Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Characterization of the Support and Drive System of the PETRA III APPLE Undulator

Helmholtzzentrum Berlin has built an APPLE II undulator for the storage ring PETRA III. The device has a total length of 5m and a minimum gap of 11mm. The high magnetic forces in particular in the inclined mode have been analyzed by means of finite element methods (FEM). Specific mechanic components such as flexible joints have been optimized to cope with the gap- and shift-dependent 3D-forces and a sophisticated control and drive system has been implemented. After completion of the device, detailed laser interferometer measurements for all operation modes have been performed. The data are compared to the FEM simulations.

43 PARTICLE ACCELERATORS↗

Design and Technical Aspects of a New in Vacuum Transfocator at ESRF Beamline ID11

A tunable X-Ray focusing apparatus based on compound refractive lenses (CRL), referred to as a transfocator, has been installed for monochromatic beam (IAT in air transfocator) two years ago in the second optics hutch at ID11 at the ESRF. By varying the number of lenses in the beam, the energy focused and the focal length can be varied continuously throughout a large range of energies and distances.Based the success of the IAT, an in-vacuum transfocator (IVT) has now been built and installed at ID11.The aim of this poster is to describe and show the mechanical and technical solutions used to design and manufacture this new IVT.The IVT was installed last January in the first optics hutch at ID11. The IVT consists of nine water cooled cartridges containing 1, 2, 4, 8, 16, 32 Be lenses, and 32 and 64 Al lenses, and a protective aperture of Oe 900 {mu}m. The mechanical design is based on a system of pneumatically actuated cartridges with an auto positioning on two stainless steel rods. The vacuum vessel has translations and rotations perpendicular to the beam direction in order to align the axis of the cartridges with the x-ray beam.

43 PARTICLE ACCELERATORS↗

Real Time Tomography at the Swiss Light Source

The penetrating power of X-rays coupled with the high flux of 3rd generation synchrotron sources makes X-ray tomography to excel among fast imaging methods . To exploit this asset of synchrotron sources is the motivation for setting up an ultra-fast tomography endstation at the TOMCAT beamline. The state of the art instruments at synchrotron sources offer routinely a temporal resolution of tens of seconds in tomography. For a number of applications, for example biomedical studies, the relevant time scales (breathing, heartbeat) are rather in the range of 0.5-2 seconds. To overcome motion artifacts when imaging such systems a new ultra-fast tomographic data acquisition scheme is being developed at the TOMCAT beamline. We can acquire a full set of projections at sub-second timescale in monochromatic or white-beam configuration. We present a feasibility study with the ultimate aim to achieve sub-second temporal resolution in 3D without significant deterioration of the spatial resolution. For the first time, the 3D dynamics of the very early stages of a quickly aging liquid foam can be visualised with high quality and sufficiently large field of view.

43 PARTICLE ACCELERATORS↗

Range, resolution and power of THz systems for remote detection of concealed radioactive materials

This paper analyzes parameters required for realizing remote detection of a concealed source of ionizing radiation by observing the occurrence of breakdown in air by a focused wave beam. Production of free electrons and the free electron density in the absence/presence of additional sources of ionization are analyzed. The maximum electron density in the discharge and the time required for this density to return after the discharge back to its stationary level, are estimated. The optimal excess of the power density and the corresponding power level as the function of frequency are determined. It is shown that the optimal frequency of such systems ranges from 0.3 up to 0.8 THz. The paper also determines the range of such systems as the function of the source frequency and power and contains a brief analysis of available sources of microwave, millimeter-wave and THz radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background simulations and shielding calculations

Key improvements in the sensitivity of the underground particle astrophysics experiments can only be achieved if the radiation causing background events in detectors is well understood and proper measures are taken to suppress it. The background radiation arising from radioactivity and cosmic-ray muons is discussed here together with the methods of its suppression. Different shielding designs are considered to attenuate gamma-rays and neutrons coming from radioactivity in rock and lab walls. Purity of materials used in detector construction is analysed and the background event rates due to the presence of radioactive isotopes in detector components are discussed. Event rates in detectors caused by muon-induced neutrons with and without active veto systems are presented leading to the requirements for the depth of an underground laboratory and the efficiency of the veto system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation of a Ka band high power millimeter wave generator operated at low guiding magnetic field

An overmoded slow wave type Ka band generator is investigated experimentally to produce high power millimeter waves in this paper. The experiments were carried out at the TORCH-01 accelerator. The produced microwave frequency was measured by dispersive line method, and the power was estimated by integrating over the radiation pattern at far field. With relatively low guiding magnetic field of 0.8 T and diode voltage and beam current of 590 kV and 5.2 kA, respectively, a 33.56 GHz millimeter wave with an output power of 320 MW was generated, and the microwave mode was quasi-TM{sub 01} mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new nonlinear reconstruction method based on total variation regularization of neutron penumbral imaging

