Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Polar-direct-drive experiments on the National Ignition Facility

To support direct-drive inertial confinement fusion experiments at the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 43, 2841 (2004)] in its indirect-drive beam configuration, the polar-direct-drive (PDD) concept [S. Skupsky et al., Phys. Plasmas 11, 2763 (2004)] has been proposed. Ignition in PDD geometry requires direct-drive–specific beam smoothing, phase plates, and repointing the NIF beams toward the equator to ensure symmetric target irradiation. First experiments to study the energetics and preheat in PDD implosions at the NIF have been performed. These experiments utilize the NIF in its current configuration, including beam geometry, phase plates, and beam smoothing. Room-temperature, 2.2-mm-diam plastic shells filled with D{sub 2} gas were imploded with total drive energies ranging from ∼500 to 750 kJ with peak powers of 120 to 180 TW and peak on-target irradiances at the initial target radius from 8 × 10{sup 14} to 1.2 × 10{sup 15 }W/cm{sup 2}. Results from these initial experiments are presented, including measurements of shell trajectory, implosion symmetry, and the level of hot-electron preheat in plastic and Si ablators. Experiments are simulated with the 2-D hydrodynamics code DRACO including a full 3-D ray-trace to model oblique beams, and models for nonlocal electron transport and cross-beam energy transport (CBET). These simulations indicate that CBET affects the shell symmetry and leads to a loss of energy imparted onto the shell, consistent with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A treatment planning study to assess the feasibility of laser-driven proton therapy using a compact gantry design

Purpose: Laser-driven proton acceleration is suggested as a cost- and space-efficient alternative for future radiation therapy centers, although the properties of these beams are fairly different compared to conventionally accelerated proton beams. The laser-driven proton beam is extremely pulsed containing a very high proton number within ultrashort bunches at low bunch repetition rates of few Hz and the energy spectrum of the protons per bunch is very broad. Moreover, these laser accelerated bunches are subject to shot-to-shot fluctuations. Therefore, the aim of this study was to investigate the feasibility of a compact gantry design for laser-driven proton therapy and to determine limitations to comply with. Methods: Based on a published gantry beam line design which can filter parabolic spectra from an exponentially decaying broad initial spectrum, a treatment planning study was performed on real patient data sets. All potential parabolic spectra were fed into a treatment planning system and numerous spot scanning proton plans were calculated. To investigate limitations in the fluence per bunch, the proton number of the initial spectrum and the beam width at patient entrance were varied. A scenario where only integer shots are delivered as well as an intensity modulation from shot to shot was studied. The resulting plans were evaluated depending on their dosimetric quality and in terms of required treatment time. In addition, the influence of random shot-to-shot fluctuations on the plan quality was analyzed. Results: The study showed that clinically relevant dose distributions can be produced with the system under investigation even with integer shots. For small target volumes receiving high doses per fraction, the initial proton number per bunch must remain between 1.4 × 10{sup 8} and 8.3 × 10{sup 9} to achieve acceptable delivery times as well as plan qualities. For larger target volumes and standard doses per fraction, the initial proton number is even more restricted to stay between 1.4 × 10{sup 9} and 2.9 × 10{sup 9}. The lowest delivery time that could be reached for such a case was 16 min for a 10 Hz system. When modulating the intensity from shot to shot, the delivery time can be reduced to 6 min for this scenario. Since the shot-to-shot fluctuations are of random nature, a compensation effect can be observed, especially for higher laser shot numbers. Therefore, a fluctuation of ±30% within the proton number does not translate into a dosimetric deviation of the same size. However, for plans with short delivery times these fluctuations cannot cancel out sufficiently, even for ±10% fluctuations. Conclusions: Under the analyzed terms, it is feasible to achieve clinically relevant dose distributions with laser-driven proton beams. However, to keep the delivery times of the proton plans comparable to conventional proton plans for typical target volumes, a device is required which can modulate the bunch intensity from shot to shot. From the laser acceleration point of view, the proton number per bunch must be kept under control as well as the reproducibility of the bunches.

