Search NASA⌕ Search

SEARCH · Search NASA

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

SU-E-T-208: Comparison of MR Image Quality of Various Brachytherapy Applicators for Cervical Cancer

Purpose: To compare the quality of Magnetic Resonance (MR) images of a recently-proposed novel direction-modulated brachytherapy (DMBT) tandem applicator against two conventional clinical applicators, using the current MRI clinical protocol. Methods: Three tandem applicators were compared: (1) tungsten-based DMBT applicator, (2) conventional plastic applicator and (3) conventional stainless steel applicator. Physical dimensions were 5.4, 3.8 and 3.2 for tandems (1), (2) and (3), respectively. Each applicator was placed in the same water-phantom and independently scanned using the same parameters and coil settings on a 1.5 T 450w GE scanner. Images were acquired using T2-weighted turbo-spin-echo (TSE) with 8-channel body coil. Acquisition parameters were TR/TE =7000/108 ms; acquisition matrix = 320 x 256; 30 slices with 4 mm thickness and 0.5 gap; pixel bandwidth = 122 Hz and voxel size = 0.5 x 0.625 mm2 and number of excitations (NEX) = 4. Multiple acquisitions were obtained in para-sagittal and para-axial views (with respect to the tandem axis) for each applicator. Diameters of the tandem were measured at multiple angles and multiple locations and compared to the physical dimensions of the corresponding tandems. Results: Minimal susceptibility artifact was observed with the DMBT and the plastic tandems. The stainless steel tandem produced significantly larger artifact than the first two tandems. The average diameter of the DMBT applicator measured 5.94 ± 0.3 mm. The average diameter of the plastic tandem measured 3.9 ± 0.1 mm. The maximum extent of artifact was 1.5 mm and 0.7 mm for DMBT and plastic tandems, respectively. The susceptibility artifact induced by the stainless steel tandem prevented the measurement of its diameter, and the edges of the tandem could not be identified in any acquisition. Conclusion: This work demonstrated that the plastic and the tungsten-based DMBT tandem applicators are both suitable for MRI-guided brachytherapy of cervical cancer.

60 APPLIED LIFE SCIENCES↗

SU-F-303-02: Achieving 4D MRI in Regular Breathing Cycle with Extended Acquisition Time of Dynamic MR Images

Purpose: The purpose of this study is to develop a technique to obtain four-dimensional (4D) magnetic resonance (MR) images that are more representative of a patient’s typical breathing cycle by utilizing an extended acquisition time while minimizing the image artifacts. Methods: The 4D MR data were acquired with the balanced steady state free precession in two-dimensional sagittal plane of view. Each slice was acquired repeatedly for about 15 s, thereby obtaining multiple images at each of the 10 phases in the respiratory cycle. This improves the probability that at least one of the images were acquired at the desired phase during a regular breathing cycle. To create optimal 4D MR images, an iterative approach was used to identify the set of images that yielded the highest slice-to-slice similarity. To assess the effectiveness of the approach, the data set was truncated into periods of 7 s (50 time points), 11 s (75 time points) and the full 15 s (100 time points). The 4D MR images were then sorted with data of the three different acquisition periods for comparison. Results: In general, the 4D MR images sorted using data from longer acquisition periods showed less mismatched artifacts. In addition, the normalized cross correlation (NCC) between slices of a 4D volume increases with increased acquisition period. The average NCC was 0.791 from the 7 s period, 0.794 from the 11 s period and 0.796 from the 15 s period. Conclusion: Our preliminary study showed that extending the acquisition time with the proposed sorting technique can improve image quality and reduce artifact presence in the 4D MR images. Data acquisition over two breathing cycles is a good trade-off between artifact reduction and scan time. This research was partially funded by the the Center for Radiation Oncology Research from UT MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

WE-EF-207-04: An Inter-Projection Sensor Fusion (IPSF) Approach to Estimate Missing Projection Signal in Synchronized Moving Grid (SMOG) System

