Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Completion Report for Model Evaluation Well ER-5-5: Corrective Action Unit 98: Frenchman Flat

Model Evaluation Well ER-5-5 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of Nevada Environmental Management Operations at the Nevada National Security Site (formerly known as the Nevada Test Site). The well was drilled in July and August 2012 as part of a model evaluation well program in the Frenchman Flat area of Nye County, Nevada. The primary purpose of the well was to provide detailed geologic, hydrogeologic, chemical, and radiological data that can be used to test and build confidence in the applicability of the Frenchman Flat Corrective Action Unit flow and transport models for their intended purpose. In particular, this well was designed to obtain data to evaluate the uncertainty in model forecasts of contaminant migration from the upgradient underground nuclear test MILK SHAKE, conducted in Emplacement Hole U-5k in 1968, which were considered to be uncertain due to the unknown extent of a basalt lava-flow aquifer present in this area. Well ER-5-5 is expected to provide information to refine the Phase II Frenchman Flat hydrostratigraphic framework model, if necessary, as well as to support future groundwater flow and transport modeling. The 31.1-centimeter (cm) diameter hole was drilled to a total depth of 331.3 meters (m). The completion string, set at the depth of 317.2 m, consists of 16.8-cm stainless-steel casing hanging from 19.4-cm carbon-steel casing. The 16.8-cm stainless-steel casing has one slotted interval open to the basalt lava-flow aquifer and limited intervals of the overlying and underlying alluvial aquifer. A piezometer string was also installed in the annulus between the completion string and the borehole wall. The piezometer is composed of 7.3-cm stainless-steel tubing suspended from 6.0-cm carbon-steel tubing. The piezometer string was landed at 319.2 m, to monitor the basalt lava-flow aquifer. Data collected during and shortly after hole construction include composite drill cuttings samples collected every 3.0 m, various geophysical logs, preliminary water quality measurements, and water-level measurements. The well penetrated 331.3 m of Quaternary–Tertiary alluvium, including an intercalated layer of saturated basalt lava rubble. No well development or hydrologic testing was conducted in this well immediately after completion; however, a preliminary water level was measured in the piezometer string at the depth of 283.4 m on September 25, 2012. No tritium above the minimum detection limit of the field instruments was detected in this hole. Future well development, sampling, and hydrologic testing planned for this well will provide more accurate hydrologic information for this site. The stratigraphy, general lithology, and water level were as expected, though the expected basalt lava-flow aquifer is basalt rubble and not the dense, fractured lava as modeled. The lack of tritium transport is likely due to the difference in hydraulic properties of the basalt lava-flow rubble encountered in the well, compared to those of the fractured aquifer used in the flow and transport models.

58 GEOSCIENCES↗

Electrochemical assay of active prostate-specific antigen (PSA) using ferrocene-functionalized peptide probes

This paper presents a novel approach to electrochemically determine enzymatically active PSA using ferrocene-functionalized helix peptide (CHSSLKQK). The principle of electrochemical measurement is based on the specific proteolytic cleavage events of the FC-peptide on the gold electrode surface in the presence of PSA, resulting the change of the current signal of the electrode. The percentage of the decreased current is linear with the concentration of active PSA at the range of 0.5-40 ng/mL with a detection limit of 0.2 ng/mL. The direct transduction of peptide cleavage events into an electrical signal provides a simple, sensitive method for detecting the enzymatic activity of PSA and determining the active PSA concentration.

