Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVACUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Characteristics of Shock-Induced Dust Flux from the Surface of Lead and Copper Samples under Pressure in the Shock Wave of 45–50 GPa with Unloading into Vacuum

The results of experimental studies of the shock-induced particle ejection (“dusting”) from a free rough (R{sub z} = 20) surface of lead and copper samples into an evacuated medium are presented. The experimental methods were based on different physical principles. To determine the size of particles by shadow laser-optical imaging more efficiently, a narrow strip was isolated in the center of the free surface of a sample from which an optically transparent stream of particles was ejected. The rest of the surface, substantially larger in size, ejected particles, parameters of which were reliably recorded using optical heterodyne interferometry detection, radiographic imaging, and piezoelectric techniques. This made it possible to obtain more reliable data on the particle size distribution, the velocity of the front of a particle flux, and the density (weight) distribution of the flow in the direction of its motion, necessary to refine the existing models and create more reliable models to describe the phenomenon. Using lead and copper samples, the material of which melts or does not melt under shock wave loading in selected close conditions (amplitude of the shock wave and roughness of the free surface), made it possible to clearly demonstrate the effect of melting on the qualitative pattern and quantitative characteristics of the shock-induced dusting process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Prompt quality monitoring of InSe and GaSe semiconductor crystals by the nuclear quadrupole resonance technique

To determine the quality of layer-structured semiconductor single crystals, the nuclear quadrupole resonance technique with successive scanning of the entire sample volume and assessment of the structural quality on the basis of the observed spectra is used. The proposed method is appropriate in the case of InSe, GaSe and GaAs ingots grown in evacuated cells by the Bridgman technique and can be used repeatedly in subsequent technological procedures with no operator access to the material. To provide scanning within a limited region of the sample and to ensure efficient interaction of the high-frequency field with the crystal, excitation and detection of the nuclear-spin-induction signal is implemented by the saddle-shaped transceiver coil of the nuclear quadrupole resonance spectrometer.

36 MATERIALS SCIENCE↗

Structure of thermoelectric films of higher manganese silicide on silicon according to electron microscopy data

The structural features of higher manganese-silicide films obtained by the diffusion doping of single-crystal silicon substrates with manganese vapor in a sealed cell and a flow-through quartz reactor with continuous pumping are comparatively analyzed. Scanning electron microscopy and high-resolution transmission electron microscopy show that a single-phase textured film of higher manganese silicide is formed in the evacuated cell. A change in the growth conditions from steady (cell) to quasi-steady-state (reactor) leads to the formation of polycrystalline islands of higher manganese silicide with nanoscale inclusions of the manganese- monosilicide phase.

36 MATERIALS SCIENCE↗

PlanetSense: A Real-time Streaming and Spatio-temporal Analytics Platform for Gathering Geo-spatial Intelligence from Open Source Data

Geospatial intelligence has traditionally relied on the use of archived and unvarying data for planning and exploration purposes. In consequence, the tools and methods that are architected to provide insight and generate projections only rely on such datasets. Albeit, if this approach has proven effective in several cases, such as land use identification and route mapping, it has severely restricted the ability of researchers to inculcate current information in their work. This approach is inadequate in scenarios requiring real-time information to act and to adjust in ever changing dynamic environments, such as evacuation and rescue missions. In this work, we propose PlanetSense, a platform for geospatial intelligence that is built to harness the existing power of archived data and add to that, the dynamics of real-time streams, seamlessly integrated with sophisticated data mining algorithms and analytics tools for generating operational intelligence on the fly. The platform has four main components – i) GeoData Cloud – a data architecture for storing and managing disparate datasets; ii) Mechanism to harvest real-time streaming data; iii) Data analytics framework; iv) Presentation and visualization through web interface and RESTful services. Using two case studies, we underpin the necessity of our platform in modeling ambient population and building occupancy at scale.

big data architecture↗

An agent-based deployment decision-support system for electric vehicle services

METS-R ADDSEVS simulator is a high fidelity, parallel, agent-based evacuation simulator for multi-modal energy-optimal trip scheduling in real-time (METS-R) at transportation hubs. It consists of two modules. The first one is the traffic simulator module; the second one is the high-performance computing (HPC) module. More details can be found at https://umnilab.github.io/METS-R_doc/.

