Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Surface film effects on drop tube undercooling studies

The effects of various gaseous atmospheric constituents on drop-tube solidified samples of elemental metals were examined from a microstructural standpoint. All specimens were prepared from the purest available elements, so effects of impurities should not account for the observed effects. The drop-tube gas has a definite effect on the sample microstructure. Most dramatically, the sample cooling rate is effected. Some samples receive sufficient cooling to solidify in free fall while others do not, splating at the end of the drop tube in the sample catcher. Gases are selectively absorbed into the sample. Upon solidification gas can become less soluble and as a result forms voids within the sample. The general oxidation/reduction characteristics of the gas also affect sample microstructures. In general, under the more favorable experimental conditions including reducing atmospheric conditions and superheatings, examination of sample microstructures indicates that nucleation has been suppressed. This is indicated by underlying uniform dendrite spacings throughout the sample and with a single dendrite orientation through most of the sample. The samples were annealed yielding a few large grains and single or bi-crystal samples were commonly formed. This was especially true of samples that were inadvertently greatly superheated. This is in contrast with results from a previous study in which surface oxides were stable and contained numerous sites of nucleation. The number of nucleation events depends upon the surface state of the specimen as determined by the atmosphere and is consistent with theoretical expectations based upon the thermodynamic stability of surface oxide films. Oxide-free specimens are characterized by shiny surfaces, with no observable features under the scanning electron microscope at 5000X.

Ethridge, E. C.↗

Non-isothermal laminar flow of gases through cooled tubes.

Numerical solutions of the laminar-flow equations in differential form are presented for gas flows through cooled tubes. For nearly isothermal flow there is good agreement with available experimental data, as is also found for the case of a large amount of wall cooling. This correspondence along with a check on the satisfaction of the global momentum and energy constraints allowed an appraisal of the effect of wall cooling on flow through tubes. In general, the effect of wall cooling was to decrease the wall friction and the change in pressure along tubes, but the average heat-transfer coefficient did not vary much.

Back, L. H.↗

Radiative forcing of climate by changes in the vertical distribution of ozone

Results from a one-dimensional radiative-convective equilibrium model (similar to that of Lacis et al., 1981) of surface-temperature changes induced by changes in the vertical distribution of O3 in the atmosphere are parameterized and applied to measurement data for the northern midlatitudes during the 1970s. The construction of the model is outlined, and the results are presented in tables and graphs and discussed in detail. It is found that decreases in O3 in the lower stratosphere in the 1970s caused atmospheric cooling greater than that due to CO2 (thus possibly obscuring the CO2 greenhouse effect) and surface cooling which outweighed the warming effect of increased O3 in the troposphere. The net surface cooling is shown to be equal to about half of the estimated CO2 warming effect for the period.

Lacis, Andrew A.↗

Similarity constraints in testing of cooled engine parts

A study is made of the effect of testing cooled parts of current and advanced gas turbine engines at the reduced temperature and pressure conditions which maintain similarity with the engine environment. Some of the problems facing the experimentalist in evaluating heat transfer and aerodynamic performance when hardware is tested at conditions other than the actual engine environment are considered. Low temperature and pressure test environments can simulate the performance of actual size prototype engine hardware within the tolerance of experimental accuracy if appropriate similarity conditions are satisfied. Failure to adhere to these similarity constraints because of test facility limitations or other reasons, can result in a number of serious errors in projecting the performance of test hardware to engine conditions.

Colladay, R. S.↗

On the stabilization of three-dimensional boundary layers by suction and cooling

A significant reduction in the drag of transonic aircraft can be achieved by using an active method of boundary-layer control to maintain laminar flow on the aerodynamic surfaces. The stabilizing influence of suction for both favorable and adverse pressure gradients is demonstrated by means of the self-similar incompressible three-dimensional boundary layers on yawed wedges. Profile instability is measured by the maximum amplification rate of fixed-frequency disturbances computed according to linearized, locally parallel, spatial stability theory. Suction is found to be more effective in controlling Tollmien-Schlichting instability than stationary cross-flow disturbances. The effectiveness of surface cooling as a method of stabilization is compared with suction for the boundary layers on a transonic 35 deg swept wing of infinite span. It is found from compressible stability theory that when the surface is cooled to a uniform temperature such that the maximum cross-flow velocity is reduced by the same amount as with a uniform suction distribution, the stabilizing effect of cooling on cross-flow disturbances is less than with suction.

