Reassessing evidence of life in 3,700-million-year-old rocks of Greenland
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Abstract X-ray Fluorescence (XRF) microscopy is a growing approach for imaging the trace element concentration, distribution, and speciation in biological cells at the nanoscale. Moreover, three-dimensional nanotomography provides the added advantage of imaging subcellular structure and chemical identity in three dimensions without the need for staining or sectioning of cells. To date, technical challenges in X-ray optics, sample preparation, and detection sensitivity have limited the use of XRF nanotomography in this area. Here, XRF nanotomography was used to image the elemental distribution in individual E . coli bacterial cells using a sub-15 nm beam at the Hard X-ray Nanoprobe beamline (HXN, 3-ID) at NSLS-II. These measurements were simultaneously combined with ptychography to image structural components of the cells. The cells were embedded in small (3–20 µm) sodium chloride crystals, which provided a non-aqueous matrix to retain the three-dimensional structure of the E . coli while collecting data at room temperature. Results showed a generally uniform distribution of calcium in the cells, but an inhomogeneous zinc distribution, most notably with concentrated regions of zinc at the polar ends of the cells. This work demonstrates that simultaneous two-dimensional ptychography and XRF nanotomography can be performed with a sub-15 nm beam size on unfrozen biological cells to co-localize elemental distribution and nanostructure simultaneously.
Laser induced fluorescence (LIF) technique development activity for measurement of plasma parameters in ITER divertor plasma is described. Helium density is the task of priority, but Doppler measurement of ion (atom) temperatures is also the aim of the program. The concept of ITER scenarios includes injection of ''extrinsic'' impurities (Ne, Ar, and Kr). It is possible to use the species as tracing elements for measurement of T{sub i}, T{sub a}. The program included modeling experiments on PNX-U (a multicusp trap with microwave argon plasma). Helium was added by puffing into discharge. Temperatures T{sub i}(Ar{sup 1+}) and T{sub a}(He{sup 0}) have been measured by scanning laser line across absorption line of species. Summarizing of fluorescence signals provided input data for estimation of Ar{sup 1+} and He{sup 0} densities via interpretative collisional-radiative models. Besides, the collisional-radiative model has been used for estimation of electron density using the ratio of fluorescence signals at 388.9 and 706.5 nm helium lines.
The main characteristics of the ion beam facility based on a 3.75 MeV Van de Graaff accelerator at the University of Chile are described at this work. Current activities are mainly focused on the application of the Ion Beam Analysis techniques for environmental, archaeological, and material science analysis. For instance, Rutherford Backscattering Spectrometry (RBS) is applied to measure thin gold film thickness which are used to determine their resistivity and other electrical properties. At this laboratory the Proton Induced X-Ray Emission (PIXE) and Proton Elastic Scattering Analysis (PESA) methodologies are extensively used for trace element analysis of urban aerosols (Santiago, Ciudad de Mexico). A similar study is being carried out at the Antarctica Peninsula. Characterization studies on obsidian and vitreous dacite samples using PIXE has been also perform allowing to match some of these artifacts with geological source sites in Chile.Basic physics research is being carried out by measuring low-energy cross section values for the reactions {sup 63}Cu(d,p){sup 64}Cu and {sup Nat}Zn(p,x){sup 67}Ga. Both radionuclide {sup 64}Cu and {sup 67}Ga are required for applications in medicine. Ongoing stopping power cross section measurements of proton and alphas on Pd, Cu, Bi and Mylar are briefly discussed.
An x-ray microprobe system with total-reflection mirror optics for trace element analysis has been developed at beamline 37XU of SPring-8. To achieve sub-microprobe, a spatial filter has been installed downstream of a monochromator. Focusing tests have been performed in the x-ray energy range of 6-14 keV. A focused beam size of 0.83 {mu}m(V)x1.35 {mu}m(H) has been obtained at an x-ray energy of 10 keV, and using a spatial filter in the horizontal direction, the beam size is down to 0.84 {mu}m. Micro-x-ray absorption fine structure (XAFS) spectroscopy of submicrometer particles has been done by utilizing the total-reflection mirror optics. It was clearly observed from the nickel K-edge XAFS spectra that the oxidation state of nickel was a mixture of metal and oxide even in the single submicrometer particle.