Purpose: A synchronized moving grid (SMOG) has been proposed to reduce scatter and lag artifacts in cone beam computed tomography (CBCT). However, information is missing in each projection because certain areas are blocked by the grid. A previous solution to this issue is acquiring 2 complimentary projections at each position, which increases scanning time. This study reports our first Result using an inter-projection sensor fusion (IPSF) method to estimate missing projection in our prototype SMOG-based CBCT system. Methods: An in-house SMOG assembling with a 1:1 grid of 3 mm gap has been installed in a CBCT benchtop. The grid moves back and forth in a 3-mm amplitude and up-to 20-Hz frequency. A control program in LabView synchronizes the grid motion with the platform rotation and x-ray firing so that the grid patterns for any two neighboring projections are complimentary. A Catphan was scanned with 360 projections. After scatter correction, the IPSF algorithm was applied to estimate missing signal for each projection using the information from the 2 neighboring projections. Feldkamp-Davis-Kress (FDK) algorithm was applied to reconstruct CBCT images. The CBCTs were compared to those reconstructed using normal projections without applying the SMOG system. Results: The SMOG-IPSF method may reduce image dose by half due to the blocked radiation by the grid. The method almost completely removed scatter related artifacts, such as the cupping artifacts. The evaluation of line pair patterns in the CatPhan suggested that the spatial resolution degradation was minimal. Conclusion: The SMOG-IPSF is promising in reducing scatter artifacts and improving image quality while reducing radiation dose.

60 APPLIED LIFE SCIENCES↗

Compressed-sensing-based content-driven hierarchical reconstruction: Theory and application to C-arm cone-beam tomography

Purpose: This paper addresses the reconstruction of x-ray cone-beam computed tomography (CBCT) for interventional C-arm systems. Subsampling of CBCT is a significant issue with C-arms due to their slow rotation and to the low frame rate of their flat panel x-ray detectors. The aim of this work is to propose a novel method able to handle the subsampling artifacts generally observed with analytical reconstruction, through a content-driven hierarchical reconstruction based on compressed sensing. Methods: The central idea is to proceed with a hierarchical method where the most salient features (high intensities or gradients) are reconstructed first to reduce the artifacts these features induce. These artifacts are addressed first because their presence contaminates less salient features. Several hierarchical schemes aiming at streak artifacts reduction are introduced for C-arm CBCT: the empirical orthogonal matching pursuit approach with the ℓ{sub 0} pseudonorm for reconstructing sparse vessels; a convex variant using homotopy with the ℓ{sub 1}-norm constraint of compressed sensing, for reconstructing sparse vessels over a nonsparse background; homotopy with total variation (TV); and a novel empirical extension to nonlinear diffusion (NLD). Such principles are implemented with penalized iterative filtered backprojection algorithms. For soft-tissue imaging, the authors compare the use of TV and NLD filters as sparsity constraints, both optimized with the alternating direction method of multipliers, using a threshold for TV and a nonlinear weighting for NLD. Results: The authors show on simulated data that their approach provides fast convergence to good approximations of the solution of the TV-constrained minimization problem introduced by the compressed sensing theory. Using C-arm CBCT clinical data, the authors show that both TV and NLD can deliver improved image quality by reducing streaks. Conclusions: A flexible compressed-sensing-based algorithmic approach is proposed that is able to accommodate for a wide range of constraints. It is successfully applied to C-arm CBCT images that may not be so well approximated by piecewise constant functions.

60 APPLIED LIFE SCIENCES↗

Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT

Purpose: The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. Methods: This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numerical simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. Results: The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. Conclusions: The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can potentially improve the rendering of spatial features and reduce cone-beam optical CT artifacts.

60 APPLIED LIFE SCIENCES↗

Penalized maximum likelihood reconstruction for x-ray differential phase-contrast tomography

