Robustness of the smartpixels classifier for different simulated sensor geometries and non-ideal detector conditions

Pixel tracking detectors at upcoming collider experiments will see unprecedented charged-particle densities. Real-time data reduction on the detector will enable higher granularity and faster readout, possibly enabling the use of the pixel detector in high-rate online event selection, such as the ATLAS or CMS first-level trigger systems. This data reduction can be accomplished with a neural network (NN) in the readout chip bonded with the sensor that recognizes and rejects tracks with low transverse momentum (p T ) based on the geometrical shape of the charge deposition (“cluster”). To design viable detectors for deployment, the dependence of the NN as a function of the sensor geometry, external magnetic field, irradiation, and noise must be understood. In this paper, we present first studies of the efficiency and data reduction for planar pixel sensors exploring these parameters. For the CMS HL-LHC sensor geometry, we obtain a signal efficiency of (91.9 ± 0.7)% and a data reduction of (29.7 ± 1.0)%. A smaller sensor pitch in the bending direction improves the p T discrimination, but a larger pitch can be partially compensated with detector thickness. Any accumulated radiation damage also changes the cluster shape, reducing the signal efficiency compared to the baseline by approximately 30–60% in absolute terms, but nearly all of the performance can be recovered through retraining of the network and updating the weights. Finally, the impact of noise was investigated, and retraining the network on noise-injected datasets was found to maintain performance within 6% of the baseline network trained and evaluated on noiseless data. •ASIC-compatible track-momentum classifier is robust in realistic detector conditions.•About 90% signal efficiency and 30% data reduction per layer for CMS HL-LHC geometry.•Single-layer signal efficiency increases for smaller pixel pitch or thicker sensors.•Performance with noise or after radiation damage mostly recovered by retraining.

Shekar, Danush [Illinois U., Chicago] (ORCID:00000↗

Testing of a Line Driver With Configurable Pre-Emphasis on Lossy Transmission Lines

Rare-event physics experiments such as the Deep Underground Neutrino Experiment (DUNE) or the next Enriched Xenon Observatory (nEXO) experiment search for rare, low-energy events, detected by sensitive detectors immersed in a cryogenic noble liquid (e.g., liquid argon or xenon). Readout electronics used within such detectors must consume minimal power while operating reliably in cryogenic environments. Furthermore, in the case of nEXO, maximizing the radiopurity of the environment is vital to minimize background noise, thus placing strict limits on the volume of dielectric materials, leading to high-loss data cables spanning distances up to 12 m. Such cables cause high attenuation and intersymbol interference (ISI), resulting in a high bit-error rate (BER). These issues were addressed by developing an integrated line driver with configurable pre-emphasis in a 65-nm CMOS process. The pre-emphasis parameters can be programmed to minimize BER for specific cables and data rates under power constraints. Here, the driver was tested at both room and cryogenic temperatures. In both cases, the output BER was found to be strongly correlated with the pre-emphasis settings. Furthermore, analysis and simulation showed that adapting the pre-emphasis settings based on the incoming bit sequence can further improve performance with minimal changes to the current solution.

47 OTHER INSTRUMENTATION↗

Preliminary Assessment of Microwave Readout Multiplexing Factor

Ultra-high resolution microcalorimeter gamma spectroscopy is a new non-destructive assay technology for measurement of plutonium isotopic composition, with the potential to reduce total measurement uncertainty to a level competitive with destructive analysis methods [1-4]. Achieving this level of performance in practical applications requires not only the energy resolution now routinely achieved with transition-edge sensor microcalorimeter arrays (an order of magnitude better than for germanium detectors) but also high throughput. Microcalorimeter gamma spectrometers have not yet achieved detection efficiency and count rate capability that is comparable to germanium detectors, largely because of limits from existing readout technology. Microcalorimeter detectors must be operated at low temperature to achieve their exceptional energy resolution. Although the typical 100 mK operating temperatures can be achieved with reliable, cryogen-free systems, the cryogenic complexity and heat load from individual readout channels for large sensor arrays is prohibitive. Multiplexing is required for practical systems. The most mature multiplexing technology at present is time-division multiplexing (TDM) [3, 5-6]. In TDM, the sensor outputs are switched by applying bias current to one SQUID amplifier at a time. Transition-edge sensor (TES) microcalorimeter arrays as large as 256 pixels have been developed for X-ray and gamma-ray spectroscopy using TDM technology. Due to bandwidth limits and noise scaling, TDM is limited to a maximum multiplexing factor of approximately 32-40 sensors on one readout line [8]. Increasing the size of microcalorimeter arrays above the kilopixel scale, required to match the throughput of germanium detectors, requires the development of a new readout technology with a much higher multiplexing factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial assessment of multilayer silicon detectors for hard X-ray imaging