60 APPLIED LIFE SCIENCES↗

Spatial Filtering of a Diode Laser Beam for Confocal Raman Microscopy

With the development of single-longitudinal mode diode lasers, there has been an increase in using these sources for Raman spectroscopy. This is largely due to the cost-effectiveness of diode lasers, which offer savings not only in initial capital cost, but also electrical, cooling, and replacement costs over time, when compared with ion lasers. Here, the use of diode-lasers in confocal Raman microscopy has remained a challenge, however, due to poor transverse beam quality. In this work, we present the design and implementation of a simple spatial filter capable of adapting a single-mode diode laser source to confocal Raman microscopy, yielding comparable spatial resolution as a gas-ion laser beam for profiling and optical-trapping applications. For profiling applications, spatial filtering improved x,y resolution of the beam by a factor 10, which in turn increased optical-trapping forces by ~90 times and yielded sevenfold greater Raman scattering signal intensity from an optically trapped phospholipid vesicle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Refined interpretation of electron temperature response to neutral beam injection at DIII-D

Accurate particle and power deposition profiles of neutral beam injection (NBI) are essential to transport studies, and that information is usually acquired through Monte Carlo simulations with a given collisional model. The deposition process of the energetic beam particles leads to the informative electron temperature (T e ) evolution trajectory, which can be captured by electron cyclotron emission (ECE) system due to its good spatial and temporal resolution. Previously, some work has been done to interpret the T e responses to the pulsed NBI as a linear heating source with Fourier-based techniques, although that approach fell short when the fast ion slowing-down time becomes significant (~100 ms). It has been observed in DIII-D that the modulated NBI pulses (10–50 Hz) reduce local core T e values ~0.1 keV through cold electron dilution in high-T e (>2 keV) plasmas alongside accumulative heating. Here, a novel approach to interpret the T e response to NBI was developed by linearizing and modeling the detailed T e evolution trajectory using coherently averaged ECE data based on the different time scales of the terms in the local power and particle balance equations. The technique does not require absolute calibrations of ECE and is independent of collisional models. The resulting beam deposition profiles show good consistency and reasonable agreement with Monte Carlo calculations based on the atomic data from the Atomic Data and Analysis Structure (ADAS). Local electron density response measured by Thomson scattering (TS) also suggests the same features when the beam pulse is large enough for that diagnostic to resolve. The remaining discrepancies are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards a wavefront-preservation X-ray crystal monochromator for high-repetition-rate FELs

The wavefront preservation of coherent X-ray free-electron laser beams is pushing the requirement on the quality and performance of X-ray optics to an unprecedented level. The Strehl ratio can be used to quantify this requirement. In this paper, the criteria for thermal deformation of the X-ray optics are formulated, especially for crystal monochromators. To preserve the X-ray wavefront, the standard deviation of the height error should be sub-nm for mirrors and less than 25 pm for crystal monochromators. Cryocooled silicon crystals combined with two techniques can be used to achieve this level of performance for monochromator crystals: (1) using a focusing element to compensate the second-order component of the thermal deformation; (2) introducing a cooling pad between the cooling block and silicon crystal and optimizing the effective cooling temperature. Each of these techniques allows the thermal deformation in standard deviation of the height error to be reduced by an order of magnitude. As an example, for the LCLS-II-HE Dynamic X-ray Scattering instrument, the criteria on thermal deformation of a high-heat-load monochromator crystal can be achieved for a 100 W SASE FEL beam. Wavefront propagation simulations confirm that the reflected beam intensity profile is satisfactory on both the peak power density and focused beam size.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Anomalous material-dependent transport of focused, laser-driven proton beams