Purpose: The purpose of this work is to propose a cost function with regularization to iteratively reconstruct attenuation, phase, and scatter images simultaneously from differential phase contrast (DPC) acquisitions, without the need of phase retrieval, and examine its properties. Furthermore this reconstruction method is applied to an acquisition pattern that is suitable for a DPC tomographic system with continuously rotating gantry (sliding window acquisition), overcoming the severe smearing in noniterative reconstruction. Methods: We derive a penalized maximum likelihood reconstruction algorithm to directly reconstruct attenuation, phase, and scatter image from the measured detector values of a DPC acquisition. The proposed penalty comprises, for each of the three images, an independent smoothing prior. Image quality of the proposed reconstruction is compared to images generated with FBP and iterative reconstruction after phase retrieval. Furthermore, the influence between the priors is analyzed. Finally, the proposed reconstruction algorithm is applied to experimental sliding window data acquired at a synchrotron and results are compared to reconstructions based on phase retrieval. Results: The results show that the proposed algorithm significantly increases image quality in comparison to reconstructions based on phase retrieval. No significant mutual influence between the proposed independent priors could be observed. Further it could be illustrated that the iterative reconstruction of a sliding window acquisition results in images with substantially reduced smearing artifacts. Conclusions: Although the proposed cost function is inherently nonconvex, it can be used to reconstruct images with less aliasing artifacts and less streak artifacts than reconstruction methods based on phase retrieval. Furthermore, the proposed method can be used to reconstruct images of sliding window acquisitions with negligible smearing artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clinical introduction of image lag correction for a cone beam CT system

Purpose: Image lag in the flat-panel detector used for Linac integrated cone beam computed tomography (CBCT) has a degrading effect on CBCT image quality. The most prominent visible artifact is the presence of bright semicircular structure in the transverse view of the scans, known also as radar artifact. Several correction strategies have been proposed, but until now the clinical introduction of such corrections remains unreported. In November 2013, the authors have clinically implemented a previously proposed image lag correction on all of their machines at their main site in Amsterdam. The purpose of this study was to retrospectively evaluate the effect of the correction on the quality of CBCT images and evaluate the required calibration frequency. Methods: Image lag was measured in five clinical CBCT systems (Elekta Synergy 4.6) using an in-house developed beam interrupting device that stops the x-ray beam midway through the data acquisition of an unattenuated beam for calibration. A triple exponential falling edge response was fitted to the measured data and used to correct image lag from projection images with an infinite response. This filter, including an extrapolation for saturated pixels, was incorporated in the authors’ in-house developed clinical CBCT reconstruction software. To investigate the short-term stability of the lag and associated parameters, a series of five image lag measurement over a period of three months was performed. For quantitative analysis, the authors have retrospectively selected ten patients treated in the pelvic region. The apparent contrast was quantified in polar coordinates for scans reconstructed using the parameters obtained from different dates with and without saturation handling. Results: Visually, the radar artifact was minimal in scans reconstructed using image lag correction especially when saturation handling was used. In patient imaging, there was a significant reduction of the apparent contrast from 43 ± 16.7 to 15.5 ± 11.9 HU without the saturation handling and to 9.6 ± 12.1 HU with the saturation handling, depending on the date of the calibration. The image lag correction parameters were stable over a period of 3 months. The computational load was increased by approximately 10%, not endangering the fast in-line reconstruction. Conclusions: The lag correction was successfully implemented clinically and removed most image lag artifacts thus improving the image quality. Image lag correction parameters were stable for 3 months indicating low frequency of calibration requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improved tissue assignment using dual-energy computed tomography in low-dose rate prostate brachytherapy for Monte Carlo dose calculation

Purpose: An improvement in tissue assignment for low-dose rate brachytherapy (LDRB) patients using more accurate Monte Carlo (MC) dose calculation was accomplished with a metallic artifact reduction (MAR) method specific to dual-energy computed tomography (DECT). Methods: The proposed MAR algorithm followed a four-step procedure. The first step involved applying a weighted blend of both DECT scans (I {sub H/L}) to generate a new image (I {sub Mix}). This action minimized Hounsfield unit (HU) variations surrounding the brachytherapy seeds. In the second step, the mean HU of the prostate in I {sub Mix} was calculated and shifted toward the mean HU of the two original DECT images (I {sub H/L}). The third step involved smoothing the newly shifted I {sub Mix} and the two original I {sub H/L}, followed by a subtraction of both, generating an image that represented the metallic artifact (I {sub A,(H/L)}) of reduced noise levels. The final step consisted of subtracting the original I {sub H/L} from the newly generated I {sub A,(H/L)} and obtaining a final image corrected for metallic artifacts. Following the completion of the algorithm, a DECT stoichiometric method was used to extract the relative electronic density (ρ{sub e}) and effective atomic number (Z {sub eff}) at each voxel of the corrected scans. Tissue assignment could then be determined with these two newly acquired physical parameters. Each voxel was assigned the tissue bearing the closest resemblance in terms of ρ{sub e} and Z {sub eff}, comparing with values from the ICRU 42 database. A MC study was then performed to compare the dosimetric impacts of alternative MAR algorithms. Results: An improvement in tissue assignment was observed with the DECT MAR algorithm, compared to the single-energy computed tomography (SECT) approach. In a phantom study, tissue misassignment was found to reach 0.05% of voxels using the DECT approach, compared with 0.40% using the SECT method. Comparison of the DECT and SECT D {sub 90} dose parameter (volume receiving 90% of the dose) indicated that D {sub 90} could be underestimated by up to 2.3% using the SECT method. Conclusions: The DECT MAR approach is a simple alternative to reduce metallic artifacts found in LDRB patient scans. Images can be processed quickly and do not require the determination of x-ray spectra. Substantial information on density and atomic number can also be obtained. Furthermore, calcifications within the prostate are detected by the tissue assignment algorithm. This enables more accurate, patient-specific MC dose calculations.

