Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Instrumentation and Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Instrumentation and Equipment for Three Independent Research Labs

Completed in 2011, Albright's new Science Center includes three independent student and faculty research labs in Biology, Chemistry/Biochemistry, and Physics (separate from teaching labs). Providing independent research facilities, they eliminate disruptions in classrooms and teaching labs, encourage and accommodate increased student interest, and stimulate advanced research. The DOE grant of $369,943 enabled Albright to equip these advanced labs for 21st century science research, with much instrumentation shared among departments. The specialty labs will enable Albright to expand its student-faculty research program to meet growing interest, help attract superior science students, maximize faculty expertise, and continue exceeding its already high rates of acceptance for students applying for postgraduate education or pharmaceutical research positions. Biology instrumentation/equipment supports coursework and independent and collaborative research by students and faculty. The digital shaker, CO 2 and water bath incubators (for controlled cell growth), balance, and micropipettes support cellular biology research in the advanced cell biology course and student-faculty research into heavy metal induction of heat shock proteins in cultured mammalian cells and the development of PCR markers from different populations of the native tree, Franklinia. The gravity convection oven and lyophilizer support research into physical and chemical analysis of floodplain sediments used in assessment of riparian restoration efforts. The Bio-Rad thermocycler permits fast and accurate DNA amplification as part of research into genetic diversity in small mammal populations and how those populations are affected by land-use practices and environmental management. The Millipore water deionizing system and glassware washer provide general support of the independent research lab and ensure quality control of coursework and interdisciplinary research at the intersection of biology, chemistry, and toxicology. Grant purchases support faculty and students working in the areas of plant cellular biology, landscape ecology and wildlife management, wetland restoration, and ecotoxicology of aquatic invertebrates. Chemistry/BioChemistry instrumentation supports a wide range of research and teaching needs. The Dell quad core Xeon processors and Gaussian 09 support computational research efforts of two of our faculty. The computational work of one of these groups is part of close collaboration with one organic chemist and provides support info for the synthetic work of this professor and his students. Computational chemistry studies were also introduced into the physical chemistry laboratory course for junior chemistry concentrators. The AKTA plus system and superdex columns, Thermoscientific Sorvall RC-6 plus superspeed centrifuge, Nanodrop spectrometer, Eppendorf microfuge, Homogenizer and Pipetman pipetters were incorporated into a research project involving purification and characterization of a construct of beta 2-microglobulin by one of our biochemists. The vacuum system (glove box, stand, and pump) makes a significant contribution to the research of our inorganic chemist, the newest department member, working on research projects with four students. The glove box provides the means to carry out their synthetic work in an oxygenless atmosphere. Supporting basic research pursued by faculty and students, the remaining items (refrigerator/freezer units for flammable storage, freezer, refrigerated water bath, rotary evaporator system, vacuum oven, analytical and top-loading balances) were distributed between our biochemistry and chemistry research labs. The Nanodrop spectrometer, Sorvall centrifuge, and rotary evaporator system are used in several junior/senior lab courses in both biochemistry and chemistry. To date, 14 undergraduate research students have been involved in projects using the new instrumentation and equipment provided by this grant. Physics equipment acquired is radically transforming Albright research and teaching capabilities. The two main purchases are an atomic force microscope (AFM) and a scanning tunneling microscope (STM). These two devices allow us to view surfaces at much higher resolution than ever before, even to the level of individual atoms. Already the AFM has been incorporated into courses for advanced physics and biology students, allowing them to view at high resolution material such as carbon nanotubes, cell structure, and proteins. These devices offer possibilities for interdisciplinary collaboration among students and faculty in various departments that have barely begun to be tapped. Additional equipment, such as software, optical tables, lasers, and other support equipment, is also strengthening our research and teaching capabilities in optics-related areas.