Neutron penumbral imaging is a significant diagnostic technique in laser-driven inertial confinement fusion experiment. It is very important to develop a new reconstruction method to improve the resolution of neutron penumbral imaging. A new nonlinear reconstruction method based on total variation (TV) regularization is proposed in this paper. A TV-norm is used as regularized term to construct a smoothing functional for penumbral image reconstruction in the new method, in this way, the problem of penumbral image reconstruction is transformed to the problem of a functional minimization. In addition, a fixed point iteration scheme is introduced to solve the problem of functional minimization. The numerical experimental results show that, compared to linear reconstruction method based on Wiener filter, the TV regularized nonlinear reconstruction method is beneficial to improve the quality of reconstructed image with better performance of noise smoothing and edge preserving. Meanwhile, it can also obtain the spatial resolution with 5 {mu}m which is higher than the Wiener method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Shielding Properties of Some Marbles in Turkey

Especially after development of technology, radiation started to be used in a large fields such as medicine, industry and energy. Using radiation in those fields bring hazardous effect of radiation into humancell. Thus radiation protection becomes important in physics. Although there are three ways for radiation protection, shielding of the radiation is the most commonly used method. Natural Stones such as marble is used as construction material especially in critical building and thus its radiation shielding capability should be determined.In this study, gamma ray shielding properties of some different types of marble mined in Turkey, have been measured using a NaI(Tl) scintillator detector. The measured results were also compared with the theoretical calculations XCOM.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modification of the collective Thomson scattering radiometer in the search for parametric decay on TEXTOR

Strong scattering of high-power millimeter waves at 140 GHz has been shown to take place in heating and current-drive experiments at TEXTOR when a tearing mode is present in the plasma. The scattering signal is at present supposed to be generated by the parametric decay instability. Here we describe the heterodyne detection system used to characterize the newly discovered signal measured at TEXTOR, and we present spectral shapes in which the signal can appear under different conditions. The radiation is collected by the receiver through a quasi-optical transmission line that is independent of the electron cyclotron resonance heating transmission line, and so the scattering geometry is variable. The signal is detected with 42 frequency channels ranging from 136 to 142 GHz. We demonstrate that the large signal does not originate from gyrotron spurious radiation. The measured signal agrees well with independent backscattering radiometer data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonstationary oscillation of gyrotron backward wave oscillators with cylindrical interaction structure

The nonstationary oscillation of the gyrotron backward wave oscillator (gyro-BWO) with cylindrical interaction structure was studied utilizing both steady-state analyses and time-dependent simulations. Comparisons of the numerical results reveal that the gyro-BWO becomes nonstationary when the trailing field structure completely forms due to the dephasing energetic electrons. The backward propagation of radiated waves with a lower resonant frequency from the trailing field structure interferes with the main internal feedback loop, thereby inducing the nonstationary oscillation of the gyro-BWO. The nonstationary gyro-BWO exhibits the same spectral pattern of modulated oscillations with a constant frequency separation between the central frequency and sidebands throughout the whole system. The frequency separation is found to be scaled with the square root of the maximum field amplitude, thus further demonstrating that the nonstationary oscillation of the gyro-BWO is associated with the beam-wave resonance detuning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel modification of Hall-type ion source (study and the first results)

We present the original approach to use plasma accelerators with closed electron drift (Hall-type ion sources), which, unlike traditional accelerators with metal and dielectric walls, have open walls and can be applied for creation cost effective low maintenance plasma devices based on plasma lens configuration for production of converging towards axis accelerated ion beams. The paper describes pilot sample of Hall-type plasma accelerator, the first experimental results, one-dimensional theoretical model, and exact analytical solutions following from it.

43 PARTICLE ACCELERATORS↗

A study of space charge induced non-linearity in the Single Line Of Sight camera

We report a new generation of gated x-ray detectors at the National Ignition Facility has brought faster, enhanced imaging capabilities. Their performance is currently limited by the amount of signal they can be operated with before space charge effects in their electron tube start to compromise their temporal and spatial response. We present a technique to characterize this phenomenon and apply it to a prototype of such systems, the Single Line Of Sight camera. Results of this characterization are used to benchmark Particle In Cell simulations of the electrons drifting inside the detector, which are found to well reproduce experimental data. These simulations are then employed to predict the optimum photon flux to the camera, with the goal to increase the quality of the images obtained on an experimental campaign while preventing the appearance of deleterious effects. They also offer some insight into some of the improvements that can be brought to the new pulse-dilation systems being built at Lawrence Livermore National Laboratory