Electrostatic tandem accelerators are widely used to accelerate ions for experiments in materials science such as high energy ion implantation, materials modification, and analyses. Many applications require high beam current as well as high beam brightness at the target; thus, maximizing the beam transmission through such electrostatic accelerators becomes important. The Ion Beam Modification and Analysis Laboratory (IBMAL) at University of North Texas is equipped with four accelerators, one of which is a 9SDH-2 3.0 MV National Electrostatic Corporation (NEC) Pelletron Registered-Sign tandem accelerator. The tandem accelerator is equipped with three ion sources: one radio frequency-He ion source (Alphatross) and two ion sources of Cs-sputter type, the SNICS II (Source of Negative Ions by Cesium Sputtering) and a Cs-sputter source for trace-element accelerator based mass spectrometry. This work presents a detailed study of the beam transmission of hydrogen, silicon, and silver ions through the accelerator using the SNICS ion source with injection energies ranging from 20 keV to 70 keV. The beam transmission is quantified for three different terminal voltages: 1.5 MV, 2.0 MV and 2.5 MV. For a given terminal voltage, it has been found that beam transmission is strongly dependent on the ion source injector potential. Details of experiments and data analysis are presented.
The Ion Beam Modification and Analysis Laboratory (IBMAL) at the University of North Texas includes several accelerator facilities with capabilities of producing a variety of ion beams from tens of keV to several MeV in energy. The four accelerators are used for research, graduate and undergraduate education, and industrial applications. The NEC 3MV Pelletron tandem accelerator has three ion sources for negative ions: He Alphatross and two different SNICS-type sputter ion sources. Presently, the tandem accelerator has four high-energy beam transport lines and one low-energy beam transport line directly taken from the negative ion sources for different research experiments. For the low-energy beam line, the ion energy can be varied from {approx}20 to 80 keV for ion implantation/modification of materials. The four post-acceleration beam lines include a heavy-ion nuclear microprobe; multi-purpose PIXE, RBS, ERD, NRA, and broad-beam single-event upset; high-energy ion implantation line; and trace-element accelerator mass spectrometry. The NEC 3MV single-ended Pelletron accelerator has an RF ion source mainly for hydrogen, helium and heavier inert gases. We recently installed a capacitive liner to the terminal potential stabilization system for high terminal voltage stability and high-resolution microprobe analysis. The accelerator serves a beam line for standard RBS and RBS/C. Another beamline for high energy focused ion beam application using a magnetic quadrupole lens system is currently under construction. This beam line will also serve for developmental work on an electrostatic lens system. The third accelerator is a 200 kV Cockcroft-Walton accelerator with an RF ion source. The fourth accelerator is a 2.5 MV Van de Graaff accelerator, which was in operation for last several decades is currently planned to be used mainly for educational purpose. Research projects that will be briefly discussed include materials synthesis/modification for photonic, electronic, and magnetic applications, surface sputtering and micro-fabrication of materials, development of high-energy ion microprobe systems, and educational and outreach activities.
X-ray fluorescence probe for detection of foreign material inclusions on the inner surface of superconducting cavities has been developed and tested. The setup detects trace element content such as a few micrograms of impurities responsible for thermal breakdown phenomena limiting the cavity performance. The setup has been customized for the geometry of 1.3 GHz TESLA-type niobium cavities and focuses on the surface of equator area at around 103 mm from the centre axis of the cavities with around 20 mm detection spot. More precise localization of inclusions can be reconstructed by means of angular or lateral displacement of the cavity. Preliminary tests confirmed a very low detection limit for elements laying in the high efficiency spectrum zone (from 5 to 10 keV), and a high angular resolution allowing an accurate localization of defects within the equator surface.