Silicon detectors with lower material budget, ultrafast readout and radiation hardness are under developments. These unique features make pixelized silicon sensors a good option for hard X-ray imaging. To verify the performance of spatial resolution and energy sensitivity of silicon sensors to hard X-rays, a two layer setup of Pixelink PL-D725MU sensors has been tested at the Argonne National Laboratory Advanced Photon Source (APS) ID-10 sector with 29.2 keV high photon flux (4.5 x 10(8) to 4.5 x 10(10) photons per second) X-rays. Better than 3 mu m spatial resolution and clear energy characterization have been achieved by both layers. Commercial CMOS sensors with superior spatial resolution could be used for phase contrast imaging in current synchrotrons. These studies pave the path for future multilayer ultrafast silicon sensor development with ns to sub-ns readout speeds in hard X-ray imaging at synchrotrons and XFEL beamlines.

Hard X-ray imaging↗

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Development of a unit cell for a Ge:Ga detector array

Two modules of gallium-doped germanium (Ge:Ga) infrared detectors with integrated multiplexing readouts and supporting drive electronics were designed and tested. This development investigated the feasibility of producing two-dimensional Ge:Ga arrays by stacking linear modules in a housing capable of providing uniaxial stress for enhanced long-wavelength response. Each module includes 8 detectors (1x1x2 mm) mounted to a sapphire board. The element spacing is 12 microns. The back faces of the detector elements are beveled with an 18 deg angle, which was proved to significantly enhance optical absorption. Each module includes a different silicon metal-oxide semiconductor field effect transistor (MOSFET) readout. The first circuit was built from discrete MOSFET components; the second incorporated devices taken from low-temperature integrated circuit multiplexers. The latter circuit exhibited much lower stray capacitance and improved stability. Using these switched-FET circuits, it was demonstrated that burst readout, with multiplexer active only during the readout period, could successfully be implemented at approximately 3.5 K.

Source record↗

High-spatial resolution and high-spectral resolution detector for use in the measurement of solar flare hard X-rays

In the areas of high spatial resolution, the evaluation of a hard X-ray detector with 65 micron spatial resolution for operation in the energy range from 30 to 400 keV is proposed. The basic detector is a thick large-area scintillator faceplate, composed of a matrix of high-density scintillating glass fibers, attached to a proximity type image intensifier tube with a resistive-anode digital readout system. Such a detector, combined with a coded-aperture mask, would be ideal for use as a modest-sized hard X-ray imaging instrument up to X-ray energies as high as several hundred keV. As an integral part of this study it was also proposed that several techniques be critically evaluated for X-ray image coding which could be used with this detector. In the area of high spectral resolution, it is proposed to evaluate two different types of detectors for use as X-ray spectrometers for solar flares: planar silicon detectors and high-purity germanium detectors (HPGe). Instruments utilizing these high-spatial-resolution detectors for hard X-ray imaging measurements from 30 to 400 keV and high-spectral-resolution detectors for measurements over a similar energy range would be ideally suited for making crucial solar flare observations during the upcoming maximum in the solar cycle.

