Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Deep reinforcement learning control for co-optimizing energy consumption, thermal comfort, and indoor air quality in an office building

With the recent demand for decarbonization and energy efficiency, advanced HVAC control using Deep Reinforcement Learning (DRL) becomes a promising solution. Due to its flexible structures, DRL has been successful in energy reduction for many HVAC systems. However, only a few researches applied DRL agents to manage the entire central HVAC system and control multiple components in both the water loop and the air loop, owing to its complex system structures. Moreover, those researches have not extended their applications by incorporating the indoor air quality, especially both CO2 and PM2.5concentrations, on top of energy saving and thermal comfort, as achieving those objectives simultaneously can cause multiple control conflicts. What's more, DRL agents are usually trained on the simulation environment before deployment, so another challenge is to develop an accurate but relatively simple simulator. Therefore, we propose a DRL algorithm for a central HVAC system to co-optimize energy consumption, thermal comfort, indoor CO2 level, and indoor PM2.5 level in an office building. To train the controller, we also developed a hybrid simulator that decoupled the complex system into multiple simulation models, which are calibrated separately using laboratory test data. The hybrid simulator combined the dynamics of the HVAC system, the building envelope, as well as moisture, CO2, and particulate matter transfer. Three control algorithms (rule-based, MPC, and DRL) are developed, and their performances are evaluated on the hybrid simulator environment with a realistic scenario (i.e., with stochastic noises). The test results showed that, the DRL controller can save 21.4 % of energy compared to a rule-based controller, and has improved thermal comfort, reduced indoor CO2 concentration. The MPC controller showed an 18.6 % energy saving compared to the DRL controller, mainly due to savings from comfort and indoor air quality boundary violations caused by unmeasured disturbances, and it also highlights computational challenges in real-time control due to non-linear optimization. Finally, we provide the practical considerations for designing and implementing the DRL and MPC controllers based on their respective pros and cons.

Guo, Fangzhou↗

Use of intrinsic hysteresis for the active control of internal transport barriers in magnetically confined fusion plasmas

In magnetically confined fusion devices, control of internal transport barriers (ITBs) is important both to enhance and suppress the turbulent transport to improve confinement control. Barrier control should allow for the improvement of confinement to aid in achieving the needed fusion criteria while also permitting the degradation of confinement to control profiles and clean the device by moving out the impurities accumulated near the core. In this work, we present a novel control scenario that takes advantage of the hysteresis intrinsic to transport barriers to easily cycle through enhanced and degraded confinement regimes. The control scenario is illustrated using a five-field simplified transport model for an ITB using typical parameters of a neutral beam injection-heated DIII-D tokamak discharge. Pellets and ion cyclotron resonance frequency power are used as control knobs for this active control scenario. These knobs adequately modify at will the local gradients and, therefore, the growth rates and shearing rates, allowing for easy and efficient control of the barrier by taking advantage of the barrier hysteresis. The result is a control cycle that could be operated with a relatively small amount of power in high performance regimes which, nowadays, typically require large power to control. It may also have advantages to avoid, or at least ameliorate, the appearance of magnetohydrodynamic instabilities in the barrier region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model-based data center cooling controls comparative co-design

This article presents a comparative simulation-based control logic design process. It uses the Control Description Language (CDL) and the ASHRAE Guideline 36 high-performing building control sequences with the Modelica Buildings Library (MBL) to demonstrate a comparative analysis of two control designs for a data center chilled water plant. Details include a description of the closed-loop plant and control design methodology, including sizing and parameterization, base and alternative (Guideline 36) control logic with software implementation structure, and outline of the simulation experimentation process. The selected control designs are paired with comparable chilled water plant configurations. The models include a chiller, a water-side economizer, and an evaporative cooling tower. The plant provides cooling at 27ºC zone supply air temperature to a data center in Sacramento, CA. The comparative simulation results examined the impacts of a selected control logic detail, and present an example model-based design application. Overall, the simulation results showed a 25% annual and a 18% summer energy use reduction for alternative controls. This shows that simulation-based control logic design performance evaluation can improve energy efficiency and resilience aspects of system controls at large.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantitative Validation of Control Bands Using Bayesian Statistical Analyses