60 APPLIED LIFE SCIENCES↗

Isotopic analysis of Nd nanoparticles using single particle MC-ICP-MS: A comparative study with single particle-ICP-TOF-MS

Single particle - inductively coupled plasma - mass spectrometry (SP-ICP-MS) is a powerful technique for characterization of the elemental and isotopic composition of individual particles. In this work, the capabilities of the newest generation of MC-ICP-MS with acquisition rates down to 50 ms were evaluated for single particle analysis, with a focus on isotopic precision achievable on a single-particle level. Nd (NdVO 4 ) nanoparticles (~120 nm in diameter) were used as case study and were first characterized in terms of mass (respective size) and particle number concentration by SP-ICP-TOF-MS and then by SP-MC-ICP-MS for isotopic precision. For the isotopic ratio measurements, the MC-ICP-MS performance was compared to the ICP-TOF-MS and it was found that the isotope ratio precision was increased (R 2 between 0.98 and 0.99) compared to ICP-TOF-MS (R 2 between 0.88 and 0.97). The accuracy attained on a single particle level, was compared to bulk digestion followed by MC-ICP-MS analysis, and the SP-MC-ICP-MS technique was able to determine the particle population average to be <4 %, percent relative differences for the 142 Nd/ 144 Nd, 143 Nd/ 144 Nd, 145 Nd/ 144 Nd, 146 Nd/ 144 Nd, and 148 Nd/ 144 Nd ratios The detection limit for the SP-MC-ICP-MS approach was also assessed. Here, when utilizing an all Faraday-cup based detection scheme the determined LOD for the measurements was 0.2fg for Nd, per particle. Based on these results, the newest generation of MC-ICP-MS has demonstrated its utility for performing SP measurement, particularly when high precision isotopic determination is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ag films grown by remote plasma enhanced atomic layer deposition on different substrates

Silver (Ag) layers were deposited by remote plasma enhanced atomic layer deposition (PALD) using Ag(fod)(PEt{sub 3}) (fod = 2,2-dimethyl-6,6,7,7,8,8,8-heptafluorooctane-3,5-dionato) as precursor and hydrogen plasma on silicon substrate covered with thin films of SiO{sub 2}, TiN, Ti/TiN, Co, Ni, and W at different deposition temperatures from 70 to 200 °C. The deposited silver films were analyzed by x-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), scanning electron microscopy (SEM), transmission electron microscopy (TEM) with energy dispersive x-ray spectroscopy, four point probe measurement, ellipsometric measurement, x-ray fluorescence (XRF), and x-ray diffraction (XRD). XPS revealed pure Ag with carbon and oxygen contamination close to the detection limit after 30 s argon sputtering for depositions made at 120 and 200 °C substrate temperatures. However, an oxygen contamination was detected in the Ag film deposited at 70 °C after 12 s argon sputtering. A resistivity of 5.7 × 10{sup −6} Ω cm was obtained for approximately 97 nm Ag film on SiO{sub 2}/Si substrate. The thickness was determined from the SEM cross section on the SiO{sub 2}/Si substrate and also compared with XRF measurements. Polycrystalline cubic Ag reflections were identified from XRD for PALD Ag films deposited at 120 and 200 °C. Compared to W surface, where poor adhesion of the films was found, Co, Ni, TiN, Ti/TiN and SiO{sub 2} surfaces had better adhesion for silver films as revealed by SEM, TEM, and AFM images.

36 MATERIALS SCIENCE↗

Saturn's ionosphere: Inferred electron densities

During the two Voyager encounters with Saturn, radio bursts were detected which appear to have originated from atmospheric lightning storms. Although these bursts generally extended over frequencies from as low as 100 kHz to the upper detection limit of the instrument, 40 MHz, they often exhibited a sharp but variable low frequency cutoff below which bursts were not detected. We interpret the variable low-frequency extent of these bursts to be due to the reflection of the radio waves as they propagate through an ionosphere which varies with local time. We obtain estimates of electron densities at a variety of latitude and local time locations. These compare well with the dawn and dusk densitis measured by the Pioneer 11 Voyager Radio Science investigations, and with model predictions for dayside densities. However, we infer a two-order-of-magnitude diurnal variation of electron density, which had not been anticipated by theoretical models of Saturn's ionosphere, and an equally dramatic extinction of ionospheric electron density by Saturn's rings.

