Search NASA⌕ Search

SEARCH · Search NASA

Results for “Code assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

System thermal-hydraulic modelling of the phénix dissymmetric test benchmark

Phénix is a French pool-type sodium-cooled prototype reactor; before the definitive shutdown, occurred in 2009, a final set of experimental tests are carried out in order to increase the knowledge on the operation and the safety aspect of the pool-type liquid metal-cooled reactors. One of the experiments was the Dissymmetric End-of-Life Test which was selected for the validation benchmark activity in the frame of SESAME project. The computer code validation plays a key role in the safety assessment of the innovative nuclear reactors and the Phénix dissymmetric test provides useful experimental data to verify the computer codes capability in the asymmetric thermal-hydraulic behaviour into a pool-type liquid metal-cooled reactor. This paper shows the comparison of the outcomes obtained with six different System Thermal-Hydraulic (STH) codes: RELAP5-3D©, SPECTRA, ATHLET, SAS4A/SASSYS-1, ASTEC-Na and CATHARE. The nodalization scheme of the reactor was individually achieved by the participants; during the development of the thermal-hydraulic model, the pool nodalization methodology had a special attention in order to investigate the capability of the STH codes to reproduce the dissymmetric effects which occur in each loop and into pools, caused by the azimuthal asymmetry of the boundary conditions. The modelling methodology of the participants is discussed and the main results are compared in this paper to obtain useful guide lines for the future modelling of innovative liquid metal pool-type reactors.

42 ENGINEERING↗

System Thermal-Hydraulic Modeling of the Phénix Dissymmetric Test Benchmark

Phénix is a French pool-type sodium-cooled prototype reactor; before the definitive shutdown, occurred in 2009, a final set of experimental tests are carried out in order to increase the knowledge on the operation and the safety aspect of the pool-type liquid metal-cooled reactors. One of the experiments was the Dissymmetric End-of-Life Test which was selected for the validation benchmark activity in the frame of SESAME project. The computer code validation plays a key role in the safety assessment of the innovative nuclear reactors and the Phénix dissymmetric test provides useful experimental data to verify the computer codes capability in the asymmetric thermal-hydraulic behaviour into a pool-type liquid metal-cooled reactor. This paper shows the comparison of the outcomes obtained with six different System Thermal-Hydraulic (STH) codes: RELAP5-3D©, SPECTRA, ATHLET, SAS4A/SASSYS-1, ASTEC-Na and CATHARE. The nodalization scheme of the reactor was individually achieved by the participants; during the development of the thermal-hydraulic model, the pool nodalization methodology had a special attention in order to investigate the capability of the STH codes to reproduce the dissymmetric effects which occurs in each loop and into pools, caused by the azimuthal asymmetry of the boundary conditions. The modelling methodology of the participants is discussed and the main results are compared in this paper to obtain useful guide lines for the future modelling of innovative liquid metal pool-type reactors.

Narcisi, V.↗

Ductile failure X-prize.

Fracture or tearing of ductile metals is a pervasive engineering concern, yet accurate prediction of the critical conditions of fracture remains elusive. Sandia National Laboratories has been developing and implementing several new modeling methodologies to address problems in fracture, including both new physical models and new numerical schemes. The present study provides a double-blind quantitative assessment of several computational capabilities including tearing parameters embedded in a conventional finite element code, localization elements, extended finite elements (XFEM), and peridynamics. For this assessment, each of four teams reported blind predictions for three challenge problems spanning crack initiation and crack propagation. After predictions had been reported, the predictions were compared to experimentally observed behavior. The metal alloys for these three problems were aluminum alloy 2024-T3 and precipitation hardened stainless steel PH13-8Mo H950. The predictive accuracies of the various methods are demonstrated, and the potential sources of error are discussed.

