Search NASA⌕ Search

SEARCH · Search NASA

Results for “visual tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Analysis of eye-tracking experiments performed on a Tobii T60

Commercial eye-gaze trackers have the potential to be an important tool for quantifying the benefits of new visualization techniques. The expense of such trackers has made their use relatively infrequent in visualization studies. As such, it is difficult for researchers to compare multiple devices obtaining several demonstration models is impractical in cost and time, and quantitative measures from real-world use are not readily available. In this paper, we present a sample protocol to determine the accuracy of a gaze-tacking device.

47 OTHER INSTRUMENTATION↗

Oculometric Surveillance of Neuro-Ocular Function

Future missions to the moon or Mars will require the crew to monitor and assess their health and performance more autonomously, with approaches easily useable and interpretable by non-clinicians. If an autonomous oculometric diagnostic-support system proves to be a reliable predictor of impending impairment of visual function in the case of primary ocular pathology on Earth, then it could also be applied in the future to the surveillance of crew to detect the potential progression of sensorimotor and neuro-ocular compromises during extended spaceflight missions, e.g., SANS, and thus guide earlier and more effective countermeasure intervention. Towards that goal, we intend to determine if a set of largely independent eye-movement metrics, called oculometrics, measured using a simple voluntary eye-tracking task that can be completed in just 5 minutes per eye, could provide clinically valid biomarkers of functional visual deficits due to primary ocular pathology. The premise is that oculometrics could be used to monitor slowly evolving ocular pathologies, potentially detecting them even before structural evidence appears in ocular imaging or other current state-of-the-art clinical measures. This study investigates how NASA’s patented oculometric assessment of visual and visuomotor function, shown to correlate with performance in a manual control task, will correlate with standard ophthalmological tests to confirm clinical and thus operational, validity.

eye movements↗

Wind measurements by parachute

Tests used the 8 cm Lotta grenade as well as 12 cm M/70 and 10.5 m/62 grenades, released at altitudes between 2000 and 6400 meters. The parachutes were tracked by AP and RFK. In later experiments wind data were also obtained for comparison by tracking hydrogen filled balloons in part with the CORA system, in part with radar. Generally radar picked up the objects without visual assistance. Wind measurements from parachutes correlated well with those obtained by balloon. Even when the radar locked on to a part of a grenade, descending faster than the parachute, some of the measurements obtained were good. Bodies with a greater rate of descent than parachutes, with less or no tendency toward drift and with sufficient, surface for radar tracking, ought to provide reliable results. The existence of vertically well defined winds of jet stream type at low altitudes was established.

Nordstroem, S.↗

TH-AB-202-05: BEST IN PHYSICS (JOINT IMAGING-THERAPY): First Online Ultrasound-Guided MLC Tracking for Real-Time Motion Compensation in Radiotherapy

Purpose: While MLC tracking has been successfully used for motion compensation of moving targets, current real-time target localization methods rely on correlation models with x-ray imaging or implanted electromagnetic transponders rather than direct target visualization. In contrast, ultrasound imaging yields volumetric data in real-time (4D) without ionizing radiation. We report the first results of online 4D ultrasound-guided MLC tracking in a phantom. Methods: A real-time tracking framework was installed on a 4D ultrasound station (Vivid7 dimension, GE) and used to detect a 2mm spherical lead marker inside a water tank. The volumetric frame rate was 21.3Hz (47ms). The marker was rigidly attached to a motion stage programmed to reproduce nine tumor trajectories (five prostate, four lung). The 3D marker position from ultrasound was used for real-time MLC aperture adaption. The tracking system latency was measured and compensated by prediction for lung trajectories. To measure geometric accuracy, anterior and lateral conformal fields with 10cm circular aperture were delivered for each trajectory. The tracking error was measured as the difference between marker position and MLC aperture in continuous portal imaging. For dosimetric evaluation, 358° VMAT fields were delivered to a biplanar diode array dosimeter using the same trajectories. Dose measurements with and without MLC tracking were compared to a static reference dose using a 3%/3 mm γ-test. Results: The tracking system latency was 170ms. The mean root-mean-square tracking error was 1.01mm (0.75mm prostate, 1.33mm lung). Tracking reduced the mean γ-failure rate from 13.9% to 4.6% for prostate and from 21.8% to 0.6% for lung with high-modulation VMAT plans and from 5% (prostate) and 18% (lung) to 0% with low modulation. Conclusion: Real-time ultrasound tracking was successfully integrated with MLC tracking for the first time and showed similar accuracy and latency as other methods while holding the potential to measure target motion non-invasively. SI was supported by the Graduate School for Computing in Medicine and Life Science, German Excellence Initiative [grant DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