Kaiser, M. L.↗

Saturn's ionosphere - Inferred electron densities

During the two Voyager encounters with Saturn, radio bursts were detected which appear to have originated from atmospheric lightning storms. Although these bursts generally extended over frequencies from as low as 100 kHz to the upper detection limit of the instrument, 40 MHz, they often exhibited a sharp but variable low frequency cutoff below which bursts were not detected. We interpret the variable low-frequency extent of these bursts to be due to the reflection of the radio waves as they propagate through an ionosphere which varies with local time. We obtain estimates of electron densities at a variety of latitude and local time locations. These compare well with the dawn and dusk densities measured by the Pioneer 11 Voyager Radio Science investigations, and with model predictions for dayside densities. However, we infer a two-order-of-magnitude diurnal variation of electron density, which had not been anticipated by theoretical models of Saturn's ionosphere, and an equally dramatic extinction of ionospheric electron density by Saturn's rings. Previously announced in STAR as N84-17102

Kaiser, M. L.↗

The enigmatic jets of NGC 1097

We use deep optical images, spectroscopy, and radio observations of the optical jets in NGC 1097 to constrain models for their origin. Our detection limit on 20-cm radio emission from the region of the optical jets is ten times fainter than previous results. We detect no steep-spectrum emission at 90-cm associated with fossil radio lobes. If star formation in the optical jets was triggered by ejection of relativistic matter from an active nucleus, the time of activity was at least 10 million years ago.

Wehrle, Ann E.↗

Searching for Faint Companions to Nearby Stars with the Hubble Space Telescope

A search for faint companions (FC's) to selected stars within 5 pc of the Sun using the Hubble Space Telescope's Planetary Camera (PC) has been initiated. To assess the PC's ability to detect FCs, we have constructed both model and laboratory-simulated images and compared them to actual PC images. We find that the PC's point-spread function (PSF) is 3-4 times brighter over the angular range 2-5 sec than the PSF expected for a perfect optical system. Azimuthal variations of the PC's PSF are 10-20 times larger than expected for a perfect PSF. These variations suggest that light is scattered nonuniformly from the surface of the detector. Because the anomalies in the PC's PSF cannot be precisely simulated, subtracting a reference PSF from the PC image is problematic. We have developed a computer algorithm that identifies local brightness anomalies within the PSF as potential FCs. We find that this search algorithm will successfully locate FCs anywhere within the circumstellar field provided that the average pixel signal from the FC is at least 10 sigma above the local background. This detection limit suggests that a comprehensive search for extrasolar Jovian planets with the PC is impractical. However, the PC is useful for detecting other types of substellar objects. With a stellar signal of 10(exp 9) e(-), for example, we may detect brown dwarfs as faint as M(sub I) = 16.7 separated by 1 sec from alpha Cen A.

Schroeder, Daniel J.↗

Sensitive Procedures for Determining the Permeation Resistance of Chlorinated Polyethylene Against Liquid Propellants

The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.

Waller, Jess M.↗

The Infrared-Optical Telescope (IRT) of the Exist Observatory

The IRT is a 1.1m visible and infrared passively cooled telescope, which can locate, identify and obtain spectra of GRB afterglows at redshifts up to z 20. It will also acquire optical-IR, imaging and spectroscopy of AGN and transients discovered by the EXIST (The Energetic X-ray Imaging Survey Telescope). The IRT imaging and spectroscopic capabilities cover a broad spectral range from 0.32.2m in four bands. The identical fields of view in the four instrument bands are each split in three subfields: imaging, objective prism slitless for the field and objective prism single object slit low resolution spectroscopy, and high resolution long slit on single object. This allows the instrument, to do simultaneous broadband photometry or spectroscopy of the same object over the full spectral range, thus greatly improving the efficiency of the observatory and its detection limits. A prompt follow up (within three minutes) of the transient discovered by the EXIST makes IRT a unique tool for detection and study of these events, which is particularly valuable at wavelengths unavailable to the ground based observatories.