Lei, Zengxiang↗

Modeling Hospitals’ Adaptive Capacity during a Loss of Infrastructure Services

Resilience in hospitals ‐ their ability to withstand, adapt to, and rapidly recover from disruptive events ‐ is vital to their role as part of national critical infrastructure. This paper presents a model to provide planning guidance to decision makers about how to make hospitals more resilient against possible disruption scenarios. This model represents a hospital’s adaptive capacities that are leveraged to care for patients during loss of infrastructure services (power, water, etc.). The model is an optimization that reallocates and substitutes resources to keep patients in a high care state or allocates resources to allow evacuation if necessary. An illustrative example demonstrates how the model might be used in practice.

Vugrin, Eric D.↗

Tritium release from SS316 under vacuum condition

The plasma facing surface of the ITER vacuum vessel, partly made of low carbon austenitic stainless steel type 316L, will incorporate tritium during machine operation. In this paper the kinetics of tritium release from stainless steel type 316 into vacuum and into a noble gas stream are compared and modelled. Type 316 stainless steel specimens loaded with tritium either by exposure to 1.2 kPa HT at 573 K or submersion into liquid HTO at 298 K showed characteristic thin surface layers trapping tritium in concentrations far higher than those determined in the bulk. The evolution of the tritium depth profile in the bulk during heating under vacuum was non-discernible from that of tritium liberated into a stream of argon. Only the relative amount of the two released tritium-species, i.e. HT or HTO, was different. Temperature-dependent depth profiles could be predicted with a one-dimensional diffusion model. Diffusion coefficients derived from fitting of the tritium release into an evacuated vessel or a stream of argon were found to be (1.4 ± 1.0)*10{sup -7} and (1.3 ± 0.9)*10{sup -9} cm{sup 2}/s at 573 and 423 K, respectively. Polished surfaces on type SS316 stainless steel inhibit considerably the thermal release rate of tritium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Kriging based spatiotemporal approach for traffic volume data imputation

Along with the rapid development of Intelligent Transportation Systems, traffic data collection technologies have progressed fast. The emergence of innovative data collection technologies such as remote traffic microwave sensor, Bluetooth sensor, GPS-based floating car method, and automated license plate recognition, has significantly increased the variety and volume of traffic data. Despite the development of these technologies, the missing data issue is still a problem that poses great challenge for data based applications such as traffic forecasting, real-time incident detection, dynamic route guidance, and massive evacuation optimization. A thorough literature review suggests most current imputation models either focus on the temporal nature of the traffic data and fail to consider the spatial information of neighboring locations or assume the data follow a certain distribution. These two issues reduce the imputation accuracy and limit the use of the corresponding imputation methods respectively. As a result, this paper presents a Kriging based data imputation approach that is able to fully utilize the spatiotemporal correlation in the traffic data and that does not assume the data follow any distribution. A set of scenarios with different missing rates are used to evaluate the performance of the proposed method. The performance of the proposed method was compared with that of two other widely used methods, historical average and K-nearest neighborhood. Comparison results indicate that the proposed method has the highest imputation accuracy and is more flexible compared to other methods.

Science & Technology - Other Topics↗

Occupational Experience Effects on Physiological and Perceptual Responses of Common Soldiering Tasks

