Requirements and design of the graphite/epoxy structural elements for the optical telescope assembly of the space telescope

The production of the Space Telescope's Metering Truss Structure (MTS) and Focal Plane Structure (FPS), which are of graphite/epoxy, is described. Graphite/epoxy laminates were chosen because of their high strength and stiffness, low weight, and a controlled coefficient of thermal expansion approaching zero. Photocopy masters, which are dimensionally accurate and stable photographic reproductions of full size engineering drawings, allowed the exact assembly of bonded or bolted parts by assembly mechanics, cutting costs and speeding production. While moisture absorption, high through-the-thickness coefficient of thermal expansion effects, and labor-intensive layup costs are potentially problematic in some cases, it is expected that solutions can be found through analytical and developmental programs.

Golden, C. T.↗

Cooling Waveguide Flanges in Microwave Transmitters

Flang appendage circulates coolant for conductive heat removal. Flange appendage bore accomodates coolant tube. O-ring surrounds bore; when adjacent waveguide sections are bolted together, continuous conduit is formed for coolant. Pressure release groove in modified flange prevents coolant from entering waveguide should O'ring seal fail.

Chen, B. C.↗

Hole-Center Locating Tool

Tool alines center of new hold with existing hole. Tool marks center of new hole drilled while workpiece is in place. Secured with bolts while hole center marked with punch. Used for field installations where reference points unavailable or work area cramped and not easily accessible with conventional tools.

Senter, H. F.↗

Torque-Wrench Extension Arm

Torque-wrench extension arm makes possible to apply torque to bolt, screw, or nut inaccessible to conventional wrenches or in areas where wrench cannot be manipulated. Used in narrow pockets and behind panels and walls.

Pacala, T. J.↗

Internally Mounting Strain Gages

Technique for mounting strain gages inside bolt or cylinder simultaneously inserts gage, attached dowel segment, and length of expandable tubing. Expandable tubing holds gage in place while adhesive cures, assuring even distribution of pressure on gage and area gaged.

Jett, J. R., Jr.↗

Fatigue and fracture research in composite materials

The fatigue, fracture, and impact behavior of composite materials are investigated. Bolted and bonded joints are included. The solutions developed are generic in scope and are useful for a wide variety of structural applications. The analytical tools developed are used to demonstrate the damage tolerance, impact resistance, and useful fatigue life of structural composite components. Standard tests for screening improvements in materials and constituents are developed.

T. Kevin O'Brien↗

Design, fabrication and test of graphite/polyimide composite joints and attachments

The design, analysis, and testing performed to develop four types of graphite/polyimide (Gr/PI) bonded and bolted composite joints for lightly loaded control surfaces on advanced space transportation systems that operate at temperatures up to 561 K (550 F) are summarized. Material properties and small specimen tests were conducted to establish design data and to evaluate specific design details. Static discriminator tests were conducted on preliminary designs to verify structural adequacy. Scaled up specimens of the final joint designs, representative of production size requirements, were subjected to a series of static and fatigue tests to evaluate joint strength. Effects of environmental conditioning were determined by testing aged (125 hours at 589 K (600 F)) and thermal cycled (116 K to 589 K (-250 F to 600 F), 125 times) specimens. It is concluded Gr/PI joints can be designed and fabricated to carry the specified loads. Test results also indicate a possible resin loss or degradation of laminates after exposure to 589 K (600 F) for 125 hours.

Cushman, J. B.↗

Design, fabrication and test of graphite/polymide composite joints and attachments: Summary

The design, analysis and testing performed to develop four types of graphite/polyimide (Gr/PI) bonded and bolted composite joints for lightly loaded control surfaces on advanced space transportation systems that operate at temperatures up to 561K (550 F) are summarized. Material properties and 'small specimen' tests were conducted to establish design data and to evaluate specific design details. 'Static discriminator' tests were conducted on preliminary designs to verify structural adequacy. Scaled up specimens of the final joint designs, representative of production size requirements, were subjected to a series of static and fatigue tests to evaluate joint strength. Effects of environmental conditioning were determined by testing aged (125 hours 589K (600 F)) and thermal cycled (116K to 589K (-250 F to 600 F), 125 times) specimens. It is concluded Gr/PI joints can be designed and fabricated to carry the specified loads. Test results also indicate a possible resin loss or degradation of laminates after exposure to 589K (600 F) for 125 hours.

Cushman, J. B.↗

Low-cost composite blades for the Mod-0A wind turbines

Low cost approaches to the design and fabrication of blades for a two-bladed 200 kW wind turbine were identified and the applicability of the techniques to larger and smaller blades was assessed. Blade tooling was designed and fabricated. Two complete blades and a partial blade for tool tryout were built. The patented TFT process was used to wind the entire blade. This process allows rapid winding of an axially oriented composite onto a tapered mandrel, with tapered wall thickness. The blade consists of a TFT glass-epoxy airfoil structure filament wound onto a steel root end fitting. The fitting is, in turn, bolted to a conical steel adapter section to provide for mounting attachment to the hub. Structural analysis, blade properties, and cost and weight analysis are described.

