Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPECTATION VALUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

New LHC benchmarks for the $\mathcal{CP}$-conserving two-Higgs-doublet model

We introduce a strategy to study the parameter space of the general, CP-conserving, two-Higgs-doublet Model (2HDM) with a softly broken $\mathbb Z_{2}$-symmetry by means of a new “hybrid” basis. In this basis the input parameters are the measured values of the mass of the observed Standard Model (SM)-like Higgs boson and its coupling strength to vector boson pairs, the mass of the second CP-even Higgs boson, the ratio of neutral Higgs vacuum expectation values, and three additional dimensionless parameters. Here, using the hybrid basis, we present numerical scans of the 2HDM parameter space where we survey available parameter regions and analyze model constraints. From these results, we define a number of benchmark scenarios that capture different aspects of non-standard Higgs phenomenology that are of interest for future LHC Higgs searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Synthetic Resilin Is Largely Unstructured

Proresilin is the precursor protein for resilin, an extremely elastic, hydrated, cross-linked insoluble protein found in insects. We investigated the secondary-structure distribution in solution of a synthetic proresilin (AN16), based on 16 units of the consensus proresilin repeat from Anopheles gambiae. Raman spectroscopy was used to verify that the secondary-structure distributions in cross-linked AN16 resilin and in AN16 proresilin are similar, and hence that solution techniques (such as NMR and circular dichroism) may be used to gain information about the structure of the cross-linked solid. The synthetic proresilin AN16 is an intrinsically unstructured protein, displaying under native conditions many of the characteristics normally observed in denatured proteins. There are no apparent {alpha}-helical or {beta}-sheet features in the NMR spectra, and the majority of backbone protons and carbons exhibit chemical shifts characteristic of random-coil configurations. Relatively few peaks are observed in the nuclear Overhauser effect spectra, indicating that overall the protein is dynamic and unstructured. The radius of gyration of AN16 corresponds to the value expected for a denatured protein of similar chain length. This high degree of disorder is also consistent with observed circular dichroism and Raman spectra. The temperature dependences of the NH proton chemical shifts were also measured. Most values were indicative of protons exposed to water, although smaller dependences were observed for glycine and alanine within the Tyr-Gly-Ala-Pro sequence conserved in all resilins found to date, which is the site of dityrosine cross-link formation. This result implies that these residues are involved in hydrogen bonds, possibly to enable efficient self-association and subsequent cross-linking. The {beta}-spiral model for elastic proteins, where the protein is itself shaped like a spring, is not supported by the results for AN16. Both the random-network elastomer model and the sliding {beta}-turn model are consistent with the data. The results indicate a flat energy landscape for AN16, with very little energy required to switch between conformations. This ease of switching is likely to lead to the extremely low energy loss on deformation of resilin.

08 HYDROGEN↗

IMPACTS OF SMALL COLUMN ION EXCHANGE STREAMS ON DWPF GLASS FORMULATION KT07-SERIES GLASS COMPOSITIONS

This report is the third in a series of studies of the impacts of the addition of Crystalline Silicotitanate (CST) and Monosodium Titanate (MST) from the Small Column Ion Exchange (SCIX) process on the Defense Waste Processing Facility (DWPF) glass waste form and the applicability of the DWPF process control models. MST from the Salt Waste Processing Facility is also considered in the study. The KT07-series glasses were selected to evaluate any potential impacts of noble metals on their properties and performance. The glasses characterized thus far for the SCIX study have not included noble metals since they are not typically tracked in sludge batch composition projections. However, noble metals can act as nucleation sites in glass melts, leading to enhanced crystallization. This crystallization can potentially influence the properties and performance of the glass, such as chemical durability, viscosity, and liquidus temperature. The noble metals Ag, Pd, Rh, and Ru were added to the KT07-series glasses in concentrations based on recent measurements of Sludge Batch 6, which was considered to contain a high concentration of noble metals. The KT04-series glasses were used as the baseline compositions. After fabrication, the glasses were characterized to determine their homogeneity, chemical composition, durability, and viscosity. Liquidus temperature measurements are also underway but were not complete at the time of this report. The liquidus temperature results for the KT07-series glasses, along with several of the earlier glasses in the SCIX study, will be documented separately. All of the KT07-series glasses, both quenched and slowly cooled, were found to be amorphous by X-ray diffraction. Chemical composition measurements showed that all of the glasses met their targeted compositions. The Product Consistency Test (PCT) results showed that all of the glasses had chemical durabilities that were far better than that of the Environmental Assessment benchmark glass. The measured PCT responses were well predicted by the current DWPF Product Composition Control System (PCCS) durability models. The measured viscosity values for each KT07-series glass were acceptable for DWPF processing and were well predicted by the current PCCS model. Overall, the results show that the inclusion of relatively high concentrations of noble metals (in terms of expected values for a DWPF sludge batch) had no significant impact on the properties and performance of these glass compositions. There were no significant differences in the measured properties when compared to those of the KT04-series glasses, which did not contain noble metals. Liquidus temperature measurements are still underway and there may be an impact of the noble metals on those measurements. However, no adverse effects were noted in terms of crystallization after slow cooling. At the completion of these studies, all of the data generated will be reviewed with regard to the applicability of the DWPF PCCS models and recommendations will be made as to whether the validation ranges of the current models can be extended, or whether some or all of the models need to be refit to allow for the incorporation of the SCIX streams. As changes are made to the projected sludge compositions and the volume of the SCIX material, additional evaluations should be performed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An independent limit on the axion mass from the variable white dwarf star R548