Boron is the critical trace element in the production of high quality steel, creating a great demand for an efficient detection method of the B-K emission band at around 6.76 nm. To meet this demand we made a simulation study and obtained a practical method to improve the diffraction efficiency of metal-coated laminar-type gratings for a grazing incidence flat-field spectrograph by overcoating a sufficiently transparent high-density material. In the simulation the diffraction efficiency in a spectral region of 3.5-8.5 nm was computed for several combinations of overcoating materials and coating metals, with various thicknesses of the overcoating layer. The result obtained are: (1) the best overcoating material is high-density diamond-like carbon (DLC) having a density of 3.1 g/cm{sup 3}, (2) its optimum thickness is 24 nm at an angle of incidence of 87.0°, and (3) with this thickness the first-order diffraction efficiency is expected to reach 29.7 %, which well exceeds 15.6 % for Ni-coated (or 14.1 % for Au-coated) grating.
Understanding the evolution of damage and deformation due to spall at grain boundaries can provide a basis for connecting micro- to macroscale failure behavior in metals under extreme conditions. Copper bicrystal samples were shock loaded using flyer-plate impacts in a light gas gun with shock stresses ranging from 3 to 6 GPa. Pulse duration as well as crystal orientation along the shock direction were varied for a fixed boundary misorientation to determine their effects on void nucleation and coalescence. Samples were soft recovered and cross-sectioned to characterize damage using electron backscattering diffraction and scanning electron microscopy to gather information on damage characteristics at and around the GB, with emphasis on growth of boundary and bulk voids. Chemistry and composition analysis were also performed on samples to determine if trace elements present in a sample affected the threshold for void nucleation. Results show that the kinetics of damage growth at the boundary are strongly affected by stress level and impurities. It was found that the boundary selected had a similar or even lower tendency to show damage than the bulk at low pulse durations and amplitudes. As pulse duration and amplitude increased damage localized at the boundary, which was found to consist of many small voids, indicating that the boundary experienced rapid void nucleation and coalescence. Furthermore, the presence of impurities correlated strongly with scatter on damage evolution.
We have studied more than 2000 presolar silicon carbide (SiC) grains from the Murchison CM2 chondrite in the size range 0.2-0.5 {mu}m for C- and Si-isotopic compositions. In a subset of these grains, we also measured N-, Mg-Al-, S-, and Ca-Ti-isotopic compositions as well as trace element concentrations. The overall picture emerging from the isotope data is quite comparable with that of larger grains, except for the abundances of grains from Type II supernovae (SNeII) and low-metallicity asymptotic giant branch (AGB) stars. Especially, the latter are much more abundant among submicrometer-sized grains than among micrometer-sized grains. This implies that SiC grains from lower-than-solar-metallicity AGB stars are on average smaller than those from solar metallicity AGB stars which provided the majority of presolar SiC grains. We identified five grains with large enrichments in {sup 29}Si (up to 3.5x solar) and {sup 30}Si (up to 3.9x solar in three of these grains). These grains are most likely from SNeII. The isotopically light S ({sup 32}S/{sup 34}S of 2x solar) together with the heavy Si in one of these grains suggests that molecule formation precedes macroscopic mixing and dust formation in SNII ejecta. This adds to the complexity of SN mixing calculations and should be considered in future studies. In total, about 2% of the presolar SiC grains in the size range 0.2-0.5 {mu}m appear to come from SNeII. This is about a factor of 2 higher than for micrometer-sized grains and suggests that SNeII, on average, produce smaller SiC grains than solar metallicity AGB stars. The high {sup 29}Si/{sup 30}Si ratio in one of the SN grains suggests that current SN models underestimate the {sup 29}Si production in the C- and Ne-burning regions by about a factor of 2. It is shown that with this adjustment the solar {sup 29}Si/{sup 28}Si ratio can be well reproduced in Galactic chemical evolution models and that a merger of our Galaxy with a low-metallicity satellite some 1.5 Gyr before solar system formation could account for the slope 1.3 of the Si mainstream line.
