Search NASA⌕ Search

SEARCH · Search NASA

Results for “AUTOS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Deterioration in brain and heart functions following a single sub-lethal (0.8 LCt{sub 50}) inhalation exposure of rats to sarin vapor:

The main injuries among victims of the terrorist act in the Tokyo subway resulted from sub-lethal inhalation and whole body exposure to sarin vapor. In order to study the long term effects of such exposure and to simulate these conditions, freely moving rats were exposed to sarin vapor (27.2 {+-} 1.7 {mu}g/l) for 10 min. About 50% of the rats showed no overt symptoms and the rest had mild to moderate clinical symptoms that subsided within 4 h following exposure. A reduction of weight was noted during the first 3 days with full recovery on the 4th day. Rat's heart was challenged with epinephrine 1 and 6 months post exposure. A significant reduction in the threshold for epinephrine-induced arrhythmia (EPIA) was noted in rats exposed to sarin. A time dependent increase in the kD and Bmax values of muscarinic auto receptors (M2) was recorded in the rat's cortex and striatum. No changes were recorded in the rats' brain trans locator protein (TSPO) levels, concomitant with no observed changes in the animals' performance in A Morris water maze test. A significant increase in open field activity was noted 6 months following exposure to sarin vapor as well as a significant decrease in prostaglandin E{sub 2} (PGE{sub 2}) production in the brain. It is speculated that down regulation of the M2 auto receptor function, caused hyper reactivity of the cholinergic system which leads to the changes described above. The continuous reduction in M2 auto-receptor system through an unknown mechanism may be the cause for long lasting decline in sarin-exposed casualties' health.

60 APPLIED LIFE SCIENCES↗

Planck 2013 results. XXX. Cosmic infrared background measurements and implications for star formation

We present new measurements of cosmic infrared background (CIB) anisotropies using Planck . Combining HFI data with IRAS, the angular auto-and cross-frequency power spectrum is measured from 143 to 3000 GHz, and the auto-bispectrum from 217 to 545 GHz. The total areas used to compute the CIB power spectrum and bispectrum are about 2240 and 4400 deg 2 , respectively. After careful removal of the contaminants (cosmic microwave background anisotropies, Galactic dust, and Sunyaev-Zeldovich emission), and a complete study of systematics, the CIB power spectrum is measured with unprecedented signal to noise ratio from angular multipoles ℓ ~ 150 to 2500. The bispectrum due to the clustering of dusty, star-forming galaxies is measured from ℓ ~ 130 to 1100, with a total signal to noise ratio of around 6, 19, and 29 at 217, 353, and 545 GHz, respectively. Two approaches are developed for modelling CIB power spectrum anisotropies. The first approach takes advantage of the unique measurements by Planck at large angular scales, and models only the linear part of the power spectrum, with a mean bias of dark matter haloes hosting dusty galaxies at a given redshift weighted by their contribution to the emissivities. The second approach is based on a model that associates star-forming galaxies with dark matter haloes and their subhaloes, using a parametrized relation between the dust-processed infrared luminosity and (sub-)halo mass. The two approaches simultaneously fit all auto-and cross-power spectra very well. We find that the star formation history is well constrained up to redshifts around 2, and agrees with recent estimates of the obscured star-formation density using Spitzer and Herschel . However, at higher redshift, the accuracy of the star formation history measurement is strongly degraded by the uncertainty in the spectral energy distribution of CIB galaxies. We also find that the mean halo mass which is most efficient at hosting star formation is log (M eff /M ⊙ ) = 12.6 and that CIB galaxies have warmer temperatures as redshift increases. The CIB bispectrum is steeper than that expected from the power spectrum, although well fitted by a power law; this gives some information about the contribution of massive haloes to the CIB bispectrum. Finally, we show that the same halo occupation distribution can fit all power spectra simultaneously. The precise measurements enabled by Planck pose new challenges for the modelling of CIB anisotropies, indicating the power of using CIB anisotropies to understand the process of galaxy formation.