Pulsating white dwarfs with hydrogen-rich atmospheres, also known as DAV stars, can be used as astrophysical laboratories to constrain the properties of fundamental particles like axions. Comparing the measured cooling rates of these stars with the expected values from theoretical models allows us to search for sources of additional cooling due to the emission of weakly interacting particles. In this paper, we present an independent inference of the mass of the axion using the recent determination of the evolutionary cooling rate of R548, the DAV class prototype. We employ a state-of-the-art code which allows us to perform a detailed asteroseismological fit based on fully evolutionary sequences. Stellar cooling is the solely responsible of the rates of change of period with time (.Π)) for the DAV class. Thus, the inclusion of axion emission in these sequences notably influences the evolutionary timescales, and also the expected pulsational properties of the DAV stars. This allows us to compare the theoretical .Π) values to the corresponding empirical rate of change of period with time of R548 to discern the presence of axion cooling. We found that if the dominant period at 213.13 s in R548 is associated with a pulsation mode trapped in the hydrogen envelope, our models indicate the existence of additional cooling in this pulsating white dwarf, consistent with axions of mass m{sub a}cos {sup 2}β ∼ 17.1 meV at a 2σ confidence level. This determination is in agreement with the value inferred from another well-studied DAV, G117-B15A. We now have two independent and consistent estimates of the mass of the axion obtained from DAVs, although additional studies of other pulsating white dwarfs are needed to confirm this value of the axion mass.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanorod Mobility within Entangled Wormlike Micelle Solutions

In the semi-dilute regime, wormlike micelles form an isotropic entangled microstructure that is similar to that of an entangled polymer solution with a characteristic, nanometer-scale entanglement mesh size. We report a combined x-ray photon correlation spectroscopy (XPCS) and rheology study to investigate the translational dynamics of gold nanorods in semi-dilute solutions of entangled wormlike micelles formed by the surfactant cetylpyridinium chloride (CPyCl) and the counter-ion sodium salicylate (NaSal). The CPyCl concentration is varied to tune the entanglement mesh size over a range that spans from approximately equal to the nanorod diameter to larger than the nanorod length. The NaSal concentration is varied along with the CPyCl concentration so that the solutions have the maximum viscosity for given CPyCl concentration. On short time scales the nanorods are localized on a length scale matching that expected from the high-frequency elastic modulus of the solutions as long as the mesh size is smaller than the rod length. On longer time scales, the nanorods undergo free diffusion. At the highest CPyCl concentrations, the nanorod diffusivity approaches the value expected based on the macroscopic viscosity of the solutions, but it increases with decreasing CPyCl concentration more rapidly than expected from the macroscopic viscosity. A recent model by Cai et al. [Cai, L.-H.; Panyukov, S.; Rubinstein, M. Macromolecules 2015, 48, 847-862.] for nanoparticle “hopping” diffusion in entangled polymer solutions accounts quantitatively for this enhanced diffusivity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