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extension of the possibilities of a commercial digital camera in detecting spatial intensity distribution of laser radiation

Performance capabilities of commercial digital cameras are demonstrated by the example of a Canon EOS 400D camera in measuring and detecting spatial distributions of laser radiation intensity. It is shown that software extraction of linear data expands the linear dynamic range of the camera by a factor greater than 10, up to 58 dB. Basic measurement characteristics of the camera are obtained in the regime of linear data extraction: the radiometric function, deviation from linearity, dynamic range, temporal and spatial noises (both dark and those depending on the signal value). The parameters obtained correspond to those of technical measuring cameras. (measurement of laser radiation parameters)

42 ENGINEERING↗

Specific features of diffuse reflection of human face skin for laser and non-laser sources of visible and near-IR light

The specific features of diffuse reflection from different areas of human face skin for laser and non-laser sources of visible and near-IR light have been investigated to localise the closed-eye (eyelid) region. In the visible spectral range the reflection from the eyelid skin surface can be differentiated by measuring the slope of the spectral dependence of the effective optical density of skin in the wavelength range from 650 to 700nm. In the near-IR spectral range the reflectances of the skin surface at certain wavelengths, normalised to the forehead skin reflectance, can be used as a criterion for differentiating the eyelid skin. In this case, a maximum discrimination is obtained when measuring the skin reflectances at laser wavelengths of 1310 and 1470nm, which correspond to the spectral ranges of maximum and minimum water absorption. (optical technologies in biophysics and medicine)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE PROPERTIES OF X-RAY LUMINOUS YOUNG STELLAR OBJECTS IN THE NGC 1333 AND SERPENS EMBEDDED CLUSTERS

We present new Chandra X-ray data of the NGC 1333 embedded cluster and combine these data with existing Chandra data, Spitzer photometry, and ground-based spectroscopy of both the NGC 1333 and Serpens cloud core clusters to perform a detailed study of the X-ray properties of two of the nearest embedded clusters to the Sun. We first present new, deeper observations of NGC 1333 with Chandra ACIS-I and combine these with existing Spitzer observations of the region. In NGC 1333, a total of 95 cluster members are detected in X-rays of which 54 were previously identified in the Spitzer data. Of the Spitzer-identified sources, we detected 23% of the Class I protostars, 53% of the flat-spectrum sources, 52% of the Class II, and 50% of the transition disk young stellar objects (YSOs). Forty-one Class III members of the cluster are identified, bringing the total identified YSO population to 178. The X-ray luminosity functions (XLFs) of the NGC 1333 and Serpens clusters are compared to each other and the Orion Nebula Cluster (ONC). Based on a comparison of the XLFs of the Serpens and NGC 1333 clusters to the previously published ONC, we obtain a new distance for the Serpens cluster of 360{sup +22}{sub -13} pc. Using our previously published spectral types, effective temperatures, and bolometric luminosities, we analyze the dependence of the X-ray emission on the measured stellar properties. The X-ray luminosity was found to depend on the calculated bolometric luminosity as in previous studies of other clusters. We examine the dependence of L{sub X} on stellar surface area and effective temperature, and find that L{sub X} depends primarily on the stellar surface area. In the NGC 1333 cluster, the Class III sources have a somewhat higher X-ray luminosity for a given surface area. We also find evidence in NGC 1333 for a jump in the X-ray luminosity between spectral types of M0 and K7, we speculate that this may result from the presence of radiative zones in the K-stars. The gas column density versus extinction in the NGC 1333 parental molecular cloud was examined using the hydrogen column density determined from the X-ray absorption to the embedded stars and the K-band extinction measured to those stars. In NGC 1333, we find N{sub H} = 0.89 {+-} 0.13 x 10{sup 22} A{sub K} , this is lower than expected of the standard interstellar medium but similar to that found previously in the Serpens cloud core.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY AND GAMMA-RAY FLASHES FROM TYPE Ia SUPERNOVAE?