36 MATERIALS SCIENCE↗

Analysis of Radiological Impacts to Terrestrial Biota in Support of Environmental Assessment for Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory

There are many species of plants and animals (biota) on the INL Site and facilities such as INTEC and MFC have surrounding habitat supporting resident plant and animal populations. Consequently, radionuclide releases from the HALEAU processing facilities could pose a potential radiological impact to nearby flora and fauna populations. Therefore, the RESRAD-BIOTA (Version 1.8) computer code (http://resrad.evs.anl.gov/codes/resrad-biota/) was used to assess the impact of radiation exposures to terrestrial biota resulting from soil contaminated by airborne releases from the HALEAU processing facilities proposed for the INTEC and/or MFC complexes. The contaminated soil subsequently results in contamination in air and in different food sources used by biota. Both external radiation and internal radiation are considered in the dose evaluation.

99 GENERAL AND MISCELLANEOUS↗

Cloud Computing for Complex Performance Codes.

This report describes the use of cloud computing services for running complex public domain performance assessment problems. The work consisted of two phases: Phase 1 was to demonstrate complex codes, on several differently configured servers, could run and compute trivial small scale problems in a commercial cloud infrastructure. Phase 2 focused on proving non-trivial large scale problems could be computed in the commercial cloud environment. The cloud computing effort was successfully applied using codes of interest to the geohydrology and nuclear waste disposal modeling community.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Peak Dose Assessment for Proposed DOE-PPPO Authorized Limits

The Oak Ridge Institute for Science and Education (ORISE), a U.S. Department of Energy (DOE) prime contractor, was contracted by the DOE Portsmouth/Paducah Project Office (DOE-PPPO) to conduct a peak dose assessment in support of the Authorized Limits Request for Solid Waste Disposal at Landfill C-746-U at the Paducah Gaseous Diffusion Plant (DOE-PPPO 2011a). The peak doses were calculated based on the DOE-PPPO Proposed Single Radionuclides Soil Guidelines and the DOE-PPPO Proposed Authorized Limits (AL) Volumetric Concentrations available in DOE-PPPO 2011a. This work is provided as an appendix to the Dose Modeling Evaluations and Technical Support Document for the Authorized Limits Request for the C-746-U Landfill at the Paducah Gaseous Diffusion Plant, Paducah, Kentucky (ORISE 2012). The receptors evaluated in ORISE 2012 were selected by the DOE-PPPO for the additional peak dose evaluations. These receptors included a Landfill Worker, Trespasser, Resident Farmer (onsite), Resident Gardener, Recreational User, Outdoor Worker and an Offsite Resident Farmer. The RESRAD (Version 6.5) and RESRAD-OFFSITE (Version 2.5) computer codes were used for the peak dose assessments. Deterministic peak dose assessments were performed for all the receptors and a probabilistic dose assessment was performed only for the Offsite Resident Farmer at the request of the DOE-PPPO. In a deterministic analysis, a single input value results in a single output value. In other words, a deterministic analysis uses single parameter values for every variable in the code. By contrast, a probabilistic approach assigns parameter ranges to certain variables, and the code randomly selects the values for each variable from the parameter range each time it calculates the dose (NRC 2006). The receptor scenarios, computer codes and parameter input files were previously used in ORISE 2012. A few modifications were made to the parameter input files as appropriate for this effort. Some of these changes included increasing the time horizon beyond 1,050 years (yr), and using the radionuclide concentrations provided by the DOE-PPPO as inputs into the codes. The deterministic peak doses were evaluated within time horizons of 70 yr (for the Landfill Worker and Trespasser), 1,050 yr, 10,000 yr and 100,000 yr (for the Resident Farmer [onsite], Resident Gardener, Recreational User, Outdoor Worker and Offsite Resident Farmer) at the request of the DOE-PPPO. The time horizons of 10,000 yr and 100,000 yr were used at the request of the DOE-PPPO for informational purposes only. The probabilistic peak of the mean dose assessment was performed for the Offsite Resident Farmer using Technetium-99 (Tc-99) and a time horizon of 1,050 yr. The results of the deterministic analyses indicate that among all receptors and time horizons evaluated, the highest projected dose, 2,700 mrem/yr, occurred for the Resident Farmer (onsite) at 12,773 yr. The exposure pathways contributing to the peak dose are ingestion of plants, external gamma, and ingestion of milk, meat and soil. However, this receptor is considered an implausible receptor. The only receptors considered plausible are the Landfill Worker, Recreational User, Outdoor Worker and the Offsite Resident Farmer. The maximum projected dose among the plausible receptors is 220 mrem/yr for the Outdoor Worker and it occurs at 19,045 yr. The exposure pathways contributing to the dose for this receptor are external gamma and soil ingestion. The results of the probabilistic peak of the mean dose analysis for the Offsite Resident Farmer indicate that the average (arithmetic mean) of the peak of the mean doses for this receptor is 0.98 mrem/yr and it occurs at 1,050 yr. This dose corresponds to Tc-99 within the time horizon of 1,050 yr.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Risk of Cerebrovascular Events in Elderly Patients After Radiation Therapy Versus Surgery for Early-Stage Glottic Cancer