79 ASTRONOMY AND ASTROPHYSICS↗

The DESI DR1 peculiar velocity survey: Growth rate measurements from the galaxy power spectrum

The large-scale structure of the Universe and its evolution encapsulate a wealth of cosmological information. A powerful means of unlocking this knowledge lies in measuring the auto-power spectrum and/or the cross-power spectrum of the galaxy density and momentum fields, followed by the estimation of cosmological parameters based on these spectrum measurements. In this study, we generalize the cross-power spectrum model to accommodate scenarios in which the density and momentum fields are derived from distinct galaxy surveys. The growth rate of the large-scale structures of the Universe, commonly represented as fσ 8 , was extracted by jointly fitting the monopole and quadrupole moments of the auto-density power spectrum, the monopole of the auto-momentum power spectrum, and the dipole of the cross-power spectrum. Our estimators, theoretical models, and parameter-fitting framework were tested using mocks, confirming their robustness and accuracy in retrieving the fiducial growth rate from simulation. These techniques were then applied to analyse the power spectrum of the DESI Bright Galaxy Survey and Peculiar Velocity Survey. The fit result of the growth rate is fσ8 = 0.440$^{+0.080}_{−0.096}$ at effective redshift zeff = 0.07. By synthesizing the fitting outcomes from correlation functions, maximum likelihood estimation, and the power spectrum, a consensus value is yielded of fσ 8 (z eff = 0.07) = 0.450$^{+0.055}_{−0.055}$, and correspondingly we obtain γ = 0.580$^{+0.110}_{−0.110}$, Ω m = 0.301$^{+0.011}_{−0.011}$, and σ 8 = 0.834$^{+0.032}_{−0.032}$. The measured fσ8 and γ are consistent with the prediction of the Λ cold dark matter model and general relativity.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Group-III precursors on unintentional gallium incorporation during epitaxial growth of InAlN layers by metalorganic chemical vapor deposition

Unintentional incorporation of gallium (Ga) in InAlN layers grown with different molar flow rates of Group-III precursors by metalorganic chemical vapor deposition has been experimentally investigated. The Ga mole fraction in the InAl(Ga)N layer was increased significantly with the trimethylindium (TMIn) flow rate, while the trimethylaluminum flow rate controls the Al mole fraction. The evaporation of metallic Ga from the liquid phase eutectic system between the pyrolized In from injected TMIn and pre-deposited metallic Ga was responsible for the Ga auto-incorporation into the InAl(Ga)N layer. The theoretical calculation on the equilibrium vapor pressure of liquid phase Ga and the effective partial pressure of Group-III precursors based on growth parameters used in this study confirms the influence of Group-III precursors on Ga auto-incorporation. More Ga atoms can be evaporated from the liquid phase Ga on the surrounding surfaces in the growth chamber and then significant Ga auto-incorporation can occur due to the high equilibrium vapor pressure of Ga comparable to effective partial pressure of input Group-III precursors during the growth of InAl(Ga)N layer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterizing phonon dynamics using stochastic sampling

Predicting phonon relaxation time from molecular dynamics (MD) requires a long simulation time to compute the mode energy auto-correlation function. Here, we present an alternative approach to infer the phonon life-time from an approximate form of the energy auto-correlation function. The method requires as an input a set of sampled equilibrium configurations. A stochastic sampling method is used to generate the equilibrium configurations. We consider a truncated Taylor series expansion of the phonon energy auto-correlation function. The different terms in the truncated correlation function are obtained using the stochastic sampling approach. The expansion terms, thus, obtained are in good agreement with the corresponding values obtained using MD. We then use the approximate function to compute the phonon relaxation time. The relaxation time computed using this method is compared with that obtained from the exact correlation function. The two values are in agreement with each other.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spitzer bright, ultravista faint sources in cosmos: The contribution to the overall population of massive galaxies at z = 3–7