Kutyrev, Alexander↗

2014 ISS Potable Water Characterization and Continuation of the Dimethylsilanediol Chronicle

During 2014 the crews from Expeditions 38-41 were in residence on the International Space Station (ISS). In addition to the U.S. potable water reclaimed from humidity condensate and urine, the other water supplies available for their use were Russian potable water reclaimed from condensate and Russian ground-supplied potable water. Beginning in June of 2014 and for the fourth time since 2010, the product water from the U.S. water processor assembly (WPA) experienced a rise in the total organic carbon (TOC) level due to organic contaminants breaking through the water treatment process. Results from ground analyses of ISS archival water samples returned on Soyuz 38 confirmed that dimethylsilanediol was once again the contaminant responsible for the rise. With this confirmation in hand and based upon the low toxicity of dimethylsilanediol, a waiver was approved to allow the crew to continue to consume the water after the TOC level exceeded the U.S. Segment limit of 3 mg/L. Several weeks after the WPA multifiltration beds were replaced, the TOC levels returned to below the method detection limit of the onboard TOC analyzer (TOCA) as anticipated based upon experience from previous rises. This paper presents and discusses the chemical analysis results for the ISS archival potable-water samples returned in 2014 and analyzed by the Johnson Space Center's Toxicology and Environmental Chemistry laboratory. These results showed compliance with ISS potable water quality standards and indicated that the potable-water supplies were acceptable for crew consumption. Although dimethylsilanediol levels were at times elevated, they remained well below the 35 mg/L health limit so the continued consumption of the U.S. potable water was considered a low risk to crew health and safety. Excellent agreement between in-flight and archival sample TOC data confirmed that the TOCA performed optimally and continued to serve as a vital tool for monitoring organic breakthrough and planning remediation action.

Straub, John E., II↗

The Atacama Cosmology Telescope: A Search for Planet 9

We use Atacama Cosmology Telescope (ACT) observations at 98 GHz (2015–2019), 150 GHz (2013–2019), and 229 GHz (2017–2019) to perform a blind shift-and-stack search for Planet 9. The search explores distances from 300 au to 2000 au and velocities up to 6farcm3 per year, depending on the distance (r). For a 5 Earth-mass Planet 9 the detection limit varies from 325 au to 625 au, depending on the sky location. For a 10 Earth-mass planet the corresponding range is 425 au to 775 au. The predicted aphelion and most likely location of the planet corresponds to the shallower end of these ranges. The search covers the whole 18,000 square degrees of the ACT survey. No significant detections are found, which is used to place limits on the millimeter-wave flux density of Planet 9 over much of its orbit. Overall we eliminate roughly 17% and 9% of the parameter space for a 5 and 10 Earth-mass Planet 9, respectively. These bounds approach those of a recent INPOP19a ephemeris-based analysis, but do not exceed it. We also provide a list of the 10 strongest candidates from the search for possible follow-up. More generally, we exclude (at 95% confidence) the presence of an unknown solar system object within our survey area brighter than 4–12 mJy (depending on position) at 150 GHz with current distance 300 au < r < 600 au and heliocentric angular velocityy <?CDATA $1\buildrel{\,\prime}\over{.} 5\,{\mathrm{yr}}^{-1}\lt v\cdot \tfrac{500\,\mathrm{au}}{r}\lt 2\buildrel{\prime\prime}\over{.} 3\,{\mathrm{yr}}^{-1}$?> 1 .' 5 yr – 1 < v · 500 au r < 2 ." 3 yr – 1 , corresponding to low-to-moderate eccentricities. These limits worsen gradually beyond 600 au, reaching 5–15 mJy by 1500 au.