Mack, L. M.↗

Shock/shock interference on a transpiration cooled hemispherical model

Experimental results are presented which show the effectiveness of transpiration cooling in reducing the peak heat flux caused by an impinging shock on a bow shock of a hemispherical model. The 12-inch diameter hemispherical transpiration model with helium coolant was tested in the Calspan 48-inch Hypersonic Shock Tunnel at nominal Mach 12.1 and freestream unit Reynolds number of 0.33 x 10 to the 6th/ft. An incident shock wave, generated by a blunt flat-plate shock generator inclined at 10 deg to the freestream, intersected the bow shock of the model to produce shock/shock interference. The stagnation heat flux without coolant or shock/shock interference was about 1.6 times a smooth surface laminar prediction due to effective roughness of the coolant ejection slots. A coolant mass flux 31 percent of the freestream mass flux reduced the stagnation heat flux to zero without shock/shock interference. However, for the same coolant mass flux and with shock/shock interference the peak heat flux was only reduced 8.3 percent, even though the total integrated heat load was reduced.

Nowak, Robert J.↗

Instability of compressible boundary layers along curved walls with suction or cooling

This paper investigates the effect of suction of the boundary layer and wall cooling on the growth and development of three-dimensional longitudinal vortices over concave walls. The study is carried out for compressible flows for a range of Mach numbers from 0 to 5. Despite indications that small suction or small cooling rates locally reduce the critical Goertler number (destabilize the boundary layer), the overall effect of suction or cooling is to stabilize the boundary layer by reducing the amplitude ratio of the vortices. In case of suction, this becomes more difficult with increasing Mach number unless high suction rates are used. On the other hand, stabilizing the boundary layer with respect to Goertler vortices can hardly be achieved by cooling even when high cooling rates are used.

El-Hady, N. M.↗

Transient Three-Dimensional Startup Side Load Analysis of a Regeneratively Cooled Nozzle

The objective of this effort is to develop a computational methodology to capture the startup side load physics and to anchor the computed aerodynamic side loads with the available data from a regeneratively cooled, high-aspect-ratio nozzle, hot-fired at sea level. The computational methodology is based on an unstructured-grid, pressure-based, reacting flow computational fluid dynamics and heat transfer formulation, a transient 5 s inlet history based on an engine system simulation, and a wall temperature distribution to reflect the effect of regenerative cooling. To understand the effect of regenerative wall cooling, two transient computations were performed using the boundary conditions of adiabatic and cooled walls, respectively. The results show that three types of shock evolution are responsible for side loads: generation of combustion wave; transitions among free-shock separation, restricted-shock separation, and simultaneous free-shock and restricted shock separations; along with the pulsation of shocks across the lip, although the combustion wave is commonly eliminated with the sparklers during actual test. The test measured two side load events: a secondary and lower side load, followed by a primary and peak side load. Results from both wall boundary conditions captured the free-shock separation to restricted-shock separation transition with computed side loads matching the measured secondary side load. For the primary side load, the cooled wall transient produced restricted-shock pulsation across the nozzle lip with peak side load matching that of the test, while the adiabatic wall transient captured shock transitions and free-shock pulsation across the lip with computed peak side load 50% lower than that of the measurement. The computed dominant pulsation frequency of the cooled wall nozzle agrees with that of a separate test, while that of the adiabatic wall nozzle is more than 50% lower than that of the measurement. The computed teepee-like formation and the tangential motion of the shocks during lip pulsation also qualitatively agree with those of test observations. Moreover, a third transient computation was performed with a proportionately shortened 1 s sequence, and lower side loads were obtained with the higher ramp rate.

