Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVALUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Investigating realistic anode off-gas combustion in SOFC/ICE hybrid systems: mini review and experimental evaluation

Solid oxide fuel cells (SOFCs) have been deployed in hybrid decentralized energy systems, in which they are directly coupled to internal combustion engines (ICEs). Prior research indicated that the anode tailgas exiting the SOFC stack should be additionally exploited due to its high energy value, with typical ICE operation favoring hybridization due to matching thermodynamic conditions during operation. Consequently, extensive research has been performed, in which engines are positioned downstream the SOFC subsystem, operating in several modes of combustion, with the most prevalent being homogeneous compression ignition (HCCI) and spark ignition (SI). Experiments were performed in a 3-cylinder ICE operating in the latter modus operandi, where the anode tailgas was assimilated by mixing syngas (H 2 : 33.9%, CO: 15.6%, CO 2 : 50.5%) with three different water vapor flowrates in the engine’s intake. While increased vapor content significantly undermined engine performance, brake thermal efficiency (BTE) surpassed 34% in the best case scenario, which outperformed the majority of engines operating under similar operating conditions, as determined from the conducted literature review. Nevertheless, the best performing application was identified operating under HCCI, in which diesel reformates assimilating SOFC anode tailgas, fueled a heavy duty ICE (17:1), and gross indicated thermal efficiency ([Formula: see text]) of 48.8% was achieved, with the same engine exhibiting identical performance when operating in reactivity-controlled compression ignition (RCCI). Overall, emissions in terms of NO x and CO were minimal, especially in SI engines, while unburned hydrocarbons (UHC) were non-existent due to the absence of hydrocarbons in the assessed reformates.

Engineering↗

Parametric evaluation of ducted fuel injection in an optically accessible mixing-controlled compression-ignition engine with two- and four-duct assemblies

Ducted fuel injection (DFI) is a strategy to improve fuel/charge-gas mixing in direct-injection compression-ignition engines. DFI involves injecting fuel along the axis of a small tube in the combustion chamber, which promotes the formation of locally leaner mixtures in the autoignition zone relative to conventional diesel combustion. Previous work has demonstrated that DFI is effective at curtailing engine-out soot emissions across a wide range of operating conditions. This study extends previous investigations, presenting engine-out emissions and efficiency trends between ducted two-orifice and ducted four-orifice injector tip configurations. For each configuration, parameters investigated include injection pressure, injection duration, intake manifold pressure, intake manifold temperature, start of combustion timing, and intake-oxygen mole fraction. For both configurations and across all parameters, DFI reduced engine-out soot emissions compared to conventional diesel combustion, with little effect on other emissions and engine efficiency. Emissions trends for both configurations were qualitatively the same across the parameters investigated. The four-duct configuration had higher thermal efficiency and indicated-specific engine-out nitrogen oxide emissions but lower indicated-specific engine-out hydrocarbon and carbon monoxide emissions than the two-duct assembly. Both configurations achieved indicated-specific engine-out emissions for both soot and nitrogen oxides that comply with current on- and off-road heavy-duty regulations in the United States without exhaust-gas aftertreatment at an intake-oxygen mole fraction of 12%. High-speed in-cylinder imaging of natural soot luminosity shows that some conditions include a second soot-production phase late in the cycle. The probability of these late-cycle events is sensitive to both the number of ducted sprays and the operating conditions.

Yraguen, Boni Frances↗

Evaluation of hydrogen isotope exchange methodology on adsorbents for tritium removal

The Savannah River National Laboratory has demonstrated a potential process that can be used to remove tritium from tritiated water using Pt-catalyzed molecular sieves. The process is an elemental isotope exchange process in which H{sub 2} (when flowed through the molecular sieves) will exchange with the adsorbed water, D{sub 2}O, leaving H{sub 2}O adsorbed on the molecular sieves. Various formulations of catalyzed molecular sieve material were prepared using two different techniques, Pt-implantation and Pt-ion exchange. This technology has been demonstrated for a protium (H) and deuterium (D) system, but can also be used for the removal of tritium from contaminated water (T{sub 2}O, HTO, and DTO) using D{sub 2} (or H{sub 2}). (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of Polyethylene and Blank Pulsed Sphere Experiments Using Deuteron Transport Feature in COG

