Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

X-ray diffraction study of Ba{sub 3}TaFe{sub 3}Si{sub 2}O{sub 14} single crystal—a promising langasite-type multiferroic

Ba{sub 3}TaFe{sub 3}Si{sub 2}O{sub 14} single crystals (sp. gr. P321, Z = 1), promising langasite-type multiferroics, have been grown by floating zone melting. An accurate X-ray diffraction study of Ba{sub 3}TaFe{sub 3}Si{sub 2}O{sub 14} single crystal has been performed using two datasets, obtained independently for two different orientations of the same sample on a diffractometer equipped with a CCD area detector at 295 K. Structure refinement is performed based on an averaged dataset: a = 8.5355(1) Å, c = 5.2332(1) Å, sp. gr. P321, Z = 1; the R factors of model structure refinement were found to be R/wR = 1.02/1.23% for 4552 independent reflections. Disordering asymmetry is revealed for the magnetic Fe ion in the 3f site and the Ba cation in the 3e site.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of the methods for simulating the neutron spectrometers and neutron-scattering experiments

Reviewed are the results of simulating the neutron scattering instruments with the program package VITESS upgraded by the routines for treating the polarized neutrons, as developed by the authors. The reported investigations have been carried out at the Frank Laboratory for Neutron Physics at JINR in collaboration with the Juelich research center (Germany). The performance of the resonance and gradient adiabatic spin flippers, the Drabkin resonator, the classical and resonance spin-echo spectrometers, the spin-echo diffractometer for the small-angle neutron scattering, and the spin-echo spectrometer with rotating magnetic fields is successfully modeled. The methods for using the 3D map of the magnetic field from the input file, either mapped experimentally or computed using the finite-elements technique, in the VITESS computer code, are considered in detail. The results of neutron-polarimetry experiments are adequately reproduced by our simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of substrate temperature on structural and optical properties of RF sputtered ZnMnO thin films

The ZnMnO thin films were deposited on glass substrates by radio frequency magnetron sputtering method. The properties of ZnMnO thin films were investigated by high-resolution x-ray diffractometer (HRXRD),atomic force microscopy (AFM), UV-Vis spectrometer and room temperature photoluminescence (PL), under the influence of substrate temperature. The substrate temperature was varied from 300, 400 and 500°C. With increasing the substrate temperature, the structure of the films changed from cubic to hexagonal. The cubic ZnMnO thin films grown along [210] direction, while the hexagonal ones grown along [002] direction. The changes in surface morphology provided a proof on the structural transition. Also, decrease and increase of optical band gap is associated with cubic or hexagonal structure of the films.

36 MATERIALS SCIENCE↗

Machine Learning Based System for Automated Estimation of Crystal Unit Cell Parameters from X-ray Diffraction Powder Patterns (MLCell) v0.1

This software uses machine learning models to perform inference on X-ray diffraction powder patterns, output from a diffractometer, to estimate all 6 unit cell parameters of crystalline lattices. Novel aspects of this software originated from the incorporation of concepts from crystallography to an ML-based approach; The resulting method achieves new performance capabilities without significant loss of accuracy and with less computationally intensive models.

Oklejas, Vanessa↗

NOMAD total scattering dataset for SMC data challenge

The data provided for this challenge was measured using the Nanoscale-Ordered Materials Diffractometer (NOMAD) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The data is stored in a hdf5 file following the NeXus standard and can be read with tools built for either. While the NeXus format is self-describing, there is benefit to explaining some details. The data is stored in 4 NXentries in the file. The NXentries that begin with 'amorphous_SiO2' are for the amorphous data, and the NXentries that begin with 'crystalbolite_SiO2' are for the crystalline material. Solutions that were produced by the scientist are in the entries that end with '_byhand'. Each of the NXdata groups are the plottable data with the 'signal', axes, and (in the case of by-hand components) 'auxiliary_signals' describing which fields should be used. The by-hand component ranges are listed in a 'component' attribute of the various signals. The filtered Sr data is the Fourier transform of the combined components. The data can be quickly viewed using tools such as Nexpy or HDFview. Most languages have libraries that can work with HDF5 (eg. H5py for python) a partial list is provided at https://manual.nexusformat.org/utilities.html The data can be quickly viewed using tools such as Nexpy or HDFview. https://neutrons.ornl.gov/nomad https://www.hdfgroup.org/solutions/hdf5 https://www.nexusformat.org/

36 MATERIALS SCIENCE↗

SNAP diffraction dataset for 2023 SMC data challenge

The data provided this challenge is ice under high pressure measured using the Spallation Neutrons and Pressure Diffractometer (SNAP) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The data is stored in a hdf5 file following the NeXus standard and can be read with tools built for either. While the NeXus format is self-describing, there is benefit to explaining some details. The data is stored in a single NXdata entry within a single NXentry. The NXdata has several fields denoting the 3-dimensional data (signal), the axes (D0 is the Qx axis, D1 is the Qy axis, and D2 is the Qz axis), and fields for the uncertainties and masking information. The data can be quickly viewed using the LoadMD algorithm and slice viewer in the Mantid workbench https://www.mantidproject.org.