99 GENERAL AND MISCELLANEOUS↗

Precision control of multiple quantum cascade lasers for calibration systems

We present a precision, 1-A, digitally interfaced current controller for quantum cascade lasers, with demonstrated temperature coefficients for continuous and 40-kHz full-depth square-wave modulated operation, of 1–2 ppm/ °C and 15 ppm/ °C, respectively. High precision digital to analog converters (DACs) together with an ultra-precision voltage reference produce highly stable, precision voltages, which are selected by a multiplexer (MUX) chip to set output currents via a linear current regulator. The controller is operated in conjunction with a power multiplexing unit, allowing one of three lasers to be driven by the controller, while ensuring protection of controller and all lasers during operation, standby, and switching. Simple ASCII commands sent over a USB connection to a microprocessor located in the current controller operate both the controller (via the DACs and MUX chip) and the power multiplexer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HYMOSS signal processing for pushbroom spectral imaging

The objective of the Pushbroom Spectral Imaging Program was to develop on-focal plane electronics which compensate for detector array non-uniformities. The approach taken was to implement a simple two point calibration algorithm on focal plane which allows for offset and linear gain correction. The key on focal plane features which made this technique feasible was the use of a high quality transimpedance amplifier (TIA) and an analog-to-digital converter for each detector channel. Gain compensation is accomplished by varying the feedback capacitance of the integrate and dump TIA. Offset correction is performed by storing offsets in a special on focal plane offset register and digitally subtracting the offsets from the readout data during the multiplexing operation. A custom integrated circuit was designed, fabricated, and tested on this program which proved that nonuniformity compensated, analog-to-digital converting circuits may be used to read out infrared detectors. Irvine Sensors Corporation (ISC) successfully demonstrated the following innovative on-focal-plane functions that allow for correction of detector non-uniformities. Most of the circuit functions demonstrated on this program are finding their way onto future IC's because of their impact on reduced downstream processing, increased focal plane performance, simplified focal plane control, reduced number of dewar connections, as well as the noise immunity of a digital interface dewar. The potential commercial applications for this integrated circuit are primarily in imaging systems. These imaging systems may be used for: security monitoring systems, manufacturing process monitoring, robotics, and for spectral imaging when used in analytical instrumentation.

Ludwig, David E.↗

Development of a Two Dimensional Synthetic Aperture Radiometer at L-Band

A radiometer that uses aperture synthesis in two dimensions is being built as part of research under NASA's Instrument Incubator Program. The instrument development team consists of engineers at the Goddard Space Flight Center, the University of Massachusetts and Quadrant Engineering. This will be an aircraft instrument operating at L-band which builds on the heritage of Electronically Steered Thinned Array Radiometer (ESTAR). This instrument is a next step in the development of aperture synthesis (STAR technology) to meet the goal of a future mission to monitor soil moisture globally from space. The instrument will be designed to fly on the NASA P-3 aircraft in a nadir pointing mode, although other options are possible. The antenna will consist of an array of modules in a rectangular grid. Each module will be comprised of a printed circuit dual-polarized patch and integrated receiver. The distribution of modules within the rectangular array will be adjustable so that several different imaging configurations (e.g. '+', 'Y', 'T') can be employed. The integrated receiver will provide amplification and conversion to infrared (IF). The IF signal will be routed to a processor where the required correlations performed. The I and Q channels will be created digitally and the correlations will be done digitally in this processor. The digitization will be done with sufficient bits to study the effects of quantization on radiometer performance. A computer/controller will store the data for conversion to an image and will also perform temperature control and other data interfacing and housekeeping tasks. The design of critical components has been completed and hardware is being assembled to test the individual elements. It is expected that a complete two-channel correlator will be tested by the end of 2000 and that the complete instrument will be ready for flight tests the following summer (2001).

LeVine, D. M.↗

Adaptive linear predictor FIR filter based on the Cyclone V FPGA with HPS to reduce narrow band RFI in AERA radio detection of cosmic rays