79 ASTRONOMY AND ASTROPHYSICS↗

The Atacama Cosmology Telescope: A search for Planet 9

We use Atacama Cosmology Telescope (ACT) observations at 98 GHz (2015–2019), 150 GHz (2013–2019), and 229 GHz (2017–2019) to perform a blind shift-and-stack search for Planet 9. The search explores distances from 300 au to 2000 au and velocities up to 6\farcm3 per year, depending on the distance (r). For a 5 Earth-mass Planet 9 the detection limit varies from 325 au to 625 au, depending on the sky location. For a 10 Earth-mass planet the corresponding range is 425 au to 775 au. The predicted aphelion and most likely location of the planet corresponds to the shallower end of these ranges. The search covers the whole 18,000 square degrees of the ACT survey. No significant detections are found, which is used to place limits on the millimeter-wave flux density of Planet 9 over much of its orbit. Overall we eliminate roughly 17% and 9% of the parameter space for a 5 and 10 Earth-mass Planet 9, respectively. These bounds approach those of a recent INPOP19a ephemeris-based analysis, but do not exceed it. We also provide a list of the 10 strongest candidates from the search for possible follow-up. More generally, we exclude (at 95% confidence) the presence of an unknown solar system object within our survey area brighter than 4–12 mJy (depending on position) at 150 GHz with current distance 300 au < r < 600 au and heliocentric angular velocity 1\farcm5 per yr < v x (500au/r) < 2\farcs3 per yr, corresponding to low-to-moderate eccentricities. These limits worsen gradually beyond 600 au, reaching 5–15 mJy by 1500 au.

Sigurd Naess↗

Electric field dynamics in nitride structures containing quaternary alloy (Al, In, Ga)N

Molecular beam epitaxy growth and basic physical properties of quaternary AlInGaN layers, sufficiently thick for construction of electron blocking layers (EBL), embedded in ternary InGaN layers are presented. Transmission electron microscopy (TEM) measurement revealed good crystallographic structure and compositional uniformity of the quaternary layers contained in other nitride layers, which are typical for construction of nitride based devices. The AlInGaN layer was epitaxially compatible to InGaN matrix, strained, and no strain related dislocation creation was observed. The strain penetrated for limited depth, below 3 nm, even for relatively high content of indium (7%). For lower indium content (0.6%), the strain was below the detection limit by TEM strain analysis. The structures containing quaternary AlInGaN layers were studied by time dependent photoluminescence (PL) at different temperatures and excitation powers. It was shown that PL spectra contain three peaks: high energy donor bound exciton peak from the bulk GaN (DX GaN) and the two peaks (A and B) from InGaN layers. No emission from quaternary AlInGaN layers was observed. An accumulation of electrons on the EBL interface in high-In sample and formation of 2D electron gas (2DEG) was detected. The dynamics of 2DEG was studied by time resolved luminescence revealing strong dependence of emission energy on the 2DEG concentration. Theoretical calculations as well as power-dependence and temperature-dependence analysis showed the importance of electric field inside the structure. At the interface, the field was screened by carriers and could be changed by illumination. From these measurements, the dynamics of electric field was described as the discharge of carriers accumulated on the EBL.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A SEARCH FOR ADDITIONAL PLANETS IN FIVE OF THE EXOPLANETARY SYSTEMS STUDIED BY THE NASA EPOXI MISSION

We present time series photometry and constraints on additional planets in five of the exoplanetary systems studied by the EPOCh (Extrasolar Planet Observation and Characterization) component of the NASA EPOXI mission: HAT-P-4, TrES-3, TrES-2, WASP-3, and HAT-P-7. We conduct a search of the high-precision time series for photometric transits of additional planets. We find no candidate transits with significance higher than our detection limit. From Monte Carlo tests of the time series using putative periods from 0.5 days to 7 days, we demonstrate the sensitivity to detect Neptune-sized companions around TrES-2, sub-Saturn-sized companions in the HAT-P-4, TrES-3, and WASP-3 systems, and Saturn-sized companions around HAT-P-7. We investigate in particular our sensitivity to additional transits in the dynamically favorable 3:2 and 2:1 exterior resonances with the known exoplanets: if we assume coplanar orbits with the known planets, then companions in these resonances with HAT-P-4b, WASP-3b, and HAT-P-7b would be expected to transit, and we can set lower limits on the radii of companions in these systems. In the nearly grazing exoplanetary systems TrES-3 and TrES-2, additional coplanar planets in these resonances are not expected to transit. However, we place lower limits on the radii of companions that would transit if the orbits were misaligned by 2.{sup 0}0 and 1.{sup 0}4 for TrES-3 and TrES-2, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Disposable Biosensor Based on Amidase/CeO2/GNR Modified Inkjet-printed CNT Electrodes-droplet Based Paracetamol Detection in Biological Fluids for “Point-of-care” Applications