Abstract Cohen BS, Redmond JE, Haven CC, Foulis SA, Canino MC, Frykman PN, Sharp MA. Occupational Experience Effects on Physiological and Perceptual Responses of Common Soldiering Tasks. J Strength Cond Res 37(4): 894–901, 2023—This study measured the impact of occupational experience (i.e., time spent deployed, in military service, and in job and task performance frequency in training, deployment, and study practice) on the physiological (heart rate [HR] and oxygen consumption [VO 2 ]) and perceptual (rate of perceived exertion [RPE]) responses to performance of critical physically demanding tasks (CPDTs). Five CPDTs (road march, build a fighting position, move under fire, evacuate a casualty, and drag a casualty to safety), common to all soldiers, were performed by 237 active duty soldiers. Linear regression models examined the association between measures of experience and physiological and perceptual performance responses to task demands. The level of significance was adjusted for multiple comparisons and set at ρ ≤ 0.0125 for this study. Significant and notable effect sizes included the impact of time spent deployed on the physiological measures of the road march (PostHR F = 24.84, p < 0.0001, β=-9.65), sandbag fill (PostHR F = 8.26, p = 0.005, β = −2.83), and sandbag carry (MeanHR F = 7.51, p = 0.007, β = −1.12; PostHR F = 7.35, p = 0.007, β = −0.87). For the road march task, there was a nearly 10 bpm decrease in postperformance HR for every year spent deployed. Road march, sandbag fill, and sandbag carry tasks PostHRs were also notably negatively associated with the experience measures of time in their MOS (job and time in military service but not for other physiological and perceptual responses, including VO 2 and RPE. Frequency of task performance in training, deployment, and study practice was not meaningfully associated with experience. The results suggest that increasing task familiarization through on-the-job occupational operational experience may result in greater proficiency and reduced physiological effort.

Sport Sciences↗

Modeling Longitudinal Dynamics in the Fermilab Booster Synchrotron

The PIP-II project will replace the existing 400 MeV linac with a new, CW-capable, 800 MeV superconducting one. With respect to current operations, a 50% increase in beam intensity in the rapid cycling Booster synchrotron is expected. Booster batches are combined in the Recycler ring; this process limits the allowed longitudinal emittance of the extracted Booster beam. To suppress eddy currents, the Booster has no beam pipe; magnets are evacuated, exposing the beam to core laminations and this has a substantial impact on the longitudinal impedance. Noticeable longitudinal emittance growth is already observed at transition crossing. Operation at higher intensity will likely necessitate mitigation measures. We describe systematic efforts to construct a predictive model for current operating conditions. A longitudinal only code including a laminated wall impedance model, space charge effects, and feedback loops is developed. Parameter validation is performed using detailed measurements of relevant beam, rf and control parameters. An attempt is made to benchmark the code at operationally favorable machine settings.

43 PARTICLE ACCELERATORS↗

RF AND MECHANICAL DESIGN OF A 915 MHz SRF CAVITY FOR CONDUCTION-COOLED CRYOMODULES

Conduction-cooled SRF niobium cavities are being developed for use in compact, continuous-wave electron linear accelerators for a variety of industrial applications. A 915MHz two-cell cavity has been designed to achieve an energy gain of 3.5 MeV. The design of the cell shape aims at minimizing the peak surface magnetic field. Field flatness is achieved by adjusting the length of the outer end half-cells. The higher-order mode analysis shows that absorbers are not required for a moderate beam current of 5 mA. One of the beam tubes has two side-ports for insertion of coaxial fundamental power couplers. The mechanical design and analysis were done to maintain a stress near or less than 15.5 MPa for all anticipated loading conditions. This is half the measured yield strength and is to provide relief from creep when cavity is evacuated and stored with outside atmospheric pressure.

Ciovati, Gianluigi↗

Calorimetric study of skutterudite (CoAs2.92) and heazlewoodite (Ni3S2)