We present the new approach to a filtering of radio frequency interferences (RFI) in the Auger Engineering Radio Array (AERA) which study the electromagnetic part of the Extensive Air Showers. The radio stations can observe radio signals caused by coherent emissions due to geomagnetic radiation and charge excess processes. AERA observes frequency band from 30 to 80 MHz. This range is highly contaminated by human-made RFI. In order to improve the signal to noise ratio RFI filters are used in AERA to suppress this contamination. The first kind of filter used by AERA was the Median one, based on the Fast Fourier Transform (FFT) technique. The second one, which is currently in use, is the infinite impulse response (IIR) notch filter. The proposed new filter is a finite impulse response (FIR) filter based on a linear prediction (LP). A periodic contamination hidden in a registered signal (digitized in the ADC) can be extracted and next subtracted to make signal cleaner. The FIR filter requires a calculation of n=32, 64 or even 128 coefficients (dependent on a required speed or accuracy) by solving of n linear equations with coefficients built from the covariance Toeplitz matrix. This matrix can be solved by the Levinson recursion, which is much faster than the Gauss procedure. The filter has been already tested in the real AERA radio stations on Argentinean pampas with a very successful results. The linear equations were solved either in the virtual soft-core NIOSR processor (implemented in the FPGA chip as a net of logic elements) or in the external Voipac PXA270M ARM processor. The NIOS processor is relatively slow (50 MHz internal clock), calculations performed in an external processor consume a significant amount of time for data exchange between the FPGA and the processor. Test showed a very good efficiency of the RFI suppression for stationary (long-term) contaminations. However, we observed a short-time contaminations, which could not be suppressed either by the IIR-notch filter or by the FIR filter based on the linear predictions. For the LP FIR filter the refreshment time of the filter coefficients was to long and filter did not keep up with the changes of a contamination structure, mainly due to a long calculation time in a slow processors. We propose to use the Cyclone V SE chip with embedded micro-controller operating with 925 MHz internal clock to significantly reduce a refreshment time of the FIR coefficients. The lab results are promising. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinemetrics Q330M+ Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Q330M+, manufactured by Quanterra, a division of Kinemetrics Inc. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, input impedance, power consumption, self noise, dynamic range, system noise, relative transfer function, analog bandwidth, modified noise power ratio, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Q330M+ provides six channels of 24 bit digitization, all of which may be transmitted utilizing CD1.1 protocol, at multiple sample rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Monitoring and Control in the ANL METL Facility Using an Engineering Digital Twin

The potential benefits of using an engineering digital twin to achieve greater autonomy for monitoring and control functions in advanced reactors was investigated for the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The METL sodium purification system served as a representative system as it requires significant human in-the-loop interaction to accomplish its design function. The objective was to demonstrate how real-time operation could be automated while preserving oversight of the operator for ensuring that the system design functions are met. A digital twin model of the purification system was developed for both the cold trap purification loop and plugging meter diagnostic loop using information from the METL piping and instrumentation diagram (P&ID). Automated monitoring and diagnosis of component degradation in the METL facility was demonstrated in tests using the PRO-AID health monitoring software with the digital twin model incorporated in the library of components. Component failures were introduced and were successfully diagnosed in real time. These tests serve to demonstrate an advanced monitoring capability able to differentiate sensor degradation from component degradation, to generate a rank ordering of probabilities of different failure mechanisms that serves to circumvent the false alarm problem with current anomaly detection methods, and how facility monitoring can be transformed from anomaly detection to identification of a specific fault. Automated control of the purification system was demonstrated through simulations that exercised a model predictive controller designed using the digital twin model. Results of these simulations compared favorably with experimental data showing very good reference tracking response with negligible overshoot. In conclusion, these pilot tests and simulations successfully demonstrated the use of a digital twin for improved automation of monitoring and control. It was shown how the digital twin enables switching between control modes from cold trap operation where impurities are removed to plugging meter operation where impurity concentrations are measured.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A digital flight control system verification laboratory

A NASA/FAA program has been established for the verification and validation of digital flight control systems (DFCS), with the primary objective being the development and analysis of automated verification tools. In order to enhance the capabilities, effectiveness, and ease of using the test environment, software verification tools can be applied. Tool design includes a static analyzer, an assertion generator, a symbolic executor, a dynamic analysis instrument, and an automated documentation generator. Static and dynamic tools are integrated with error detection capabilities, resulting in a facility which analyzes a representative testbed of DFCS software. Future investigations will ensue particularly in the areas of increase in the number of software test tools, and a cost effectiveness assessment.