Intense lasers can accelerate protons in sufficient numbers and energy that the resulting beam can heat materials to exotic warm (10s of eV temperature) states. Here we show with experimental data that a laser-driven proton beam focused onto a target heated it in a localized spot with size strongly dependent upon material and as small as 35 mm radius. Simulations indicate that cold stopping power values cannot model the intense proton beam transport in solid targets well enough to match the large differences observed. In the experiment a 74 J, 670 f s laser drove a focusing proton beam that transported through different thicknesses of solid Mylar, Al, Cu or Au, eventually heating a rear, thin, Au witness layer. The XUV emission seen from the rear of the Au indicated a clear dependence of proton beam transport upon atomic number, Z, of the transport layer: a larger and brighter emission spot was measured after proton transport through the lower Z foils even with equal mass density for supposed equivalent proton stopping range. Beam transport dynamics pertaining to the observed heated spot were investigated numerically with a particle-in-cell (PIC) code. In simulations protons moving through an Al transport layer result in higher Au temperature responsible for higher Au radiant emittance compared to a Cu transport case. As a result, the inferred finding that proton stopping varies with temperature in different materials, considerably changing the beam heating profile, can guide applications seeking to controllably heat targets with intense proton beams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Controlling hollow relativistic electron beam orbits with an inductive current divider

A passive method for controlling the trajectory of an intense, hollow electron beam is proposed using a vacuum structure that inductively splits the beam's return current. A central post carries a portion of the return current (I{sub 1}), while the outer conductor carries the remainder (I{sub 2}). An envelope equation appropriate for a hollow electron beam is derived and applied to the current divider. The force on the beam trajectory is shown to be proportional to (I{sub 2}-I{sub 1}), while the average force on the envelope (the beam width) is proportional to the beam current I{sub b} = (I{sub 2} + I{sub 1}). The values of I{sub 1} and I{sub 2} depend on the inductances in the return-current path geometries. Proper choice of the return-current geometries determines these inductances and offers control over the beam trajectory. Solutions using realistic beam parameters show that, for appropriate choices of the return-current-path geometry, the inductive current divider can produce a beam that is both pinched and straightened so that it approaches a target at near-normal incidence with a beam diameter that is on the order of a few mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

`Pink'-beam X-ray powder diffraction profile and its use in Rietveld refinement

The powder diffraction profile obtained with a pink-beam synchrotron X-ray source is described as the convolution of a back-to-back pair of exponentials convoluted with the Gaussian and Lorentzian components of a pseudo-Voigt. We report this new function is employed for the first time in a Rietveld refinement using data collected from a single 100 ps synchrotron X-ray micropulse.

36 MATERIALS SCIENCE↗

Electron beam injection from a hollow cathode plasma into a downstream reactive environment: Characterization of secondary plasma production and Si 3 N 4 and Si etching

A material etching system was developed by combining beam electron injection from a direct current (DC) hollow-cathode (HC) electron source with the downstream reactive environment of a remote CF 4 /O 2 low temperature plasma. The energy of the injected beam electrons is controlled using an acceleration electrode biased positively relative to the HC Argon discharge. For an acceleration voltage greater than the ionization potential of Ar, the extracted primary electrons can produce a secondary plasma in the process chamber. We characterized the properties of the secondary plasma by performing Langmuir probe measurements of the electron energy probability function (EEPF) 2.5 cm below the extraction ring. The data indicate the existence of two major groups of electrons, including electrons with a primary beam electron energy which varies as the acceleration voltage is varied, along with low energy electrons produced by ionization of the Ar gas atoms in the process chamber by the injected beam electrons. When combining the HC Ar beam electron with a remote CF 4 /O 2 electron cyclotron wave resonance (ECWR) plasma, the EEPF of both the low energy plasma electron and beam electron components decreases. Additionally, we studied surface etching of Si3N4 and poly-crystalline Si (poly-Si) thin films as a function of process parameters, including the acceleration voltage (0-70 V), discharge current of the HC discharge (1-2 A), pressure (2- 100 mTorr), source to substrate distance (2.5 to 5 cm), and feed gas composition (with or without CF 4 /O 2 ). The direction of the incident beam electrons was perpendicular to the surface. Si 3 N 4 and poly-crystalline silicon etching are seen and indicate an electronneutral synergy effect. No/little remote plasma spontaneous etching was observed for the conditions used in this study, and the etching is confined to the substrate area irradiated by the injected beam electrons. The electron etched Si 3 N 4 surface etching rate profile distribution is confined within a ~30 mm diameter circle, which is slightly broader than the area for which poly-Si etching is seen, and coincides closely with the spatial profile of beam electrons as determined by the Langmuir probe measurements. The magnitude of poly-Si etching rate is by a factor of two times smaller than the Si 3 N 4 etching rate. In this paper, we discuss possible explanations of the data and the role of surface charging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the density profile of pure and seeded molecular beams by femtosecond ion imaging

