Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical Conductivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A Revised Calibration Function and Results for the Phoenix Mission TECP Relative Humidity Sensor

The original calibration function of the R(sub H) sensor on the Phoenix Thermal and Electrical Conductivity Sensor (TECP) has been revised in order to extend the range of the valid calibration, and to improve accuracy. The original function returned non-physical R(sub H) values at the lowest temperatures. To resolve this, and because the original calibration was performed against a pair of hygrometers that measured frost point (T(sub f)), the revised calibration equation is also cast in terms of frost point. Because of the complexity of maintaining very low temperatures and high R(sub H) in the laboratory, no calibration data exists at T is greater than 203K. However, sensor response during the mission was smooth and continuous down to 181 K. Therefore we have opted to include flight data in the calibration data set; selection was limited to data acquired during periods when the atmosphere is known to have been saturated. T(sub f) remained below 210 K throughout the mission(P is greater than 0.75 Pa). R(sub H), conversely, ranged from 1 to well under 0.01 diurnally, due to approximately 50 K temperature variations. To first order, both vapor pressure and its variance are greater during daylight hours. Variance in overnight humidity is almost entirely explained by temperature, while atmospheric turbulence contributes substantial variance to daytime humidity. Likewise, data gathered with the TECP aloft reflect higher H2O abundances than at the surface, as well as greater variance. There is evidence for saturation of the atmosphere overnight throughout much of the mission. In virtually every overnight observation, once the atmosphere cooled to T(sub f), water vapor begins to decrease, and tracks air temperature. There is no evidence for substantial decreases in water vapor prior to saturation, as expected for adsorptive exchange. Likewise, there is no evidence of local control of vapor by phases such as perchlorate hydrates hydrated minerals. The daytime average H2O pressure does not change substantially over the course of the mission, although the H2O column abundance varies by a factor of 2. Column abundances calculated from TECP data are lower than orbital measurements if one assumes that H2O is uniformly mixed through a single scale height. These results argue that the vertical distribution of H2O begins to change well in advance of surface concentrations as northern autumn approaches.

Phoenix Thermal and Electrical Conductivity Sensor↗

Room temperature measurements of electrical resistivity and thermal conductivity of various graphites

Room temperature thermal conductivity measurements were completed on 10 graphite samples selected from the lot of 120 to uniformly span the range of electrical resistivity values. From these data and other measurements a thermal conductivity-electrical conductivity correlation was established to predict room temperature thermal conductivity values for the graphite samples. The correlation, expressed by a parabolic equation, represents available thermal and electrical conductivity data to about + or - 8%.

Mcelroy, D. L.↗

Measuring Electrical Resistivity Of Compacted Powder

Slightly modified micrometer used in conjunction with special cup to measure electrical resistance of specimen of powder as function of packing fraction. Powder pressed between anvils of micrometer, which make electrical contact with specimen. Device used in manufacturing batteries to determine effective electrical conductivities of powders loaded into plastic sheets to make battery substrates. Coupled with good mathematical description of expected conductivity of particulate composite as function of packing density. Also serves as tool for evaluating conductivity of dispersed phase, as well as evaluating electrical resistances of interparticle contacts.

Shlichta, Paul J.↗

Micromechanical and Electrical Properties of Monolithic Aluminum Nitride at High Temperatures

Micromechanical spectroscopy of aluminum nitride reveals it to possess extremely low background internal friction at less than 1x10(exp-4) logarithmic decrement (log dec) from 20 to 1200 T. Two mechanical loss peaks were observed, the first at 350 C approximating a single Debye peak with a peak height of 60x10(exp-4) log dec. The second peak was seen at 950 'C with a peak height of 20x 10' log dec and extended from 200 to over 1200 C. These micromechanical observations manifested themselves in the electrical behavior of these materials. Electrical conduction processes were predominately intrinsic. Both mechanical and electrical relaxations appear to be thermally activated processes, with activation energies of 0.78 and 1.32 eV respectively.

Goldsby, Jon C.↗

Micromechanical and Electrical Properties of Monolithic Aluminum Nitride at High Temperatures

Micromechanical spectroscopy of aluminum nitride reveals it to possess extremely low background internal friction at less than 1 x 10 (exp -4) logarithmic decrement (log dec.) from 20 to 1200 C. Two mechanical loss peaks were observed, the first at 350 C approximating a single Debye peak with a peak height of 60 x 10 (exp -4) log dec. The second peak was seen at 950 C with a peak height of 20 x 10 (exp -4) log dec. and extended from 200 to over 1200 C. These micromechanical observations manifested themselves in the electrical behavior of these materials. Electrical conduction processes were predominately intrinsic. Both mechanical and electrical relaxations appear to be thermally activated processes, with activation energies of 0.78 and 1.32 eV respectively.