Abstract Cyclotron radiation emission spectroscopy (CRES) is an approach to measuring the energy of an electron trapped in an externally applied magnetic field. The bare electron can come from different interactions, including photoelectric absorption, Compton scatters, beta decay, and pair production. CRES relies on measuring the frequency of the electron’s cyclotron motion, and because the measurement times extend over 10 6 –10 7 cycles, the energy resolution is on the order of a single electronvolt. To date, CRES has only been performed on internal beta-emitting radioisotopes, but the technology can be applied to x-ray spectrometery through appropriate selection of a target gas and sufficient intensity of the distinct x-ray source. The applications of this technology range from high-precision measurements of atomic energy levels to calibrations of basic science experiments, to trace element identification. In this work we explore the use of CRES for x-ray spectroscopy within the rubric of measuring the energy levels of argon. Though the energy levels of argon are well established, we adopt this motivation as an example question around which a detector may be designed. The issues we explore include target material, density, electron trapping depth, noise levels, and overall efficiency. We also discuss spectral deconvolution and how the multiple peaks obtained from a single target/source pair can be used to enhance the robustness of the measurement.
The short-lived radionuclide {sup 26}Al existed throughout the solar nebula 4.57 Ga ago, and the initial abundance ratio ({sup 26}Al/{sup 27}Al){sub 0}, as inferred from magnesium isotopic compositions of calcium-aluminum-rich inclusions (CAIs) in chondritic meteorites, has become a benchmark for understanding early solar system chronology. Internal mineral isochrons in most CAIs measured by secondary ion mass spectrometry (SIMS) give ({sup 26}Al/{sup 27}Al){sub 0} {approx} (4-5) x 10{sup -5}, called 'canonical'. Some recent high-precision analyses of (1) bulk CAIs measured by multicollector inductively coupled plasma mass spectrometry (MC-ICPMS), (2) individual CAI minerals and their mixtures measured by laser-ablation MC-ICPMS, and (3) internal isochrons measured by multicollector (MC)-SIMS indicated a somewhat higher 'supracanonical' ({sup 26}Al/{sup 27}Al){sub 0} ranging from (5.85 {+-} 0.05) x 10{sup -5} to >7 x 10{sup -5}. These measurements were done on coarse-grained Type B and Type A CAIs that probably formed by recrystallization and/or melting of fine-grained condensate precursors. Thus the supracanonical ratios might record an earlier event, the actual nebular condensation of the CAI precursors. We tested this idea by performing in situ high-precision magnesium isotope measurements of individual minerals in a fine-grained CAI whose structures and volatility-fractionated trace element abundances mark it as a primary solar nebula condensate. Such CAIs are ideal candidates for the fine-grained precursors to the coarse-grained CAIs, and thus should best preserve a supracanonical ratio. Yet, our measured internal isochron yields ({sup 26}Al/{sup 27}Al){sub 0} = (5.27 {+-} 0.17) x 10{sup -5}. Thus our data do not support the existence of supracanonical ({sup 26}Al/{sup 27}Al){sub 0} = (5.85-7) x 10{sup -5}. There may not have been a significant time interval between condensation of the CAI precursors and their subsequent melting into coarse-grained CAIs.
Europa's tenuous atmosphere results from sputtering of the surface. The trace element composition of its atmosphere is therefore related to the composition of Europa's surface. Magnesium salts are often invoked to explain Galileo Near Infrared Mapping Spectrometer spectra of Europa's surface, thus magnesium may be present in Europa's atmosphere. We have searched for magnesium emission in the Hubble Space Telescope Faint Object Spectrograph archival spectra of Europa's atmosphere. Magnesium was not detected and we calculate an upper limit on the magnesium column abundance. This upper limit indicates that either Europa's surface is depleted in magnesium relative to sodium and potassium, or magnesium is not sputtered as efficiently resulting in a relative depletion in its atmosphere.