IMPLICATIONS OF RAPID CORE ROTATION IN RED GIANTS FOR INTERNAL ANGULAR MOMENTUM TRANSPORT IN STARS

Core rotation rates have been measured for red giant stars using asteroseismology. These data, along with helioseismic measurements and open cluster spin-down studies, provide powerful clues about the nature and timescale for internal angular momentum transport in stars. We focus on two cases: the metal-poor red giant KIC 7341231 ({sup O}tto{sup )} and intermediate-mass core helium burning stars. For both, we examine limiting case studies for angular momentum coupling between cores and envelopes under the assumption of rigid rotation on the main sequence. We discuss the expected pattern of core rotation as a function of mass and radius. In the case of Otto, strong post-main-sequence coupling is ruled out and the measured core rotation rate is in the range of 23-33 times the surface value expected from standard spin-down models. The minimum coupling timescale (0.17-0.45 Gyr) is significantly longer than that inferred for young open cluster stars. This implies ineffective internal angular momentum transport in early first ascent giants. By contrast, the core rotation rates of evolved secondary clump stars are found to be consistent with strong coupling given their rapid main-sequence rotation. An extrapolation to the white dwarf regime predicts rotation periods between 330 and 0.0052 days, depending on mass and decoupling time. We identify two key ingredients that explain these features: the presence of a convective core and inefficient angular momentum transport in the presence of larger mean molecular weight gradients. Observational tests that can disentangle these effects are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Interpreting the Strongly Lensed Supernova iPTF16geu: Time Delay Predictions, Microlensing, and Lensing Rates

We present predictions for time delays between multiple images of the gravitationally lensed supernova, iPTF16geu, which was recently discovered from the intermediate Palomar Transient Factory (iPTF). As the supernova is of Type Ia where the intrinsic luminosity is usually well known, accurately measured time delays of the multiple images could provide tight constraints on the Hubble constant. According to our lens mass models constrained by the Hubble Space Telescope F814W image, we expect the maximum relative time delay to be less than a day, which is consistent with the maximum of 100 hr reported by Goobar et al. but places a stringent upper limit. Furthermore, the fluxes of most of the supernova images depart from expected values suggesting that they are affected by microlensing. The microlensing timescales are small enough that they may pose significant problems to measure the time delays reliably. Our lensing rate calculation indicates that the occurrence of a lensed SN in iPTF is likely. However, the observed total magnification of iPTF16geu is larger than expected, given its redshift. This may be a further indication of ongoing microlensing in this system.

79 ASTRONOMY AND ASTROPHYSICS↗

Solving two-dimensional large-N QCD with a nonzero density of baryons and arbitrary quark mass

We solve two-dimensional large-N QCD in the presence of a nonzero baryon number B, and for arbitrary quark mass m and volume L. We fully treat the dynamics of the gluonic zero modes and check how this affects results from previous studies of the B=0 and B=1 systems. For a finite density of baryons, and for any m>0, we find that the ground state contains a baryon crystal with expectation values for <{psi}{gamma}{sub {mu}}{psi}> that have a helixlike spatial structure. We study how these evolve with B and see that the volume integral of <{psi}{psi}> strongly changes with the baryon density. We compare this emerging crystal structure with the sine-Gordon crystal, which is expected to be a good approximation for light quarks, and find that it is a very good approximation for surprisingly heavy quarks. We also calculate the way the ground state energy E changes as a function of the baryon number B, and find that for sufficiently large densities the function E(B) is well described by the equation of state for free massless quarks, thus suggesting a quark-Hadron continuity. From {partial_derivative}E(B)/{partial_derivative}B we calculate the quark chemical potential {mu} as a function of B and see that the baryons repel each other. The way {mu} depends on B also allows us to translate our findings to the grand-canonical ensemble. The resulting phase structure along the {mu} axis contains a phase transition that occurs at a value of {mu} equal to the baryon mass divided in N, and that separates a {mu}-independent phase with intact translation symmetry from a {mu}-dependent phase with spontaneously broken translation symmetry. Finally, our calculations confirm the presence of a partial large-N Eguchi-Kawai volume independence, as described in [Phys. Rev. D 79, 105021 (2009)], that arises only if one treats the gluonic zero modes correctly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for octupolar order in NpO 2 by neutron powder diffraction

