Search NASA⌕ Search

SEARCH · Search NASA

Results for “wind data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Operating Reserves and Wind Power Integration: An International Comparison

The determination of additional operating reserves in power systems with high wind penetration is attracting a significant amount of attention and research. Wind integration analysis over the past several years has shown that the level of operating reserve that is induced by wind is not a constant function of the installed capacity. Observations and analysis of actual wind plant operating data has shown that wind does not change its output fast enough to be considered as a contingency event. However, the variability that wind adds to the system does require the activation or deactivation of additional operating reserves. This paper provides a high-level international comparison of methods and key results from both operating practice and integration analysis, based on the work in International Energy Agency IEA WIND Task 25 on Large-scale Wind Integration. The paper concludes with an assessment of the common themes and important differences, along with recent emerging trends.

17 WIND ENERGY↗

JHTDB-wind: a web-accessible large-eddy simulation database of a wind farm with virtual sensor querying

This paper introduces JHTDB-wind (https://turbulence.idies.jhu.edu/datasets/windfarms, last access: 11 November 2025), a publicly accessible database containing large-eddy simulation (LES) data from wind farms. Building on the framework of the Johns Hopkins Turbulence Database (JHTDB), which hosts direct numerical simulation (DNS) and some LES datasets of canonical turbulent flows, JHTDB-wind stores the 4D space–time history of the flow and provides users the ability to access and query the data via a web-based virtual sensor interface. The initial dataset comprises LES results from a large wind farm with 10×6 turbines, modeled using a filtered actuator line method, under conventionally neutral atmospheric conditions. These data comprise 1 h (hour) of flow field data (velocity, pressure, potential temperature deviation, subgrid-scale (SGS) eddy viscosity, and turbine forces, approximately 15 TB (terabytes) and wind turbine data – including both turbine-level operational quantities and blade-level aerodynamic quantities (approximately 1.3 TB) – stored in Zarr and Parquet formats, respectively. Data retrieval is facilitated by the giverny Python package, allowing remote users to query the database in Python or MATLAB (C and Fortran support are available for flow field data). This paper details the simulation setup and demonstrates data access through examples that analyze wind farm flow structures and turbine performance. The framework is extensible to future datasets, including the JHTDB-wind diurnal cycle simulation analyzed in Xiao et al. (2025).

17 WIND ENERGY↗

An Analysis of PNM's Renewable Reserve Requirements to Meet New Mexico's Decarbonization Goals

Over the next three years, the Public Service Company of New Mexico (PNM) plans to increase utility-scale solar photovoltaic (PV) capacity from today’s roughly 330MW to about 1600MW. This massive increase in variable generation—from about 15% to 75% of peak load—will require changes in how PNM operates their system. We characterize the 5 and 30-minute solar and wind forecast errors that the system is likely to experience in order to determine the level of reserves needed to counteract such events. Our focus in this study is on negative forecast error (in other words, shortfalls relative to forecast) – whereas excess variable generation can be curtailed if needed, a shortfall must be compensated for to avoid loss of load. Calculating forecast error requires the use of the same forecasting methods that PNM uses or a reasonable approximation thereof. For wind, we use a persistence forecast on actual 5-minute 2019 wind output data (scaled up to reflect the amount of wind capacity planned for 2025). For solar, we use a formula incorporating the clear sky index (CSI) for the forecast. As the solar on the grid now is a small fraction of what is planned for 2025, we generated 5-minute solar data using 2019 weather inputs. We find that to handle 99.9% of the 5-minute negative forecast errors, a maximum of 275MW of variable generation reserve during daylight hours, and a maximum of 75MW during non-daylight hours, should be sufficient. Note that this variable generation reserve is an additional reserve category that specifies reserves over and above what are currently carried for contingency reserve. This would require a significant increase in reserve relative to what PNM currently carries or can call upon from other utilities per reserve sharing agreements. This variable generation reserve specification may overestimate the actual level needed to deal with PNM’s planned variable generation in 2025. The forecasting methodologies used in this study likely underperform PNM’s forecasting – and better forecasting allows for less reserve. To obtain more precise estimates, it is necessary to consider load and use the same forecasting inputs and methods used by PNM.

14 SOLAR ENERGY↗

CMIP6-based Multi-model Hydropower Projection over the Conterminous US, Version 1.1

This dataset presents a suite of hydropower projections for the conterminous United States (CONUS), derived from multiple downscaled and bias-corrected Global Climate Models (GCMs) from the Coupled Model Intercomparison Project Phase 6 (CMIP6). The CMIP6 GCMs are downscaled using either statistical (DBCCA) or dynamical (RegCM) approaches, based on two meteorological reference datasets (Daymet and Livneh). The resulting downscaled precipitation, temperature, and wind speed data are then used to drive two calibrated hydrologic models (VIC and PRMS), enabling simulations of projected future hydrologic responses across the CONUS. Simulated total runoff is subsequently employed to drive two hydropower models (WMP, now implemented as mosartwmpy-power, and WRES) to evaluate how climate change may affect future hydropower production for both federal and non-federal hydropower fleets. This dataset was developed to support the SECURE Water Act Section 9505 Assessment for the U.S. Department of Energy (DOE) Water Power Technologies Office (WPTO). For further details, see Broman et al. (2024), Thurber et al. (2024), Kao et al. (2022), and Zhou et al. (2023).