ABSTRACT Selenium is an essential trace element that can modulate the gut microbiome with an impact on host health. The present study aimed to evaluate the effects of organic (selenium-enriched yeast) vs inorganic (sodium selenite) selenium source on fecal end-fermentation products and gut microbiome of puppies from 20 to 52 weeks of age. Alpha and beta diversity of the gut bacterial community were affected by age but not by gender or selenium source. The relative abundance of taxa was differently affected by age, and the DNA concentration of all selected bacterial groups increased with age, although total volatile fatty acids (VFA), acetate, propionate, caproate and lactate concentrations decreased. Organic selenium was associated with a higher concentration of total VFA, propionate and butyrate, a higher number of DNA copies of Lactobacillus, and a trend to lower DNA copies of Escherichia coli. Effects on fecal microbiome during growth differed with selenium source. Females had higher fecal end-fermentation products related to protein degradation, whereas males had higher DNA concentration of Bifidobacterium. Organic selenium might be beneficial over inorganic for dog food supplementation due to the positive modulation of the gut microbiome observed in puppies.
Abstract Synchrotron-based X-ray fluorescence microscopy is a flexible tool for identifying the distribution of trace elements in biological specimens across a broad range of sample sizes. The technique is not particularly limited by sample type and can be performed on ancient fossils, fixed or fresh tissue specimens, and in some cases even live tissue and live cells can be studied. The technique can also be expanded to provide chemical specificity to elemental maps, either at individual points of interest in a map or across a large field of view. While virtually any sample type can be characterized with X-ray fluorescence microscopy, common biological sample preparation methods (often borrowed from other fields, such as histology) can lead to unforeseen pitfalls, resulting in altered element distributions and concentrations. A general overview of sample preparation and data-acquisition methods for X-ray fluorescence microscopy is presented, along with outlining the general approach for applying this technique to a new field of investigation for prospective new users. Considerations for improving data acquisition and quality are reviewed as well as the effects of sample preparation, with a particular focus on soft tissues. The effects of common sample pretreatment steps as well as the underlying factors that govern which, and to what extent, specific elements are likely to be altered are reviewed along with common artifacts observed in X-ray fluorescence microscopy data.
The microscopy research at the Bionanoprobe (currently at beamline 9-ID and later 2-ID after APS-U) of Argonne National Laboratory focuses on applying synchrotron X-ray fluorescence (XRF) techniques to obtain trace elemental mappings of cryogenic biological samples to gain insights about their role in critical biological activities. The elemental mappings and the morphological aspects of the biological samples, in this instance, the bacterium Escherichia coli ( E. Coli ), also serve as label-free biological fingerprints to identify E. coli cells that have been treated differently. The key limitations of achieving good identification performance are the extraction of cells from raw XRF measurements via binary conversion, definition of features, noise floor and proportion of cells treated differently in the measurement. Automating cell extraction from raw XRF measurements across different types of chemical treatment and the implementation of machine-learning models to distinguish cells from the background and their differing treatments are described. Principal components are calculated from domain knowledge specific features and clustered to distinguish healthy and poisoned cells from the background without manual annotation. The cells are ranked via fuzzy clustering to recommend regions of interest for automated experimentation. The effects of dwell time and the amount of data required on the usability of the software are also discussed.
The structure and crystal chemistry of vernadite in ferromanganese crusts from the Magellan Seamount in the north-west Pacific Ocean have been investigated using synchrotron X-ray diffraction (XRD), X-ray pair distribution function (PDF) and high-resolution transmission electron microscopy (TEM). XRD patterns of vernadite mainly show two strong diffraction peaks at 2.42–2.43 Å and 1.41 Å without or with a broad (001) diffraction peak, indicating thin layer nanophases along the c -direction. TEM images show flat and curved sheet-like nanocrystals with (001) layer thickness of ~7.2 Å and ~9.6 Å, and their interstratified structure. PDF patterns of the vernadite are similar to those from synthetic δ-MnO 2 and defective birnessite, suggesting a phyllomanganate framework. Combined XRD/PDF patterns suggest that vernadite in the outer part is associated with a higher density interlayer species at triple-edge sharing sites. The proportion of the 10 Å phase increases from the outer (young) part to the inner (old) part of the Mn crusts due to aging and sorption of Mn, Co and Ni from ambient seawater. This study suggests that this combined method of synchrotron radiation XRD/PDF and high-resolution TEM is a powerful tool to determine atomic structures of poorly crystallized nano-minerals. The mixture model of vernadite structure will help to understand the partitioning and distribution of trace elements in the ferromanganese crusts.