The magnetic structure of neptunium dioxide (NpO 2 ) remains a mystery despite decades of research. We revisited the search for magnetic ordering in NpO 2 by performing a powder neutron diffraction experiment at low temperatures and relatively large values of Q. Diffraction data were collected for 300 MK, 15 K, and 35 K to understand the phase transition near 25 K. However, no significant changes in the neutron diffraction pattern were identified. Using the octupolar magnetic form factor j 6 , the maximum theoretical expected value of the magnetic moment (3.27 μ B ), the calculated magnetic Bragg peak intensities would not be observable in neutron powder diffraction data. This value is much larger than the previously estimated magnetic moment of ~0.1 μ B . In conclusion, supported by experimental results, these calculations suggest that unpolarized neutron powder diffraction is unsuitable for measuring octupolar ordering in NpO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search for the Standard Model Higgs Boson in Missing Transverse Energy and $b$-quark Final States Using Proton-Antiproton Collisions at 1.96 TeV

A search for the standard model Higgs boson is performed in 6.4 fb -1 of p$\bar{p}$ collisions at √s = 1.96 TeV, collected with the DØ detector during Run II of the Fermilab Tevatron. The final state considered is a pair of jets originating from b quarks and missing transverse energy, as expected from p$\bar{p}$ → ZH → v$\bar{v}$b$\bar{b}$ production. The search is also sensitive to the WH → ℓvb$\bar{b}$ channel, where the charged lepton is not identified. Boosted decision trees are used to discriminate signal from background. Good agreement is observed between data and expected backgrounds, and a limit is set at 95% C.L. on the section multiplied by branching fraction of (p$\bar{p}$ → (Z/W)H) x (H → b$\bar{b}$). For a Higgs boson mass of 115 GeV, the observed limit is a factor of 3.5 larger than the value expected from the standard model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermophysical Properties of Liquid Tritium: A Path Integral Monte Carlo Study

Here, we present worm-algorithm, path integral Monte Carlo simulations of bulk liquid tritium. The simulations are benchmarked against empirically known thermophysical properties of liquid deuterium and liquid tritium. Results for the pair correlation function, chemical potential, isothermal compressibility, isochoric heat capacity, and single-particle momentum distributions are reported. Given the benchmark comparisons, our predictions of liquid tritium properties are expected to be accurate to within a few percent. Our simulations unambiguously demonstrate the significance of nuclear quantum effects to the properties of liquid tritium. In particular, under saturated vapor pressure, the average molecular kinetic energy of the liquid is found to be more than 60% higher than the value expected from the classical equipartition theorem.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automating linear accelerator quality assurance

Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. Conclusions: The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-08: Real-Time Monte Carlo-Based Treatment Dose Reconstruction and Monitoring for Radiotherapy

Purpose: This proof-of-concept study is to develop a real-time Monte Carlo (MC) based treatment-dose reconstruction and monitoring system for radiotherapy, especially for the treatments with complicated delivery, to catch treatment delivery errors at the earliest possible opportunity and interrupt the treatment only when an unacceptable dosimetric deviation from our expectation occurs. Methods: First an offline scheme is launched to pre-calculate the expected dose from the treatment plan, used as ground truth for real-time monitoring later. Then an online scheme with three concurrent threads is launched while treatment delivering, to reconstruct and monitor the patient dose in a temporally resolved fashion in real-time. Thread T1 acquires machine status every 20 ms to calculate and accumulate fluence map (FM). Once our accumulation threshold is reached, T1 transfers the FM to T2 for dose reconstruction ad starts to accumulate a new FM. A GPU-based MC dose calculation is performed on T2 when MC dose engine is ready and a new FM is available. The reconstructed instantaneous dose is directed to T3 for dose accumulation and real-time visualization. Multiple dose metrics (e.g. maximum and mean dose for targets and organs) are calculated from the current accumulated dose and compared with the pre-calculated expected values. Once the discrepancies go beyond our tolerance, an error message will be send to interrupt the treatment delivery. Results: A VMAT Head-and-neck patient case was used to test the performance of our system. Real-time machine status acquisition was simulated here. The differences between the actual dose metrics and the expected ones were 0.06%–0.36%, indicating an accurate delivery. ∼10Hz frequency of dose reconstruction and monitoring was achieved, with 287.94s online computation time compared to 287.84s treatment delivery time. Conclusion: Our study has demonstrated the feasibility of computing a dose distribution in a temporally resolved fashion in real-time and quantitatively and dosimetrically monitoring the treatment delivery.