We have analyzed a sample of 574 Spitzer 4.5 μm selected galaxies with [4.5]<23 and K{sub s}{sup auto}>24 (AB) over the UltraVISTA ultradeep COSMOS field. Our aim is to investigate whether these mid-infrared (mid-IR) bright, near-infrared (near-IR) faint sources contribute significantly to the overall population of massive galaxies at redshifts z⩾3. By performing a spectral energy distribution (SED) analysis using up to 30 photometric bands, we have determined that the redshift distribution of our sample peaks at redshifts z≈2.5–3.0, and ∼32% of the galaxies lie at z⩾3. We have studied the contribution of these sources to the galaxy stellar mass function (GSMF) at high redshifts. We found that the [4.5]<23, K{sub s}{sup auto}>24 galaxies produce a negligible change to the GSMF previously determined for K{sub s}{sup auto}<24 sources at 3⩽z<4, but their contribution is more important at 4⩽z<5, accounting for ≳50% of the galaxies with stellar masses M{sub st}≳6×10{sup 10} M{sub ⊙}. We also constrained the GSMF at the highest-mass end (M{sub st}≳2×10{sup 11} M{sub ⊙}) at z⩾5. From their presence at 5⩽z<6 and virtual absence at higher redshifts, we can pinpoint quite precisely the moment of appearance of the first most massive galaxies as taking place in the ∼0.2 Gyr of elapsed time between z∼6 and z∼5. Alternatively, if very massive galaxies existed earlier in cosmic time, they should have been significantly dust-obscured to lie beyond the detection limits of current, large-area, deep near-IR surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Peculiar velocities in redshift space: formalism, N-body simulations and perturbation theory

Direct measurements of peculiar velocities of galaxies and clusters of galaxies can in principle provide explicit information on the three dimensional mass distribution, but this information is modulated by the fact that velocity field is sampled at galaxy positions, and is thus probing galaxy momentum. We derive expressions for the cross power spectrum between the density and momentum field and the auto spectrum of the momentum field in redshift space, by extending the distribution function method to these statistics. The resulting momentum cross and auto power spectra in redshift space are expressed as infinite sums over velocity moment correlators in real space, as is the case for the density power spectrum in redshift space. We compute each correlator using Eulerian perturbation theory (PT) and halo biasing model and compare the resulting redshift-space velocity statistics to those measured from N-body simulations for both dark matter and halos. We find that in redshift space linear theory predictions for the density-momentum cross power spectrum as well as for the momentum auto spectrum fail to predict the N-body results at very large scales. On the other hand, our nonlinear PT prediction for these velocity statistics, together with real-space power spectrum for dark matter from simulations, improves the accuracy for both dark matter and halos. We also present the same analysis in configuration space, computing the redshift-space pairwise mean infall velocities and velocity correlation function and compare to nonlinear PT.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmology from Planck CMB lensing and DESI DR1 quasar tomography

We present a measurement of the amplitude of matter fluctuations over the redshift range 0.8 ≤ z ≤ 3.5 from the cross correlation of over 1.2 million spectroscopic quasars selected by the Dark Energy Spectroscopic Instrument (DESI) across 7,200 deg 2 (∼ 170 quasars/deg 2 ) and Planck PR4 (NPIPE) cosmic microwave background (CMB) lensing maps. We perform a tomographic measurement in three bins centered at effective redshiftsz=1.44, 2.27 and 2.75, which have ample overlap with the CMB lensing kernel. From a joint fit using the angular clustering of all three redshift bins (auto and cross-spectra), and including an Q m prior from DESI DR1 baryon acoustic oscillations to break the $Ω_{m}-σ_{8}$ degeneracy, we constrain the amplitude of matter fluctuations in the matter-dominated regime to be $σ_{8}=0.929^{+0.059}_{-0.074}$ and $S_{8}≡σ_{8}(Ω_m/0.3)^{0.5} = 0.922^{+0.059}_{-0.073}$. We provide a growth of structure measurement with the largest spectroscopic quasar sample to date at high redshift, which is ∼ 1.5σ higher than predictions from ΛCDM fits to measurements of the primary CMB from Planck PR4. The cross-correlation between PR4 lensing maps and DESI DR1 quasars is detected with a signal-to-noise ratio of 21.7 and the quasar auto-correlation at 27.2 for the joint analysis of all redshift bins. We combine our measurement with the CMB lensing auto-spectrum from the ground-based Atacama Cosmology Telescope (ACT DR6) and Planck PR4 to perform a sound-horizon-free measurement of the Hubble constant, yielding $H_{0}=69.1^{+2.2}_{-2.6} {\rm \ km\ s}^{-1}{\rm Mpc}^{-1}$ through its sensitivity to the matter-radiation equality scale.