Goldsby, Jon C.↗

Technology Assessment for Producing Propellant From Lunar Water

Introduction: The presence of water ice in permanently shadowed regions (PSRs) on the lunar surface may enable a sustained human presence on the Moon with minimal need for consumables. One of the most valuable uses of lunar water is to produce rocket propellant. A sustained human presence on the Moon will re-quire frequent launches from the lunar surface, and each launch will require tons of propellant. However, many other volatiles are likely to be present in the areas where lunar water is stable1. Producing propellant from lunar water in-situ will require the separation and purification of water before it can be electrolyzed into oxygen and hydrogen gas. The Resource Exploration and Science of OUR Cosmic Environment (RESOURCE) project, funded by the Solar System Exploration Research Virtual Institute (SSERVI) program, includes a task to demonstrate the end-to-end process of water extraction, capture, purification and electrolysis to produce pure/dry oxygen gas sourced from an icy regolith mixture. Water Purification: The requirements for water purity are driven by the type of water electrolyzer used. For example, the water electrolyzer currently used on the International Space Station is based on proton ex-change membrane (PEM) technology. PEM-based electrolyzers require water to be ultrapure and deionized (>10 MegaOhm-cm) so that electrical conductivity is limited to the membranes themselves, where electrical current is used to convert H2O into H2 and O2.. A practical first step toward purifying water that is sourced from a lunar PSR is to use freeze distillation to separate water from other volatiles2. A sub-micronic filter can also be used to ensure that a minimal amount of dust is present in any lunar water that is captured. The combination of freeze distillation and sub-micronic filtration will result in relatively pure water but would require a deionization step if being fed into a PEM electrolyzer. Water Electrolysis: An alternative to PEM electrolysis is to use a Solid Oxide Electrolyzer (SOE). This technology operates at a much higher operating temperature (~800oC) and has a limited pressure range but does not require water to be ultrapure and deionized. Another advantage of SOE technology is that it produces pure dry oxygen gas without the need of an additional drying step. PEM electrolyzers produce humid oxygen gas and the humidity must be removed prior to liquefaction. Assessment: In order to compare PEM and SOE technologies side-by-side, they must be compared at a system level that includes water purification and gas drying steps. Engineers at the Johnson Space Center up-dated and utilized a detailed In-Situ Resource Utilization (ISRU) system model to compare and select the best option for the RESOURCE project which will conclude with a laboratory demonstration of the process of producing pure/dry oxygen from an icy regolith mixture in 2025.

A.J. Paz↗

Technology Assessment for Producing Propellant From Lunar Water

Introduction: The presence of water ice in permanently shadowed regions (PSRs) on the lunar surface may enable a sustained human presence on the Moon with minimal need for consumables. One of the most valuable uses of lunar water is to produce rocket propellant. A sustained human presence on the Moon will re-quire frequent launches from the lunar surface, and each launch will require tons of propellant. However, many other volatiles are likely to be present in the areas where lunar water is stable1. Producing propellant from lunar water in-situ will require the separation and purification of water before it can be electrolyzed into oxygen and hydrogen gas. The Resource Exploration and Science of OUR Cosmic Environment (RESOURCE) project, funded by the Solar System Exploration Research Virtual Institute (SSERVI) program, includes a task to demonstrate the end-to-end process of water extraction, capture, purification and electrolysis to produce pure/dry oxygen gas sourced from an icy regolith mixture. Water Purification: The requirements for water purity are driven by the type of water electrolyzer used. For example, the water electrolyzer currently used on the International Space Station is based on proton ex-change membrane (PEM) technology. PEM-based electrolyzers require water to be ultrapure and deionized (>10 MegaOhm-cm) so that electrical conductivity is limited to the membranes themselves, where electrical current is used to convert H2O into H2 and O2.. A practical first step toward purifying water that is sourced from a lunar PSR is to use freeze distillation to separate water from other volatiles2. A sub-micronic filter can also be used to ensure that a minimal amount of dust is present in any lunar water that is captured. The combination of freeze distillation and sub-micronic filtration will result in relatively pure water but would require a deionization step if being fed into a PEM electrolyzer. Water Electrolysis: An alternative to PEM electrolysis is to use a Solid Oxide Electrolyzer (SOE). This technology operates at a much higher operating temperature (~800oC) and has a limited pressure range but does not require water to be ultrapure and deionized. Another advantage of SOE technology is that it produces pure dry oxygen gas without the need of an additional drying step. PEM electrolyzers produce humid oxygen gas and the humidity must be removed prior to liquefaction. Assessment: In order to compare PEM and SOE technologies side-by-side, they must be compared at a system level that includes water purification and gas drying steps. Engineers at the Johnson Space Center up-dated and utilized a detailed In-Situ Resource Utilization (ISRU) system model to compare and select the best option for the RESOURCE project which will conclude with a laboratory demonstration of the process of producing pure/dry oxygen from an icy regolith mixture in 2025.