Abstract Nickel and cobalt arsenides, sulfarsenides, and sulfides occur in many hydrothermal ore deposits, but their thermodynamic properties are not well known, in some cases not known at all. In this work, we determined a full set of thermodynamic properties for heazlewoodite and skutterudite. Both phases were synthesized in evacuated silica tubes at elevated temperatures, and electron microprobe analyses gave their compositions as Ni3S2 and CoAs2.92, respectively. Enthalpies of formation were measured by high-temperature oxide-melt solution calorimetry. The reference phases were pure elements, thus eliminating any systematic errors related to such phases. The enthalpies of formation at T = 298.15 K and P = 105 Pa are –216.0 ± 8.4(2σ) and –88.2 ± 6.1 kJ·mol−1 for Ni3S2 and CoAs2.92, respectively. Entropies were calculated from low-temperature heat capacity (CP) data from relaxation (PPMS) calorimetry and are 133.8 ± 1.6 and 106.4 ± 1.3 J·mol–1·K–1, respectively. The calculated Gibbs free energies of formation are –210.0 ± 8.4 and –79.9 ± 6.2 kJ·mol−1 for Ni3S2 and CoAs2.92, respectively. The PPMS CP data, together with a set of differential scanning calorimetry measurements, were used to derive CP polynomials up to 700 K with the Kieffer model based on previously published frequencies of acoustic and optic modes. Equilibrium constants for selected reactions with an aqueous phase were calculated up to 700 K. Geochemical modeling in these systems, however, should await until more reliable data for other phases from the system Co-Ni-As-S are available.

Geochemistry & Geophysics↗

R&D ERL: Vacuum

The ERL Vacuum systems are depicted in a figure. ERL has eight vacuum volumes with various sets of requirements. A summary of vacuum related requirements is provided in a table. Five of the eight volumes comprise the electron beamline. They are the 5-cell Superconducting RF Cavity, Superconducting e-gun, injection, loop and beam dump. Two vacuum regions are the individual cryostats insulating the 5-cell Superconducting RF Cavity and the Superconducting e-gun structures. The last ERL vacuum volume not shown in the schematic is the laser transport line. The beamline vacuum regions are separated by electropneumatic gate valves. The beam dump is common with loop beamline but is considered a separate volume due to geometry and requirements. Vacuum in the 5-cell SRF cavity is maintained in the {approx}10{sup -9} torr range at room temperature by two 20 l/s ion pumps and in the e-gun SRF cavity by one 60 l/s ion pump. Vacuum in the SRF cavities operated at 2{sup o}K is reduced to low 10{sup -11} torr via cryopumping of the cavity walls. The cathode of the e-gun must be protected from poisoning, which can occur if vacuum adjacent to the e-gun in the injection line exceeds 10-11 torr range in the injection warm beamline near the e-gun exit. The vacuum requirements for beam operation in the loop and beam dump are 10-9 torr range. The beamlines are evacuated from atmospheric pressure to high vacuum level with a particulate free, oil free turbomolecular pumping cart. 25 l/s shielded ion pumps distributed throughout the beamlines maintain the vacuum requirement. Due to the more demanding vacuum requirement of the injection beamline proximate to the e-gun, a vacuum bakeout of the injection beamline is required. In addition, two 200 l/s diode ion pumps and supplemental pumping provided by titanium sublimation pumps are installed in the injection line just beyond the exit of the e-gun. Due to expected gas load a similar pumping arrangement is planned for the beam dump. The cryostat vacuum thermally insulating the SRF cavities need only reduce the convective heat load such that heat loss is primarily radiation through several layers of multi-layer insulation and conductive end-losses which are contained by 5{sup o}K thermal transitions. Prior to cool down rough vacuum {approx}10{sup -5} torr range is established and maintained by a dedicated turbomolecular pump station. Cryopumping by the cold mass and heat shields reduces the insulating vacuum to 10{sup -7} torr range after cool down.