Desai, U. D.↗

Beam test results of 3D pixel detectors constructed with poly-crystalline CVD diamond

As a possible candidate for extremely radiation tolerant tracking devices we present a novel detector design - namely 3D detectors - based on poly-crystalline CVD diamond sensors with a pixel readout. The fabrication of recent 3D detectors as well their results in recent beam tests are presented. We measured the hit efficiency and signal response of two 3D diamond detectors with 50 × 50 μm cell sizes using pixel readout chip technologies currently used at CMS and ATLAS. In all runs, both devices attained efficiencies >98 % in a normal incident test beam of minimum ionising particles. The highest efficiency observed during the beam tests was 99.2 %.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A high resolution gamma-ray spectrometer based on superconducting microcalorimeters

Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gamma-ray microcalorimeters, based on transition-edge sensors (TESs), possible. At these collecting areas, gamma microcalorimeters can utilize their unprecedented energy resolution to perform spectroscopy in a number of applications that are limited by closely-spaced spectral peaks, for example, the nondestructive analysis of nuclear materials. We have built a 256 pixel spectrometer with an average full-width-at-half-maximum energy resolution of 53 eV at 97 keV, a useable dynamic range above 400 keV, and a collecting area of 5 cm{sup 2}. We have demonstrated multiplexed readout of the full 256 pixel array with 236 of the pixels (91%) giving spectroscopic data. This is the largest multiplexed array of TES microcalorimeters to date. This paper will review the spectrometer, highlighting the instrument design, detector fabrication, readout, operation of the instrument, and data processing. Further, we describe the characterization and performance of the newest 256 pixel array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Search for Low-Mass Dark Matter with the Cryogenic Dark Matter Search and the Development of Highly Multiplexed Phonon-Mediated Particle Detectors

A wide variety of astrophysical observations indicate that approximately 85% of the matter in the universe is nonbaryonic and nonluminous. Understanding the nature of this "dark matter" is one of the most important outstanding questions in cosmology. Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter since they would be thermally produced in the early universe in the correct abundance to account for the observed relic density of dark matter. If WIMPs account for the dark matter, then rare interactions from relic WIMPs should be observable in terrestrial detectors. Recently, unexplained excess events in the DAMA/LIBRA, CoGeNT, and CRESST-II experiments have been interpreted as evidence of scattering from WIMPs with masses ~10 GeV and spin-independent scattering cross sections of 10-41-10-40 cm2. The Cryogenic Dark Matter Search (CDMS II) attempts to identify WIMP interactions using an array of cryogenic germanium and silicon particle detectors located at the Soudan Underground Laboratory in northern Minnesota. In this dissertation, data taken by CDMS II are reanalyzed using a 2 keV recoil energy threshold to increase the sensitivity to WIMPs with masses ~10 GeV. These data disfavor an explanation for the DAMA/LIBRA, CoGeNT, and CRESST-II results in terms of spin-independent elastic scattering of WIMPs with masses ≲12 GeV, under standard assumptions. At the time of publication, they provided the strongest constraints on spin-independent elastic scattering from 5-9 GeV, ruling out previously unexplored parameter space. To detect WIMPs or exclude the remaining parameter space favored by the most popular models will ultimately require detectors with target masses ≳1 ton, requiring an increase in mass by more than two orders of magnitude over CDMS II. For cryogenic detectors such as CDMS, scaling to such large target masses will require individual detector elements to be fabricated more quickly and cheaply, while maintaining the nearly background-free operation of the existing experiment. We describe the development of athermal phonon mediated particle detectors using Microwave Kinetic Inductance Detectors (MKIDs), which could provide a simpler path to extending the CDMS detector technology to the ton scale. Results from prototype devices have demonstrated energy resolutions as good as σ = 0.55 keV at 30 keV, comparable to existing CDMS II detectors. Such designs can be scaled to kg-scale detector elements, while reducing the complexity of the detector fabrication and cryogenic readout electronics relative to existing designs. Since MKIDs are naturally multiplexed in the frequency domain, MKID-based designs also allow much finer pixelization of the phonon sensor, which is expected to enhance background rejection for large detectors while simultaneously reducing the number of wires needed to read out the detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument Development and Gamma Spectroscopy with Strontium Iodide

Development of the Europium-doped Strontium Iodide scintillator, SrI2(Eu), involves advances in crystal growth, optics and readout methodology for prototype detectors. We have demonstrated energy resolution of 3% at 662 keV for a 26 cm3 SrI2(Eu) crystal, which is comparable to the performance obtained with Cerium-doped Lanthanum Bromide of equivalent size. Compared to standard analog readout, use of a digital readout method allows improved energy resolution to be obtained with large-volume SrI2(Eu) crystals. Comparative gamma spectra acquired with LaBr3(Ce) and NaI(Tl) quantitatively depict the value of the high resolution and low intrinsic radioactivity of SrI2(Eu) in discriminating closely spaced gamma lines for radioisotope identification applications.