De Feo, P.↗

Subsurface Sampling and Sensing Using Burrowing Moles

Finding evidence for life on Mars will likely require accessing the subsurface since the Martian surface is both hostile to life and to preservation of biosignatures due to the cold dry conditions, the strong W environment, and the presence of strong oxidants. Systems are needed to probe beneath the sun and oxidant baked surface of Mars and return samples to the surface for analysis or to bring the instrument sensing underground. Recognizing this need, the European Space Agency incorporated a small subsurface penetrometer or Mole onto the Beagle 2 Mars lander. Had the 2003 landing been successful, the Mole would have collected samples from 1-1.5 m depth and delivered them to an organic analysis instrument on the surface. The de- vice called the Planetary Underground Tool (PLUTO), also measured soil mechanical and thermophysical properties. Constrained by the small mass and volume allowance of the Beagle lander, the PLUTO mole was a slender cylinder only 2 cm diameter and 28 cm long equipped with a small sampling device designed to collect samples and bring them to the surface for analysis by other instrument. The mass of the entire system including deployment mechanism and tether was 1/2 kg. sensor package underground to make in situ measurements. The Mars Underground Mole (MUM) is a larger Mole based on the PLUTO design but incorporating light collection optics that interface to a fiber optic cable in the tether that transmits light to a combined stimulated emission Raman Spectrometer and Short Wave Infrared (SWIR) reflectance Spectrometer with sensitivity from 0.7 to 2.5 micrometers. This instrument is called the Dual Spectral Sensor and uses a Digital Array Scanning Interferometer as the sensor technology, a type of fourier transform interferometer that uses fixed element prisms and thus is highly rugged compared to a Michaelson interferometer. Due to the size limitations of an on-Mole instrument compartment, and the availability of a tether, the sensor head, light sources, and control electronics for the instrument are on the surface. The DSS sensor is capable of sensing a wide range of minerals relevant to Mars Astrobiology objectives including hydrated minerals, clays, carbonates, sulfates, and ice. Additionally, Raman spectroscopy is effective for detecting organics. The MUM is designed to achieve a maximum depth of penetration of 5 m in Mars regolith and can be repeatedly deployed and retrieved. The ability to perform repeated sampling, combined with the low mass and power requirements, means that Moles could be incorporated into a rover mission as well as used on a stationary platform. The Mole mechanism is a pointed slender cylinder that advances into soil by way of an internal sliding hammer mechanism. Part of the energy released by the spring-loaded hammer with each shock is transferred to the Mole casing and from there to the soil, resulting in penetration by displacing and compressing the surrounding soil. A backwards-directed impulse as a re- action to each forward shock is transferred via a suppressor mass against a second weaker spring allowing forward motion without requiring reactive forces provided by the lander. The Mole tip can be opened to collect soil samples. The Mole casing is tethered to a supporting mechanism that supplies power. Components supporting the Mole on the surface include a launch tube, tether reel and winch for pulling in tether, in addition to the tether itself.

Stoker, C. R.↗

AERCam Autonomy: Intelligent Software Architecture for Robotic Free Flying Nanosatellite Inspection Vehicles