Purpose: Comprehensive neck radiation therapy (RT) has been shown to increase cerebrovascular disease (CVD) risk in advanced-stage head-and-neck cancer. We assessed whether more limited neck RT used for early-stage (T1-T2 N0) glottic cancer is associated with increased CVD risk, using the Surveillance, Epidemiology, and End Results (SEER)-Medicare linked database. Methods and Materials: We identified patients ≥66 years of age with early-stage glottic laryngeal cancer from SEER diagnosed from 1992 to 2007. Patients treated with combined surgery and RT were excluded. Medicare CPT codes for carotid interventions, Medicare ICD-9 codes for cerebrovascular events, and SEER data for stroke as the cause of death were collected. Similarly, Medicare CPT and ICD-9 codes for peripheral vascular disease (PVD) were assessed to serve as an internal control between treatment groups. Results: A total of 1413 assessable patients (RT, n=1055; surgery, n=358) were analyzed. The actuarial 10-year risk of CVD was 56.5% (95% confidence interval 51.5%-61.5%) for the RT cohort versus 48.7% (41.1%-56.3%) in the surgery cohort (P=.27). The actuarial 10-year risk of PVD did not differ between the RT (52.7% [48.1%-57.3%]) and surgery cohorts (52.6% [45.2%-60.0%]) (P=.89). Univariate analysis showed an increased association of CVD with more recent diagnosis (P=.001) and increasing age (P=.001). On multivariate Cox analysis, increasing age (P<.001) and recent diagnosis (P=.002) remained significantly associated with a higher CVD risk, whereas the association of RT and CVD remained not statistically significant (HR=1.11 [0.91-1.37,] P=.31). Conclusions: Elderly patients with early-stage laryngeal cancer have a high burden of cerebrovascular events after surgical management or RT. RT and surgery are associated with comparable risk for subsequent CVD development after treatment in elderly patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LPG Component Leak Frequency Estimation

Liquefied petroleum gas (LPG) is used in heating, cooking, and as a vehicle fuel (called autogas). A safety risk assessment may be needed to assess potential hazard scenarios and inform the regulations, codes, and standards that apply to LPG facilities, such as autogas refueling facilities. The frequency of unintended releases in an LPG system is an important aspect of a system quantitative risk assessment. This report documents estimation of leakage frequencies for individual components of LPG systems. These frequencies are described using uncertainty distributions obtained with Bayesian statistical methods, generic data, and LPG data which were publicly available. There was a lack of LPG data in the literature, so frequencies for most components were developed with generic data and should be used cautiously; without additional information about component leak frequencies in LPG systems, it is not known whether these generic frequencies may be conservative or non-conservative.