Abstract This study presents a quantitative validation of 15 Similar Exposure Groups (SEGs) that were derived via control bands inherent to the Risk Level Based Management System currently being used at the Lawrence Livermore National Laboratory. For 93% of the SEGs that were evaluated, statistical analyses of personal exposure monitoring data, through Bayesian Decision Analysis (BDA), demonstrated that the controls implemented from the initial control bands assigned to these SEGs were at least as protective as the controls from the control band outcomes derived from the quantitative data. The BDA also demonstrated that for 40% of the SEGs, the controls from the initial control bands were overly protective, thus allowing controls to be downgraded, which resulted in a significant saving of environmental safety and health (ES&H) resources. Therefore, as a means to both confirm existing controls and to identify candidate SEGs for downgrading controls, efforts to continuously improve the accuracy of Control Banding (CB) strategies through the routine quantitative validation of SEGs are strongly encouraged. Targeted collaborative efforts across institutions and even countries for both the development of CB strategies and the validation of discreetly defined SEGs of commonly performed tasks will not only optimize limited ES&H resources but will also assist in providing a simplified process for essential risk communication at the worker level to the benefit of billions of workers around the world.

McCord, Tyler A.↗

Adaptive PID Gain Scheduling Control for Hydropower Turbine Using Neural CDE and Stochastic Distribution Shaping

This paper introduces a gain-scheduling PID controller design strategy for hydroturbine frequency control mode. This scheme first uses real data to learn the nonlinear dynamics of the hydroturbine using neural controlled differential equations and then perturbs the obtained nonlinear system at different equilibrium points, based on which a static output feedback adaptive dynamic programming algorithm is then used to optimize the PID gains for each equilibrium point. Moreover, a continuous-time version of stochastic distribution control is proposed to further fine-tune the optimized PID gains. Finally, the controller is obtained by implementing linear interpolation between the optimized PID control gains. The simulation results show that the proposed gain-scheduling PID controller can control a larger range of operation points compared with the given fixed PID controller and the baseline method. Compared with the given fixed PID controller, the proposed gain-scheduling PID controller can regulate hydroturbine frequency against disturbances induced by power-load variation with over 50% less overshoot for some operation points.

13 HYDRO ENERGY↗

Traffic Prediction for Merging Coordination Control in Mixed Traffic Scenarios

Connected and autonomous vehicles (CAVs) have the potential to bring in safety, mobility, and energy benefits to transportation. The control decisions of CAVs are usually determined for a look-ahead horizon based on previewed traffic information. This requires an effective prediction of future traffic conditions and its integration with the CAV control framework. However, the short-term traffic prediction using information from connectivity is a challenging research topic, especially for mixed traffic scenarios. This work focuses on the development of a traffic prediction framework for a merging coordination controller. The previously developed merging controller coordinates the merging sequence and travel speed of CAVs to maximize the energy efficiency and overall mobility. In mixed traffic scenarios, the controller receives information regarding the position of all the vehicles traveling inside a control zone and controls the desired speed of all CAVs. The controller has no control on the human-driven vehicles. The merging controller does not have direct information or an explicit prediction on the behaviors of human-driven vehicles. Aiming to improve the performance of the merging controller in various mixed traffic conditions, a traffic prediction algorithm is developed and evaluated in this work. The performance of this traffic prediction algorithm is investigated for various penetration rates of connectivity for a single-lane secondary road merging to a single-lane primary road. The results show that compared to a constant speed assumption of human-driven vehicles, the proposed traffic prediction algorithm is able to reduce the prediction error of the arrival time of human-driven vehicles at the merging zone by more than 50%.