The artificial retina processor for track reconstruction at the LHC crossing rate

We present results of an R&D study for a specialized processor capable of precisely reconstructing, in pixel detectors, hundreds of charged-particle tracks from high-energy collisions at 40 MHz rate. We apply a highly parallel pattern-recognition algorithm, inspired by studies of the processing of visual images by the brain as it happens in nature, and describe in detail an efficient hardware implementation in high-speed, high-bandwidth FPGA devices. This is the first detailed demonstration of reconstruction of offline-quality tracks at 40 MHz and makes the device suitable for processing Large Hadron Collider events at the full crossing frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte-Carlo Simulation of Radiation Track Structure and Calculation of Dose Deposition in Nanovolumes

INTRODUCTION: The radiation track structure is of crucial importance to understand radiation damage to molecules and subsequent biological effects. Of a particular importance in radiobiology is the induction of double-strand breaks (DSBs) by ionizing radiation, which are caused by clusters of lesions in DNA, and oxidative damage to cellular constituents leading to aberrant signaling cascades. DSB can be visualized within cell nuclei with gamma-H2AX experiments. MATERIAL AND METHODS: In DSB induction models, the DSB probability is usually calculated by the local dose obtained from a radial dose profile of HZE tracks. In this work, the local dose imparted by HZE ions is calculated directly from the 3D Monte-Carlo simulation code RITRACKS. A cubic volume of 5 micron edge (Figure 1) is irradiated by a (Fe26+)-56 ion of 1 GeV/amu (LET approx.150 keV/micron) and by a fluence of 450 H+ ions, 300 MeV/amu (LET approx. 0.3 keV/micron). In both cases, the dose deposited in the volume is approx.1 Gy. The dose is then calculated into each 3D pixels (voxels) of 20 nm edge and visualized in 3D. RESULTS AND DISCUSSION: The dose is deposited uniformly in the volume by the H+ ions. The voxels which receive a high dose (orange) corresponds to electron track ends. The dose is deposited differently by the 56Fe26+ ion. Very high dose (red) is deposited in voxels with direct ion traversal. Voxels with electron track ends (orange) are also found distributed around the path of the track. In both cases, the appearance of the dose distribution looks very similar to DSBs seen in gammaH2AX experiments, particularly when the visualization threshold is applied. CONCLUSION: The refinement of the dose calculation to the nanometer scale has revealed important differences in the energy deposition between high- and low-LET ions. Voxels of very high dose are only found in the path of high-LET ions. Interestingly, experiments have shown that DSB induced by high-LET radiation are more difficult to repair. Therefore, this new approach may be useful to understand the nature of DSB and oxidative damage induced by ionizing radiation.

Plante, I.↗

In-situ observation of calcium chloride hexahydrate phase separation via neutron imaging

Inorganic salt hydrate offers a low-cost thermal energy storage solution with high energy density, but phase separation during thermal cycling poses a significant challenge, leading to irreversible performance degradation. In this research, neutron radiography was used to investigate phase separation in calcium chloride hexahydrate (CaCl₂·6H₂O, CCH) during thermal cycling to track its gradual accumulation into calcium chloride tetrahydrate (CaCl₂·4H₂O, CC4). Through in-situ visualization, phase separation and CC4 sedimentation were observed to occur during the cooling phase between 301.40 K and 304.80 K. CC4 accumulated linearly to 7.99 wt% after 10 thermal cycles. Crystallization and multi-cycle conversion models were developed to validate neutron imaging results of CC4 formation. The predicted CC4 content after 10 thermal cycles closely aligned with experimental observations. Neutron imaging offers a novel approach to investigate salt hydrate phase change materials (PCMs). It enables in-situ visualization of sub-hydrate (CC4) formation from original hydrate (CCH) in metastable phase change range (between 301.40 ± 0.66 K and 304.80 ± 0.60 K). Thereby, it provides a new insight of understanding the basis of phase separation mechanism and paves the way for future research of improving PCM thermal cycling performance.