36 MATERIALS SCIENCE↗

Neutron powder diffraction, Mossbauer Spectroscopy and Optical Spectroscopy to study magnetic and nuclear lattices in Fe-based oxychlorides Ca2FeO3Cl, Sr2FeO3Cl and Sr3Fe2O5Cl2

Data for Neutron Diffraction, Mossbauer Spectoscopy and Optical Spectroscopy are contained on all three samples (Ca2FeO3Cl, Sr2FeO3Cl, and Sr3Fe2O5Cl2). Mossbauer data are in the folder "MossbauerSpectroscopy". This contains details of files and examples to read the data. The Optical Spectroscopy are in the folder "AbsorptionData", this contains one file with explanatory headers. The neutron diffraction data are in the "NeutronDiffractionData" folder. The data was collected on the HB-2A powder diffractometer at HFIR. The autoreduced files are corrected using a vanadium standard and are in arbitrary intensity units. The RawData folder contains the uncorrected data with metadata for motor positions and temperature. All measurements were collected with a constant neuton wavelength of 2.41 Angstrom. An excel spreadsheet "NeutronDiffractionData_IPTS-29118_summary" contains details for each scan. Sr3Fe2O5Cl2 data were collected at only room temperature. Ca2FeO3Cl and Sr2FeO3Cl data were collected at 4K and room temperature. The autoreduced .dat fileformat is three columns corresponding to: Two-theta, Intensity and Intensity_error.

fe-based oxychlorides↗

Macromolecular powder diffraction : structure solution via molecular.

Macromolecular powder diffraction is a burgeoning technique for protein structure solution - ideally suited for cases where no suitable single crystals are available. Over the past seven years, pioneering work by Von Dreele et al. [1,2] and Margiolaki et al. [3,4] has demonstrated the viability of this approach for several protein structures. Among these initial powder studies, molecular replacement solutions of insulin and turkey lysozyme into alternate space groups were accomplished. Pressing the technique further, Margiolaki et al. [5] executed the first molecular replacement of an unknown protein structure: the SH3 domain of ponsin, using data from a multianalyzer diffractometer. To demonstrate that cross-species molecular replacement using image plate data is also possible, we present the solution of hen egg white lysozyme using the 60% identical human lysozyme (PDB code: 1LZ1) as the search model. Due to the high incidence of overlaps in powder patterns, especially in more complex structures, we have used extracted intensities from five data sets taken at different salt concentrations in a multi-pattern Pawley refinement. The use of image plates severely increases the overlap problem due to lower detector resolution, but radiation damage effects are minimized with shorter exposure times and the fact that the entire pattern is obtained in a single exposure. This image plate solution establishes the robustness of powder molecular replacement resulting from different data collection techniques.

59 BASIC BIOLOGICAL SCIENCES↗

VULCAN: A “hammer” for high-temperature materials research

Understanding changes in chemistry, microstructure, and physical properties during synthesis, processing, testing, and even service is vital for materials design and performance. Compared to traditional postmortem material characterization tools, in situ crystallographic characterization can provide considerable data and information on evolution of chemistry, dislocations, twinning, texture, and strains when a material is under external stimuli. Neutrons especially are able to probe material bulk properties and behaviors in extreme environments, thanks to their deep penetrating power and unique sensitivity to differentiate elements from lightweight to transition-metal atoms. In this article, we introduce and describe a diffractometer named VULCAN, which is located at Oak Ridge National Laboratory. Finally, this represents a powerful tool to understand materials properties and behaviors under complex environments, in particular, at high temperatures.

36 MATERIALS SCIENCE↗

A scalable transformer model for real-time decision making in neutron scattering experiments

The U.S. Department of Energy's (DOE's) neutron research facilities at Oak Ridge National Laboratory (ORNL), including the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS), are a state-of-the-art neutron scattering facility that allows researchers to study the structure and dynamics of materials at the atomic scale. At the SNS, neutrons are measured using the time-of-flight (TOF) technique as they move through a neutron beamline to interact with a sample. Large volumes of neutron scattering data are collected and recorded in neutron event mode. Optimal productivity of the TOF instrument is limited due to the lack of real-time data analysis tools. The large amount of data generated by the experiments can be challenging to process and analyze in real time, particularly for experiments that require rapid feedback and adjustment of experimental parameters. The regular computer/workstation cannot keep up with the experiment speed to provide real-time feedback to adjust experimental parameters, so connecting the supercomputers available to the neutron facility is necessary to achieve real-time data analysis and experiment steering. To address this challenge, we exploit the Frontier supercomputer at Oak Ridge Leadership Computing Facility (OLCF) to train a scalable temporal fusion transformer model for real-time decision making of TOF neutron scattering experimentation. Here, in this paper, we present the results using Frontier to provide the processing power needed to rapidly process and analyze large volumes of single-crystal diffraction data collected at TOPAZ, a neutron time-of-flight Laue single-crystal diffractometer at the SNS.