Wang, Ten-See↗

Two-dimensional cold-air cascade study of a film-cooled turbine stator blade. 1: Experimental results of pressure-surface film cooling tests

The effect of film coolant ejection from the pressure side of a stator blade was determined in a two-dimensional cascade. Stator exit surveys were made for each of six rows of coolant holes. Successive multirow tests were made with two, three, four, five, and six rows of coolant holes open. The results of the multirow tests are compared with the predicted multirow performance obtained by adding the single-row data. Results are presented in terms of stator primary-air efficiency as a function of coolant fraction.

Moffitt, T. P.↗

Small gas turbine combustor study: Fuel injector performance in a transpiration-cooled liner

The effect of fuel injection technique on the performance of an advanced reverse flow combustor liner constructed of Lamilloy (a multilaminate transpiration type material) was determined. Performance and emission levels are documented over a range of simulated flight conditions using simplex pressure atomizing, spill return, and splash cone airblast injectors. A parametric evaluation of the effect of increased combustor loading with each of the fuel injector types is obtained.

Riddlebaugh, S. M.↗

Small gas turbine combustor study - Fuel injector performance in a transpiration-cooled liner

The effect of fuel injection technique on the performance of an advanced reverse flow combustor liner constructed of Lamilloy (a multilaminate transpiration type material) was determined. Performance and emission levels are documented over a range of simulated flight conditions using simplex pressure atomizing, spill return, and splash cone airblast injectors. A parametric evaluation of the effect of increased combustor loading with each of the fuel injector types is obtained.

Riddlebaugh, S. M.↗

Stirling-Cycle Cooling For Tunable Diode Laser

Miniature Stirling-cycle cooler effective in continously cooling PbSnTe tunable diode laser to stable operating temperature near 80 K. Simplifies laboratory diode-laser spectroscopy and instruments for use aboard aircraft and balloons.

Durso, Santo S.↗

Optimizing a Coupled Solution for the Orion MPCV Using DPLR and NEQAIR

The goal of this project is to study the convective and radiative heat flux predictions using computational fluid dynamics (CFD) on a smooth body representation of the NASA Orion Multi-Purpose Crew Vehicle (MPCV). The Orion MPCV is designed for long duration missions in space and will play a crucial role in transporting astronauts in the upcoming Artemis missions. With Orion's aim for cost-effective reusability comes a need to study its Thermal Protection System (TPS), which allows for safe entry into the atmospheres of the Earth, Moon, and Mars. In order to study the effects of the TPS on test flights and better understand the aerothermal environment, CFD is a necessary tool used to create simulations of entry vehicles and calculate the heat load and heat flux. However, solutions are often performed using an uncoupled approach between the flow and the radiation solver. This leads to an overestimation of the overall heating effects because they do not consider radiative cooling. Furthermore, the effects of radiation on the aft-body is an area of research with significant uncertainty. Through the use of codes developed at NASA Ames, DPLR and NEQAIR, a coupled solution can be attained for the Orion capsule which will more accurately solve for the effects of radiation in both the fore and aft-body regions. This yields more accurate design margins for the TPS, which produces a better estimate of the thickness required. By developing an accurate coupled solution of the TPS on the Orion MPCV, planners will have greater flexibility in carrying out future missions to the Moon and beyond.

Design↗

High-Altitude Flight Cooling Investigation of a Radial Air-Cooled Engine

An investigation of the cooling of an 18-cylinder, twin-row, radial, air-cooled engine in a high-performance pursuit airplane has been conducted for variable engine and flight conditions at altitudes ranging from 5000 to 35,000 feet in order to provide a basis for predicting high-altitude cooling performance from sea-level or low altitude experimental results. The engine cooling data obtained were analyzed by the usual NACA cooling-correlation method wherein cylinder-head and cylinder-barrel temperatures are related to the pertinent engine and cooling-air variables. A theoretical analysis was made of the effect on engine cooling of the change of density of the cooling air across the engine (the compressibility effect), which becomes of increasing importance as altitude is increased. Good agreement was obtained between the results of the theoretical analysis and the experimental data.