Li, Yucen [The University of Tennessee, Knoxville]↗

Under-sodium viewing technology for improvement of fast-reactor safeguards

The current safeguards approach for fast reactors relies exclusively on maintenance of continuity of knowledge to track the movement of fuel assemblies through these facilities. The remote handling of fuel assemblies, the visual opacity of the liquid metal coolant. and the chemical reactivity of sodium all combine and result in significant limitations on the available options to verify fuel assembly identification numbers or the integrity of these assemblies. These limitations also serve to frustrate attempts to restore the continuity-of-knowledge in instances where the information is under a variety of scenarios. The technology of ultrasonic under-sodium viewing offers new options to the safeguards community for recovering continuity-of-knowledge and applying more traditional item accountancy to fast reactor facilities. We have performed a literature review to investigate the development of under-sodium viewing technologies. In this paper we will summarize our findings and report the state of development of this technology and we will present possible applications to the fast reactor system to improve the existing safeguards approach at these reactors and in future fast reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In situ visualization of newly synthesized proteins in environmental microbes using amino acid tagging and click chemistry

Summary Here we describe the application of a new click chemistry method for fluorescent tracking of protein synthesis in individual microorganisms within environmental samples. This technique, termed bioorthogonal non‐canonical amino acid tagging ( BONCAT ), is based on the in vivo incorporation of the non‐canonical amino acid L ‐azidohomoalanine ( AHA ), a surrogate for l ‐methionine, followed by fluorescent labelling of AHA ‐containing cellular proteins by azide‐alkyne click chemistry. BONCAT was evaluated with a range of phylogenetically and physiologically diverse archaeal and bacterial pure cultures and enrichments, and used to visualize translationally active cells within complex environmental samples including an oral biofilm, freshwater and anoxic sediment. We also developed combined assays that couple BONCAT with ribosomal RNA (rRNA)‐targeted fluorescence in situ hybridization ( FISH ), enabling a direct link between taxonomic identity and translational activity. Using a methanotrophic enrichment culture incubated under different conditions, we demonstrate the potential of BONCAT‐FISH to study microbial physiology in situ . A direct comparison of anabolic activity using BONCAT and stable isotope labelling by nano‐scale secondary ion mass spectrometry ( 15 NH 3 assimilation) for individual cells within a sediment‐sourced enrichment culture showed concordance between AHA ‐positive cells and 15 N enrichment. BONCAT‐FISH offers a fast, inexpensive and straightforward fluorescence microscopy method for studying the in situ activity of environmental microbes on a single‐cell level.

59 BASIC BIOLOGICAL SCIENCES↗

Energy finance data warehouse: Tracking revenues through the power sector

Reliable data is needed to understand financial relationships in the power sector. However, relevant data acquisition and visualization can be a challenge due to the fragmented nature of the power sector. The Energy Policy and Systems Analysis office of the U.S. Department of Energy led a team of data scientists at Oak Ridge National Lab to collect revenue information from a variety of sources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating long-term model-based scenarios of the energy system

Energy-economic models are used to provide science-based decision support in a variety of contexts. Analyses using these tools often involve defining a “reference” scenario, which serves as a counterfactual against which alternative scenarios are compared. Evaluating scenarios, including reference scenarios, is critical for establishing the credibility of the analyses these models support. We propose a framework for evaluating energy system scenarios which consists of three parts – a qualitative storyline, quantitative metrics, and evaluation criteria. We apply this framework to the reference scenario for GCAM-USA, a version of the global human-Earth system model GCAM (Global Change Assessment Model) with state-level detail in the United States, focusing on the evolution of the electric power sector. We develop new visual analytic tools to facilitate the evaluation of model outcomes in 51 sub-national regions, and demonstrate how scenario performance can be tracked and compared across four quantifications of the GCAM-USA reference scenario.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simulator Investigation of Controls and Display Required for Terminal Phase of Coplanar Orbital Rendezvous

A simulator study was made of presentations and control requirements for a manned astrovehicle employed in the interception of artificial satellites during the terminal phase of an orbital rendezvous of the satellite. The study was considered in terms of a manned interceptor having a home berth at a manned space station which is in circular orbit 500 miles above the earth. Interceptions were restricted to coplanar conditions and ranges of one-half mile. The results are believed to be generally applicable to conditions wherein the target is in the terminal area. Presentations which do not provide for attitude indications of the intercepting vehicle are not satisfactory. A direct-visual-observation presentation employing a screen, a projected star background, and a projected image of the target provided a feeling of "realism" in tracking and would be a satisfactory pilot-training aid. Use of longitudinal-translation and attitude controls alone is inadequate. Use of translation control alone, parallel and normal to the axis of the intercepting vehicle, is effective; the addition of attitude control enhanced the effectiveness, provided the control was used discriminately. Direct-visual-observation interceptions can be performed effectively without the aid of range and rate-of-closure-of-range meters at speeds up to approximately 50 feet per second; however, higher speeds of interception require the use of these instruments.