Voisin, Nathalie [Pacific Northwest National Labor↗

2013 LIDAR Campaign at Buena Vista Wind Farm: An Examination of Hill "Speedup" Flows

In June 2013, two Laser and Detection Ranging (lidar) units (ZephIR 300, Natural Power, North Ledbury, England) were deployed at the Buena Vista Wind Farm in the Altamont Hills region of California until mid-August of that year. This was the third field campaign at Buena Vista for the 12-ERD-069 project, following a winter campaign in 2011-2012 and a summer campaign in 2012. The lidar data provided wind measurements at the base (“flatland” lidar) and along the slope (“hill” lidar) of a ridge to study the flow as it moved up and along the ridge towards turbine A08 under varying stability conditions. The lidars measured wind speed, direction and turbulence at ten measurement heights including ones equivalent to the turbine rotor-disk. Instrument placement is shown in Figures 1 and 2. The placement of the two lidars was based on wind direction measurements taken at the hill lidar location during summer of 2012. The predominant wind direction in 2013 was nearly identical to 2012 and the lidar locations proved optimal for capturing wind flow as it approached A08 from the southwest. SCADA data provided 10-minute nacelle wind speed and power data for the nearby turbines.

17 WIND ENERGY↗

Dynamic Analysis of Electrical Power Grid Delivery: Using Prime Mover Engines to Balance Dynamic Wind Turbine Output

This paper presents an investigation into integrated wind + combustion engine high penetration electrical generation systems. Renewable generation systems are now a reality of electrical transmission. Unfortunately, many of these renewable energy supplies are stochastic and highly dynamic. Conversely, the existing national grid has been designed for steady state operation. The research team has developed an algorithm to investigate the feasibility and relative capability of a reciprocating internal combustion engine to directly integrate with wind generation in a tightly coupled Hybrid Energy System. Utilizing the Idaho National Laboratory developed Phoenix Model Integration Platform, the research team has coupled demand data with wind turbine generation data and the Aspen Custom Modeler reciprocating engine electrical generator model to investigate the capability of reciprocating engine electrical generation to balance stochastic renewable energy.

17 WIND ENERGY↗

Electrical Power Grid Delivery Dynamic Analysis: Using Prime Mover Engines to Balance Dynamic Wind Turbine Output

This paper presents an investigation into integrated wind + combustion engine high penetration electrical generation systems. Renewable generation systems are now a reality of electrical transmission. Unfortunately, many of these renewable energy supplies are stochastic and highly dynamic. Conversely, the existing national grid has been designed for steady state operation. The research team has developed an algorithm to investigate the feasibility and relative capability of a reciprocating internal combustion engine to directly integrate with wind generation in a tightly coupled Hybrid Energy System. Utilizing the Idaho National Laboratory developed Phoenix Model Integration Platform, the research team has coupled demand data with wind turbine generation data and the Aspen Custom Modeler reciprocating engine electrical generator model to investigate the capability of reciprocating engine electrical generation to balance stochastic renewable energy.

17 WIND ENERGY↗

Aerodynamic and Aeroacoustic Tests of a Flatback Version of the DU97-W-300 Airfoil

Results from an experimental study of the aerodynamic and aeroacoustic properties of a ftatback version of the TU Delft DU97-W-300 airfoil are presented. Measurements were made for both the original DU97-W-300 and the flatback version. The chord Reynolds number varied from l.6 x 10 6 to 3.2 x 10 6 . The data were gathered in the Virginia Tech Stability Wind Tunnel, which includes a special aeroacoustic test section to enable measurements of airfoil self-noise. Corrected wind tunnel aerodynamic measurements for the DU97-W-300 are compared to previous solid wall wind tunnel data and are shown to give good agreement. Force coefficient and surface pressure distributions are compared for the flatback and the original airfoil for both free-transition and tripped boundary layer configurations. Aeroacoustic data are presented for the flatback airfoil, with a focus on the amplitude and frequency of noise associated with the vortex-shedding tone from the blunt trailing edge wake. The effect of a splitter plate trailing edge attachment on both drag and noise of the ftacback airfoil is also investigated.

17 WIND ENERGY↗

Wind Power Plant Prediction by Using Neural Networks

This paper introduces a method of short-term wind power prediction for a wind power plant by training neural networks based on historical data of wind speed and wind direction. The model proposed is shown to achieve a high accuracy with respect to the measured data.

17 WIND ENERGY↗