From the late 1960s to about 1985, LLNL undertook a series of ‘pulsed sphere’ experiments for 31 materials involving 148 different experiments using 75 different spheres. The purpose was to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d,n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transfer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge upon tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. COG is a three-dimensional, continuous energy, Monte Carlo code, developed by Lawrence Livermore National Laboratory (LLNL). Recent additions to COG include alpha and deuteron particle transport in order to directly calculate (α,n) and 3 H(d,n) 4 He reactions, and resulting neutron emission spectra. Results of the direct deuteron transport calculation for the 0.8 MFP (mean free path) polyethylene sphere with PILOT B detector was previously published. The purpose of this paper is to present expanded COG results showing the neutron peak from deuterium buildup ( 2 H(d,n) 3 He) due to tritium decay in the target. Cross section data libraries used are ENDF/B-VIII.0 for neutrons and ENDF/B-VII.1 for deuterons, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Freeze It or Leave It? Evaluating the Role of Cryo-Electron Microscopy in Battery Research

Cryogenic electron microscopy (cryo-EM) continues to gain prominence in materials science, particularly in battery research where it has enabled high-resolution, multimodal characterization of electrode materials and interfaces that otherwise degrade quickly under electron beam irradiation. But as anyone who has attempted cryo-EM techniques knows, freezing comes at a cost; cryo-EM experiments are time-consuming, highly sensitive, and carry an increased risk of artifacts due to issues such as frost contamination. Thus, when planning new characterization of battery materials or other beam-sensitive samples, it is critical to consider whether (and which) cryo-EM techniques are appropriate, based on study goals and an understanding of electron beam-sample interactions. Here we review such considerations for battery materials to elucidate the questions of when, why, and how to freeze to achieve high-quality characterization.

25 ENERGY STORAGE↗

Quantum-mechanical evaluation of Np-incorporation into studtite

Radionuclide incorporation into the alteration products of corroded UO 2 in used nuclear fuel may control the release and mobility of key radionuclides, such as the very long-lived minor actinide, 237 Np (τ ½ = 2.1 Ma). Studtite, [UO 2 (O 2 )(H 2 O) 2 ](H 2 O) 2 , may form in the presence of peroxide produced by radiolysis of water in contact with the spent fuel. Experiments have indicated that the studtite structure can incorporate Np; however, due to the low concentrations in the solid, the incorporation mechanism could not be determined. In this study, density functional theory is used to calculate an optimized structure, determine the electronic density of states, and calculate the energetics of the incorporation of Np 6+ vs. Np 5+ +H + into the studtite structure. The definition of the source/sink phase (reference phase) for the cations involved in the incorporation process greatly affects the final incorporation energy. The incorporation energy of Np into studtite based on the 4 + oxide reference phases (e.g., source/sink = NpO 2 /UO 2 ) results in lower incorporation energies (-0.07 and 0.63 eV for Np 6+ and Np 5+ incorporation, respectively) than the incorporation energy calculated using higher-oxide reference phases (e.g., Np 2 O 5 /UO 3 ), where the incorporation energies for Np 5+ and Np 5+ into studtite are 0.42 and 1.12 eV, respectively. In addition, Np6+-incorporation into studtite is energetically more favorable than Np 5+ -incorporation as assessed from the lower incorporation energy. Estimates of the solid-solution behavior from a combination of quantum-mechanical calculations and Monte-Carlo simulations indicate that the Np 6+ - and U 6+ -studtite solid solution is completely miscible at room temperature with respect to a hypothetical Np 6+ -studtite structure. The Np-studtite structure was calculated to be stable with respect to the corresponding oxides, but its formation may be kinetically hindered. Knowledge of the electronic structure provides insight into Np-bonding in the studtite structure. The Np 5f orbitals are within the band gap of studtite, which results in the narrow band gap of Np-incorporated studtite (1.09 eV), as compared with the band gap of studtite alone (2.29 eV).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications – Acquire Nortek Residential AC/HP Units for Evaluation and Model the Units Using HPDM

For the upcoming refrigerant transition from HFCs to minorly flammable HFO refrigerants (A2L), refrigerant charge reduction is important to mitigate the fire hazard. Microchannel heat exchangers (MHXs) are a mature technology, which is effective in reducing system charge while maintaining similar heat transfer performance. MHXs will be applied more widely when the new refrigerants are used. Prior studies of the A2L HFO blends were mostly focused on fin-and-tube coils (FTC). An in-depth study for an air conditioner (AC)/heat pump (HP) system using all microchannel heat exchangers is still lacking. In FY19, a side-to-side comparison will be conducted between two residential split heat pumps, one using all FTCs and the other using all MHXs for drop-in investigation, to identify potential issues for future design. The two heat pumps have similar rated capacity, SEER, HSPF levels, similar fan, blower and compressor, but differ in heat exchangers. Both the HPs use two-stage compressors to facilitate investigating different refrigerant flow rates. We will drop-in HFO refrigerants (replacements for R-410A, e.g. R452B, R447B, R32, etc.). The experiments will reveal the potential of MHXs for charge reduction, and how the two systems using A2L refrigerants operate under standard SEER and HSPF rating conditions. The two units were donated by our partner, i.e. Nortek Global HVAC, an industry leader in making heat pumps using all MHXs as well as FTCs. The units were shipped to ORNL this week, and the product design data were also shared for modeling the two units using HPDM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Defender Policy Evaluation and Resource Allocation against MITRE ATT&CK Data and Evaluations

