Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

New development of advanced superconducting electron cyclotron resonance ion source SECRAL (invited)

Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18-28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e {mu}A of {sup 129}Xe{sup 43+}, 22 e {mu}A of {sup 209}Bi{sup 41+}, and 1.5 e {mu}A of {sup 209}Bi{sup 50+}. To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e {mu}A of {sup 129}Xe{sup 27+} and 152 e {mu}A of {sup 129}Xe{sup 30+}, although the commissioning time was limited within 3-4 weeks and rf power only 3-4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and {sup 129}Xe{sup 27+}, {sup 78}Kr{sup 19+}, {sup 209}Bi{sup 31+}, and {sup 58}Ni{sup 19+} beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of ECR ion source for highly charged heavy ion beam production. Finally the future development of SECRAL will be presented.

43 PARTICLE ACCELERATORS↗

Investigations of the emittance and brightness of ion beams from an electron beam ion source of the Dresden EBIS type

We have characterized ion beams extracted from the Dresden EBIS-A, a compact room-temperature electron beam ion source (EBIS) with a permanent magnet system for electron beam compression, using a pepper-pot emittance meter. The EBIS-A is the precursor to the Dresden EBIS-SC in which the permanent magnets have been replaced by superconducting solenoids for the use of the source in high-ion-current applications such as heavy-ion cancer therapy. Beam emittance and brightness values were calculated from data sets acquired for a variety of source parameters, in leaky as well as pulsed ion extraction mode. With box shaped pulses of C{sup 4+} ions at an energy of 39 keV root mean square emittances of 1-4 mm mrad and a brightness of 10 nA mm{sup -2} mrad{sup -2} were achieved. The results meet the expectations for high quality ion beams generated by an electron beam ion source.

43 PARTICLE ACCELERATORS↗

High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

43 PARTICLE ACCELERATORS↗

Gallium ion extraction from a plasma sputter-type ion source

A broad mixed ion beam containing positive ions of gallium (Ga) was produced with a plasma sputter-type ion source. Liquid Ga was suspended on a tungsten reservoir to be sputtered and postionized in argon (Ar) plasma excited by a radio frequency (rf) power at 13.56 MHz. Optical emission spectra from the plasma near the Ga sputtering target had indicated that the release of Ga into plasma increased with increasing negative bias to the sputtering target. The ratio of Ga{sup +} current to Ar{sup +} current was measured to be about 1% with a quadrupole mass analyzer at 100 V extraction voltage for incident rf power as low as 30 W. Ions in the plasma were extracted through a pair of multiaperture electrodes. The homogeneity of Ga flux was examined by making a Ga deposition pattern on a glass substrate located behind the extractor electrodes.

43 PARTICLE ACCELERATORS↗

Response-time improved hydrothermal-method-grown ZnO scintillator for soft x-ray free-electron laser timing-observation

For pump and probe experiments in x-ray free-electron laser (XFEL) facilities, accurate timing synchronization between short-wavelength femtosecond pulses from XFELs and short optical pulses from other light sources is required. For this purpose, the response time of a hydrothermal-method-grown ZnO is improved by over one order of magnitude via intentional iron ion doping. The fluorescence rise- and decay-time constants are measured to be less than 10 and 100 ps, respectively. Owing to its intense fluorescence even for single pulse XFEL excitation, the timing jitter of the soft x-ray pulse and timing electronics are evaluated to be less than 70 ps.

43 PARTICLE ACCELERATORS↗

High Power Operation of the THz FEL at ISIR, Osaka University

The free-electron laser based on the L-band electron linac is under development to generate high power radiation in the THz region. Recent results of the development are presented, including the wavelength spectra and the output power vs. wavelength from 25 to 110 {mu}m.

43 PARTICLE ACCELERATORS↗

Performance of the AILES THz-Infrared beamline at SOLEIL for High resolution spectroscopy

The new THz beamline (AILES) located at the third generation Synchrotron Radiation source SOLEIL is now operating for applications in a wide variety of research themes. In particular, this source with its adapted optics allows high resolution spectroscopic measurements of molecules in the entire infrared and THz range. This presentation focuses on the performances concerning flux, spectral range and stability for molecular spectroscopy. Thanks to these performances, the coupling of synchrotron radiation from a highly stable third generation source with high resolution FTIR spectrometer and with a long path cell (150 m or more) can be particularly advantageous. This fact is related to the optics of the beamline permitting the entire source to be used without aperture stop (entrance iris), even for measurements at highest-resolution of approx0.1 mueV (10{sup -3} cm{sup -1}).