Shao, Yunli↗

Fuel-Based Nash Bargaining Approach for Adaptive Signal Control in an N -Player Cooperative Game

This paper presents a fuel-based game-theoretic approach for adaptive signal control. Our controller applies Nash bargaining (NB) in an n-player cooperative game to identify optimal phasing splits considering future traffic demands. The fuel-based NB controller utilizes an objective function that combines operational measures (delays and stops) with fuel consumption measures at intersections. The proposed controller was encoded in Python and then implemented and evaluated in a VISSIM microscopic traffic simulation model in an intersection with increasing volumes. The performance of the NB controller was compared to a traditional actuated control as the baseline. The results show that the NB controller was able to achieve superior environmental gains with a 17% saving in fuel consumption and a 17% reduction in CO emissions. In addition, the proposed controller was capable of maintaining acceptable operational conditions as it achieved a 20% reduction in delay, 8% reduction in the number of stops, and 8% reduction in queue lengths compared to the actuated controller. Compared to similar studies that applied NB for adaptive signal control, our fuel-based NB controller stands out as a promising approach to significantly improve fuel consumption at signalized intersections.

Engineering↗

Optimal Control by Transfer-Learning

Through the project, a transfer-learning based optimal control methodology was developed. This can significantly reduce the time and data required for model learning and increase operation robustness and resilience via data-driven controller optimization. This methodology includes three major elements: 1) extraction of control knowledge or knowledge of tuning control parameter from a source feedback control task; 2) transferring of control knowledge from the source control task to a target control task (initialization of control parameters for the target control task); and 3) fast-adaptation of control parameters for the target task to achieve optimized performance.

42 ENGINEERING↗

Virtual synchronous generator system and method with virtual inertia control

A virtual synchronous generator device disclosed. The device includes an inverter and inverter controller having a power control portion, a power reserve portion, a power point tracking control portion, and a virtual inertia control portion. The power reserve portion determines an amount of power to be reserved and sends a signal, indicative of the determined amount of power to the power point tracking controller. The power point tracking controller determines a power point that is less than a MPP, and provides a signal to the power control portion indicative of the determined power point. The inertia control portion determines a virtual inertia and provides a signal indicative of the virtual inertia to the power control portion. The power control portion provides a power control signal to the inverter based on the power point tracking signal and the inertia command signal.

42 ENGINEERING↗

Model based co-simulation platform for integrated building system control and design optimization

Both steady-state and dynamic simulations have been widely used by HVAC&R industry to support product/equipment development for decades. Steady-state simulation focuses on the system mass, energy and momentum balance of an equilibrium state. It is based on high-fidelity components models, and thus is suitable for system and component design optimization. Dynamic simulation studies the system transient response and is generally used for controls development and verification. It usually does not require rigorous component models of high accuracy because 1) the commonly used PID control is feedback control whose control performance evaluation doesn’t require high fidelity system/plant model; 2) high-fidelity dynamic model significantly increases the number of equations and variables and creates tremendous challenge for math solver. For supervisory control, transactive control or optimization of an integrated building system, the HVAC&R equipment is often one of the sub-components to be controlled. High-fidelity equipment models are required for accurately evaluating control strategies. In addition, building equipment manufacturers have developed a lot of high-fidelity steady-state equipment/component models per their expertise. Thus, a platform that can integrate OEM high-fidelity steady-state model with dynamic building simulation and/or electric power system & grid simulation to support the development and verification of supervisory control for integrated building systems is necessary. In this study, ORNL’s heat pump design tool (HPDM) is utilized to develop a co-simulation platform for supervisory control and optimization in integrated building systems. It is based on a model that integrates high-fidelity steady-state simulation equipment models with dynamic building simulation. A practical case of using the proposed co-simulation platform to develop and evaluate the supervisory control and optimization is presented and discussed.

Sun, Jian↗

Supervisory genset control in range-extended electric vehicle

A controls system for a range-extended electric vehicle comprising an overall system control unit, an engine control module configured to control a range extender of the range-extended electric vehicle, power electronics configured to control a generator of the range-extended electric vehicle, and a supervisory control module coupled between the overall system control unit and the engine control module and the power electronics, the supervisory control module configured to receive information from the overall system control unit and provide commands to the engine control module and the power electronics.