60 APPLIED LIFE SCIENCES↗

SU-D-206-04: Iterative CBCT Scatter Shading Correction Without Prior Information

Purpose: To estimate and remove the scatter contamination in the acquired projection of cone-beam CT (CBCT), to suppress the shading artifacts and improve the image quality without prior information. Methods: The uncorrected CBCT images containing shading artifacts are reconstructed by applying the standard FDK algorithm on CBCT raw projections. The uncorrected image is then segmented to generate an initial template image. To estimate scatter signal, the differences are calculated by subtracting the simulated projections of the template image from the raw projections. Since scatter signals are dominantly continuous and low-frequency in the projection domain, they are estimated by low-pass filtering the difference signals and subtracted from the raw CBCT projections to achieve the scatter correction. Finally, the corrected CBCT image is reconstructed from the corrected projection data. Since an accurate template image is not readily segmented from the uncorrected CBCT image, the proposed scheme is iterated until the produced template is not altered. Results: The proposed scheme is evaluated on the Catphan©600 phantom data and CBCT images acquired from a pelvis patient. The result shows that shading artifacts have been effectively suppressed by the proposed method. Using multi-detector CT (MDCT) images as reference, quantitative analysis is operated to measure the quality of corrected images. Compared to images without correction, the method proposed reduces the overall CT number error from over 200 HU to be less than 50 HU and can increase the spatial uniformity. Conclusion: An iterative strategy without relying on the prior information is proposed in this work to remove the shading artifacts due to scatter contamination in the projection domain. The method is evaluated in phantom and patient studies and the result shows that the image quality is remarkably improved. The proposed method is efficient and practical to address the poor image quality issue of CBCT images. This work is supported by the Zhejiang Provincial Natural Science Foundation of China (Grant No. LR16F010001), National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917).

60 APPLIED LIFE SCIENCES↗

SU-D-206-07: CBCT Scatter Correction Based On Rotating Collimator

Purpose: Scatter correction in cone-beam computed tomography (CBCT) has obvious effect on the removal of image noise, the cup artifact and the increase of image contrast. Several methods using a beam blocker for the estimation and subtraction of scatter have been proposed. However, the inconvenience of mechanics and propensity to residual artifacts limited the further evolution of basic and clinical research. Here, we propose a rotating collimator-based approach, in conjunction with reconstruction based on a discrete Radon transform and Tchebichef moments algorithm, to correct scatter-induced artifacts. Methods: A rotating-collimator, comprising round tungsten alloy strips, was mounted on a linear actuator. The rotating-collimator is divided into 6 portions equally. The round strips space is evenly spaced on each portion but staggered between different portions. A step motor connected to the rotating collimator drove the blocker to around x-ray source during the CBCT acquisition. The CBCT reconstruction based on a discrete Radon transform and Tchebichef moments algorithm is performed. Experimental studies using water phantom and Catphan504 were carried out to evaluate the performance of the proposed scheme. Results: The proposed algorithm was tested on both the Monte Carlo simulation and actual experiments with the Catphan504 phantom. From the simulation result, the mean square error of the reconstruction error decreases from 16% to 1.18%, the cupping (τcup) from 14.005% to 0.66%, and the peak signal-to-noise ratio increase from 16.9594 to 31.45. From the actual experiments, the induced visual artifacts are significantly reduced. Conclusion: We conducted an experiment on CBCT imaging system with a rotating collimator to develop and optimize x-ray scatter control and reduction technique. The proposed method is attractive in applications where a high CBCT image quality is critical, for example, dose calculation in adaptive radiation therapy. We want to thank Dr. Lei Xing and Dr. Yong Yang in the Stanford University School of Medicine for this work. This work was jointly supported by NSFC (61471226), Natural Science Foundation for Distinguished Young Scholars of Shandong Province (JQ201516), and China Postdoctoral Science Foundation (2015T80739, 2014M551949).