43 PARTICLE ACCELERATORS↗

Development of a multipurpose vacuum chamber for serial optical and diffraction experiments with free electron laser radiation

In this paper we present a development of a multipurpose vacuum chamber which primal function is to be used in pump/probe experiments with free electron laser (FEL) radiation. The chamber is constructed for serial diffraction and serial spectroscopy allowing a fast exchange of samples during the measurement process. For the fast exchange of samples, liquid jet systems are used. Both applications, utilizing soft x-ray FEL pulses as pump and optical laser pulses as probe and vice versa are documented. Experiments with solid samples as well as the liquid jet samples are presented. When working with liquid jets, a system of automatically refilled liquid traps for capturing liquids has been developed in order to ensure stable vacuum conditions. Differential pumping stages are placed in between the FEL beamline and the experimental chamber so that working pressure in the chamber can be up to four orders of magnitude higher than the pressure in the FEL beamline.

43 PARTICLE ACCELERATORS↗

Elementary Ion Optics with Applications to Electromagnetic Spectrometers

This lecture, intended for physics graduate students, represents an introduction to ion optics with applications to the electromagnetic spectrometers used in nuclear astrophysics research. A particular radiative capture reaction is chosen to illustrate the requirements of such spectrometers.

43 PARTICLE ACCELERATORS↗

Absolute calibration of LIDAR Thomson scattering systems by rotational Raman scattering

Absolute calibration of LIDAR Thomson scattering systems on large fusion devices may be achieved using rotational Raman scattering. The choice of calibrating gas molecule presents different options and design trade-offs and is likely to be strongly dependent on the laser wavelength selected. Raman scattering of hydrogenic molecules produces a very broad spectrum, however, with far fewer scattered photons than scattering from nitrogen or oxygen at the same gas pressure. Lower laser wavelengths have the advantage that the Raman cross section increases, {sigma}{sub Raman}{proportional_to}1/{lambda}{sub 0}{sup 4}, but the disadvantage that the spectral width of the scattered spectrum decreases, {Delta}{lambda}{sub Raman}{proportional_to}{lambda}{sub 0}{sup 2}. This narrower spectrum makes measurement closer to the laser wavelength necessary. The design of the calibration technique presents a number of challenges. Some of these challenges are generic to all Thomson scattering systems. These include detecting a sufficient number of photoelectrons and designing filters that measure close to the laser wavelength while simultaneously achieving adequate blocking of the laser wavelength. An issue specific to LIDAR systems arises since the collection optics operates over a wide range of depth of field. This wide depth of field has the effect of changing the angle of light incident on the optical interference filter with plasma major radius. The angular distribution then determines the effective spectral transmission function of the interference filter and hence impacts on the accuracy of the absolute calibration. One method that can be used to increase absolute calibration accuracy is collecting both Stokes and anti-Stokes lines with optical filter transmission bands specifically designed to reduce systematic uncertainty.

43 PARTICLE ACCELERATORS↗

The extreme ultraviolet split and femtosecond delay unit at the plane grating monochromator beamline PG2 at FLASH

An extreme ultraviolet split and femtosecond delay unit based on grazing incidence Mach-Zehnder geometry has been designed and implemented on the plane grating monochromator beamline PG2 at FLASH, the Free Electron Laser at DESY. This device splits the FLASH radiation into two beams, which can independently be steered, filtered and temporally delayed between -5.1 and +5.1 ps with uncertainty in the temporal accuracy of 210 as. To demonstrate the performance of this device, we have performed longitudinal coherence studies of FLASH radiation as well as measured the pulse length by nonlinear two-photon double-ionization in helium.

43 PARTICLE ACCELERATORS↗

Experimental verification of tomographic phase-space imaging for beams with space-charge using a pinhole-scan

A model is described for tomographic phase-space mapping and emittance measurement in beams with space-charge. The tomographic results of an experiment with a 10 keV space-charge dominated electron beam are presented. The data are compared against a direct experimental sampling of the phase-space using a pinhole scan. It is found that the accuracy of the tomographic method is within 10% for beams with space-charge intensity less than 90%. With the aid of numerical simulation the observed similarities and differences between the tomography method and pinhole scan are discussed.