43 PARTICLE ACCELERATORS↗

Envisioning an Ecologically Sustainable Campus At New England College

Appropriation funding for our project Ecologically Sustainable Campus - New England College (NH). 67.09. supported five environmental initiatives: (1) a wood pellet boiler for our Science Building, (2) solar hot water panels and systems for five campus buildings, (3) campus-wide energy lighting efficiency project, (4) new efficiency boiler system in Colby Residence Hall, and (5) energy efficient lighting system for the new artificial athletic turf field. (1) New England College purchased and installed a new wood pellet boiler in the Science Building. This new boiler serves as the primary heating source for this building. Our boiler was purchased through New England Wood Pellet, LLC, located in Jaffrey, New Hampshire. The boiler selected was a Swebo, P500. 300KW wood pellet boiler. The primary goals, objectives, and outcomes of this initiative include the installation of a wood pellet boiler system that is environmentally friendly, highly efficient, and represents a sustainable and renewable resource for New England College. This project was completed on December 15, 2010. (2) New England College purchased and installed solar hot water panels and systems for the Science Building, the Simon Center (student center), the H. Raymond Danforth Library, Gilmore Dining Hall, and Bridges Gymnasium. The College worked with Granite State Plumbing & Heating, LLC, located in Weare, New Hampshire on this project. The solar panels are manufactured by Heat Transfer; the product is Heat Transfer 30-tube collector panels (Evacuated Tube Type) with stainless steel hardware. The interior equipment includes Super Stor Ultra stainless steel super insulated storage tank, Taco 009 Bronze circulator pump, Solar Relay Control Pack, and a Taco Thermal Expansion Tank. The primary goals, objectives, and outcomes of this initiative will allow the College to utilize the sun as an energy resource. These solar hot water panels and systems will alleviate our dependency on fossil fuel as our primary fuel resource and provide a reliable energy source that supplies the hot water needs for sanitation, dishwashing at our dining facilities, and shower facilities for our athletes. This project initiative was completed on June 30, 2010. (3) New England College has completed energy efficiency lighting projects throughout campus, which included upgrades and new systems throughout our buildings. This project also installed efficiency controls for the Lee Clement Arena and refrigeration equipment in the Gilmore Dining Hall. The College worked with Atlantic Energy Solutions, located in Foxboro, Massachusetts on our 50/50 energy efficiency lighting project and campus-wide audit. The actual implementation of the project was completed by D. Poole Electrical Services, located in Center Barnstead, New Hampshire. The primary goals, objectives, and outcomes of this initiative were to install energy efficient lighting systems throughout our campus buildings, which ultimately will provide New England College with a more efficient way to manage and control its energy use. This project initiative was completed on February 15, 2010. (4) New England College purchased and installed a high efficiency and clean burning system for the Colby Residence Hall, which is the primary housing for our freshman. We purchased and installed two Buderus Boilers, model number G515/10 with two Riello Burners, model number RL 38/2. The College worked with Granite State Plumbing & Heating, LLS, located in Weare, New Hampshire on the installation of this high efficiency and clean burning system for the Colby Residence Hall. The primary goals, objectives, and outcomes for this initiative included the installation of a designed system of two boilers to provide redundancy for backup measures. This new system will provide New England College the flexibility to utilize just one smaller boiler to provide heat and hot water during non-peak periods thus continued reduction in energy use and our carbon footprint. This project initiative was completed on September 18, 2009. (5) New England College purchased and installed energy efficient lighting for our new artificial athletic turf field. The College selected Light-Structure Green lighting systems and worked with Musco Lighting, located in Oskaloosa. Iowa. The primary goals, objectives, and outcomes of this initiative were to install innovative lighting systems that significantly reduce energy costs and provide a high level of efficiency, resulting in overall utility savings to the College. This lighting technology combines the energy efficient equipment along with a focused lighting objective (field playing surface) to reduce the number of lighting heads needed to illuminate the playing surface to NCAA standards while reducing energy consumption by 50%. This project was completed on October 15, 2009.