Protecting against multi-step attacks of uncertain duration and timing forces defenders into an indefinite, always ongoing, resource-intensive response. To effectively allocate resources, a defender must be able to analyze multi-step attacks under assumption of constantly allocating resources against an uncertain stream of potentially undetected attacks. To achieve this goal, we present a novel methodology that applies a game-theoretic approach to the attack, attacker, and defender data derived from MITRE´s ATT&CK ® Framework. Time to complete attack steps is drawn from a probability distribution determined by attacker and defender strategies and capabilities. This constraints attack success parameters and enables comparing different defender resource allocation strategies. By approximating attacker-defender games as Markov processes, we represent the attacker-defender interaction, estimate the attack success parameters, determine the effects of attacker and defender strategies, and maximize opportunities for defender strategy improvements against an uncertain stream of attacks. This novel representation and analysis of multi-step attacks enables defender policy optimization and resource allocation, which we illustrate using the data from MITRE´ s APT3 ATT&CK ® Framework.

97 MATHEMATICS AND COMPUTING↗

Bench‐Scale Evaluation of Hydrothermal Processing Technology for Conversion of Wastewater Solids to Fuels: Marrone et al.

ABSTRACT: Hydrothermal Liquefaction (HTL) and Catalytic Hydrothermal Gasification (CHG) proof‐of‐concept bench‐scale tests were performed to assess the potential of hydrothermal treatment for handling municipal wastewater sludge. HTL tests were conducted at 300 to 350 °C and 20 MPa on three different feeds: primary sludge, secondary sludge, and digested solids. Corresponding CHG tests were conducted at 350 °C and 20 MPa on the HTL aqueous phase output using a ruthenium‐based catalyst. Biocrude yields ranged from 25 to 37%. Biocrude composition and quality were comparable to biocrudes generated from algae feeds. Subsequent hydrotreating of biocrude resulted in a product with comparable physical and chemical properties to crude oil. CHG product gas methane yields on a carbon basis ranged from 47 to 64%. Siloxane concentrations in the CHG product gas were below engine limits. The HTL‐CHG process resulted in a chemical oxygen demand (COD) reduction of > 99.9% and a reduction in residual solids for disposal of 94 to 99%.

Marrone, P. A.↗

Evaluation of Knock Behavior for Natural Gas - Gasoline Blends in a Light Duty Spark Ignited Engine

The compression ratio is a strong lever to increase the efficiency of an internal combustion engine. However, among others, it is limited by the knock resistance of the fuel used. Natural gas shows a higher knock resistance compared to gasoline, which makes it very attractive for use in internal combustion engines. The current paper describes the knock behavior of two gasoline fuels, and specific incylinder blend ratios with one of the gasoline fuels and natural gas. The engine used for these investigations is a single cylinder research engine for light duty application which is equipped with two separate fuel systems. Both fuels can be used simultaneously which allows for gasoline to be injected into the intake port and natural gas to be injected directly into the cylinder to overcome the power density loss usually connected with port fuel injection of natural gas. Adding natural gas at wide open throttle helps to reduce knock mitigating measures and increases the efficiency and power density compared to the other gasoline type fuels with lower knock resistance. The used methods, knock intensity and number of pressure waves, do not show significant differences in knock behavior for the natural gas - gasoline blends compared to the gasoline type fuels. A knock integral was used to describe the knock onset location of the fuels tested. Two different approaches were used to determine the experimental knock onset and were compared to the knock onset delivered by the knock integral (chemical knock onset). The gasoline type fuels show good agreement between chemical and experimental knock onset. However, the natural gas -gasoline blends show higher discrepancies comparing chemical and experimental knock onset.

Advanced Combustion Concept↗

Design of Modular Test Facility for Particle/sCO2 Heat Exchanger Evaluation

Heliogen has designed a 1.3 MW particle and supercritical carbon dioxide (sCO2) test loop to retire technical and manufacturing risks. The data from this facility will be used to validate near commercial-scale particle heat exchanger modules. The heat exchanger is scaled to capture all features of the full-scale modules. Testing will be conducted with CARBOBEAD HSP 16/30, a larger particle size than other recent testing. The system was designed to ASME codes with the constraint that sCO2 piping and other major components are stainless steels.

14 SOLAR ENERGY↗