Li, Ke↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Carbon emission responsive building control: A case study with an all-electric residential community in a cold climate

In the United States, buildings account for 35% of total energy-related carbon dioxide emissions, making them important contributors to decarbonization. Carbon intensities in the power grid are time-varying and can fluctuate significantly within hours, so shifting building loads in response to the carbon intensities can reduce a building’s operational carbon emissions. This paper presents a rule-based carbon responsive control framework that controls the setpoints of thermostatically controlled loads responding to the grid’s carbon emission signals in real time. Based on this framework, four controllers are proposed with different combinations of carbon accounting methods and control rules. To evaluate their performance, we performed simulation studies using models of a 27-home, all-electric, net zero energy residential community located in Basalt, Colorado, United States. The carbon intensity data of four future years from the Cambium data set are adopted to account for the evolving resource mix in the power grid. Various performance metrics, including energy consumption, carbon emission, energy cost, and thermal discomfort, were used to evaluate the performance of the controllers. Sensitivity analysis was also conducted to determine how the control thresholds and intervals affect the controllers’ performance. Simulation results indicate that the carbon responsive controllers can reduce the homes’ annual carbon emissions by 6.0% to 20.5%. However, the energy consumption increased by 0.9% to 6.7%, except in one scenario where it decreased by 2.2%. Compared to the baseline, the change in energy cost was between –2.9% and 3.4%, and thermal discomfort was also maintained within an acceptable range. The little impact on energy cost and thermal discomfort indicates there are no potential roadblocks for customer acceptance when rolling out the controllers in utility programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Framework for assessment of magnetic equilibrium controller performance on the MAST upgrade spherical tokamak

Here, in this work we present the assessment framework for magnetic equilibrium controllers on MAST Upgrade spherical tokamak (MAST-U) spherical tokamak. Such controllers are essential for the MAST-U since exhaust physics and core-edge integration studies require advanced divertor plasma configurations. The developed framework is based on the TokSys suite of plasma control codes, which was adapted and upgraded for MAST-U. However, extra capabilities were added on top of TokSys to support the development of new control algorithms, deployment of controllers to the plasma control system (PCS) and evaluation of their performance. The controller assessment was realized via closed-loop integrated control simulations with the actual MAST-U PCS and different physics-based plasma models. Since all components of the assessment chain were experimentally validated, these simulations provide qualified controllers applicable for direct use in the experiment. This resulted in the successful experimental demonstration of advanced plasma shape control on MAST-U with minimal on-machine development time. A similar methodology would be beneficial to other tokamaks, both existing and future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗

Enhanced Control, Optimization, and Integration of Distributed Energy Applications (ECO-IDEA)

With support from the U.S. Department of Energy Solar Energy Technologies Office, the National Renewable Energy Laboratory (NREL) partnered with Xcel Energy, Schneider Electric, Varentec, and Electric Power Research Institute (EPRI) to meet the goals of the Enabling Extreme Real-Time Grid Integration of Solar Energy (ENERGISE) program. This project developed and validated an innovative data-enhanced hierarchical control architecture that enables the efficient, reliable, resilient, and secure operation of future distribution systems with a high penetration of distributed energy resources like solar energy. The architecture enables a hybrid control approach where a centralized control layer is complemented by distributed control algorithms for solar inverters and autonomous control of grid edge devices. It is fully interoperable and includes all the cybersecurity aspects necessary for reliable and secure system operation. The hybrid approach can seamlessly integrate multiple voltage-regulation technologies, both at central and grid-edge levels, which enables reliable and efficient system operation in the face of unpredictable conditions. The overarching goal of the Eco-Idea project is to develop, validate, and deploy a unique and innovative Data-Enhanced Hierarchical Control (DEHC) architecture that comprehensively addresses the formidable challenges associated with proliferation of high penetration of distributed PV such as reverse power flows, transients from variability of PV systems, feeder load balancing, and voltage stability. These issues are exposing the weaknesses of existing grid operations and controls - including, but not limited to, lack of grid situational awareness, heuristic and slow-acting control actions, latency of control for emergency situations, and points of failure in communications. The proposed architecture will comprehensively resolve the deficiencies of current operational settings - where monitoring and control solutions proposed across industry and academia may not be interoperable and may not coexist in the same system - and will enable an efficient, reliable, resilient, and secure operation of future distribution systems with penetration of solar energy well beyond current limits. The DEHC architecture was developed and validated rigorously through hardware-in-loop simulations in the laboratory environment and deployed on the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Human-in-the-loop Sensing and Control for Commercial Building Energy Efficiency and Occupant Comfort