02 PETROLEUM↗

MELCOR 2.2 Benchmarks of Peach Bottom NUREG/CR 7155 Uncertainty Analysis

The U.S. Nuclear Regulatory Commission (NRC) performed a first-of-a-kind uncertainty analysis (UA) of the accident progression, radiological releases, and offsite consequences for the State-of- the-Art Reactor Consequence Analyses (SOARCA) of an unmitigated long-term station blackout (LTSBO) severe accident scenario at the Peach Bottom Atomic Power Station. The objective of the UA was to evaluate the robustness of the SOARCA deterministic "best estimate results and conclusions documented in NUREG-1935, and to develop insight into the overall sensitivity of the SOARCA results to uncertainty in key modeling inputs. The study was completed in 2015 and documented in NUREG/CR-7155. Since 2015, two other SOARCA UAs were completed for two pressurized water reactor (PWR) plants. The PWR UAs incrementally updated the approach and methodology, including using the latest release of the MELCOR 2.2 computer code. There were also advances made in the state-of-the-art modeling related to NRC efforts using the Peach Bottom model in NUREG-2206, which provided the technical basis for the containment protection and release reduction rulemaking for boiling water reactors with Mark I and Mark II containments. This report documents the input model changes from the NUREG/CR-7155 study and performs a small number of reference calculations to assess the changes of the new computer code and the model input updates. The objective of the work is to verify whether the updated Peach Bottom MELCOR model and updated version of MELCOR support the conclusions formed in the Peach Bottom SOARCA UA by performing these representative calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Generation of group constants at GRS for the Rostov-2 benchmark

The OECD/NEA benchmark entitled 'Reactivity compensation of boron dilution by stepwise insertion of control rod cluster into the VVER-1000 core' aims at validating and assessing high fidelity multi-physics simulation code capabilities by comparison with the high-quality measurements performed at the nuclear power plant Rostov unit 2. The benchmark is divided into 2 phases: assembly wise and pin-by-pin resolution of the multi-physics problems. Multi-physics simulation requires the generation of an accurate parametrized few-group cross-section library, and so this benchmark offers an opportunity to validate the methodology for their generation. Based on the specifications of the benchmark, the core simulator KMACS developed at GRS was used to generate a library of cross-sections as well as the burnup distribution required to model the transient scenario of the benchmark at the assembly level. The assessment of the library is performed through comparison with measured values obtained at the initial state of the transient. Good agreement was obtained in terms of critical boron concentration, peaking factors and power profiles. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Combining RAVEN, RELAP5-3D, and PHISICS for Fuel Cycle and Core Design Analysis for New Cladding Criteria

The Nuclear Regulatory Commission (NRC) has considered revision of 10 CFR 50.46C rule to account for the effects of burn-up rate in future analysis of reactor accident scenarios so that safety margins may evolve with the operation and reloading of the reactor as dynamic limits. In order to find these limiting conditions, both cladding oxidation and maximum temperature must be cast as functions of fuel exposure. It is computationally intensive to run a plant model through a long duration operational transient to the time of fuel reload, and this must be repeated for each reload until the time of the accident scenario. Moreover, fuel reload patterns may differ in many ways so that calculations with many different core configurations must be considered. To perform such new analyses in a reasonable amount of computational time with good accuracy, Idaho National Laboratory (INL) has developed new multi-physics tools by combining existing codes and adding new capabilities. The Parallel Highly Innovative Simulation INL Code System (PHISICS) toolkit for neutronic and reactor physics is coupled with the Reactor Excursion and Leak Analysis Program (RELAP5-3D) for the Loss of Coolant Accident (LOCA) analysis and RAVEN for the Probabilistic Risk Assessment (PRA) and margin characterization analysis. Expansion of code capability was also necessary. For RELAP5-3D to process a single sequence of cores in a continuous run required modification of RELAP5-3D to restart a sequence of input decks, each with a slightly modified neutronics model or thermal-hydraulic flow region and culminating in an accident scenario. A new multi-deck input processing capability was developed and verified for this analysis. In conclusion, the combined RAVEN/PHISICS/RELAP5-3D tool is used to analyze a typical Pressurized Water Reactor (PWR).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A NEAR-INFRARED SPECTROSCOPIC SURVEY OF K-SELECTED GALAXIES AT z{approx} 2.3: COMPARISON OF STELLAR POPULATION SYNTHESIS CODES AND CONSTRAINTS FROM THE REST-FRAME NIR