60 APPLIED LIFE SCIENCES↗

SU-F-J-76: Evaluation of the Performance of Different Deformable Image Registration Algorithms in Helical, Axial and Cone-Beam CT Images of a Mobile Phantom

Purpose: To investigate quantitatively the performance of different deformable-image-registration algorithms (DIR) with helical (HCT), axial (ACT) and cone-beam CT (CBCT) by evaluating the variations in the CT-numbers and lengths of targets moving with controlled motion-patterns. Methods: Four DIR-algorithms including demons, fast-demons, Horn-Schunk and Locas-Kanade from the DIRART-software are used to register CT-images of a mobile-phantom. A mobile-phantom is scanned with different imaging techniques that include helical, axial and cone-beam CT. The phantom includes three targets with different lengths that are made from water-equivalent material and inserted in low-density-foam which is moved with adjustable motion-amplitudes and frequencies. Results: Most of the DIR-algorithms are able to produce the lengths of the stationary-targets, however, they do not produce the CT-number values in CBCT. The image-artifacts induced by motion are more regular in CBCT imaging where the mobile-target elongation increases linearly with motion-amplitude. In ACT and HCT, the motion-artifacts are irregular where some mobile -targets are elongated or shrunk depending on the motion-phase during imaging. The DIR-algorithms are successful in deforming the images of the mobile-targets to the images of the stationary-targets producing the CT-number values and length of the target for motion-amplitudes < 20 mm. Similarly in ACT, all DIR-algorithms produced the actual CT-number and length of the stationary-targets for motion-amplitudes < 15 mm. As stronger motion-artifacts are induced in HCT and ACT, DIR-algorithms fail to produce CT-values and shape of the stationary-targets and fast-demons-algorithm has worst performance. Conclusion: Most of DIR-algorithms produce the CT-number values and lengths of the stationary-targets in HCT and ACT images that has motion-artifacts induced by small motion-amplitudes. As motion-amplitudes increase, the DIR-algorithms fail to deform mobile-target images to the stationary-images in HCT and ACT. In CBCT, DIR-algorithms are successful in producing length and shape of the stationary-targets, however, they fail to produce the accurate CT-number level.

60 APPLIED LIFE SCIENCES↗

Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging

Purpose: The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. Methods: Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisition protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP maps were generated from the dynamic contrast-enhanced (DCE) heart images taken at baseline and three weeks after the ischemic insult. Results: Their results showed that the phantom and animal images acquired with the CT platform were minimally affected by image noise and artifacts. For the beam-hardening phantom study, changes in water HU in the wall surrounding the heart chambers greatly reduced from >±30 to ≤ ± 5 HU at all kVp settings except one region at 100 kVp (7 HU). For the cone-beam phantom study, differences in mean water HU from the central slice were less than 5 HU at two peripheral slices with each 4 cm away from the central slice. These findings were reproducible in the pig DCE images at two peripheral slices that were 6 cm away from the central slice. For the partial-scan phantom study, standard deviations of the mean water HU in 10 successive partial scans were less than 5 HU at the central slice. Similar observations were made in the pig DCE images at two peripheral slices with each 6 cm away from the central slice. For the image noise phantom study, CNRs in the ASiR-V images were statistically higher (p < 0.05) than the non-ASiR-V images at all kVp settings. MP maps generated from the porcine DCE images were in excellent quality, with the ischemia in the LAD territory clearly seen in the three orthogonal views. Conclusions: The study demonstrates that this CT system can provide accurate and reproducible CT numbers during cardiac gated acquisitions across a wide axial field of view. This CT number fidelity will enable this imaging tool to assess contrast enhancement, potentially providing valuable added information beyond anatomic evaluation of coronary stenoses. Furthermore, their results collectively suggested that the 100 kVp/25 mAs protocol run on this CT system provides sufficient image accuracy at a low radiation dose (<3 mSv) for whole-heart quantitative CT MP imaging.