baryon acoustic oscillations↗

Mitigating foreground bias to the CMB lensing power spectrum for a CMB-HD survey

A promising way to measure the distribution of matter on small scales (k~10 h Mpc –1 ) is to use gravitational lensing of the cosmic microwave background (CMB). CMB-HD, a proposed high-resolution, low-noise millimeter survey over half the sky, can measure the CMB lensing auto spectrum on such small scales enabling measurements that can distinguish between a cold dark matter (CDM) model and alternative models designed to solve problems with CDM on small scales. However, extragalactic foregrounds can bias the CMB lensing auto spectrum if left untreated. Here, we present a foreground mitigation strategy that provides a path to reduce the bias from two of the most dominant foregrounds, the thermal Sunyaev-Zel’dovich effect and the cosmic infrared background. Given the level of realism included in our analysis, we find that the thermal Sunyaev-Zel’dovich alone and the cosmic infrared background alone bias the lensing auto spectrum by 0.6σ and 1.1σ, respectively, in the lensing multipole range of Lϵ[5000,20000] for a CMB-HD survey; combined these foregrounds yield a bias of only 1.3σ. Including these foregrounds, we also find that a CMB-HD survey can distinguish between a CDM model and a 10 –22 eV fuzzy dark matter model at the 5σ level. These results provide an important step in demonstrating that foreground contamination can be sufficiently reduced to enable a robust measurement of the small-scale matter power spectrum with CMB-HD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic Generation of High-Performance Convolution Kernels on ARM CPUs for Deep Learning

In this work, we present FastConv, a template-based code auto-generation open source library that can automatically generate high-performance deep learning convolution kernels of arbitrary matrices/tensors shapes. FastConv is based on the Winograd algorithm, which is reportedly the highest performing algorithm for the time-consuming convolution layers of convolutional neural networks. ARM CPUs cover a wide range designs and specifications, from embedded devices to HPC-grade CPUs. The leads to the dilemma of how to consistently optimize Winograd-based convolution solvers for convolution layers of different shapes. FastConv addresses this problem by using templates to auto-generate multiple shapes of tuned kernels variants suitable for skinny tall matrices. As a performance portable library, FastConv transparently searches for the best combination of kernel shapes, cache tiles, scheduling of loop orders, packing strategies, access patterns, and online/offline computations. Auto-tuning is used to search the parameter configuration space for the best performance for a given target architecture and problem size. The experiments with layer-wise evaluation on the VGG--16 model confirms a 1.25x performance gains is got by tuning the Winograd library. Integrated comparison results shows 1.02x to 1.40x, 1.14x to 2.17x, and 1.22x and 2.48x speedup is achieved over NNPACK, Arm NN, and FeatherCNN on the Kunpeng 920 beside few cases. Furthermore, problem size performance portability experiments with various convolution shapes shows that FastConv achieves 1.2x to 1.7x speedup and 2x to 22x speedup over NNPACK and ARM NN inference engine using Winograd on Kunpeng 920 . CPU performance portability evaluation on the VGG--16 show an average speedup over NNPACK of 1.42x, 1.21x, 1.26x, 1.37x, 2.26x, and 11.02x is observed on Kunpeng 920, Snapdragon 835, 855, 888, Apple M1, and AWS Graviton2, respectively.

