Quiet Spacecraft Cabin Ventilation Fan: Acoustic Measurements Results

A spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were – static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. This report documents the acoustic measurements as part of a series of reports.

o Small Fan Noise, Testing, Duct Modes↗

Quiet Spacecraft Cabin Ventilation Fan: Aerodynamic Measurements Results

A spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were from: static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. This report documents the aerodynamic measurements as part of a series of reports.

Small Fan Noise,↗

Quiet Spacecraft Cabin Ventilation Fan: Acoustic Measurements Results

A quiet spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were – static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. This report documents the acoustic measurements as part of a series of reports.

Small Fan Noise↗

Quiet Spacecraft Cabin Ventilation Fan: Aerodynamic Measurements Results

A metal spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed and two copies of the fan assembly were fabricated. Both fans were tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were – static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot wire measurements of the fan wake. This report documents the aerodynamic measurements as part of a series of reports.

o Small Fan Noise, Testing, Duct Modes↗

Gateway Integrated ECLSS Model Analysis of Intermodule Ventilation Failures

The Gateway Integrated ECLSS Model (GIEM) is a set of two independent models, made in Aspen Custom Modeler (ACM) and Thermal Desktop (TD), of the Gateway stack and each modules' associated environment control and life support system (ECLSS). The GIEM utilizes the 41-Node Metabolic Man (METMAN) to simulate crew inside the Gateway consuming O2 and producing CO2, H2O, and heat for the ECLSS to remove. The modules and visiting vehicles all have different levels of ECLSS capabilities and may rely on other modules and Intermodular Ventilation (IMV), which is used to exchange gas between the modules, to ensure the entire Gateway environment is controlled. If IMV were to fail or be turned off, some vehicles may have limited access to necessary ECLSS functions. This analysis focuses on evaluating O2, CO2, and H2O levels when crew are in vehicles without their own life support and IMV has failed to evaluate how long before the atmosphere is unsafe for the crew. This analysis uses the integrated nature of the GIEM to look at time to effect for O2 depletion and CO2 and H2O buildup when crew are working in vehicles that have been cut off from the ECLSS-active portion of the stack. This information is used to inform for how long crew can safely continue working in the ECLSS-inactive vehicles before experiencing a requirement violation or physical limitation and can be referenced when developing maintenance and emergency response concept of operations (ConOps).

Lawrence Barrett↗

Evaluation of the Accumulation of Foreign Object Debris in the International Space Station Ventilation Systems and Resulting Impacts to Systems

A challenge for the International Space Station (ISS) is accumulation of foreign object debris (FOD) in the ventilation systems and the impacts to crew, equipment, and experiments. One function of the temperature and humidity control system is to capture FOD with various methods of filtration to minimize these impacts. ISS filtration has been augmented by charcoal and High Efficiency Particulate Air (HEPA) filters and screens. A qualitative comparison of the quantity of FOD found since 2012 study and the current levels are evaluated. Impacts due to FOD are reduced air circulation, increased crew time for cleaning, reduction of equipment life, and component damage; examples are provided. Recommendations for further improvements to reduce the accumulation of FOD on ISS are provided.

ISS↗

Spacesuit Sizing by Multivariate Simulation: Case Study for Liquid Cooling and Ventilation Garment

A technique was developed to assess the fit of spacesuit garment liquid cooling and ventilation garment (LCVG). A fit scoring scheme was built from the spacesuit sizing requirements and guidelines, and the accommodated proportion of the wearer population was estimated from statistically synthesized pseudo population data. The method evaluated different scenarios of LCVG sizing systems including 1) baseline 7-size system, 2) 7-sizes with target body dimensions iteratively adjusted for maximum fit, and 3) 9-sizes with iterative adjustments. Overall, the baseline sizing system showed 81% accommodation rate, while the hypothetical new systems in-tegrating iterative adjustments for 7- and 9-sizes predictively indicated that accommodation could improve up to 92 and 97%. The proposed method provided a structured metric to quantify fit performance of a garment sizing system, which can be further applied to different spacesuit component, PPE and garment designs.