97 MATHEMATICS AND COMPUTING↗

Solid Phase Characterization of Tank 241-AY-102 Annulus Space Particulate

The Special Analytical Studies Group at the 222-S Laboratory (222-S) examined the particulate recovered from a series of samples from the annular space of tank 241-AY-102 (AY-102) using solid phase characterization (SPC) methods. These include scanning electron microscopy (SEM) using the ASPEX® scanning electron microscope, X-ray diffraction (XRD) using the Rigaku® MiniFlex X-ray diffractometer, and polarized light microscopy (PLM) using the Nikon® Eclipse Pol optical microscope. The SEM is equipped with an energy dispersive X-ray spectrometer (EDS) to provide chemical information.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Institute for Advanced Materials at University of Louisville

In this project, a university-wide, academic center has been established entitled “Institute for Advanced Materials and Renewable Energy”. In this institute, a comprehensive materials characterization facility has been established by co-locating several existing characterization equipment and acquiring several state of the art instrumentation such as field emission transmission electron microscope, scanning electron microscope, high resolution X-ray diffractometer, Particle Size Distribution/Zeta Potential measurement system, and Ultra-microtome for TEM specimen. In addition, a renewable energy conversion and storage research facility was also established by acquiring instrumentation such as UV-Vis absorption spectroscopy, Atomic Layer Deposition reactor, Solar light simulator, oxygen-free glove box, potentiostat/galvanostats and other miscellaneous items. The institute is staffed with three full-time staff members (one senior research technologist, a senior PhD level research scientist and a junior research scientist) to enable proper use of the techniques. About thirty faculty, fifty graduate students and several researchers access the facilities on a routine basis. Several industry R&D organizations (SudChemie, Optical Dynamics and Hexion) utilize the facility.

36 MATERIALS SCIENCE↗

Connecticut State University System Initiative for Nanotechnology-Related Equipment, Faculty Development and Curriculum Development

DOE grant used for partial fulfillment of necessary laboratory equipment for course enrichment and new graduate programs in nanotechnology at the four institutions of the Connecticut State University System (CSUS). Equipment in this initial phase included variable pressure scanning electron microscope with energy dispersive x-ray spectroscopy elemental analysis capability [at Southern Connecticut State University]; power x-ray diffractometer [at Central Connecticut State University]; a spectrophotometer and spectrofluorimeter [at Eastern Connecticut State University; and a Raman Spectrometer [at Western Connecticut State University]. DOE's funding was allocated for purchase and installation of this scientific equipment and instrumentation. Subsequently, DOE funding was allocated to fund the curriculum, faculty development and travel necessary to continue development and implementation of the System's Graduate Certificate in Nanotechnology (GCNT) program and the ConnSCU Nanotechnology Center (ConnSCU-NC) at Southern Connecticut State University. All of the established outcomes have been successfully achieved. The courses and structure of the GCNT program have been determined and the program will be completely implemented in the fall of 2013. The instrumentation has been purchased, installed and has been utilized at each campus for the implementation of the nanotechnology courses, CSUS GCNT and the ConnSCU-NC. Additional outcomes for this grant include curriculum development for non-majors as well as faculty and student research.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Solid Phase Characterization of Tank 241-C-108 Residual Waste Solids Samples

This report presents the results for solid phase characterization (SPC) of solid samples removed from tank 241-C-108 (C-108) on August 12-13,2012, using the off-riser sampler. Samples were received at the 222-S Laboratory on August 13 and were described and photographed. The SPC analyses that were performed include scanning electron microscopy (SEM) using the ASPEX(R)l scanning electron microscope, X-ray diffraction (XRD) using the Rigaku(R) 2 MiniFlex X-ray diffractometer, and polarized light microscopy (PLM) using the Nikon(R) 3 Eclipse Pol optical microscope. The SEM is equipped with an energy dispersive X-ray spectrometer (EDS) to provide chemical information. Gary A. Cooke conducted the SEM analysis, John A. Pestovich performed the XRD analysis, and Dr. Heinz J. Huber performed the PLM examination. The results of these analyses are presented here.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Polarized 3 He in Neutron Scattering (Final Report)