Cherepy, Nerine↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-Hard Parallel Readout Circuit for Low-Frequency Voltage Signal Measurements

NASA Goddard Space Flight Center (GSFC) has successfully developed and tested a custom-designed low-noise multi-channel digitizer (MCD) application specific integrated circuit (ASIC) for operation in harsh radiation environments. The MCD-ASIC is optimized for low-frequency and low-voltage signal measurements from sensors and transducers. It has 20 input channels where each channel is comprised of auto-zeroed chopper variable-gain amplifier, post amplifier, and a second order ∑∆ modulator. ∑∆ analog-to-digital converter (ADC) relies on oversampling and noise shaping to achieve high-resolution conversion. However, the MCD-ASIC requires digital filtering and decimation to convert the output single bit streams from the ADC to useful data words. A parallel digital platform such as a field-programmable-gate-array (FPGA) is highly suitable to fully leverage the capabilities of the MCD-ASIC. The FPGA controls the MCD-ASIC via serial peripheral interface (SPI) protocol and acquires data from it. A Python-script communicates with the FPGA board through a USB interface on a cross operating platform. Using this architecture, the system is capable of monitoring up to 20 voltage readout channels simultaneously in a real-time manner. Each channel’s parameters can be programmed independently allowing maximum user versatility. In this paper, we present analysis of the analog front-end, the implementation of the digital processing unit on the FPGA, and provide noise performance results from the MCD-ASIC readout.

ASIC↗

Pixel detectors in double beta decay experiments, a new approach for background reduction

Double beta decay (ββ) experiments are challenging frontiers in contemporary physics. These experiments have the potential to investigate more about neutrinos (eg. nature and mass). The main challenge for these experiments is the reduction of background. The group at IEAP, CTU in Prague is investigating a new approach using pixel detectors Timepix. Pixel detector offer background reduction capabilities with its ability to identify the particle interaction (from the 2D signature it generates). However, use of pixel detectors has some challenges such as the presence of readout electronics near the sensing medium and heat dissipation. Different aspects of pixel setup (identification of radio-impurities, selection of radio-pure materials) and proposed experimental setup are presented. Also, results of preliminary background measurements (performed on the surface and in the underground laboratories) using the prototype setups are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The STAR MAPS-based PiXeL detector

The PiXeL detector (PXL) for the Heavy Flavor Tracker (HFT) of the STAR experiment at RHIC is the first application of the state-of-the-art thin Monolithic Active Pixel Sensors (MAPS) technology in a collider environment. Here, custom built pixel sensors, their readout electronics and the detector mechanical structure are described in detail. Selected detector design aspects and production steps are presented. The detector operations during the three years of data taking (2014–2016) and the overall performance exceeding the design specifications are discussed in the conclusive sections of this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhancements to a Superconducting Quantum Interference Device (SQUID) Multiplexer Readout and Control System

Far-infrared detector arrays such as the 16x32 superconducting bolometer array for the SAFIRE instrument (flying on the SOFIA airborne observatory) require systems of readout and control electronics to provide translation between a user-driven, digital PC and the cold, analog world of the cryogenic detector. In 2001, the National Institute of Standards and Technology (NIST) developed their Mark III electronics for purposes of control and readout of their 1x32 SQUID Multiplexer chips. We at NASA s Goddard Space Flight Center acquired a Mark 111 system and subsequently designed upgrades to suit our and our collaborators purposes. We developed an arbitrary, programmable multiplexing system that allows the user to cycle through rows in a SQUID array in an infinite number of combinations. We provided hooks in the Mark III system to allow readout of signals from outside the Mark 111 system, such as telescope status information. Finally, we augmented the heart of the system with a new feedback algorithm implementation, flexible diagnostic tools, and informative telemetry.

Forgione, J.↗