09 BIOMASS FUELS↗

APPLICATION OF VACUUM SALT DISTILLATION TECHNOLOGY FOR THE REMOVAL OF FLUORIDE

Vacuum distillation of chloride salts from plutonium oxide (PuO{sub 2}) and simulant PuO{sub 2} has been previously demonstrated at Department of Energy (DOE) sites using kilogram quantities of chloride salt. The apparatus for vacuum distillation contains a zone heated using a furnace and a zone actively cooled using either recirculated water or compressed air. During a vacuum distillation operation, a sample boat containing the feed material is placed into the apparatus while it is cool, and the system is sealed. The system is evacuated using a vacuum pump. Once a sufficient vacuum is attained, heating begins. Volatile salts distill from the heated zone to the cooled zone where they condense, leaving behind the non-volatile materials in the feed boat. The application of vacuum salt distillation (VSD) is of interest to the HB-Line Facility and the MOX Fuel Fabrication Facility (MFFF) at the Savannah River Site (SRS). Both facilities are involved in efforts to disposition excess fissile materials. Many of these materials contain chloride and fluoride salt concentrations which make them unsuitable for dissolution without prior removal of the chloride and fluoride salts. Between September 2009 and January 2011, the Savannah River National Laboratory (SRNL) and HB-Line designed, developed, tested, and successfully deployed a system for the distillation of chloride salts. Subsequent efforts are attempting to adapt the technology for the removal of fluoride. Fluoride salts of interest are less-volatile than the corresponding chloride salts. Consequently, an alternate approach is required for the removal of fluoride without significantly increasing the operating temperature. HB-Line Engineering requested SRNL to evaluate and demonstrate the feasibility of an alternate approach using both non-radioactive simulants and plutonium-bearing materials. Whereas the earlier developments targeted the removal of sodium chloride (NaCl) and potassium chloride (KCl), the current activities are concerned with the removal of the halide ions associated with plutonium trifluoride (PuF{sub 3}), plutonium tetrafluoride (PuF{sub 4}), calcium fluoride (CaF{sub 2}), and calcium chloride (CaCl{sub 2}). This report discusses non-radioactive testing of small-scale and pilot-scale systems and radioactive testing of a small-scale system. Experiments focused on demonstrating the chemistry for halide removal and addressing the primary engineering questions associated with a change in the process chemistry.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EFFECT OF PORE SIZE ON TRAPPING ZINC VAPORS

A series of experiments were conducted to determine the effect of pore size on pumping efficiency and zinc vapor trapping efficiency. A simple pumping efficiency test was conducted for all five pore diameters where it was observed that evacuation times were adversely affected by reducing the pore size below 5 {micro}m. Common test conditions for the zinc trapping efficiency experiments were used. These conditions resulted in some variability, to ascribe different efficiencies to the filter media. However, the data suggest that there is no significant difference in trapping efficiency for filter media with pores from 0.2 to 20 {micro}m with a thickness of 0.065-inch. Consequently, the 20 {micro}m pore filter media that is currently used at SRS is a suitable filter material for to utilize for future extractions. There is evidence that smaller pore filter will adversely affect the pumping times for the TEF and little evidence to suggest that a smaller pore diameters have significant impact on the trapping efficiency.

99 GENERAL AND MISCELLANEOUS↗

Advanced Energy and Water Recovery Technology from Low Grade Waste Heat

The project has developed a nanoporous membrane based water vapor separation technology that can be used for recovering energy and water from low-temperature industrial waste gas streams with high moisture contents. This kind of exhaust stream is widely present in many industrial processes including the forest products and paper industry, food industry, chemical industry, cement industry, metal industry, and petroleum industry. The technology can recover not only the sensible heat but also high-purity water along with its considerable latent heat. Waste heats from such streams are considered very difficult to recover by conventional technology because of poor heat transfer performance of heat-exchanger type equipment at low temperature and moisture-related corrosion issues. During the one-year Concept Definition stage of the project, the goal was to prove the concept and technology in the laboratory and identify any issues that need to be addressed in future development of this technology. In this project, computational modeling and simulation have been conducted to investigate the performance of a nanoporous material based technology, transport membrane condenser (TMC), for waste heat and water recovery from low grade industrial flue gases. A series of theoretical and computational analyses have provided insight and support in advanced TMC design and experiments. Experimental study revealed condensation and convection through the porous membrane bundle was greatly improved over an impermeable tube bundle, because of the membrane capillary condensation mechanism and the continuous evacuation of the condensate film or droplets through the membrane pores. Convection Nusselt number in flue gas side for the porous membrane tube bundle is 50% to 80% higher than those for the impermeable stainless steel tube bundle. The condensation rates for the porous membrane tube bundle also increase 60% to 80%. Parametric study for the porous membrane tube bundle heat transfer performance was also done, which shows this heat transfer enhancement approach works well in a wide parameters range for typical flue gas conditions. Better understanding of condensing heat transfer mechanism for porous membrane heat transfer surfaces, shows higher condensation and heat transfer rates than non-permeable tubes, due to existence of the porous membrane walls. Laboratory testing has documented increased TMC performance with increased exhaust gas moisture content levels, which has exponentially increased potential markets for the product. The TMC technology can uniquely enhance waste heat recovery in tandem with water vapor recovery for many other industrial processes such as drying, wet and dry scrubber exhaust gases, dewatering, and water chilling. A new metallic substrate membrane tube development and molded TMC part fabrication method, provides an economical way to expand this technology for scaled up applications with less than 3 year payback expectation. A detailed market study shows a broad application area for this advanced waste heat and water recovery technology. A commercialization partner has been lined up to expand this technology to this big market. This research work led to new findings on the TMC working mechanism to improve its performance, better scale up design approaches, and economical part fabrication methods. Field evaluation work needs to be done to verify the TMC real world performance, and get acceptance from the industry, and pave the way for our commercial partner to put it into a much larger waste heat and waste water recovery market. This project is addressing the priority areas specified for DOE Industrial Technologies Program's (ITP's): Energy Intensive Processes (EIP) Portfolio - Waste Heat Minimization and Recovery platform.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Energy and Water Recovery Technology from Low Grade Waste Heat