We propose to extend the technique of polarized neutron scattering into new domains by continued development and application of polarized 3 He spin-filters. These devices are particularly relevant to the Spallation Neutron Source, as the polarizing monochromators historically used at reactor sources will usually not be suitable polarizers, and wide-angle polarization analysis will be essential. With prior support from the Office of Science, we have developed neutron spin-filters based on the large spin dependence of the cross section for neutron capture by 3 He, and applied these devices to a small angle neutron scattering spectrometer (SANS), polarized neutron reflectometers, a thermal energy single crystal diffractometer (SCD), and a thermal energy triple-axis instrument. Our developments have been adopted for application on the magnetism reflectometer at the SNS and for the NIST Center for Neutron Research (NCNR) 3He user capability. Results from both these programs are emerging. We have made significant progress in the past grant period on wide-angle polarization analysis. We have also performed several studies relevant to continuous optical pumping, including collaboration on experiments that have revealed neutron beam effects on spin filters that are continuously pumped by spin-exchange optical pumping. We contributed to an experiment on a neutron interferometer, in which the successful results obtained are directly related to both 3He cell technology and high accuracy 3 He-based neutron polarimetry. Implementation of wide-angle polarization analysis will continue to be key thrust for our work in this new proposal. We will also focus on continuous optical pumping and the fundamental issues that determine the achievable 3 He polarization. This project will be carried out by a collaboration involving scientists at NIST, Indiana University, Hamilton College, and the Univ. of Wisconsin who are experts in 3 He polarization techniques, and materials scientists from the NCNR, SNS, and LENS who are neutron scattering experts. We will collaborate with the staff in the new programs at the NCNR and SNS. In addition, we will welcome the opportunity to interact with other laboratories.

36 MATERIALS SCIENCE↗

A New Light Weight Structural Material for Nuclear Structures

Radiation shielding materials are commonly used in nuclear facilities to attenuate the background ionization radiations to a minimum level for creating a safer workplace, meeting regulatory requirements and maintaining high quality performance. The conventional radiation shielding materials have a number of drawbacks: heavy concrete contains a high amount of elements that are not desirable for an effective shielding such as oxygen, silicon, and calcium; a well known limitation of lead is its low machinability and toxicity, which is causing a major environmental concern. Therefore, an effective and environmentally friendly shielding material with increased attenuation and low mass density is desirable. Close-cell composite metal foams (CMFs) and open-cell Al foam with fillers are light-weight candidate materials that we have studied in this project. Close-cell CMFs possess several suitable properties that are unattainable by conventional radiation shielding materials such as low density and high strength for structural applications, high surface area to volume ratio for excellent thermal isolation with an extraordinary energy absorption capability. Open-cell foam is made up of a network of interconnected solid struts, which allows gas or fluid media to pass through it. This unique structure provided a further motive to investigate its application as radiation shields by infiltrating original empty pores with high hydrogen or boron compounds, which are well known for their excellent neutron shielding capability. The resulting open-cell foam with fillers will not only exhibit light weight and high specific surface area, but also possess excellent radiation shielding capability and good processability. In this study, all the foams were investigated for their radiation shielding efficiency in terms of X-ray, gamma ray and neutron. X-ray transmission measurements were carried out on a high-resolution microcomputed tomography (microCT) system. Gamma-emitting sources: 3.0mCi 60 Co, 1.8mCi 137 Cs, 13.5mCi 241 Am, and 5.0mCi 133 Ba were used for gamma-ray attenuation analysis. The evaluations of neutron transmission measurements were conducted at the Neutron Powder Diffractometer beam facility at North Carolina State University. The experimental results were verified theoretically through XCOM and Monte Carlo Z-particle Transport Code (MCNP). A mechanical investigation was performed by means of quasi-static compressive testing. Thermal characterizations were carried out through effective thermal conductivity and thermal expansion analyses in terms of high temperature guarded-comparative-longitudinal heat flow technique and thermomechanical analyzer (TMA), respectively. The experimental results were compared with analytical results obtained from, respectively, Brailsford and Major’s model and modified Turner’s model for verification. Flame test was performed in accordance with United States Nuclear Regulatory Commission (USNRC) standard. CMF sample and a 304L stainless steel control sample were subjected to a fully engulfing fire with an average flame temperature of 800°C for a period of 30 minutes. Finite Element Analysis was conducted to secure the credibility of the experimental results. This research indicates the potential of utilizing the light-weight close-cell CMFs and open-cell Al foam with fillers as shielding material replacing current heavy structures with additional advantage of high-energy absorption and excellent thermal characteristics.

36 MATERIALS SCIENCE↗