We investigate two potential mechanisms that will produce X-ray and gamma-ray flashes from Type Ia supernovae (SN-Ia). The first mechanism is the breakout of the thermonuclear burning front as it reaches the surface of the white dwarf (WD). The second mechanism is the interaction of the rapidly expanding envelope with material within an accretion disk in the progenitor system. Our study is based on the delayed detonation scenario because this can account for the majority of light curves, spectra, and statistical properties of 'Branch-normal' SN-Ia. Based on detailed radiation-hydro calculations which include nuclear networks, we find that both mechanisms produce brief flashes of high-energy radiation with peak luminosities of 10{sup 48}-10{sup 50} erg s{sup -1}. The breakout from the WD surface produces flashes with a rapid exponential decay by 3-4 orders of magnitude on timescales of a few tenths of a second and with most of the radiation in the X-ray and soft gamma-ray range. The shocks produced in gases in and around the binary will produce flashes with a characteristic duration of a few seconds with most of the radiation coming out as X-rays and gamma-rays. In both mechanisms, we expect a fast rise and slow decline and, after the peak, an evolution from hard to softer radiation due to adiabatic expansion. In many cases, flashes from both mechanisms will be superposed. The X- and gamma-ray visibility of an SN-Ia will depend strongly on self-absorption within the progenitor system, specifically on the properties of the accretion disk and its orientation toward the observer. Such X-ray and gamma-ray flashes could be detected as triggered events by gamma-ray burst (GRB) detectors on satellites, with events in current GRB catalogs. We have searched through the GRB catalogs (for the BATSE, HETE, and Swift experiments) for GRBs that occur at the extrapolated time of explosion and in the correct direction for known Type Ia supernovae with radial velocity of less than 3000 km s{sup -1}. For the Burst and Transient Source Experiment (BATSE) about 12.9 +- 3.6 nearby SNe Ia should have been detected, but only 0.8 +- 0.7 non-coincidental matches have been found. With the High Energy Transient Explorer (HETE) and Swift satellites, we expect to see 5.6 +- 1.3 SN-Ia flashes from known nearby SNe Ia but, yet, no SN-Ia flashes were detected. With the trigger thresholds for these experiments and the upper limits on the SN-Ia distances, we show that the bolometric peak luminosity of SN-Ia flashes must be less approx10{sup 46} erg s{sup -1}. Our observational limit is several orders-of-magnitude smaller than the peak luminosities predicted for both the early flashes. We attribute this difference to the absorption of the X- and gamma-rays by the accretion disk of large-scale height or common envelope that would be smothering the WD.

79 ASTRONOMY AND ASTROPHYSICS↗

THE FIRST DETECTION OF [O IV] FROM AN ULTRALUMINOUS X-RAY SOURCE WITH SPITZER. II. EVIDENCE FOR HIGH LUMINOSITY IN HOLMBERG II ULX

This is the second of two papers examining Spitzer Infrared Spectrograph observations of the ultraluminous X-ray source (ULX) in Holmberg II. Here, we perform detailed photoionization modeling of the infrared lines. Our analysis suggests that the luminosity and morphology of the [O IV] 25.89 mum emission line is consistent with photoionization by the soft X-ray and far ultraviolet (FUV) radiation from the accretion disk of the binary system and inconsistent with narrow beaming. We show that the emission nebula is matter-bounded both in the line-of-sight direction and to the east, and probably radiation-bounded to the west. A bolometric luminosity in excess of 10{sup 40} erg s{sup -1} would be needed to produce the measured [O IV] flux. We use modeling and previously published studies to conclude that shocks likely contribute very little, if at all, to the high-ionization line fluxes observed in the Holmberg II ULX. Additionally, we find that the spectral type of the companion star has a surprisingly strong effect on the predicted strength of the [O IV] emission. This finding could explain the origin of [O IV] in some starburst systems containing black hole binaries.

79 ASTRONOMY AND ASTROPHYSICS↗

OBSCURED GOODS ACTIVE GALACTIC NUCLEI AND THEIR HOST GALAXIES AT z < 1.25: THE SLOW BLACK HOLE GROWTH PHASE

We compute black hole masses and bolometric luminosities for 87 obscured active galactic nuclei (AGNs) in the redshift range 0.25 {<=} z {<=} 1.25, selected from the GOODS deep multi-wavelength survey fields via their X-ray emission. We fit the optical images and obtain morphological parameters for the host galaxy, separating the galaxy from its central point source, thereby obtaining a four-band optical spectral energy distribution (SED) for each active nucleus. We calculate bolometric luminosities for these AGNs by reddening a normalized mean SED of GOODS broad-line AGNs to match the observed central point-source SED of each obscured AGN. This estimate of L{sub bol} has a smaller spread than simple bolometric corrections to the X-ray luminosity or direct integration of the observed multi-wavelength SED, suggesting it is a better measure. We estimate central black hole masses from the bulge luminosities. The black hole masses span a wide range, 7 x 10{sup 6} M{sub sun} to 6 x 10{sup 9} M{sub sun}; the median black hole mass is 5 x 10{sup 8} M{sub sun}. The majority of these AGNs have L/L{sub Edd} {<=} 0.01, and we detect no significant evolution of the mean Eddington ratio to z = 1.25. This implies that the bulk of black hole growth in these obscured AGNs must have occurred at z {approx}> 1 and that we are observing these AGNs in a slow- or no-growth state.

79 ASTRONOMY AND ASTROPHYSICS↗