60 APPLIED LIFE SCIENCES↗

Effects of error, chimera, bias, and GC content on the accuracy of amplicon sequencing

ABSTRACT Targeted amplicon sequencing is widely used in microbial ecology studies. However, sequencing artifacts and amplification biases are of great concern. To identify sources of these artifacts, a systematic analysis was performed using mock communities comprised of 16S rRNA genes from 33 bacterial strains. Our results indicated that while sequencing errors were generally isolated to low-abundance operational taxonomic units, chimeric sequences were a major source of artifacts. Singleton and doubleton sequences were primarily chimeras. Formation of chimeric sequences was significantly correlated with the GC content of the targeted sequences. Low-GC-content mock community members exhibited lower rates of chimeric sequence formation. GC content also had a large impact on sequence recovery. The quantitative capacity was notably limited, with substantial recovery variations and weak correlation between anticipated and observed strain abundances. The mock community strains with higher GC content had higher recovery rates than strains with lower GC content. Amplification bias was also observed due to the differences in primer affinity. A two-step PCR strategy reduced the number of chimeric sequences by half. In addition, comparative analyses based on the mock communities showed that several widely used sequence processing pipelines/methods, including DADA2, Deblur, UCLUST, UNOISE, and UPARSE, had different advantages and disadvantages in artifact removal and rare species detection. These results are important for improving sequencing quality and reliability and developing new algorithms to process targeted amplicon sequences. IMPORTANCE Amplicon sequencing of targeted genes is the predominant approach to estimate the membership and structure of microbial communities. However, accurate reconstruction of community composition is difficult due to sequencing errors, and other methodological biases and effective approaches to overcome these challenges are essential. Using a mock community of 33 phylogenetically diverse strains, this study evaluated the effect of GC content on sequencing results and tested different approaches to improve overall sequencing accuracy while characterizing the pros and cons of popular amplicon sequence data processing approaches. The sequencing results from this study can serve as a benchmarking data set for future algorithmic improvements. Furthermore, the new insights on sequencing error, chimera formation, and GC bias from this study will help enhance the quality of amplicon sequencing studies and support the development of new data analysis approaches.

59 BASIC BIOLOGICAL SCIENCES↗

ScholarGuard

The ScholarGuard framework aims to address the gap in archiving and preservation efforts for scholarly artifacts beyond traditional research papers, such as software source code, datasets, presentation slides, workflows, protocols, videos, and more. It introduces a prototype system designed to automatically track researchers' outputs across various scholarly productivity portals on the open web, including platforms like GitHub, Slideshare, Figshare, and Wikipedia. The system detects the availability of new scholarly artifacts and applies modern web archiving technology to create a durable archival record, including high-level metadata for each artifact. This metadata is displayed within the system, linking both to the live version and the archived version of the resource, ensuring long-term accessibility and preservation of diverse research outputs. The software serves as a critical tool for preserving the broader spectrum of scholarly contributions, facilitating visibility, searchability, and long-term access to research artifacts beyond the traditional scope of journal publications.

Balakireva, Lyudmila↗

New Molecular Reporters for Rapid Protein Folding Assays

The GFP folding reporter assay uses a C-terminal GFP fusion to report on the folding success of upstream fused polypeptides. The GFP folding assay is widely-used for screening protein variants with improved folding and solubility, but truncation artifacts may arise during evolution, i.e. from de novo internal ribosome entry sites. One way to reduce such artifacts would be to insert target genes within the scaffolding of GFP circular permuted variants. Circular permutants of fluorescent proteins often misfold and are non-fluorescent, and do not readily tolerate fused polypeptides within the fluorescent protein scaffolding. To overcome these limitations, and to increase the dynamic range for reporting on protein misfolding, we have created eight GFP insertion reporters with different sensitivities to protein misfolding using chimeras of two previously described GFP variants, the GFP folding reporte and the robustly-folding ‘‘superfolder’’ GFP. We applied this technology to engineer soluble variants of Rv0113, a protein from Mycobacterium tuberculosis initially expressed as inclusion bodies in Escherichia coli. Using GFP insertion reporters with increasing stringency for each cycle of mutagenesis and selection led to a variant that produced large amounts of soluble protein at 37°C in Escherichia coli. The new reporter constructs discriminate against truncation artifacts previously isolated during directed evolution of Rv0113 using the original C-terminal GFP folding reporter. Using GFP insertion reporters with variable stringency should prove useful for engineering protein variants with improved folding and solubility, while reducing the number of artifacts arising from internal cryptic ribosome initiation sites.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic Networks Experiment FY18 - Quality Control Focus Area Efforts