43 PARTICLE ACCELERATORS↗

The MANX Muon Cooling Experiment Detection System

The MANX experiment is being proposed to demonstrate the reduction of 6D muon phase space emittance, using a continuous liquid absorber to provide ionization cooling in a helical solenoid magnetic channel. The experiment involves the construction of a two-period-long helical cooling channel (HCC) to reduce the muon invariant emittance by a factor of two. The HCC would replace the current cooling section of the MICE experiment now being set up at the Rutherford Appleton Laboratory. The MANX experiment would use the existing MICE spectrometers and muon beam line. We discuss the placement of detection planes to optimize the muon track resolution.

43 PARTICLE ACCELERATORS↗

Status of the International Design Study of the Neutrino Factory

The International Design Study for the Neutrino Factory (the IDS-NF) has been established by the Neutrino Factory community to deliver the Reference Design Report (RDR) for the facility by 2012. The baseline design for the facility, developed from that defined in the International Scoping Study of a future Neutrino Factory and super-beam facility (the ISS), will provide 10{sup 21} muon decays per year from 25 GeV stored muon beams. The facility will serve two neutrino detectors; one situated at source-detector distance of between 3000-5000 km, the second at 7000-8000 km. The baseline design for the facility will be described and the status of the IDS-NF effort will be summarised.

43 PARTICLE ACCELERATORS↗

Abel transform analysis of ion storage ring imaging data

In this paper a new approach to analyze dissociative recombination product distance distributions measured at ion storage rings is presented. This approach is based on an Abel transform and the validity is demonstrated for the imaging data obtained from the CRYRING experiments on the dissociative recombination of H{sub 2}{sup +} and CO{sup +}. The reported method is generally valid for the data analysis of high resolution merged beams experiments such as DESIREE where isotropic fragment distributions can be expected.

43 PARTICLE ACCELERATORS↗

SAMRAI: A novel variably polarized angle-resolved photoemission beamline in the VUV region at UVSOR-II

A novel variably polarized angle-resolved photoemission spectroscopy beamline in the vacuum-ultraviolet (VUV) region has been installed at the UVSOR-II 750 MeV synchrotron light source. The beamline is equipped with a 3 m long APPLE-II type undulator with horizontally/vertically linear and right/left circular polarizations, a 10 m Wadsworth type monochromator covering a photon energy range of 6-43 eV, and a 200 mm radius hemispherical photoelectron analyzer with an electron lens of a {+-}18 deg. acceptance angle. Due to the low emittance of the UVSOR-II storage ring, the light source is regarded as an entrance slit, and the undulator light is directly led to a grating by two plane mirrors in the monochromator while maintaining a balance between high-energy resolution and high photon flux. The energy resolving power (h{nu}/{Delta}h{nu}) and photon flux of the monochromator are typically 1x10{sup 4} and 10{sup 12} photons/s, respectively, with a 100 {mu}m exit slit. The beamline is used for angle-resolved photoemission spectroscopy with an energy resolution of a few meV covering the UV-to-VUV energy range.

43 PARTICLE ACCELERATORS↗

Nanoradian angular stabilization of x-ray optical components

An x-ray free-electron laser oscillator (XFELO) has been recently proposed [K. Kim et al., Phys. Rev. Lett. 100, 244802 (2008)]. Angular orientation and position in space of Bragg mirrors of the XFELO optical cavity must be continuously adjusted to compensate for the instabilities and maximize the output intensity. An angular stability of about 10 nrad (rms) is required [K. Kim and Y. Shvyd'ko, Phys. Rev. ST Accel. Beams 12, 030703 (2009)]. To approach this goal, a feedback loop based on a null-detection principle was designed and used for stabilization of a high-energy-resolution x-ray monochromator ({Delta}E/E{approx_equal}4x10{sup -8}, E=23.7 keV) and a high-heat-load monochromator. Angular stability of about 13 nrad (rms) has been demonstrated for x-ray optical elements of the monochromators.

43 PARTICLE ACCELERATORS↗

A compact, sample-in-atmospheric-pressure soft x-ray microscope developed at Pohang Light Source

A full-field transmission soft x-ray microscope (TXM) was developed at the Pohang Light Source. With a 2 mm diameter condenser zone plate and a 40 nm outermost-zone-width objective zone plate, the TXM's achieved spatial resolution is better than 50 nm at the photon energy of 500 eV (wavelength: 2.49 nm). The TXM is portable and mounted in tandem with a 7B1 spectroscopy end station. The sample position is outside the vacuum, allowing for quick sample changes and enhanced in situ experimental capability. In addition, the TXM is pinhole-free and easy to align, having commercial mounts located outside the vacuum components.

43 PARTICLE ACCELERATORS↗