A disposable acetaminophen biosensor based on inkjet-printed CNT electrodes (IJPCNT) modified with amidase/cerium dioxide@graphene nanoribbons composite was developed (ACeO2@GNR/IJPCNT). The enzyme amidase A was used for the first time as a recognition element. Inkjet-printed CNT electrodes served as a basis for the construction of a biosensor that enables droplet detection using 5 μL sample volume. The biosensor showed high selectivity, sensitivity, a low detection limit of 0.18 μM and a wide working linear range from 1 to 100 μM. The proposed approach allows fast and reliable detection of acetaminophen in biological fluids with negligible matrix effect and remarkable reproducibility. © 2019 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrasensitive detection of Hg{sup 2+} using oligonucleotide-functionalized AlGaN/GaN high electron mobility transistor

An oligonucleotide-functionalized ion sensitive AlGaN/GaN high electron mobility transistor (HEMT) was fabricated to detect trace amounts of Hg{sup 2+}. The advantages of ion sensitive AlGaN/GaN HEMT and highly specific binding interaction between Hg{sup 2+} and thymines were combined. The current response of this Hg{sup 2+} ultrasensitive transistor was characterized. The current increased due to the accumulation of Hg{sup 2+} ions on the surface by the highly specific thymine-Hg{sup 2+}-thymine recognition. The dynamic linear range for Hg{sup 2+} detection has been determined in the concentrations from 10{sup −14} to 10{sup −8} M and a detection limit below 10{sup −14} M level was estimated, which is the best result of AlGaN/GaN HEMT biosensors for Hg{sup 2+} detection till now.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics of HIV-1 Quasispecies during Antiviral Treatment Dissected Using Ultra-Deep Pyrosequencing

Ultra-deep pyrosequencing (UDPS) allows identification of rare HIV-1 variants and minority drug resistance mutations, which are not detectable by standard sequencing. Here, UDPS was used to analyze the dynamics of HIV-1 genetic variation in reverse transcriptase (RT) (amino acids 180–220) in six individuals consecutively sampled before, during and after failing 3TC and AZT containing antiretroviral treatment. Optimized UDPS protocols and bioinformatic software were developed to generate, clean and analyze the data. The data cleaning strategy reduced the error rate of UDPS to an average of 0.05%, which is lower than previously reported. Consequently, the cut-off for detection of resistance mutations was very low. A median of 16,016 (range 2,406–35,401) sequence reads were obtained per sample, which allowed detection and quantification of minority resistance mutations at amino acid position 181, 184, 188, 190, 210, 215 and 219 in RT. In four of five pre-treatment samples low levels (0.07–0.09%) of the M184I mutation were observed. Other resistance mutations, except T215A and T215I were below the detection limit. During treatment failure, M184V replaced M184I and dominated the population in combination with T215Y, while wild-type variants were rarely detected. Resistant virus disappeared rapidly after treatment interruption and was undetectable as early as after 3 months. In most patients, drug resistant variants were replaced by wild-type variants identical to those present before treatment, suggesting rebound from latent reservoirs. With this highly sensitive UDPS protocol preexisting drug resistance was infrequently observed; only M184I, T215A and T215I were detected at very low levels. Similarly, drug resistant variants in plasma quickly decreased to undetectable levels after treatment interruption. The study gives important insights into the dynamics of the HIV-1 quasispecies and is of relevance for future research and clinical use of the UDPS technology.

59 BASIC BIOLOGICAL SCIENCES↗