Manganiello, Eugene J↗

Cooling of pulsars.

The effects of the magnetic field and superfluidity on the cooling of neutron stars during the stage when they can be observed as pulsars are considered. A neutron-star model with a stellar mass of 1.07 solar mass, a radius of 12.33 km, and a central energy density of 7.39 x 10 to the 14th power gauss/cu cm was chosen. It appears that during the earlier periods while the star cools by neutrino emission, surface temperatures are somewhat higher at a given age in the presence of stronger magnetic fields. An interesting result is that most pulsars may be very cold.

Tsuruta, S.↗

Hot streaks and phantom cooling in a turbine rotor passage. II - Combined effects and analytical modelling

Experimental documentation and analytical correlations demonstrating the effects of hot streak accumulation and phantom cooling on turbine rotor airfoil surface temperature are presented. Results are shown which quantify the impact of a nonuniform temperature profile at the entrance of a turbine due to combustor-generated hot and cold streaks, and cooling air discharged from the trailing edge of the upstream stator. Experimental results are shown for a range of controlling variables to identify where streak accumulation and phantom cooling were most likely to be strongest. These variables include streak-to-free stream density ratio, streak injection location, and coolant-to-free stream density and velocity ratios. Experimental results are shown for the combined effects of hot streak and stator coolant on the adiabatic recovery temperature of the rotor.

Roback, Richard J.↗

Effects of film injection on performance of a cooled turbine

Some of the most dramatic increases in the performance of turbojet and turbofan aircraft engines have been obtained as a result of increased thermodynamic cycle temperatures made possible by the use of film cooling techniques. The realization of the potential performance gains, however, is only possible if the quantity of cooling air and the aerodynamic mixing losses resulting from the injection of coolant in the form of film on the flowpath surfaces are minimized. Such a minimization requires a more complete understanding of the relationship between cooling and aerodynamics. A review is conducted of tests which have been conducted to determine the effects of coolant injection on turbine performance. The results obtained in the tests are compared with an analytical technique developed for predicting coolant injection effects. Particular attention is given to the effects of turbine cooling on overall cycle thermodynamic efficiency, taking into account incremental changes in turbine thermodynamic efficiency for various incremental changes in coolant flow rate.

Mcdonel, J. D.↗

The effects of leading edge and downstream film cooling on turbine vane heat transfer

The progress under contract NAS3-24619 toward the goal of establishing a relevant data base for use in improving the predictive design capabilities for external heat transfer to turbine vanes, including the effect of downstream film cooling with and without leading edge showerhead film cooling. Experimental measurements were made in a two-dimensional cascade previously used to obtain vane surface heat transfer distributions on nonfilm cooled airfoils under contract NAS3-22761 and leading edge showerhead film cooled airfoils under contract NAS3-23695. The principal independent parameters (Mach number, Reynolds number, turbulence, wall-to-gas temperature ratio, coolant-to-gas temperature ratio, and coolant-to-gas pressure ratio) were maintained over ranges consistent with actual engine conditions and the test matrix was structured to provide an assessment of the independent influence of parameters of interest, namely, exit Mach number, exit Reynolds number, coolant-to-gas temperature ratio, and coolant-to-gas pressure ratio. Data provide a data base for downstream film cooled turbine vanes and extends the data bases generated in the two previous studies. The vane external heat transfer obtained indicate that considerable cooling benefits can be achieved by utilizing downstream film cooling. The data obtained and presented illustrate the interaction of the variables and should provide the airfoil designer and computational analyst the information required to improve heat transfer design capabilities for film cooled turbine airfoils.

Hylton, L. D.↗