Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

EXILL—a high-efficiency, high-resolution setup for γ-spectroscopy at an intense cold neutron beam facility

In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of γ-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 10 8 n s -1 cm -2 at the target position and negligible neutron halo. The target was surrounded by an array of eight to ten anti-Compton shielded EXOGAM Clover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr 3 :(Ce) detectors from the FATIMA collaboration. The detectors were arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 × 10 5 Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr 3 :(Ce) detectors to analyze half-lives of excited levels in the pico- to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of 133 Ba, 60 Co and 152 Eu as well as data from the reactions 27 Al(n,γ) 28 Al and 35 Cl(n,γ) 36 Cl in the energy range from 30 keV up to 10 MeV.

47 OTHER INSTRUMENTATION↗

Microwave thermal noise standards.

Microwave thermal noise standards, discussing construction, calibration and errors for field operational liquid nitrogen cooled waveguide noise standard

Stelzried, C. T.↗

NASA/American Cancer Society High-Resolution Flow Cytometry Project-I

BACKGROUND: The NASA/American Cancer Society (ACS) flow cytometer can simultaneously analyze the electronic nuclear volume (ENV) and DNA content of cells. This study describes the schematics, resolution, reproducibility, and sensitivity of biological standards analyzed on this unit. METHODS: Calibrated beads and biological standards (lymphocytes, trout erythrocytes [TRBC], calf thymocytes, and tumor cells) were analyzed for ENV versus DNA content. Parallel data (forward scatter versus DNA) from a conventional flow cytometer were obtained. RESULTS: ENV linearity studies yielded an R value of 0.999. TRBC had a coefficient of variation (CV) of 1.18 +/- 0.13. DNA indexes as low as 1.02 were detectable. DNA content of lymphocytes from 42 females was 1.9% greater than that for 60 males, with a noninstrumental variability in total DNA content of 0.5%. The ENV/DNA ratio was constant in 15 normal human tissue samples, but differed in the four animal species tested. The ENV/DNA ratio for a hypodiploid breast carcinoma was 2.3 times greater than that for normal breast tissue. CONCLUSIONS: The high-resolution ENV versus DNA analyses are highly reliable, sensitive, and can be used for the detection of near-diploid tumor cells that are difficult to identify with conventional cytometers. ENV/DNA ratio may be a useful parameter for detection of aneuploid populations.

NASA Center JSC↗

Photometric cross-calibration of the SDSS Stripe 82 Standard Stars catalogue with Gaia EDR3, and comparison with Pan-STARRS1, DES, CFIS, and GALEX catalogues

ABSTRACT We extend the SDSS Stripe 82 Standard Stars catalogue with post-2007 SDSS imaging data. This improved version lists averaged SDSS ugriz photometry for nearly a million stars brighter than r ∼ 22 mag. With 2–3 times more measurements per star, random errors are 1.4–1.7 times smaller than in the original catalogue, and about three times smaller than for individual SDSS runs. Random errors in the new catalogue are $\lesssim$0.01 mag for stars brighter than 20.0, 21.0, 21.0, 20.5, and 19.0 mag in u, g, r, i, and z-bands, respectively. We achieve this error threshold by using the Gaia Early Data Release 3 (EDR3) Gmag photometry to derive grey photometric zeropoint corrections, as functions of RA and Declination, for the SDSS catalogue, and use the Gaia BP–RP colour to derive corrections in the ugiz bands, relative to the r-band. The quality of the recalibrated photometry, tested against Pan-STARRS1, DES, CFIS, and GALEX surveys, indicates spatial variations of photometric zeropoints ≦ 0.01 mag (rms), with typical values of 3–7 millimag in the RA, and 1–2 millimag in the Declination directions, except for $\lesssim$6 millimag scatter in the u-band. We also report a few minor photometric problems with other surveys considered here, including a magnitude-dependent ∼0.01 mag bias between 16 ≤ GGaia ≤ 20 in the Gaia EDR3. Our new, publicly available catalogue offers robust calibration of ugriz photometry below 1 per cent level, and will be helpful during the commissioning of the Vera C. Rubin Observatory Legacy Survey of Space and Time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying and Reducing Curve-Fitting Uncertainty in Isc: Preprint

Current-voltage (I-V) curve measurements of photovoltaic (PV) devices are used to determine performance parameters and to establish traceable calibration chains. Measurement standards specify localized curve fitting methods, e.g., straight-line interpolation/extrapolation of the I-V curve points near short-circuit current, Isc. By considering such fits as statistical linear regressions, uncertainties in the performance parameters are readily quantified. However, the legitimacy of such a computed uncertainty requires that the model be a valid (local) representation of the I-V curve and that the noise be sufficiently well characterized. Using more data points often has the advantage of lowering the uncertainty. However, more data points can make the uncertainty in the fit arbitrarily small, and this fit uncertainty misses the dominant residual uncertainty due to so-called model discrepancy. Using objective Bayesian linear regression for straight-line fits for Isc, we investigate an evidence-based method to automatically choose data windows of I-V points with reduced model discrepancy. We also investigate noise effects. Uncertainties, aligned with the Guide to the Expression of Uncertainty in Measurement (GUM), are quantified throughout.