Most of the existing heating, ventilation and air conditioning (HVAC) systems in commercial buildings operate in a conservative manner by assuming maximum occupancy in each room during pre-specified periods of the week, leading to significant energy being wasted as rooms are over-conditioned compared to the actual requirements of the occupants. Though critical, our understanding of occupancy patterns and thermal comfort needs of the occupants in commercial buildings is lacking and it is well known that both of these quantities are stochastic and time-varying, thus requiring sensing solutions to estimate them. This project had the goal of designing, implementing and evaluating a hardware and software solution to ameliorate this challenge. In particular, a depth camera (one whose pixels reveal distance from the camera as opposed to color values) placed on doorways is used to detect entrance and exit events from thermal zones in the building, and thereby estimate their occupancy levels. This information is then fed to a novel control algorithm that can, through interactions with the HVAC system, learn how to provide control inputs that maximize comfort and minimize energy waste. The resulting system represents a significant improvement over existing controllers for commercial HVAC systems and allowed us to improve our understanding of the design of future human-in-the-loop control solutions. For this solution to be feasible, the project had target metrics for its performance and cost. In particular, entrance and exit events for occupants moving about the building would need to be detected with an accuracy higher than 97%; and the resulting control inputs derived from this information would need to lead to approximately 10% energy savings compared to a schedule-based controller. Furthermore, regarding the final hardware design, the project had a target bill of materials (BOM) cost for the sensing solution of less than US$200 per unit while using less than 25W of power on average. All of these target metrics were met or exceeded by our final proposed solution. We performed evaluations by deploying the system in over 20 rooms of different types across 6 commercial buildings in Pittsburgh, PA over the course of three years, and performing targeted controlled experiments to test its performance along the different metrics. The human-in-the-loop control solutions (both hardware and software) developed through this project are expected to lead to significant improvements in the comfort and energy efficiency of HVAC systems used in commercial buildings. The insights we developed through the project pave the way to HVAC systems that can condition interior spaces according to their real-time utilization and the thermal comfort needs of the occupants, thereby reducing energy use. They also open up a new learning-based way of configuring HVAC controllers without having to manually fine-tune them for each building. These innovations can significantly increase the adoption of novel control solutions by the industry and thereby save resources and reduce costs of operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A practical approach to determine minimal quantum gate durations using amplitude-bounded quantum controls

Here, we present an iterative scheme to estimate the minimal duration in which a quantum gate can be realized while satisfying hardware constraints on the control pulse amplitudes. The scheme performs a sequence of unconstrained numerical optimal control cycles that each minimize the gate fidelity for a given gate duration alongside an additional penalty term for the control pulse amplitudes. After each cycle, the gate duration is adjusted based on the inverse of the resulting maximum control pulse amplitudes by re-scaling the dynamics to a new duration where control pulses satisfy the amplitude constraints. Those scaled controls then serve as an initial guess for the next unconstrained optimal control cycle, using the adjusted gate duration. We provide multiple numerical examples that each demonstrate fast convergence of the scheme toward a gate duration that is close to the quantum speed limit, given the control pulse amplitude bound. The proposed technique is agnostic to the underlying system and control Hamiltonian models, as well as the target unitary gate operation, making the time-scaling iteration an easy to implement and practically useful scheme for reducing the durations of quantum gate operations.

97 MATHEMATICS AND COMPUTING↗