Wolowicz, Chester H.↗

Differences in total stem value when merchandizing with a tracked processor versus a knuckle–boom loader in Pinus taeda

Using tracked processors over knuckle–boom loaders to increase total value per tree when merchandizing timber on the landing has become a topic of interest in the southeastern region of the United States. This study compared merchantability values, product classes, and product weights of loblolly pine (Pinus taeda) for both machines to determine if there was a significant difference between machines when processing the same tree. In order to process the same tree twice, the chains from the tracked processor had to be removed from the bottom saw bar. This allowed the processor to simulate the merchandising process without actually marking or cutting the tree for a more realistic comparison. Data were analyzed using paired t–tests and two–way ANOVA models. Results depicted that when diameter and total lengths are visually estimated by the knuckle–boom loader. A significant difference in value occurs, however, once diameter and total length are modified to match the tracked processors for more accurate measurements, no difference in value was seen. Here, these results demonstrate that until mill specifications become more stringent, there is little incentive for loggers to purchase a tracked processor if their only motivation is to increase merchantability values.

42 ENGINEERING↗

The effect of transient needle lift on the internal flow and near-nozzle spray characteristics for modern GDI systems investigated by high-speed X-ray imaging

The development of the injector nozzle is a dynamic area in regard of several technical aspects. At first, the internal flow influences the near-field spray characteristics via various phenomena such as cavitation and turbulence. However, these phenomena are not fully understood due to their extremely fast, complex and multiscale nature. Furthermore, it governs the spray targeting inside the combustion chamber. High-speed X-ray imaging of GDI injector nozzles is performed in this study. The experimental results presented are related to the internal flow and primary breakup of discharged liquid jets. The injectors used are equipped with nozzles made of aluminum which have been specially developed for these investigations to enhance optical accessibility. The visualization of the needle motion, in-nozzle flow and the primary breakup region provides several exciting observations. First, the needle lift tracking exhibits short overshooting right before the steady-state of the injection phase. Additionally, this event leads to a short-term, however, significant change in the associated performance of the breakup. This phenomenon is found to be a consequence of the transient behavior of the in-nozzle flow. It is shown that under some circumstances hydraulic flip may occur during this overshooting period. The primary jet breakup region is visualized and evaluated by means of image processing. Thus, the transient behavior of liquid jet expansion is quantified in the vicinity of the nozzle. It is observed that the liquid jet direction deviates from the hole axis already at the nozzle outlet, which is caused by internal flow characteristics.

42 ENGINEERING↗

Provenance-Enabling DOE Visualization Applications

VisTrails, Inc.’s goal main charter has been to develop provenance management solutions for software tools. As the use of computation increases, keeping track of computational processes and the data they consume and derive is essential for many applications. Provenance (also referred to as audit trail, lineage, and pedigree) captures information about the steps used to generate a given data product. Such information provides important documentation that is key to preserving the data, to determining the data’s quality and authorship, and to reproducing as well as validating the results. Given the growing complexity of the computational processes and the volume of data they manipulate, manual approaches to maintaining provenance are both tedious and error-prone. At VisTrails, Inc., we have implemented infrastructure that can be used to provenance-enable existing tools. We have developed a series of plugins for specific applications, including ParaView and VisIt, which enable these applications to capture provenance. While developing these plugins, we identified general patterns across different applications, and these were used to inform the design of a general framework: the VisTrails Provenance Software Development Kit (SDK). The SDK encapsulates a set of core functionality including methods for capture, navigation, analysis and re-use of provenance. It allows application or plugin developers to more effectively provide provenance support: they can use the core functionality and write code only to handle application specific components. The SDK includes features that can be used in any application, for example, a refined interface for browsing the intermediate and final results captured. While the application-specific plugins were written in Python, the SDK was written from scratch in C++. This has led not only to substantial gains in performance but also the ability to integrate the SDK with applications written in other languages, including Java. To ensure that the SDK supported all of the functionality in the application-specific plugins, we have rewritten some of the existing plugins using the SDK. The SDK can be downloaded from www.vistrals.com/sdk.html.

