Comparison of Partial-Pressure Analyzers
Comparison of three partial-pressure gas analyzers used in ultrahigh vacuum range
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Comparison of three partial-pressure gas analyzers used in ultrahigh vacuum range
Criteria for selecting residual gas analyzers using mass spectrometer principle
Low-power multichannel pulse height analyzer for solar neutron detection aboard balloon or rocket
Random access memory core for space-borne pulse height analyzer
Switched amplifier, mode control circuit for ASTRAC II iterative differential analyzer
Miniaturizing automatic amino acid analyzer for Apollo and Voyager missions
Miniaturizing n automatic amino acid analyzer for use on Apollo mission and Mars Voyager mission
Digital to analog pulser system for integral and differential testing pulse height analyzers
The Science Opportunity Analyzer, SOA, now in its third year of development, is intended to meet the need of adaptability to the various mission types at JPL and portability for the user community.
In the past Science Planning for space missions has been comprised of using ad-hoc software toolscollected or reconstructed from previous missions, tools used by other groups who often speak a different 'technical' language or even 'the backs of envelopes'. In addition to the tools being rough, the work done with these tools often has had to be redone or at least re-entered when it came time to determine actual observations. Science Opportunity Analyzer (SOA), a Java-based application, has been built for scientists to enable them to identify/analyze observation opportunities and then, to create corresponding observation designs.
The design, fabrication techniques and first test results of a new type of micromachined energy analyzer for charged particles are presented.
We report our findings comparing the geometric factor (GF) as determined from simulations and laboratory measurements of the new Dual Electron Spectrometer (DES) being developed at NASA Goddard Space Flight Center as part of the Fast Plasma Investigation on NASA's Magnetospheric Multiscale mission. Particle simulations are increasingly playing an essential role in the design and calibration of electrostatic analyzers, facilitating the identification and mitigation of the many sources of systematic error present in laboratory calibration. While equations for laboratory measurement of the Geometric Factpr (GF) have been described in the literature, these are not directly applicable to simulation since the two are carried out under substantially different assumptions and conditions, making direct comparison very challenging. Starting from first principles, we derive generalized expressions for the determination of the GF in simulation and laboratory, and discuss how we have estimated errors in both cases. Finally, we apply these equations to the new DES instrument and show that the results agree within errors. Thus we show that the techniques presented here will produce consistent results between laboratory and simulation, and present the first description of the performance of the new DES instrument in the literature.
NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated. Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU /flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.
A stability analyzer is described, for testing of NASA Deep Space Network installations during
The ocean's coastal zones play a key role in our planet's health and mitigate the adverse effects of climate change. Building on the success of NASA satellite imagery in mapping land cover changes around the globe in response to climate change, deforestation, and natural disasters, I have worked to determine how aquatic reflectance images from the Landsat 8 sensor could be correlated with biogeochemical constituents within the waters of the San Francisco Bay Area and California coastline. By analyzing Landsat 8 satellite imagery from the years 2013-2020 in collaboration with data from the United States Geological Survey (USGS), San Francisco Estuary Institute (SFEI), and universities involved with the Harmful Algal Bloom Monitoring and Alert Program (HABMAP), I investigated which areas of the San Francisco Bay and California coastline demonstrated significant correlations with values extracted from the satellite imagery. Using a Chlorophyll Index (CI) ratio calculated from two Landsat 8 satellite reflectance bands, it was found that there is a positive correlation between the CI and calculated oxygen, suspended particulate matter, and silicate from several USGS sampling points. In contrast, there is a significant negative correlation between the CI and salinity, nitrite, and phosphate at those same locations. Moreover, large suspected harmful algal blooms (HABs) along the California coastline seen in the Landsat 8 imagery were corroborated with HAB data from various institutions. Understanding the effectiveness of Landsat 8 aquatic reflectance images will allow scientists to predict HABs and other nutrient cycling that may be harmful to aquatic ecosystems around the world.
Radiation detection technology is invaluable to many fields of study in identifying nuclear materials. However, many detectors use gross-counting methods that give only a relative count rate. Without a spectrum (information on counts over time vs energy), it can be more difficult to discern if an alarm is false, innocent, or real. In particular, we would like to understand better the effect of experimental factors (i.e., external conditions and equipment parameters) on detector data, with possible implications for false alarms. To more thoroughly characterize detector technology, a multichannel analyzer (MCA) was used to record spectra from neutron (helium-3 tubes) and gamma (photomultiplier tubes) gross-counting detectors. Several factors could affect the signal-to-noise ratio of sources. For example, we examined the effects of neutron detector high voltage setting on the appearance of a californium-252 spectrum, the effect of discriminator values on integrated counts in neutron detection, and the effect of gain changes on the gamma spectra from several sources. Possible implications of ambient temperature of the experiment on the data collected will be discussed. The input impedance of the MCA must be considered to ensure that data are not affected by the measurement itself. Moreover, a calibration on the MCA was performed to verify the conversion of a MCA channel number to a voltage. In summary, the series of source spectra collected on an MCA with a variety of experimental conditions allow us to understand factors that affect data better, and assure us that gross-counting neutron and gamma detectors will have minimal false alarms.
Fabrication of the first series of fuel compacts for the current US tristructural isotropic (TRISO) coated particle fuel development and qualification effort was completed at Oak Ridge National Laboratory (ORNL) in 2006. In November of 2009, after almost 3 years and 620 effective full power days of irradiation in the Advanced Test Reactor at Idaho National Laboratory (INL), the first Advanced Gas Reactor irradiation test (AGR-1) was concluded. Compacts were irradiated at a calculated timeaveraged, volume-averaged temperature of 955–1136°C to a burnup ranging from 11.2–19.5% fissions per initial metal atom and a total fast fluence of 2.2–4.3·1025 n/m2 [1]. No indication of fission product release from TRISO coating failure was observed during the irradiation test, based on real-time monitoring of gaseous fission products. Post-irradiation examination (PIE) and hightemperature safety testing of the compacts has been in progress at both ORNL and INL since 2010, and have revealed small releases of a limited subset of fission products (such as silver, cesium, and europium). Past experience has shown that some elements can be released from TRISO particles when a defect forms in the SiC layer, even when one or more pyrocarbon layers remain intact and retain the gaseous fission products. Some volatile elements can also be released by diffusion through an intact SiC layer during safety testing if temperatures are high enough and the duration is long enough. In order to understand and quantify the release of certain radioactive fission products, it is sometimes necessary to individually examine each of the more than 4000 coated particles in a given compact. The Advanced Irradiated Microsphere Gamma Analyzer (Advanced- IMGA) was designed to perform this task in a remote hot cell environment. This paper describes the Advanced- IMGA equipment and examination process and gives results for a typical full compact evaluation.