97 MATHEMATICS AND COMPUTING↗

A cross-correlation study of the Fermi -LAT γ-ray diffuse extragalactic signal

In this work, starting from 21 months of data from the Fermi Large Area Telescope (LAT), we derive maps of the residual isotropic γ-ray emission, a relevant fraction of which is expected to be contributed by the extragalactic diffuse γ-ray background (EGB). We search for the auto-correlation signals in the above γ-ray maps and for the cross-correlation signal with the angular distribution of different classes of objects that trace the large-scale structure of the Universe. We compute the angular two-point auto-correlation function of the residual Fermi -LAT maps at energies E > 1 GeV, E > 3 GeV and E > 30 GeV well above the Galactic plane and find no significant correlation signal. This is, indeed, what is expected if the EGB were contributed by BL Lacertae (BLLacs), Flat Spectrum Radio Quasars (FSRQs) or star-forming galaxies, since, in this case, the predicted signal is very weak. Then, we search for the Integrated Sachs–Wolfe (ISW) signature by cross-correlating the Fermi-LAT maps with the 7-year Wilkinson Microwave Anisotropy Probe ( WMAP7 ) cosmic microwave background map. We find a cross-correlation consistent with zero, even though the expected signal is larger than that of the EGB auto-correlation. Lastly, in an attempt to constrain the nature of the γ-ray background, we cross-correlate the Fermi -LAT maps with the angular distributions of objects that may contribute to the EGB: quasi-stellar objects (QSOs) in the Sloan Digital Sky Survey Data Release 6 (SDSS-DR6) catalogue, NRAO VLA Sky Survey (NVSS) galaxies, Two Micron All Sky Survey (2MASS) galaxies and Luminous Red Galaxies (LRGs) in the SDSS catalogue. The cross-correlation is always consistent with zero, in agreement with theoretical expectations, but we find (with low statistical significance) some interesting features that may indicate that some specific classes of objects contribute to the EGB. A χ 2 analysis confirms that the correlation properties of the 21-month data do not provide strong constraints of the EGB origin. However, the results suggest that the situation will significantly improve with the 5- and 10-yr Fermi -LAT data. In future, the EGB analysis will then allow placing significant constraints on the nature of the EGB and might provide, in addition, a detection of the ISW signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Temperature and temporal dependence of the optical response for a radiochromic dosimeter

Purpose: Both temporal and thermal dependencies of the dose response have been observed in radiochromic dosimeters. As these dependencies may be influenced by the dose level, the present study investigates the temperature dependence during irradiation and the temporal change of the optical response following irradiation of radiochromic dosimeters at a range of doses. Methods: Cuvette samples of the PRESAGE Trade-Mark-Sign radiochromic dosimeter were irradiated within a dose range of 0-10 Gy at irradiation temperatures within 5-35 Degree-Sign C and postirradiation storage within 6-30 Degree-Sign C. The optical response due to irradiation was measured using a standard spectrophotometer and the data were analyzed in terms of thermal and temporal change. Results: The initial dose response was linear over the applied dose range independent of irradiation temperature. However, the optical response to a specific dose increased exponentially with irradiation temperature corresponding to an activation energy of 0.114 {+-} 0.007 eV. The temporal change in dose response after irradiation consisted of an offset, an auto-oxidation rate with activation energy 0.84 {+-} 0.03 eV, and an initial exponential increase in optical response (1.6 {+-} 0.2 eV) followed by an exponential decrease in optical response (0.98 {+-} 0.08 eV). These contributions depended on both storage temperature and the dose given, leading to a nonlinear dose response with time at low storage temperatures and a high auto-oxidation rate at high storage temperatures. Conclusions: Thermal equilibration is important to the radiochromic dosimeter investigated due to an exponential change in dose response with irradiation temperature and a considerable postirradiation temporal change in response. For the dosimeter version investigated in this study, a compromise in storage temperature has to be made between increasing the nonlinearity of the dose response with time and inducing a high auto-oxidation rate.

36 MATERIALS SCIENCE↗

SU-E-J-224: Multimodality Segmentation of Head and Neck Tumors

Purpose: Develop an algorithm that is able to automatically segment tumor volume in Head and Neck cancer by integrating information from CT, PET and MR imaging simultaneously. Methods: Twenty three patients that were recruited under an adaptive radiotherapy protocol had MR, CT and PET/CT scans within 2 months prior to start of radiotherapy. The patients had unresectable disease and were treated either with chemoradiotherapy or radiation therapy alone. Using the Velocity software, the PET/CT and MR (T1 weighted+contrast) scans were registered to the planning CT using deformable and rigid registration respectively. The PET and MR images were then resampled according to the registration to match the planning CT. The resampled images, together with the planning CT, were fed into a multi-channel segmentation algorithm, which is based on Gaussian mixture models and solved with the expectation-maximization algorithm and Markov random fields. A rectangular region of interest (ROI) was manually placed to identify the tumor area and facilitate the segmentation process. The auto-segmented tumor contours were compared with the gross tumor volume (GTV) manually defined by the physician. The volume difference and Dice similarity coefficient (DSC) between the manual and autosegmented GTV contours were calculated as the quantitative evaluation metrics. Results: The multimodality segmentation algorithm was applied to all 23 patients. The volumes of the auto-segmented GTV ranged from 18.4cc to 32.8cc. The average (range) volume difference between the manual and auto-segmented GTV was −42% (−32.8%–63.8%). The average DSC value was 0.62, ranging from 0.39 to 0.78. Conclusion: An algorithm for the automated definition of tumor volume using multiple imaging modalities simultaneously was successfully developed and implemented for Head and Neck cancer. This development along with more accurate registration algorithms can aid physicians in the efforts to interpret the multitude of imaging information available in radiotherapy today. This project was supported by a grant by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-J-131: Augmenting Atlas-Based Segmentation by Incorporating Image Features Proximal to the Atlas Contours