Han Kim↗

Ventilating Your Home

This guide explains proper ventilation techniques for indoor air quality.

air sealing↗

Heating, ventilation, air conditioning and refrigeration system

A heating, ventilation, air conditioning and refrigeration (HVAC/R) system includes a sorption circuit including a heat absorption heat exchanger in fluid communication with a primary fluid flow source such that a primary fluid flow from is directed therethrough. The heat absorption heat exchanger is configured to exchange thermal energy between the primary fluid flow and a secondary fluid flow. A sorption heat exchanger includes a sorbent material to adsorb or absorb the primary fluid flow, generating thermal energy. The sorption heat exchanger is configured to transfer the generated thermal energy to a tertiary fluid flow. A heat exchange circuit is in fluid communication with the sorption circuit and includes a control valves connected to both the secondary fluid flow and the tertiary fluid flow configured to selectably direct the secondary fluid flow and/or the tertiary fluid flow to a conditioning heat exchanger or an ambient heat exchanger.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Efficient Tool-Set for Modeling Containment Ventilation in Very Complex Facilities - 17215

The applicability of a multi-zone ventilation analysis program, CONTAM, to complex radioactive waste material handling or processing plants is evaluated. Validation results are based on simulations from three-dimensional multi-physics computational fluid dynamics. Insight into the application limits of CONTAM and conditions under which the use of higher fidelity tools are required are also discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Secondary Pollutants from Ozone Reaction with Ventilation Filters and Degradation of Filter Media Additives

Prior research suggests that chemical processes taking place on the surface of particle filters employed in buildings may lead to the formation of harmful secondary byproducts. We investigated ozone reactions with fiberglass, polyester, cotton/polyester and polyolefin filter media, as well as hydrolysis of filter media additives. Studies were carried out on unused media, and on filters that were installed for 3 months in buildings at two different locations in the San Francisco Bay Area. Specimens from each filter media were exposed to {approx}150 ppbv ozone in a flow tube under a constant flow of dry or humidified air (50percent RH). Ozone breakthrough was recorded for each sample over periods of {approx}1000 min; the ozone uptake rate was calculated for an initial transient period and for steady-state conditions. While ozone uptake was observed in all cases, we did not observe significant differences in the uptake rate and capacity for the various types of filter media tested. Most experiments were performed at an airflow rate of 1.3 L/min (face velocity = 0.013 m/s), and a few tests were also run at higher rates (8 to 10 L/min). Formaldehyde and acetaldehyde, two oxidation byproducts, were quantified downstream of each sample. Those aldehydes (m/z 31 and 45) and other volatile byproducts (m/z 57, 59, 61 and 101) were also detected in real-time using Proton-Transfer Reaction - Mass Spectrometry (PTR-MS). Low-ppbv byproduct emissions were consistently higher under humidified air than under dry conditions, and were higher when the filters were loaded with particles, as compared with unused filters. No significant differences were observed when ozone reacted over various types of filter media. Fiberglass filters heavily coated with impaction oil (tackifier) showed higher formaldehyde emissions than other samples. Those emissions were particularly high in the case of used filters, and were observed even in the absence of ozone, suggesting that hydrolysis of additives, rather than ozonolysis, is the main formaldehyde source in those filters. Emission rates of formaldehyde and acetaldehyde were not found to be large enough to substantially increase indoor concentrations in typical building scenarios. Nevertheless, ozone reactions on HVAC filters cannot be ignored as a source of low levels of indoor irritants.

54 ENVIRONMENTAL SCIENCES↗

Review of Literature on Terminal Box Control, Occupancy Sensing Technology and Multi-zone Demand Control Ventilation (DCV)

This report presents an overall review of the standard requirement, the terminal box control, occupancy sensing technology and DCV. There is system-specific guidance for single-zone systems, but DCV application guidance for multi-zone variable air volume (VAV) systems is not available. No real-world implementation case studies have been found using the CO 2 -based DCV. The review results also show that the constant minimum air flow set point causes excessive fan power consumption and potential simultaneous heating and cooling. Occupancy-based control (OBC) is needed for the terminal box in order to achieve deep energy savings. Key to OBC is a technology for sensing the actual occupancy of the zone served in real time. Several technologies show promise, but none currently fully meets the need with adequate accuracy and sufficiently low cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