14 SOLAR ENERGY↗

Quantification of manganese for ChemCam Mars and laboratory spectra using a multivariate model

In this work, we report a new calibration model for manganese using the laser-induced breakdown spectroscopy instrument that is part of the ChemCam instrument suite onboard the NASA Curiosity rover. The model has been trained using an expanded set of 523 manganese-bearing rock, mineral, metal ore, and synthetic standards. The optimal calibration model uses the Partial Least Squares (PLS) and Least Absolute Shrinkage and Selection Operator (LASSO) multivariate techniques, with a novel “double blending” technique. We determined the detection limit for manganese is 82 ppm using a method blank procedure and is possibly as low as 27 ppm based on visual inspection of the spectra. Based on a representative test set consisting of measurements on 93 standards, the double blended multivariate model shows a Root Mean Squared Error of Prediction (RMSEP) accuracy of 1.39 wt% MnO for the full blended model. Employing a local RMSEP estimate where the model performance is evaluated based on nearby test samples, the accuracy is 0.03 wt% at the quantification limit (0.05 wt% MnO), 0.4 wt% accuracy at 1.0 wt% MnO, and 4.4 wt% accuracy at 100 wt% MnO. Precision is estimated using the standard deviation of the test set measurements, and is ±0.01 wt% MnO at the quantification limit, ±0.09 wt% MnO at 1.0 wt% MnO, and ± 2.1 wt% MnO at 100 wt% MnO (all 1 standard deviation). This new calibration is important for understanding the variation of manganese in the bedrock with the Curiosity rover on Mars, which provides insight into past redox conditions on Mars.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The influence of tillage and fertilizer on the flux and source of nitrous oxide with reference to atmospheric variation using laser spectroscopy

Nitrous oxide (N 2 O) is the third most important long-lived greenhouse gas and agriculture is the largest source of N 2 O emissions. Curbing N 2 O emissions requires understanding influences on the flux and sources of N 2 O. We measured flux and evaluated microbial sources of N 2 O using site preference ( S P ; the intramolecular distribution of 15 N in N 2 O) in flux chambers from a grassland tilling and agricultural fertilization experiments and atmosphere. We identified values greater than that of the average atmosphere to reflect nitrification and/or fungal denitrification and those lower than atmosphere as increased denitrification. Our spectroscopic approach was based on an extensive calibration with 18 standards that yielded S P accuracy and reproducibility of 0.7 ‰ and 1.0 ‰, respectively, without preconcentration. Chamber samples from the tilling experiment taken ~ monthly over a year showed a wide range in N 2 O flux (0–1.9 g N 2 O-N ha -1 d -1 ) and S P (- 1.8 to 25.1 ‰). Flux and S P were not influenced by tilling but responded to sampling date. Large fluxes occurred in October and May in no-till when soils were warm and moist and during a spring thaw, an event likely representing release of N 2 O accumulated under snow cover. These high fluxes could not be ascribed to a single microbial process as S P differed among chambers. However, the year-long S P and flux data for no-till showed a slight direct relationship suggesting that nitrification increased with flux. The comparative data in till showed an inverse relationship indicating that high flux events are driven by denitrification. Corn ( Zea mays ) showed high fluxes and S P values indicative of nitrification ~ 4 wk after fertilization with subsequent declines in S P indicating denitrification. Although there was no effect of fertilizer treatment on flux or S P in switchgrass ( Panicum virgatum) , high fluxes occurred ~1 month after fertilization. In both treatments, S P was indicative of denitrification in many instances, but evidence of nitrification/fungal denitrification also prevailed. At 2 m atmospheric N 2 O S P had a range of 31.1 ‰ and 14.6 ‰ in the grassland tilling and agricultural fertilization experiments, respectively. These data suggest the influence of soil microbial processes on atmospheric N 2 O and argue against the use of the global average atmospheric S P in isotopic modeling approaches.