The project has developed a nanoporous membrane based water vapor separation technology that can be used for recovering energy and water from low-temperature industrial waste gas streams with high moisture contents. This kind of exhaust stream is widely present in many industrial processes including the forest products and paper industry, food industry, chemical industry, cement industry, metal industry, and petroleum industry. The technology can recover not only the sensible heat but also high-purity water along with its considerable latent heat. Waste heats from such streams are considered very difficult to recover by conventional technology because of poor heat transfer performance of heat-exchanger type equipment at low temperature and moisture-related corrosion issues. During the one-year Concept Definition stage of the project, the goal was to prove the concept and technology in the laboratory and identify any issues that need to be addressed in future development of this technology. In this project, computational modeling and simulation have been conducted to investigate the performance of a nanoporous material based technology, transport membrane condenser (TMC), for waste heat and water recovery from low grade industrial flue gases. A series of theoretical and computational analyses have provided insight and support in advanced TMC design and experiments. Experimental study revealed condensation and convection through the porous membrane bundle was greatly improved over an impermeable tube bundle, because of the membrane capillary condensation mechanism and the continuous evacuation of the condensate film or droplets through the membrane pores. Convection Nusselt number in flue gas side for the porous membrane tube bundle is 50% to 80% higher than those for the impermeable stainless steel tube bundle. The condensation rates for the porous membrane tube bundle also increase 60% to 80%. Parametric study for the porous membrane tube bundle heat transfer performance was also done, which shows this heat transfer enhancement approach works well in a wide parameters range for typical flue gas conditions. Better understanding of condensing heat transfer mechanism for porous membrane heat transfer surfaces, shows higher condensation and heat transfer rates than non-permeable tubes, due to existence of the porous membrane walls. Laboratory testing has documented increased TMC performance with increased exhaust gas moisture content levels, which has exponentially increased potential markets for the product. The TMC technology can uniquely enhance waste heat recovery in tandem with water vapor recovery for many other industrial processes such as drying, wet and dry scrubber exhaust gases, dewatering, and water chilling. A new metallic substrate membrane tube development and molded TMC part fabrication method, provides an economical way to expand this technology for scaled up applications with less than 3 year payback expectation. A detailed market study shows a broad application area for this advanced waste heat and water recovery technology. A commercialization partner has been lined up to expand this technology to this big market. This research work led to new findings on the TMC working mechanism to improve its performance, better scale up design approaches, and economical part fabrication methods. Field evaluation work needs to be done to verify the TMC real world performance, and get acceptance from the industry, and pave the way for our commercial partner to put it into a much larger waste heat and waste water recovery market. This project is addressing the priority areas specified for DOE Industrial Technologies Program's (ITP's): Energy Intensive Processes (EIP) Portfolio - Waste Heat Minimization and Recovery platform.

02 PETROLEUM↗