We present spectral energy distribution (SED) modeling of a sample of 34 K-selected galaxies at z{approx} 2.3. These galaxies have near-infrared (NIR) spectroscopy that samples the rest-frame Balmer/4000 A break as well as deep photometry in 13 broadband filters. New to our analysis is Infrared Array Camera (IRAC) data that extend the SEDs into the rest-frame NIR. Comparing parameters determined from SED fits with and without the IRAC data we find that the IRAC photometry significantly improves the confidence intervals of {tau}, A{sub v} , M {sub star}, and SFR for individual galaxies, but does not systematically alter the mean parameters of the sample. We use the IRAC data to assess how well current stellar population synthesis codes describe the rest-frame NIR SEDs of young galaxies where discrepancies between treatments of the thermally pulsating asymptotic giant branch phase of stellar evolution are most pronounced. The models of Bruzual and Charlot, Maraston, and Charlot and Bruzual all successfully reproduce the SEDs of our galaxies with {<=}5% differences in the quality of fit; however, the best-fit masses from each code differ systematically by as much as a factor of 1.5, and other parameters vary more, up to factors of 2-3. A comparison of best-fit stellar population parameters from different stellar population synthesis (SPS) codes, dust laws, and metallicities shows that the choice of SPS code is the largest systematic uncertainty in most parameters, and that systematic uncertainties are typically larger than the formal random uncertainties. The SED fitting confirms our previous result that galaxies with strongly suppressed SF account for {approx}50% of the K-bright population at z{approx} 2.3; however, the uncertainty in this fraction is large due to systematic differences in the specific star formation rates derived from the three SPS models.

79 ASTRONOMY AND ASTROPHYSICS↗

Fitness For Service Assessment of a Corroded Heat Exchanger

Within the Fermi National Accelerator complex, there exist various water systems that support accelerator operations. One of these systems is extremely vital to the operation of the machine; that is the cooling system. The cooling system consists of nine relatively large heat exchangers that take untreated pond water and use it to cool the process fluid that further cools machine components. Over the 30 years these heat exchangers have been in operation, they have undergone significant material loss on the channels. This material loss, due to various forms of corrosion such as galvanic and microbiologically influenced corrosion (MIC) and possibly others, has deteriorated more than 80% of the nominal wall thickness of some of the exchangers and placed them in a questionable state. ASME FFS-1 (API 579) has been applied to address the condition of the heat exchangers due to their noncompliance with the governing code, BPVC Sec. VIII Div. 1. The assessments encompassed ASME FFS-1 parts 4: General Metal Loss and 9: Crack Like Flaw using level 1, 2, and 3 analysis techniques based on inspection data obtained by API 510 inspections. Level 1 and 2 assessments were deemed unfit for the corroded regions due to their location relative to a major structural discontinuity (channel to tube-sheet joint), so a level 3 analysis was conducted according to ASME Sec. VIII Div. 2 (design by analysis) rules for pressure vessels. Supplemental information included pond water tests to determine an accurate future corrosion allowance due to lacking inspection history. A leak before break (LBB) route was chosen to evaluate the possibility of leaking prior to the onset of failure. The analysis of one heat exchanger shows that the possibility the channel will develop a pinhole leak over 2.5 more years of operation should not be overlooked, but burst was unlikely from operation. The use of fracture mechanics show, that if a through-wall crack were to develop, it would not propagate further than the channel geometry and cause a leak not greater than 35 GPM. Using ASME Section XI Code Case N-705-1, allowing us to operate with a leak until the next outage given certain operating conditions and developing a leak mitigation procedure, this heat exchanger is deemed fit-for-service.