Environmental Sciences & Ecology↗

Measured physical and optical properties of the passive geodetic satellite /Pageos/ and Echo 1.

Two satellites used for geodesy, Pageos and Echo 1, have been observed in a continuing program since 1966 to determine the stability of their physical and optical properties. Measurements are made in the UBVRI spectral system. The amount of solar radiation reflected from a satellite's surface is measured photoelectrically and is calibrated against known stellar magnitudes by standard astronomical techniques. The calibrated satellite magnitudes are analyzed with respect to the sun-satellite-observer phase angle to infer the shape and size of the satellite and the reflective properties of the satellite's surface material. The physical and optical properties are used to determine proper position of the solar image on the satellite's surface, resulting in more precise geometric geodesy. Quantitative results from five observing periods indicate that, although local structural anomalies appear to exist, both satellites essentially maintained their nominal average 30.48-meter (50-ft) radius of curvature and specular reflecting characteristics.

Mcdougal, D. S.↗

Spectrometric Estimation of Total Nitrogen Concentration in Douglas-Fir Foliage

Spectral measurements of fresh and dehydrated Douglas-fir foliage, from trees cultivated under three fertilization treatments, were acquired with a laboratory spectrophotometer. The slope (first-derivative) of the fresh- and dry-leaf absorbance spectra at locations near known protein absorption features was strongly correlated with total nitrogen (TN) concentration of the foliage samples. Particularly strong correlation was observed between the first-derivative spectra in the 2150-2170 nm region and TN, reaching a local maximum in the fresh-leaf spectra of -0.84 at 2 160 nm. Stepwise regression was used to generate calibration equations relating first derivative spectra from fresh, dry/intact, and dry/ground samples to TN concentration. Standard errors of calibration were 1.52 mg g-1 (fresh), 1.33 (dry/intact), and 1.20 (dry/ground), with goodness-of-fit 0.94 and greater. Cross-validation was performed with the fresh-leaf dataset to examine the predictive capability of the regression method; standard errors of prediction ranged from 1.47 - 2.37 mg g(exp -1) across seven different validation sets, prediction goodness of fit ranged from .85-.94, and wavelength selection was fairly insensitive to the membership of the calibration set. All regressions in this study tended to select wavelengths in the 2100-2350 nm region, with the primary selection in the 2142-2172 nm region. The study provides positive evidence concerning the feasibility of assessing TN status of fresh-leaf samples by spectrometric means. We assert that the ability to extract biochemical information from fresh-leaf spectra is a necessary but insufficient condition regarding the use of remote sensing for canopy-level biochemical estimation.

Johnson, Lee F.↗

Calibration of Post-AGB Supergiants as Standard Extragalactic Candles for HST

This report summarizes activities carried out with support from the NASA Ultraviolet, Visible, and Gravitational Astrophysics Research and Analysis Program. The aim of the program is to calibrate the absolute magnitudes of post-asymptotic-giant-branch (post-AGB or PAGB) stars, which we believe will be an excellent new "standard candle" for measuring extragalactic distances. The reason for this belief is that in old populations, the stars that are evolving through the PAGB region of the HR (Hertzsprung-Russell) diagram arise from only a single main-sequence turnoff mass. In addition, the theoretical PAGB evolutionary tracks show that they evolve through this region at constant luminosity; hence the PAGB stars should have an extremely narrow luminosity function. Moreover, as the PAGB stars evolve through spectral types F and A (en route from the AGB to hot stellar remnants and white dwarfs), they have the highest luminosities attained by old stars (both bolometrically and in the visual band). Finally, the PAGB stars of these spectral types are very easily identified, due to their large Balmer jumps, which are due to their very low surface gravities.

Bond, Howard E.↗

Accurate frequency and intensity measurements of the infrared spectra of atmospheric molecules

Various problems encountered and solutions found in infrared laboratory measurements on atmospheric molecules are discussed. The advantages and limitations of various measurement techniques and equipment are discussed, with emphasis placed on calibration techniques and measurement accuracy and precision. Frequency calibration aids are presented, including the current and planned tables of absorption frequency standards being developed by the Bureau of Standards for the calibration of high-resolution devices with an accuracy of + or - 3 MHz. It is noted that intensity measurements are highly susceptible to systematic errors and that great care must be taken to obtain accuracies better than + or - 10%. What is even more difficult is knowing the accuracy of a particular measurement. Recent work done on providing accurate intensity data are described.