Purpose: For facilitating the current automatic segmentation, in this work we propose a narrow-shell strategy to enhance the information of each contour in the library and to improve the accuracy of the exiting atlas-based approach. Methods: In setting up an atlas-based library, we include not only the coordinates of contour points, but also the image features adjacent to the contour. 139 planning CT scans with normal appearing livers obtained during their radiotherapy treatment planning were used to construct the library. The CT images within the library were registered each other using affine registration. A nonlinear narrow shell with the regional thickness determined by the distance between two vertices alongside the contour. The narrow shell was automatically constructed both inside and outside of the liver contours. The common image features within narrow shell between a new case and a library case were first selected by a Speed-up Robust Features (SURF) strategy. A deformable registration was then performed using a thin plate splines (TPS) technique. The contour associated with the library case was propagated automatically onto the images of the new patient by exploiting the deformation field vectors. The liver contour was finally obtained by employing level set based energy function within the narrow shell. The performance of the proposed method was evaluated by comparing quantitatively the auto-segmentation results with that delineated by a physician. Results: Application of the technique to 30 liver cases suggested that the technique was capable of reliably segment organs such as the liver with little human intervention. Compared with the manual segmentation results by a physician, the average and discrepancies of the volumetric overlap percentage (VOP) was found to be 92.43%+2.14%. Conclusion: Incorporation of image features into the library contours improves the currently available atlas-based auto-contouring techniques and provides a clinically practical solution for auto-segmentation. This work is supported by NIH/NIBIB (1R01-EB016777), National Natural Science Foundation of China (No.61471226 and No.61201441), Research funding from Shandong Province (No.BS2012DX038 and No.J12LN23), and Research funding from Jinan City (No.201401221 and No.20120109)

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-09: Sensitivity of Plan Re-Optimization to Errors in Deformable Image Registration in Online Adaptive Image-Guided Radiation Therapy

Purpose: Online adaptive therapy (ART) relies on auto-contouring using deformable image registration (DIR). DIR’s inherent uncertainties require user intervention and manual edits while the patient is on the table. We investigated the dosimetric impact of DIR errors on the quality of re-optimized plans, and used the findings to establish regions for focusing manual edits to where DIR errors can Result in clinically relevant dose differences. Methods: Our clinical implementation of online adaptive MR-IGRT involves using DIR to transfer contours from CT to daily MR, followed by a physicians’ edits. The plan is then re-optimized to meet the organs at risk (OARs) constraints. Re-optimized abdomen and pelvis plans generated based on physician edited OARs were selected as the baseline for evaluation. Plans were then re-optimized on auto-deformed contours with manual edits limited to pre-defined uniform rings (0 to 5cm) around the PTV. A 0cm ring indicates that the auto-deformed OARs were used without editing. The magnitude of the variations caused by the non-deterministic optimizer was quantified by repeat re-optimizations on the same geometry to determine the mean and standard deviation (STD). For each re-optimized plan, various volumetric parameters for the PTV, the OARs were extracted along with DVH and isodose evaluation. A plan was deemed acceptable if the variation from the baseline plan was within one STD. Results: Initial results show that for abdomen and pancreas cases, a minimum of 5cm margin around the PTV is required for contour corrections, while for pelvic and liver cases a 2–3 cm margin is sufficient. Conclusion: Focusing manual contour edits to regions of dosimetric relevance can reduce contouring time in the online ART process while maintaining a clinically comparable plan. Future work will further refine the contouring region by evaluating the path along the beams, dose gradients near the target and OAR dose metrics.

