problem 2 Exercise 1C demonstrated that the new model observes higher temperatures in the core regions than the legacy model, justifying the need to preserve the power density in HTTF. The validation of PG-27 and PG-29 also demonstrated the improved temperature agreement in the core regions, particularly with a calibrated model that implements an effective thermal conductivity for the core material. Overall, PG-27 models show reasonable to excellent agreement for steady-state temperatures and minimal to reasonable agreement for transients. PG-29 models showed minimal to insufficient agreement with the data.
Stability of CIS/CIGS Modules at the Outdoor Test Facility Over Two Decades (Presentation)
No abstract prepared.
Streamlined Approach for Environmental Restoration Plan for Corrective Action Unit 116: Area 25 Test Cell C Facility, Nevada Test Site, Nevada, Revision 1
This Streamlined Approach for Environmental Restoration (SAFER) Plan identifies the activities required for the closure of Corrective Action Unit (CAU) 116, Area 25 Test Cell C Facility. The Test Cell C (TCC) Facility is located in Area 25 of the Nevada Test Site (NTS) approximately 25 miles northwest of Mercury, Nevada (Figure 1). CAU 116 is currently listed in Appendix III of the Federal Facility Agreement and Consent Order (FFACO) of 1996 (as amended February 2008) and consists of two Corrective Action Sites (CASs): (1) CAS 25-23-20, Nuclear Furnace Piping; and (2) CAS 25-41-05, Test Cell C Facility. CAS 25-41-05 is described in the FFACO as the TCC Facility but actually includes Building 3210 and attached concrete shield wall only. CAU 116 will be closed by demolishing Building 3210, the attached concrete shield wall, and the nuclear furnace piping. In addition, as a best management practice (BMP), Building 3211 (moveable shed) will be demolished due to its close proximity to Building 3210. This will aid in demolition and disposal operations. Radiological surveys will be performed on the demolition debris to determine the proper disposal pathway. As much of the demolition debris as space allows will be placed into the Building 3210 basement structure. After filling to capacity with demolition debris, the basement structure will be mounded or capped and closed with administrative controls. Prior to beginning demolition activities and according to an approved Sampling and Analysis Plan (SAP), representative sampling of surface areas that are known, suspected, or have the potential to contain hazardous constituents such as lead or polychlorinated biphenyls (PCBs) will be performed throughout all buildings and structures. Sections 2.3.2, 4.2.2.2, 4.2.2.3, 4.3, and 6.2.6.1 address the methodologies employed that assure the solid debris placed in the basement structure will not contain contaminants of concern (COCs) above hazardous waste levels. The anticipated post-closure-posting requirements for the mounded/capped basement structure, as well as for the entire CAU, are addressed in Section 4.2.10. The site contains radiologically impacted surfaces and hazardous materials. Based on review of the historical information for CAU 116 and recent site inspections, there is sufficient process knowledge to close CAU 116 using the SAFER process. CAUs that may be closed using the SAFER process have conceptual corrective actions that are clearly identified. Consequently, corrective action alternatives can be chosen prior to completing a corrective action investigation, given anticipated investigation results. The SAFER process combines elements of the data quality objective (DQO) process and the observational approach to plan and conduct closure activities. The DQOs are used to identify the problem and define the type and quality of data needed to complete the investigation phase of the SAFER process. The purpose of the investigation phase is to verify the adequacy of existing information used to determine the chosen corrective action. The observational approach provides a framework for managing uncertainty during the planning and decision-making phases of the project. The SAFER process allows for technical decisions to be made based on information gathered during site visits, interviews, meetings, research, and a consensus of opinion by the decontamination and decommissioning (D&D) team members. Any uncertainties are addressed by documented assumptions that are verified by sampling and analysis, data evaluation, onsite observations, and contingency plans, as necessary. Closure activities may proceed simultaneously with site characterization as sufficient data are gathered to confirm or disprove the assumptions made during selection of the corrective action. If, at any time during the closure process, new information is discovered that indicates that closure activities should be revised, closure activities will be reevaluated as appropriate. Based on a detailed review of historical documentation, there is sufficient process knowledge to close CAU 116 using the SAFER process. The COC have been determined and are discussed in Section 4.1.