Maki, A. G.↗

Spectral Irradiance Calibration in the Infrared: 1.2 - 35 microns Spectra of Six Standard Stars - Part 4

We present five new absolutely calibrated continuous stellar spectra from 1.2 to 35 microns, constructed as far as possible from actual observed spectral fragments taken from the ground, the Kuiper Airborne Observatory (KAO), and the IRAS Low Resolution Spectrometer (LRS). These stars- beta Peg, alpha Boo, beta And, beta Gem, and alpha Hya-augment our already created complete absolutely calibrated spectrum for alpha Tau. All these spectra have a common calibration pedigree. The wavelength coverage is ideal for calibration of many existing and proposed ground-based, airborne, and satellite sensors.

Cohen, Martin↗

Contributed Review: Absolute spectral radiance calibration of fiber-optic shock-temperature pyrometers using a coiled-coil irradiance standard lamp

We describe an accurate and precise calibration procedure for multichannel optical pyrometers such as the 6-channel, 3-ns temporal resolution instrument used in the Caltech experimental geophysics laboratory. We begin with a review of calibration sources for shock temperatures in the 3000-30 000 K range. High-power, coiled tungsten halogen standards of spectral irradiance appear to be the only practical alternative to NIST-traceable tungsten ribbon lamps, which are no longer available with large enough calibrated area. However, non-uniform radiance complicates the use of such coiled lamps for reliable and reproducible calibration of pyrometers that employ imaging or relay optics. Careful analysis of documented methods of shock pyrometer calibration to coiled irradiance standard lamps shows that only one technique, not directly applicable in our case, is free of major radiometric errors. We provide a detailed description of the modified Caltech pyrometer instrument and a procedure for its absolute spectral radiance calibration, accurate to ±5%. We employ a designated central area of a 0.7× demagnified image of a coiled-coil tungsten halogen lamp filament, cross-calibrated against a NIST-traceable tungsten ribbon lamp. We give the results of the cross-calibration along with descriptions of the optical arrangement, data acquisition, and processing. We describe a procedure to characterize the difference between the static and dynamic response of amplified photodetectors, allowing time-dependent photodiode correction factors for spectral radiance histories from shock experiments. We validate correct operation of the modified Caltech pyrometer with actual shock temperature experiments on single-crystal NaCl and MgO and obtain very good agreement with the literature data for these substances. We conclude with a summary of the most essential requirements for error-free calibration of a fiber-optic shock-temperature pyrometer using a high-power coiled tungsten halogen irradiance standard lamp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water isotope data for the TEMPEST study site, 2023-2026

This dataset contains water isotope (deuterium (dD) and oxygen (d18O)) data from porewater, experimental source water, and aquifer sources from the Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental field site in Edgewater, MD. Samples were taken from 2023-2026 and included in file "TEMPEST_Water_Isotope_LANL_2023-2026.csv". Porewater samples were taken from 15cm depth at multiple locations in each experimental plot (i.e., control, freshwater, and saltwater). Water samples were stored in 2 ml amber glass vials with septum caps under refrigeration until analysis. A L2140-i Picarro cavity ringdown spectrometer connected to an A0211 Picarro vaporization module was used to run water samples. Standards (United States Geological Survey (USGS) 47 and 48) were used to check instrument accuracy during each run of samples. Post-processing codes were run to calculate isotopic values from raw data. Reported isotope data is post-processed. Raw data CSV files from the Picarro were processed using a Python script and output as excel files containing data calibrated to Vienna Standard Mean Ocean Water (VSMOW). Standardization is based on USGS47 and USGS48 standards that are measured before and after every 5-10 unknowns. Every measurement is comprised of 10 injections. Processing involved discarding the first 4 injections due to a known memory effect. Raw means of the last 6 injections are taken for each measurement and then corrected from the linear calibration relationship of the USGS standards expected vs measured values to obtain corrected compositions relative to VSMOW. Reported isotope data are corrected mean results.

Aquifer↗

Stress anisotropy and concentration effects in high pressure measurements

Sodium chloride is used as an internal pressure standard in high pressure research. Possible corrections are discussed which are needed in the calibration of this standard due to the independent effects of stress anisotropy and stress concentration in pressure vessels. The first is due to the lack of a truly hydrostatic state of stress in solid state pressure vessels. The second is due to the difference in the compressibilities between the pressure transmitting substances (sodium chloride) and a stiffer test specimen. These two corrections are then combined and a total correction, as a function of measured pressure, is discussed for two systems presently in use. The predicted value of the combined effect is about 5-10% of the pressure at 30 GPa.

Nelson, D. A., Jr.↗