Here, we report on femtosecond ion imaging experiments to measure the density profile of a pulsed supersonic molecular beam. Ion images are measured for both a molecular beam and bulk gas under identical experimental conditions via femtosecond multiphoton ionization of Xe atoms. We report the density profile of the molecular beam, and the measured absolute density is compared with theoretical calculations of the centre line beam density. Subsequently, we discuss reasons accounting for the differences between measurements and calculations and propose that strong skimmer interference is the most probable cause for the differences. Furthermore, we report on experiments measuring the centre line density of seeded supersonic beams. The femtosecond ion images show that seeding the heavy Xe atom at low relative seed fractions (1%-10%) in a light carrier gas like Ne results in strong relative enhancements of up to two orders of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of Ionization Profile Monitors at the Integrable Optics Test Accelerator Facility at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab is transitioning from an electron beam facility to a proton beam facility for studies in nonlinear accelerator optics and space-charge dominated proton beams. This project involves the commissioning and fabrication of Ionization Profile Monitors (IPMs) to enable beam profile measurements at IOTA. In general, IPMs work on principle of residual gas ionization by the beam to generate beam profile. This work focuses on a mechanical design that leverages a controlled injection of noble gases, primarily Argon, as the ultra-high vacuum of the IOTA ring provides insufficient residual gas for ionization. Efforts to understand vacuum integration to ensure compatibility with the storage ring environment, the integration of real-time data acquisition systems and the commissioning of the IPMs will be discussed. This project provides a versatile diagnostic tool, supporting IOTA’s role as a testbed for larger-scale accelerator facilities and contributing to the broader understanding of beam physics in high-intensity, high-space-charge regimes.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057↗

Simulation of an intracavity Q -switched optical parametric oscillator using rate equations

Based on rate equations we have refined the model of an intracavity Q -switched optical parametric oscillator (IOPO) by taking into account the influence of self-Raman stimulated scattering. The rate equations are solved and analysed in the plane-wave approximation for a Gaussian spatial beam distribution profile under various conditions. The spatial rate equations are also solved numerically for a beam with a field distribution of the TEM{sub 00} mode. The numerical analysis shows that stimulated self-Raman scattering leads to a decrease in the output signal power and an increase in the signal pulse width. This model allows one to predict that the output signal power can be increased with increasing ratio of Raman to fundamental photon lifetimes. This suggests a practical method for determining the self-Raman gain coefficient experimentally. In addition, a multi-pulse process for the signal beam of the IOPO can be regenerated by the presented model. However, in comparison with the previous research, the presented model is more accurate and allows one to design and optimise single-resonator IOPOs.The bibliography includes 25 references. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ITER Toroidal Interferometer and Polarimeter (TIP) beam refraction in 3D density profiles