Humenik, Alex [Fermilab]↗

Model of temperature, evaporation, and productivity in elevated experimental algae raceways and comparison with commercial raceways

Elevated Experimental Raceways (EERs) have been used at many research sites in the United States to evaluate algal biomass productivity. This paper develops temperature and evaporation models for EERs and then evaluates whether the temperature profile and resultant productivity in an EER is representative of large-scale commercial raceways. Open water surface evaporation and temperature models with shading algorithms were programmed in Python and calibrated with temperature and evaporation data from the EERs in the Regional Algal Feedstock Testbed (RAFT) experiments at the University of Arizona. The final calibrated model for EERs was named the EERTEM (Elevated Experimental Raceway Temperature and Evaporation Model). The energy balance algorithms in the Biomass Assessment Tool (BAT model) were also added to the Python code and used to develop temperature simulations of standard commercial paddlewheel raceways. A comparison of BAT and EERTEM simulations indicated that EER temperature fluctuations are not representative of in ground commercial paddlewheel raceways, primarily due to the buffering effect of soil heat flux in commercial raceways. With the different temperature profiles, biomass productivities of three algae species in the EERs were compared to productivities in commercial raceways. Differences in productivity between EERTEM and BAT model temperature profiles were observed when the maximum daytime temperature of one raceway was in the optimal growth range but the temperature of the other raceway exceeded or was below the optimal growth range.

Khawam, George↗

Metallic Fuel Performance Code Requirements for the Versatile Test Reactor Project

Metallic nuclear fuels have been proposed for use in several emerging nuclear reactor designs, and a number of codes have been developed to model these fuels and assess their performance. Qualification of these metallic nuclear fuels will ultimately require monitored irradiation of lead test assemblies, but the use of fuel performance codes can reduce the uncertainty associated with these efforts by quantifying uncertainties and estimating margins to failure ahead of time. In this work, metallic fuel performance code requirements are defined for the Versatile Test Reactor (VTR) project using input from the Experimental Breeder Reactor II functional requirements, operational requirements, and design criteria. This work focuses on the thermomechanical responses and irradiation behaviors of metallic fuel elements that are representative of the proposed VTR driver fuel design concepts. As such, many of the code requirements and physics/modeling discussions in this work are expected to be broadly applicable to metallic fuel applications outside of the VTR project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-to-Low Activities across VVI, AMA and PHI

This milestone report documents work performed in CASL that was broadly focused on the use of validated high-fidelity simulation codes to inform, improve and calibrate low-fidelity codes to facilitate multiphysics coupling, design, performance analysis, and risk assessment. This high-to-low (Hi2Lo) initiative has the following objectives: employ physics encapsulated in high-fidelity codes to improve the functionality of low-fidelity codes, quantify biases in low-fidelity codes, develop and calibrate physical models and closure relations so that low-fidelity codes more accurately incorporate requisite physics, and develop low-fidelity codes that can be effectively coupled to simulate multiphysics behavior. In combination, these efforts are designed to impact both CIPS and DNB. For example, the development and experimental design-based Bayesian calibration of dynamic gas conductance models in CTFFuel will provide the capability to better model crud-induced power shifts. Whereas the present emphasis has focused on the high-fidelity codes STAR-CCM+ and BISON and low-fidelity codes CTF and CTFFuel, future emphasis will be expanded to include MAMBA. During the reporting period, Hi2Lo efforts focused on two broad components: demonstration of the experimental design-based Bayesian calibration framework to calibrate CTF using both STAR-generated synthetic data and experimental data, and the use of STAR to inform and improve the turbulence modeling and grid heat transfer modeling capabilities in CTF. A complementary milestone focused on the implementation and verification of fuel models in CTFFuel, for which we demonstrated initial calibration results. Future Hi2Lo work will focus on the use of the experimental design-based Bayesian calibration framework, demonstrated this year for STAR and CTF, to calibrate parameters in the fuel swelling, fuel irradiation-induced densification, and fuel relocation models in CTFFuel using both experimental and BISON-generated data. A second component will focus on the continued use of STAR to improve grid modeling capabilities in CTF.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