60 APPLIED LIFE SCIENCES↗

Image-based spectral distortion correction for photon-counting x-ray detectors

Purpose: To investigate the feasibility of using an image-based method to correct for distortions induced by various artifacts in the x-ray spectrum recorded with photon-counting detectors for their application in breast computed tomography (CT). Methods: The polyenergetic incident spectrum was simulated with the tungsten anode spectral model using the interpolating polynomials (TASMIP) code and carefully calibrated to match the x-ray tube in this study. Experiments were performed on a Cadmium-Zinc-Telluride (CZT) photon-counting detector with five energy thresholds. Energy bins were adjusted to evenly distribute the recorded counts above the noise floor. BR12 phantoms of various thicknesses were used for calibration. A nonlinear function was selected to fit the count correlation between the simulated and the measured spectra in the calibration process. To evaluate the proposed spectral distortion correction method, an empirical fitting derived from the calibration process was applied on the raw images recorded for polymethyl methacrylate (PMMA) phantoms of 8.7, 48.8, and 100.0 mm. Both the corrected counts and the effective attenuation coefficient were compared to the simulated values for each of the five energy bins. The feasibility of applying the proposed method to quantitative material decomposition was tested using a dual-energy imaging technique with a three-material phantom that consisted of water, lipid, and protein. The performance of the spectral distortion correction method was quantified using the relative root-mean-square (RMS) error with respect to the expected values from simulations or areal analysis of the decomposition phantom. Results: The implementation of the proposed method reduced the relative RMS error of the output counts in the five energy bins with respect to the simulated incident counts from 23.0%, 33.0%, and 54.0% to 1.2%, 1.8%, and 7.7% for 8.7, 48.8, and 100.0 mm PMMA phantoms, respectively. The accuracy of the effective attenuation coefficient of PMMA estimate was also improved with the proposed spectral distortion correction. Finally, the relative RMS error of water, lipid, and protein decompositions in dual-energy imaging was significantly reduced from 53.4% to 6.8% after correction was applied. Conclusions: The study demonstrated that dramatic distortions in the recorded raw image yielded from a photon-counting detector could be expected, which presents great challenges for applying the quantitative material decomposition method in spectral CT. The proposed semi-empirical correction method can effectively reduce these errors caused by various artifacts, including pulse pileup and charge sharing effects. Furthermore, rather than detector-specific simulation packages, the method requires a relatively simple calibration process and knowledge about the incident spectrum. Therefore, it may be used as a generalized procedure for the spectral distortion correction of different photon-counting detectors in clinical breast CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Some remarks on anthropic approaches to the strong CP problem

The peculiar value of θ is a challenge to the notion of an anthropic landscape. We briefly review the possibility that a suitable axion might arise from an anthropic requirement of dark matter. We then consider an alternative suggestion of Kaloper and Terning that θ might be correlated with the cosmological constant. We note that in a landscape one expects that θ is determined by the expectation value of one or more axions. We discuss how a discretuum of values of θ might arise with an energy distribution dominated by QCD, and find the requirements to be quite stringent. Given such a discretuum, we find no circumstances where small θ might be selected by anthropic requirements on the cosmological constant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

BPS Wilson loop in $\mathcal{N}$ = 2 superconformal SU(N) “orientifold” gauge theory and weak-strong coupling interpolation

We consider the expectation value \( \left\langle \mathcal{W}\right\rangle \) of the circular BPS Wilson loop in \( \mathcal{N} \) = 2 superconformal SU( N ) gauge theory containing a vector multiplet coupled to two hypermultiplets in rank-2 symmetric and antisymmetric representations. This theory admits a regular large N expansion, is planar-equivalent to \( \mathcal{N} \) = 4 SYM theory and is expected to be dual to a certain orbifold/orientifold projection of AdS 5 × S 5 superstring theory. On the string theory side \( \left\langle \mathcal{W}\right\rangle \) is represented by the path integral expanded near the same AdS 2 minimal surface as in the maximally supersymmetric case. Following the string theory argument in [5], we suggest that as in the \( \mathcal{N} \) = 4 SYM case and in the \( \mathcal{N} \) = 2 SU( N ) × SU( N ) superconformal quiver theory discussed in [19], the coefficient of the leading non-planar 1/ N 2 correction in \( \left\langle \mathcal{W}\right\rangle \) should have the universal λ 3/2 scaling at large ’t Hooft coupling. We confirm this prediction by starting with the localization matrix model representation for \( \left\langle \mathcal{W}\right\rangle \) . We complement the analytic derivation of the λ 3/2 scaling by a numerical high-precision resummation and extrapolation of the weak-coupling expansion using conformal mapping improved Padé analysis.

1/N Expansion↗