Weingart, O.↗

Structural fatigue test results for large wind turbine blade sections

In order to provide quantitative information on the operating life capabilities of wind turbine rotor blade concepts for root-end load transfer, a series of cantilever beam fatigue tests was conducted. Fatigue tests were conducted on a laminated wood blade with bonded steel studs, a low cost steel spar (utility pole) with a welded flange, a utility pole with additional root-end thickness provided by a swaged collar, fiberglass spars with both bonded and nonbonded fittings, and, finally, an aluminum blade with a bolted steel fitting (Lockheed Mod-0 blade). Photographs, data, and conclusions for each of these tests are presented. In addition, the aluminum blade test results are compared to field failure information; these results provide evidence that the cantilever beam type of fatigue test is a satisfactory method for obtaining qualitative data on blade life expectancy and for identifying structurally underdesigned areas (hot spots).

Faddoul, J. R.↗

Compression panel studies for supersonic cruise vehicles

Results of analytical and experimental studies are summarized for titanium, boron fiber reinforced aluminum matrix composite, Borsic fiber reinforced aluminum matrix composite, and titanium sheathed Borsic fiber reinforced aluminum matrix composite stiffened panels. The results indicate that stiffened panels with continuous joints (i.e., brazed, diffusion bonded or adhesive bonded joints) are more structurally efficient than geometrically similar panels with discrete joints (i.e., spotwelded or bolted joints). In addition, results for various types of fiber reinforced aluminum matrix stiffened panels indicate that titanium sheathed Borsic fiber reinforced aluminum matrix composite panels are the most structurally efficient. Analytical results are also presented for graphite fiber reinforced polyimide matrix composite stiffened panels and superplastically formed and diffusion bonded titanium sandwich panels.

Mcwithey, R. R.↗

Demonstration of repairability and repair quality on graphite/epoxy structural subelements

The considered program has the objective to develop and validate repair procedures for composite structures which are adaptable to commercial airline maintenance operations. Questions concerning the design and the fabrication of repairs are discussed, taking into account a vertical fin cover panel, a wing cover panel, and a vertical fin spar. The test results indicate that the use of graphite patch repairs, either precured bonded or employing cure-in-place, is satisfactory for the repair of lightly loaded and highly loaded parts. The use of bolted repairs is satisfactory for lightly loaded structural components. The repair of composite substructures can be accomplished using comparable approaches to those evaluated for skin cover repairs in many previous programs.

Knauss, J. F.↗

Thermal conductance of pressed contacts at liquid helium temperatures

It is pointed out that the optimum design of cryogenic instruments requires accurate thermal models. The present models are limited by a lack of knowledge of the low temperature thermal conductance of the bolted joints which are typically used in the instrument-to-system interface. In connection with studies of pressed contacts, it has been found that the thermal conductance does not obey the Wiedemann-Franz law. The present investigation is concerned with the characterization of the thermal conductance of pressed contacts at liquid helium-4 temperatures, taking into account the dependence of thermal contact conductance on applied force and temperature. It is shown that for the 0.4 micron OFHC copper pressed contact pair, the thermal conductance varies roughly as the second power of the temperature, and increases with increasing applied force.

Salerno, L. J.↗

Acoustic Sorter for Small Parts

Sorting system uses acoustic reasonance chamber, detects, and rejects anomalous parts on automated assembly line. System particularly suited to small nuts, bolts, pins, and assemblies which previously required expensive three dimensional television-monitoring systems to prevent misfeeds.

Wang, T. G.↗

Clamp-mount device

A clamp-mount device is disclosed for mounting equipment to an associated I-beam and the like structural member of the type having oppositely extending flanges wherein the device comprises a base and a pair of oppositely facing clamping members carried diagonally on the base clamping flanges therebetween and having flange receiving openings facing one another. Lock means are carried diagonally by the base opposite the clamping members locking the flanges in the clamping members. A resilient hub is carried centrally of the base engaging and biasing a back side of the flanges maintaining tightly clamped and facilitating use on vertical as well as horizontal members. The base turns about the hub to receive the flanges within the clamping members. Equipment may be secured to the base by any suitable means such as bolts in openings. Slidable gate latches secure the hinged locks in an upright locking position. The resilient hub includes a recess opening formed in the base and a rubber-like pad carried in this opening being depressably and rotatably carried therein.

Clark, K. H.↗

Corrosion fatigue of high strength fastener materials in seawater

Environmental effects which significantly reduce the fatigue life of metals are discussed. Corrosion fatigue is a major concern in the engineering application of high strength fasteners in marine environments. The corrosion fatigue failure of an AISI 41L4O high strength steel blade to hub attachment bolt at the MOD-OA 200 kW wind turbine generator was investigated. The reduction of fatigue strength of AISI 41L4O in marine environments and to obtain similar corrosion fatigue data for candidate replacement materials was studied. The AISI 4140, PH 13-8Mo stainless steel, alloy 718 and alloy MP-35N were tested in axial fatigue at a frequency of 20 Hz in dry air and natural seawater. The fatigue data are fitted by regression equations to allow determination of fatigue strength for a given number of cycles to failure.

Tipton, D. G.↗

A versatile structure for GAS payloads

A strong, square cross-section, central column to which experimental and accessory compartments are attached is described. The attachment may be by direct bolting or through vibration and/or thermal isolators, as needed. Structural and thermal characteristics are evaluated.

Punwani, K. G.↗

Side Shield for Wall Support

Method employs curved shield on each side of mining machine. In stowed position, shield folded against roof-support columns on one side. In deployed position, shield raised and braced against coal-seam wall by hydraulic cylinder. Shield supports wall until roof and wall properly secured by bolting and cement coating.