The availability of data whose quality is fittingly labeled is of tantamount importance to signal detection and all other downstream signal processing operations. Without identification, the goals of low yield nuclear monitoring cannot reach their full potential. A fundamental question that remains is the knowledge of the capability gaps that prevent us from using open network data. With these new channels, we will need better understanding of the frequency, type, severity, and impact of artifacts when compared to conventional networks. Moreover, beyond a simple quality label, thresholds for acceptable use of the data will need to be established, likely on a use case by use case basis. Finally, orders of magnitude more data with an at-best static analyst pool size means that quality artifacts must be identified with as little human interaction as possible. Automated methodologies must be developed to account for the scale of the problem when ad hoc networks are candidates for processing. At the same time that “data wealth” provides more opportunity for signal exploitation, the introduction of ad hoc networks introduces an increased risk quality issues in both sensor value and metadata issues. The artifacts shown below are examples of some sensor-based quality issues that impair downstream processing. The machine learning model used in this project was able to identify the artifacts that produce these spurious correlations, significantly improving analyst productivity.

97 MATHEMATICS AND COMPUTING↗

Investigation of Computational Corrections to X-Ray Computed Tomography for Dimensional Metrology of Complex Additively Manufactured Parts

X-ray computed tomography (CT) is a nondestructive evaluation technique that may be used to image complex internal features without the line-of-sight restrictions inherent in conventional optical and contact (stylus) metrology instrumentation. Applications of CT metrology include material defects (porosity), dimensions and surface texture. However, scan artifacts, such as streaking, caused primarily by beam hardening and scatter, limit the accuracy of CTbased metrology. Reduction of these artifacts would improve the accuracy material properties and dimensional metrology information. This paper reports on the development of additively manufactured (AM) Ti5553 and 316L measurement phantoms with integral lattice (lattice) structures specifically designed to exhibit these artifacts. The phantoms were scanned in three CT systems and a scanning-probe CMM measurement. Surfaces generated from uncorrected CT data exhibited “dimple” defects that are not present in the CMM measurement. Correction methods were developed in Livermore Tomography Tools (LTT) software and this paper reports on the successful correction of these artifacts. This work is expected to have application in areas where characterization of defects, dimensions and surface texture using CT are critical.

42 ENGINEERING↗

Macro Supply Chain Lifecycle Decision Analytics

This report summarizes a two-year LDRD project that investigated the problem of representing complex supply chains, identifying the worst risks and evaluating mitigation options. Our team developed a framework that includes a representation for business processes, risk assessment questions, risk indicators and methods for analyzing and summarizing the data. In our approach, the Process Matrix represents an overall supply chain for an end product in a high-level, tabular form. It connects the various touch-points of a business process including people, external vendors, tools, storage locations and transportation services while capturing the flow of both physical and intellectual artifacts. We believe these direct connections are exactly the things that a process owner can typically control. These material flows (both physical and intellectual) are also represented in a graph. This enables us to use graph-oriented analysis such as fault tree analysis and attack graph generation. Our approach is top-down, which helps users to get a more holistic understanding for a given amount of resources. Understanding the provenance of materials is difficult and it is easy to exhaust the analysts' resources. Rather than a tool to do vendor analysis or product comparison, our framework enables an enterprise-level analysis. The risk assessment questionnaires have a varying levels of detail and cover various aspects of the supply chain such as process steps, artifacts, suppliers, etc. and connections between these aspects such as artifact-storage, artifact-supplier, etc. Each question is further associated with one of seven risk indicators which can be used to summarize the risk. These risk indicators can also be weighted to reflect a user's concerns. We have successfully applied our framework to several use cases in various stages of its development and provided valuable insights to our partners, but it can also be applied to other complex systems outside of the supply chain security problem.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