97 MATHEMATICS AND COMPUTING↗

A Modular Framework for Integrating and Visualizing Telemetry for Mars 2020 Rover Mechanism Operations

The analysis of mechanism telemetry requires a wide variety of tools to quickly and effectively assess spacecraft state, capture long-term trends in system performance, and identify and track anomalous events. Such analysis often requires spacecraft telemetry to first be transformed into derived fields and aggregated statistics before operators can begin their analysis. In past missions, aspects of this process have been automated, but operators were expected to use their own tools and procedures to understand and visualize the data, which led to redundant and inconsistent tools and processes. The Mech Data Tools Python library (MDT) was developed to provide a flexible, unified tool set for operators to extract and analyze mechanism telemetry over the life of the Mars 2020 surface mission. MDT consists of a set of configurable components that implement standard interfaces for ingesting input and producing output. Components can be chained together to form a data processing pipeline. Data are ingested from several sources within the greater Mars 2020 cloud infrastructure and stored in pandas DataFrames, which allows users to leverage the data manipulation capabilities present within the widely-used pandas library. Visualization capabilities are provided through the Plotly library, which generates interactive plots for users to interpret. Following the beginning of Mars 2020 surface operations, usage of MDT has spread to all mechanism-focused subsystems and has demonstrated great utility in analyzing early surface activities. This paper describes MDT’s evolution from heritage mechanism telemetry tools, the critical architecture decisions and challenges faced over MDT’s two years of development, and current applications of MDT in support of mechanism operations.

Wolsieffer, Ben↗

Single-molecule live-cell RNA imaging with CRISPR–Csm

Abstract Understanding the diverse dynamic behaviors of individual RNA molecules in single cells requires visualizing them at high resolution in real time. However, single-molecule live-cell imaging of unmodified endogenous RNA has not yet been achieved in a generalizable manner. Here, we present single-molecule live-cell fluorescence in situ hybridization (smLiveFISH), a robust approach that combines the programmable RNA-guided, RNA-targeting CRISPR–Csm complex with multiplexed guide RNAs for direct and efficient visualization of single RNA molecules in a range of cell types, including primary cells. Using smLiveFISH, we track individual nativeNOTCH2andMAP1Btranscripts in living cells and identify two distinct localization mechanisms including the cotranslational translocation ofNOTCH2mRNA at the endoplasmic reticulum and directional transport ofMAP1BmRNA toward the cell periphery. This method has the potential to unlock principles governing the spatiotemporal organization of native transcripts in health and disease.

Biotechnology & Applied Microbiology↗

U.S.– India Joint Center for Building Energy Research and Development (CBERD) Caring for the Energy Health of Healthcare Facilities

The U.S.-India Joint Center for Building Energy Research & Development (CBERD), created through the Partnership to Accelerate Clean Energy (PACE) agreement between the United States and India, is a research and development (R&D) center with over 30 institutional and industry partners from both nations. This five-year presidential initiative is jointly funded by the U.S. Department of Energy and the Government of India. CBERD aims to build upon a foundation of collaborative knowledge, tools, and technologies, and human capabilities that will increase development of high-performance buildings. To reach this goal, the R&D focuses on energy use reduction throughout the entire life cycle of buildings—i.e., design, construction, and operations. During the operations phase of buildings, even with best-practice energy-efficient design, actual energy use can be much higher than the design intent. Every day, much of the energy consumed by buildings serves no purpose (Roth et al. 2005). Building energy information systems (EIS) are commercially available systems that building owners and facility managers use to assess their building operations, measure, visualize, analyze, and report energy cost and consumption. Energy information systems can enable significant energy savings by tracking energy use, identifying consumption patterns, and benchmarking performance against similar buildings, thereby identifying improvement opportunities. The CBERD team has identified potential energy savings of approximately 2 quads of primary energy in the United States, while industry building energy audits in India have indicated potential energy savings of up to 30 percent in commercial buildings such as offices. Additionally, the CBERD team has identified healthcare facilities (e.g., hospitals, clinics), hotels, and offices as the three of the highest-growth sectors in India that have significant energy consumption, and that would benefit the most from implementation of EIS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