Wire Chambers and Cherenkov Detectors at Fermilab Test Beam Facility
Fermilab Test Beam Facility (FTBF) is dedicated to helping scientists test their prototypes. For this, FTBF has instrumentation that is very useful for the users. However, before a user can test a detector, it is necessary to ensure the facility has the characteristics they need. During this summer, we studied beam properties by collecting Cherenkov and wire chamber data. Analyzed data will be used for updating the general information that FTBF posts on a web page.
A Compton transmission polarimeter for DC and SRF electron photo-injectors
The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.
Searching for Low-Mass Dark Matter with SuperCDMS Soudan Detectors
SuperCDMS is a direct-detection dark matter (DM) experiment that uses cryogenically cooled germanium and silicon detectors to search for interac- tions between DM particles and detector nuclei, and in this thesis I describe my contributions to the experiment. I start with a brief review of DM and motivate the possibility of its de- tection in underground laboratories with sensitive detectors, and I review the SuperCDMS detector fundamentals. Then I focus on detector develop- ment for the future generation of the experiment, which will deploy an array of detectors at SNOLAB in Sudbury, Canada. Specifically I describe char- acterization of prototype detectors from surface facility testing, and discuss measurements of critical values that determine the detectors’ sensitivity to DM particles, such as the baseline resolution and the phonon collection ef- ficiency. I also describe analysis techniques developed to measure intrinsic detector noise in a high radiation environment such as a surface test facility. In the final chapters I describe a DM search analysis using four months of data from operation of SuperCDMS detectors in the Soudan Mine in northern Minnesota. I discuss how a particular detector operating mode, called CDMSlite, lowers the energy threshold of the detectors in order to improve the sensitivity to low-mass DM particles. I also present new analysis techniques that optimize the sensitivity to low-mass DM particles, including noise discrimination with multivariate classifiers, instrumental background modeling, and a profile likelihood signal and background fitting approach. In this analysis we set an upper limit on the DM-nucleon scattering cross section in germanium that is a factor of 2.5 improvement over the previous CDMSlite result for a DM mass that is five times the proton rest mass.
A Compton transmission polarimeter for DC and SRF electron photo-injectors
The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.
Analysis of Developing Gas/liquid Two-Phase Flows
The goal of this work is to develop a mechanistically based CFD model that can be used to simulate process equipment operating in the churn-turbulent regime. The simulations were performed using a state-of-the-art computational multiphase fluid dynamics code, NPHASE–CMFD [Antal et al,2000]. A complete four-field model, including the continuous liquid field and three dispersed gas fields representing bubbles of different sizes, was first carefully tested for numerical convergence and accuracy, and then used to reproduce the experimental results from the TOPFLOW test facility at Forschungszentrum Dresden-Rossendorf e.V. Institute of Safety Research [Prasser et al,2007]. Good progress has been made in simulating the churn-turbulent flows and comparison the NPHASE-CMFD simulations with TOPFLOW experimental data. The main objective of the paper is to demonstrate capability to predict the evolution of adiabatic churn-turbulent gas/liquid flows. The proposed modelling concept uses transport equations for the continuous liquid field and for dispersed bubble fields [Tselishcheva et al, 2009]. Along with closure laws based on interaction between bubbles and continuous liquid, the effect of height on air density has been included in the model. The figure below presents the developing flow results of the study, namely total void fraction at different axial locations along the TOPFLOW facility test section. The complete model description, as well as results of simulations and validation will be presented in the full paper.
Direct sunlight facility for testing and research in HCPV
A facility for testing different components for HCPV application has been developed in the framework of 'Fotovoltaico ad Alta Efficienza' (FAE) project funded by the Sicilian Regional Authority (PO FESR Sicilia 2007/2013 4.1.1.1). The testing facility is equipped with an heliostat providing a wide solar beam inside the lab, an optical bench for mounting and aligning the HCPV components, electronic equipments to characterize the I-V curves of multijunction cells operated up to 2000 suns, a system to circulate a fluid in the heat sink at controlled temperature and flow-rate, a data logging system with sensors to measure temperatures in several locations and fluid pressures at the inlet and outlet of the heat sink, and a climatic chamber with large test volume to test assembled HCPV modules.