60 APPLIED LIFE SCIENCES↗

SU-C-BRA-05: Delineating High-Dose Clinical Target Volumes for Head and Neck Tumors Using Machine Learning Algorithms

Purpose: To develop and test population-based machine learning algorithms for delineating high-dose clinical target volumes (CTVs) in H&N tumors. Automating and standardizing the contouring of CTVs can reduce both physician contouring time and inter-physician variability, which is one of the largest sources of uncertainty in H&N radiotherapy. Methods: Twenty-five node-negative patients treated with definitive radiotherapy were selected (6 right base of tongue, 11 left and 9 right tonsil). All patients had GTV and CTVs manually contoured by an experienced radiation oncologist prior to treatment. This contouring process, which is driven by anatomical, pathological, and patient specific information, typically results in non-uniform margin expansions about the GTV. Therefore, we tested two methods to delineate high-dose CTV given a manually-contoured GTV: (1) regression-support vector machines(SVM) and (2) classification-SVM. These models were trained and tested on each patient group using leave-one-out cross-validation. The volume difference(VD) and Dice similarity coefficient(DSC) between the manual and auto-contoured CTV were calculated to evaluate the results. Distances from GTV-to-CTV were computed about each patient’s GTV and these distances, in addition to distances from GTV to surrounding anatomy in the expansion direction, were utilized in the regression-SVM method. The classification-SVM method used categorical voxel-information (GTV, selected anatomical structures, else) from a 3×3×3cm3 ROI centered about the voxel to classify voxels as CTV. Results: Volumes for the auto-contoured CTVs ranged from 17.1 to 149.1cc and 17.4 to 151.9cc; the average(range) VD between manual and auto-contoured CTV were 0.93 (0.48–1.59) and 1.16(0.48–1.97); while average(range) DSC values were 0.75(0.59–0.88) and 0.74(0.59–0.81) for the regression-SVM and classification-SVM methods, respectively. Conclusion: We developed two novel machine learning methods to delineate high-dose CTV for H&N patients. Both methods showed promising results that hint to a solution to the standardization of the contouring process of clinical target volumes. Varian Medical Systems grant.

60 APPLIED LIFE SCIENCES↗

SU-C-BRA-06: Automatic Brain Tumor Segmentation for Stereotactic Radiosurgery Applications

Purpose: Stereotactic radiosurgery (SRS), which delivers a potent dose of highly conformal radiation to the target in a single fraction, requires accurate tumor delineation for treatment planning. We present an automatic segmentation strategy, that synergizes intensity histogram thresholding, super-voxel clustering, and level-set based contour evolving methods to efficiently and accurately delineate SRS brain tumors on contrast-enhance T1-weighted (T1c) Magnetic Resonance Images (MRI). Methods: The developed auto-segmentation strategy consists of three major steps. Firstly, tumor sites are localized through 2D slice intensity histogram scanning. Then, super voxels are obtained through clustering the corresponding voxels in 3D with reference to the similarity metrics composited from spatial distance and intensity difference. The combination of the above two could generate the initial contour surface. Finally, a localized region active contour model is utilized to evolve the surface to achieve the accurate delineation of the tumors. The developed method was evaluated on numerical phantom data, synthetic BRATS (Multimodal Brain Tumor Image Segmentation challenge) data, and clinical patients’ data. The auto-segmentation results were quantitatively evaluated by comparing to ground truths with both volume and surface similarity metrics. Results: DICE coefficient (DC) was performed as a quantitative metric to evaluate the auto-segmentation in the numerical phantom with 8 tumors. DCs are 0.999±0.001 without noise, 0.969±0.065 with Rician noise and 0.976±0.038 with Gaussian noise. DC, NMI (Normalized Mutual Information), SSIM (Structural Similarity) and Hausdorff distance (HD) were calculated as the metrics for the BRATS and patients’ data. Assessment of BRATS data across 25 tumor segmentation yield DC 0.886±0.078, NMI 0.817±0.108, SSIM 0.997±0.002, and HD 6.483±4.079mm. Evaluation on 8 patients with total 14 tumor sites yield DC 0.872±0.070, NMI 0.824±0.078, SSIM 0.999±0.001, and HD 5.926±6.141mm. Conclusion: The developed automatic segmentation strategy, which yields accurate brain tumor delineation in evaluation cases, is promising for its application in SRS treatment planning.

60 APPLIED LIFE SCIENCES↗