Calculations of the expected refraction of the five ITER Toroidal Interferometer and Polarimeter (TIP) chords are presented for a range of conditions including high-density axisymmetric, ELMing H-mode cases and shattered pellet disruption mitigation cases. The calculations are carried out with a newly developed ray tracing code capable of following TIP’s 10.59 μm laser beams through arbitrary 3D electron density profiles. Using JOREK simulations of ELM density perturbations in a 15MA ITER baseline plasma, it is shown that refraction from ELMs is expected to be negligible. It is found, however, that TIP interferometers will be able to clearly resolve the line-integrated density perturbation from ELMs and contribute to the ITER measurement requirement “14. H-mode, ELMs and L-H mode transition indicator”. Calculations of the expected refraction in a NIMROD simulated shattered pellet disruption mitigation scenario with peak local electron densities of n e = 3.7 x 10 21 m -3 (max line-averaged densities of n avg = 1.3 x 10 21 m -3 ) also show tolerable refraction and it is likely that most, if not all chords, would avoid signal loss. In conclusion, for both axisymmetric and structured plasmas with line-averaged densities in the mid to upper 10 21 m -3 range, values likely present only during disruption mitigation, refraction becomes significant and could limit the ability of TIP to make reliable density measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility of RACT for 3D dose measurement and range verification in a water phantom

Purpose: The objective of this study is to establish the feasibility of using radiation-induced acoustics to measure the range and Bragg peak dose from a pulsed proton beam. Simulation studies implementing a prototype scanner design based on computed tomographic methods were performed to investigate the sensitivity to proton range and integral dose. Methods: Derived from thermodynamic wave equation, the pressure signals generated from the dose deposited from a pulsed proton beam with a 1 cm lateral beam width and a range of 16, 20, and 27 cm in water using Monte Carlo methods were simulated. The resulting dosimetric images were reconstructed implementing a 3D filtered backprojection algorithm and the pressure signals acquired from a 71-transducer array with a cylindrical geometry (30 × 40 cm) rotated over 2π about its central axis. Dependencies on the detector bandwidth and proton beam pulse width were performed, after which, different noise levels were added to the detector signals (using 1 μs pulse width and a 0.5 MHz cutoff frequency/hydrophone) to investigate the statistical and systematic errors in the proton range (at 20 cm) and Bragg peak dose (of 1 cGy). Results: The reconstructed radioacoustic computed tomographic image intensity was shown to be linearly correlated to the dose within the Bragg peak. And, based on noise dependent studies, a detector sensitivity of 38 mPa was necessary to determine the proton range to within 1.0 mm (full-width at half-maximum) (systematic error < 150 μm) for a 1 cGy Bragg peak dose, where the integral dose within the Bragg peak was measured to within 2%. For existing hydrophone detector sensitivities, a Bragg peak dose of 1.6 cGy is possible. Conclusions: This study demonstrates that computed tomographic scanner based on ionizing radiation-induced acoustics can be used to verify dose distribution and proton range with centi-Gray sensitivity. Realizing this technology into the clinic has the potential to significantly impact beam commissioning, treatment verification during particle beam therapy and image guided techniques.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-778: Use of the 2D MatriXX Detector for Measuring Scanned Ion Beam Parameters

Purpose: The quality assurance (QA) procedure has to check the most relevant beam parameters to ensure the delivery of the correct dose to patients. Film dosimetry, which is commonly used for scanned ion beam QA, does not provide immediate results. The purpose of this work is to answer whether, for scanned ion beam therapy, film dosimetry can be replaced with the 2D MatriXX detector as a real-time tool. Methods: MatriXX, equipped with 32×32 parallel plate ion-chambers, is a commercial device intended for pre-treatment verification of conventional radiation therapy.The MatriXX, placed at the isocenter, and GAFCHROMIC films, positioned on the MatriXX entrance, were exposed to 131.44 MeV proton and 221.45 MeV/u Carbon-ion beams.The OmniPro-I’mRT software, applied for the data taking of MatriXX, gives the possibility of acquiring consecutive snapshots. Using the NI LabVIEW, the data from snapshots were logged as text files for further analysis. Radiochromic films were scanned with EPSON scanner and analyzed using software programs developed in-house for comparative purposes. Results: The field dose uniformity, flatness, beam position and beam width were investigated. The field flatness for the region covering 6×6 cm{sup 2} square field was found to be better than 2%. The relative standard deviations, expected to be constant over 2×2, 4×4 and 6×6 pixels from MatriXX measurement gives a uniformity of 1.5% in good agreement with the film results.The beam center position is determined with a resolution better than 200 µm for Carbon and less than 100 µm for proton beam.The FWHM determination for a beam wider than 10 mm is satisfactory, whilst for smaller beams the determination is uncertain. Conclusion: Precise beam position and fast 2D dose distribution can be determined in real-time using MatriXX detector. The results show that MatriXX is quick and accurate enough to be used in charged-particle therapy QA.