The NASA Johnson Space Center has developed a nanosatellite-class Free Flyer intended for future external inspection and remote viewing of human spacecraft. The Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam) technology demonstration unit has been integrated into the approximate form and function of a flight system. The spherical Mini AERCam Free Flyer is 7.5 inches in diameter and weighs approximately 10 pounds, yet it incorporates significant additional capabilities compared to the 35-pound, 14-inch diameter AERCam Sprint that flew as a Shuttle flight experiment in 1997. Mini AERCam hosts a full suite of miniaturized avionics, instrumentation, communications, navigation, power, propulsion, and imaging subsystems, including digital video cameras and a high resolution still image camera. The vehicle is designed for either remotely piloted operations or supervised autonomous operations, including automatic stationkeeping, point-to-point maneuvering, and waypoint tracking. The Mini AERCam Free Flyer is accompanied by a sophisticated control station for command and control, as well as a docking system for automated deployment, docking, and recharge at a parent spacecraft. Free Flyer functional testing has been conducted successfully on both an airbearing table and in a six-degree-of-freedom closed-loop orbital simulation with avionics hardware in the loop. Mini AERCam aims to provide beneficial on-orbit views that cannot be obtained from fixed cameras, cameras on robotic manipulators, or cameras carried by crewmembers during extravehicular activities (EVA s). On Shuttle or International Space Station (ISS), for example, Mini AERCam could support external robotic operations by supplying orthogonal views to the intravehicular activity (IVA) robotic operator, supply views of EVA operations to IVA and/or ground crews monitoring the EVA, and carry out independent visual inspections of areas of interest around the spacecraft. To enable these future benefits with minimal impact on IVA operators and ground controllers, the Mini AERCam system architecture incorporates intelligent systems attributes that support various autonomous capabilities. 1) A robust command sequencer enables task-level command scripting. Command scripting is employed for operations such as automatic inspection scans over a region of interest, and operator-hands-off automated docking. 2) A system manager built on the same expert-system software as the command sequencer provides detection and smart-response capability for potential system-level anomalies, like loss of communications between the Free Flyer and control station. 3) An AERCam dynamics manager provides nominal and off-nominal management of guidance, navigation, and control (GN&C) functions. It is employed for safe trajectory monitoring, contingency maneuvering, and related roles. This paper will describe these architectural components of Mini AERCam autonomy, as well as the interaction of these elements with a human operator during supervised autonomous control.

Fredrickson, Steven E.↗

UWB delay and multiply receiver

An ultra-wideband (UWB) delay and multiply receiver is formed of a receive antenna; a variable gain attenuator connected to the receive antenna; a signal splitter connected to the variable gain attenuator; a multiplier having one input connected to an undelayed signal from the signal splitter and another input connected to a delayed signal from the signal splitter, the delay between the splitter signals being equal to the spacing between pulses from a transmitter whose pulses are being received by the receive antenna; a peak detection circuit connected to the output of the multiplier and connected to the variable gain attenuator to control the variable gain attenuator to maintain a constant amplitude output from the multiplier; and a digital output circuit connected to the output of the multiplier.

47 OTHER INSTRUMENTATION↗

Radiation hardened successive-approximation ADC with error detection circuits - 238

For several decades, radiation-hardened-by-design (RHBD) techniques have been developed to meet the design requirements of irradiating environment in nuclear power plants. Improvements on the circuit side for radiation sensors in performance, chip size, and radiation hardening ability have been adopted in current plant systems; however, next generation reactors and/or preparation for severe events in existing reactors require advanced circuit structures that can provide relatively long viability in harsh conditions. In order to maintain performances of electronics in high radiating environments, we propose to develop a small-area, low resource-overhead data-converter architecture that is immune to radiation impact events, an architecture that includes three kinds of novel radiation-hardened (rad-hard) designs for each analog and digital circuit in an ADC structure: a) error detectable tri-state buffer for flip flop against DSET, b) error detection storage in flip flop against SEU, and c) analog algorithm for the analog parts of an SAR ADC. The novel ADC architecture including the three RHBD techniques was implemented in a standard 180 nm CMOS technology with a 1.8 V supply voltage. Simulation results show that the techniques can successfully recognize errors induced by radiation impact events. The static power consumption was 123 {mu}W with the sampling rate 36 MS/s and resolution of 8 bits. The performances could be highly advanced under fine-tune designs. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A sub-picosecond digitally-controlled phase delay

The use of precision timing measurements will be a major tool at the HL-LHC, where it will be used to suppress pile-up and to search for long-lived particles. To control a reference clock with sub-picosecond accuracy, we have fabricated in the TSMC 65 nm process a digitally controlled phase shifter. It is composed of a chain of 66 cells, each with a digitally controlled planar wave guide with either a short or long delay. With this a reference clock’s phase can be controlled to a precision of 200 fs with dynamic range of 12 ps.