Facility for high heat flux testing of irradiated fusion materials and components using infrared plasma arc lamps
A new high-heat flux testing facility using water-wall stabilized high-power high-pressure argon Plasma Arc Lamps (PALs) has been developed for fusion applications. It can handle irradiated plasma facing component materials and mock-up divertor components. Two PALs currently available at ORNL can provide maximum incident heat fluxes of 4.2 and 27 MW/m2 over a heated area of 9x12 and 1x10 cm2, respectively, which are fusion-prototypical steady state heat flux conditions. The facility will be described and the main differences between the photon-based high-heat flux testing facilities, such as PALs, and the e-beam and particle beam facilities more commonly used for fusion HHF testing are discussed. The components of the test chamber were designed to accommodate radiation safety and materials compatibility requirements posed by high-temperature exposure of low levels irradiated tungsten articles. Issues related to the operation and temperature measurements during testing are presented and discussed.
Commissioning and operation of the horizontal test apparatus at SNS
The Spallation Neutron Source (SNS) at Oak Ridge National Lab (ORNL) has built, commissioned and operated a Horizontal Test Apparatus (HTA) vessel in the Radiofrequency Test Facility (RFTF) test cave. It can be operated at 4.5 K using the independent Cryogenic Test Facility (CTF). The HTA is designed to be a single cavity version of an SNS cryomodule with the ability to demount and replace the cavity. It provides the functionality for testing a single dressed SNS medium or high beta Superconducting Radiofrequency (SRF) cavity. The HTA is currently being used in support of R&D for in-situ plasma processing of the cavity's inner niobium surface. The design and commissioning of the HTA at 4.5 K will be presented as well as results from operating the HTA including cool-down, warm-up and steady state operations. Results from plasma processing a warm SCRF cavity in-between cold HTA tests will also be reported.
Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage
The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.
Assessing Air Velocity Distribution in Three Sizes of Commercial Broiler Houses During Tunnel Ventilation
Abstract. Convective cooling is a critical management strategy for maintaining an environment that promotes production efficiency, thermal comfort, and animal well-being in commercial broiler houses. Variations in house size, design, and equipment configuration contribute greatly to the air velocity distribution within the facility. This study assessed total airflow, air velocity distribution, and quantified the floor area in three facilities experiencing insufficient air velocity for maintenance of production efficiency, thermal comfort, and animal well-being. Test facility 1 was an 18.3 × 170.7 m solid side-wall broiler house, test facility 2 was a 15.24 × 144.8 m solid side-wall broiler house, and test facility 3 was a 12.19 × 121.9 m curtain side-wall broiler house. Total airflow of each facility, measured with a Fan Assessment and Numeration System, was 512,730, 389,495, and 329,270 m 3 h -1 for test facilities 1, 2, and 3, respectively. Air velocity distribution patterns were characterized in each house with a Scalable Environment Assessment System (SEAS) and spatial statistics. The air velocity distributions within the test facilities were variable, with notable maxima immediately downstream of the tunnel inlets, which serve as a well-defined vena contracta, and local minima near the leading end of the evaporative pads and the exhaust fans. Equipment within the facilities had an impact on the air velocity distribution by creating reduced cross-sectional areas that resulted in localized increases in air velocity. The percentage of total bird-level floor area in each facility experiencing air velocities below 1.5 m s -1 was 14.3%, 20.7%, and 10.0% for test facilities 1, 2, and 3, respectively. The effective design velocity (V ed ) was calculated from total airflow using the measured building cross-sectional area. The V ed measured 2.97, 2.45, and 2.34 m s -1 for test facilities 1, 2, and 3, respectively. Mean cross-sectional air velocity (V cs ) was calculated from SEAS data and normalized using each facility’s V ed to account for differences in building size for comparison. Test facility 1, the largest of the three houses, generated substantially higher V cs /V ed than test facilities 2 and 3. Test facilities 2 and 3 maintained a larger proportion of V cs above V ed than test facility 1. Test facility 1 showed 26.5% of the total house length below V ed , while test facilities 2 and 3 had only 20.8% and 17.5%, respectively, of the total house length below V ed . The lower-velocity regions were due to the length of the evaporative cooling pad inlet and the use of tunnel doors, and the exhaust fan placement on the side-walls in test facility 1 created an additional pronounced low-velocity area. Placement of tunnel ventilation fans on the end-wall of the facility, rather than the side-wall, eliminated the low-velocity region at the exhaust end of the facility. Modifications to current practices for broiler production facility construction and evaporative cooling pad inlet installation would be required to minimize the low-velocity region at the inlet end of these facilities. Consideration of house width and physical arrangement of the air inlets, tunnel fans, and internal equipment are critical for improving the uniformity of air velocity in commercial broiler houses. Keywords: Air velocity, Anemometer, Broiler house, FANS, Tunnel ventilation.