60 APPLIED LIFE SCIENCES↗

Development of an x-ray Talbot-Lau moiré deflectometer for fast density profile measurements of dense plasmas generated by beam-target interactions

We report that for the first time an x-ray Talbot-Lau moiré deflectometer is being developed that will use a flash tube source and fast detector for dynamic density gradient measurements. In Talbot-Lau moiré deflectometry, an x-ray grating makes an image of itself on a second grating (the Talbot effect) to produce a moiré pattern on a detector. The test object is placed between these gratings, with variations in index of refraction changing the pattern. A third grating in front of an incoherent x-ray source produces an array of coherent sources. With a 150 kV x-ray flash tube as the source, the gratings are placed in a glancing angle setup for performance at ~60 keV. The detector is a gated CCD with a fast scintillator for x-ray conversion. This diagnostic, designed for the Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) at Los Alamos National Laboratory, measures the density profile of dense plasma plumes ejected from beam-target interactions. DARHT has two high-current, pulsed, inductive linear electron accelerators with bremsstrahlung targets at the end of each beam line to create 2-D radiographic images of hydrodynamic tests. One multi-pulse accelerator has up to four beam pulses striking the same target within 2 μs. Computer simulations that model target evolution and ejected material between pulses are used to design these targets for optimal radiographic performance; the x-ray deflectometer will directly measure density gradients in the ejected plumes and provide the first experimental constraints to these models. During the first year, currently underway, the diagnostic systems are being designed. In year two, the flash tube and fast detector will be deployed at DARHT for radiographic imaging while the deflectometer is built and tested on the bench with a continuous source. In year three, the fast deflectometer will be installed on DARHT and density measurements will be performed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comparison of phantom scatter from flattened and flattening filter free high-energy photon beams

Flattening filter free (FFF) photon beams have different dosimetric properties from those of flattened beams. The aim of this work was to characterize the collimator scatter (S{sub c}) and total scatter (S{sub cp}) from 3 FFF beams of differing quality indices and use the resulting mathematical fits to generate phantom scatter (S{sub p}) data. The similarities and differences between S{sub p} of flattened and FFF beams are described. S{sub c} and S{sub cp} data were measured for 3 flattened and 3 FFF high-energy photon beams (Varian 6 and 10 MV and Elekta 6 MV). These data were fitted to logarithmic power law functions with 4 numerical coefficients. The agreement between our experimentally determined flattened beam S{sub p} and published data was within ± 1.2% for all 3 beams investigated and all field sizes from 4 × 4 to 40 × 40 cm{sup 2}. For the FFF beams, S{sub p} was only within 1% of the same flattened beam published data for field sizes between 6 × 6 and 14 × 14 cm{sup 2}. Outside this range, the differences were much greater, reaching − 3.2%, − 4.5%, and − 4.3% for the fields of 40 × 40 cm{sup 2} for the Varian 6-MV, Varian 10-MV, and Elekta 6-MV FFF beams, respectively. The FFF beam S{sub p} increased more slowly with increasing field size than that of the published and measured flattened beam of a similar reference field size quality index, i.e., there is less Phantom Scatter than that found with flattened beams for a given field size. This difference can be explained when the fluence profiles of the flattened and FFF beams are considered. The FFF beam has greatly reduced fluence off axis, especially as field size increases, compared with the flattened beam profile; hence, less scatter is generated in the phantom reaching the central axis.

61 RADIATION PROTECTION AND DOSIMETRY↗