Instruments & Instrumentation↗

Guralp Affinity Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Affinity, manufactured by Guralp Systems. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, power, self-noise, dynamic range, system noise, relative transfer function, modified noise power ratio, analog bandwidth, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Affinity provides eight, rather the typical six, channels of 24 bit high sample rate digitization, all of which may be transmitted utilizing the CD1.1 protocol, at multiple sample rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward biologically inspired self healing digital embedded devices: BIO-SymPle - 388

One of the more interesting concepts being postulated for next gen power plants, is the notion of highly resilient and survivable I and C systems. While resilience and survivability are 'cross system attributes', resilience and robustness will rely on highly robust and fault resilient devices as a foundation. This paper presents a new self-healing digital I and C architecture inspired by the operation of two biological concepts: human immune system and embryonic stem cells. The purpose of this research is look at different bio-inspired paradigms for organizing system functions so that they become inherently resilient due to device organization and behaviors. Our current proposed approach (called BIO-SymPle) is organized in two levels: critical service layer, which is providing the intended service of critical application, and healing layer, that supervises the operation of all repair mechanisms. To facilitate coordination, organized behavior among cells we employ network-based topology structures which is comprised of four active cells, four pre-generated redundant cells, and one embryonic stem cell. Collectively, the ensemble represents the building block that executes the local functionality based on the expression for DNA genetic codes stored inside each cell. The four bio-operational active cells are protected by their neighboring spare cells that imitate how white blood cells are distributed around the antigens in their locations. Ultimately, the proposed multi-layer architecture is able to cover a significant number of coincident faults and we believe architectures like BIO-SymPLe can positively impact the next generation digital I and C system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microreactor Program Technology Maturation MACS system reports

This submission contains several reports associated with the DOE Microreactor Program Technology Maturation MACS system. These include milestone reports: M3AT-24IN0804031-Optimized MACS architecture M3AT-24IN0804033-Light and temp sensor integration M4AT-23IN0804055-Update Microreactor Automated Control System (MACS) hardware based on input from demonstration M2AT-23IN0804054-Demonstrate actuation of control system using Microreactor Automated Control System (MACS)

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

The Meteorological Measurement System on the NASA ER-2 aircraft

A Meteorological Measurement System (MMS) was designed and installed on one of the NASA high-altitude ER-2 aircraft (NASA 706). The MMS provides in situ measurements of free-stream pressure (+ or - 0.3 mb), temperature (+ or - 0.3 C), and wind vector (+ or - 1 m/s). It incorporates a high-resolution inertial navigation system specially configured for scientific applications, a radome differential pressure system for measurements of the airflow angles, and a compact, computer-controlled data acquisition system to sample, process and store 45 variables on tape and on disk. The MMS hardware and software development is described, and resolution and accuracy of the instrumentation discussed. Custom software facilitates preflight system checkout, inflight data acquisition, and fast postflight data download. It accommodates various modes of MMS data: analog and digital, serial and parallel, and synchronous and asynchronous. Flight results are presented to demonstrate the capability of the system.

Scott, Stan G.↗

Diode-Laser-Based Spectrometer for Sensing Gases

A diode-laser-based spectrometer has been developed for measuring concentrations of gases and is intended particularly for use in analyzing and monitoring combustion processes under microgravitational conditions in a drop tower or a spacecraft. This instrument is also well suited for use on Earth in combustion experiments and for such related purposes as fire-safety monitoring and monitoring toxic and flammable gases in industrial settings. Of the gas-sensing spectrometers available prior to the development of this instrument, those that were sensitive enough for measuring the combustion gases of interest were too large, required critical optical alignments, used far too much electrical power, and were insufficiently rugged for use under the severe conditions of spacecraft launch and space flight. In contrast, the present instrument is compact, consumes relatively little power, and is rugged enough to withstand launch vibrations and space flight. In addition, this instrument is characterized by long-term stability, accuracy, and reliability. The diode laser in this spectrometer is operated in a wavelength-modulation mode. Different gases to be measured can be selected by changing modular laser units. The operation of the laser is controlled by customized, low-power electronic circuitry built around a digital signal-processor board. This customized circuitry also performs acquisition and analysis of data, controls communications, and manages errors.

Silver, Joel A.↗