ISRU↗

Role of dielectric constant in electrohydrodynamics of conducting fluids

Electrohydrodynamic (EHD) flows are driven by the interaction of an electric field with variations in electric conductivity or dielectric constant. In reported EHD experiments on the deformation of drops of immiscible dielectric fluids, the role of conductivity has tended to overshadow the role of dielectric constant. Often, large conductivity contrasts were convenient because the conductivities of the dielectric fluid were relatively uncertain. As a result, the observed effects were always qualitatively the same as if there had been no contrast in dielectric constant. Our early experiments studying the EHC deformations of cylindrical streams readily showed the conductivity effect but the dielectric constant effect was not discernible. We have modified our flow chamber and improved our method of observation and can now see an unequivocal dielectric constant effect which is in agreement with the prior theory. In this paper we first give a brief description of the physics of charge buildup at the interface of an immersed spherical drop or flowing cylindrical sample stream and then show how these charge distributions lead to interface distortions and accompanying viscous flows which constitute EHD. We next review theory and experiment describing the deformation of spherical drops. We show that in the reported drop deformation experiments, the contrast in dielectric constant was never sufficient to reverse the deformation due to the conductivity contrast. We review our work describing the deformation of a cylindrical stream of one fluid flowing in a parallel flow of another, and we compare the deformation equations with those for spherical drops. Finally, we show a definite experimental dielectric constant effect for cylindrical stream of aqueous polystyrene latex suspension. The dielectric constant varies with the frequency of the imposed electric field, and the associated EHD flow change is very apparent.

Rhodes, Percy H.↗

Electric and thermal conductivities of quenched neutron star crusts

The electric and thermal conductivities in the outer crustal matter of a neutron star quenched into a solid state by cooling are estimated using a Monte Carlo simulation of freezing transition for dense plasmas. The conductivities are calculated by the precise evaluation of the scattering integrals, using the procedure of Ichimaru et al. (1983) and Iyetomi and Ichimaru (1983). The results predict the conductivities lower, by a factor of about 3, than those with the single-phonon approximation.

Ogata, Shuji↗

Conductance Oscillations in Squashed Carbon Nanotubes

A combination of molecular dynamics and electrical conductance calculations are used to probe the electromechanical properties of squashed metallic carbon nanotubes. We find that the conductance and bandgap of armchair nanotubes show oscillations upon squashing. The physical origin of these oscillations is attributed to interaction of carbon atoms with a fourth neighbor. Squashing of armchair and zigzag nanotubes ultimately leads to metallic behavior.

Mehrez, H.↗

Electron Beam Irradiated Intercalated CNT Yarns For Aerospace Applications

Multi-walled CNT yarns have been experimentally and commercially created to yield lightweight, high conductivity fibers with good tensile properties for application as electrical wiring and multifunctional tendons. Multifunctional tendons are needed as the cable structures in tensegrity robots for use in planetary exploration. These lightweight robust tendons can provide mechanical strength for movement of the robot in addition to power distribution and data transmission. In aerospace vehicles, such as Orion, electrical wiring and harnessing mass can approach half of the avionics mass. Use of CNT yarns as electrical power and data cables could reduce mass of the wiring by thirty to seventy percent. These fibers have been intercalated with mixed halogens to increase their specific electrical conductivity to that near copper. This conductivity, combined with the superior strength and fatigue resistance makes it an attractive alternative to copper for wiring and multifunctional tendon applications. Electron beam irradiation has been shown to increase mechanical strength in pristine CNT fibers through increased cross-linking. Both pristine and intercalated CNT yarns have been irradiated using a 5-megavolt electron beam for various durations and the conductivities and tensile properties will be discussed. Structural information obtained using a field emission scanning electron microscope, energy dispersive X-ray spectroscopy (EDS), and Raman spectroscopy will correlate microstructural details with bulk properties.

electrical wiring↗

A facility for the simulation of environmental parameters and qualification of flight thermal coatings

There is a continuing interest and need for investigation and development of, various paints, coatings, multi-layer insulation, and electrically conductive paints and coatings used for thermal control and electrical discharge of spacecraft surfaces. Degradation of these surfaces by solar-wind energy particles and ultraviolet irradiation, as well as contamination by the outgassing of materials used in conjunction or close proximity to these surfaces, continues to be a matter of concern. The following is a description of a facility with the capability of evaluating the synergistic effects encountered in the space environment. Actual flight qualification programs are also described.

Paczkowski, F. N.↗

Rotary Transformer Seals Power In

Rotary transformer originally developed for spacecraft transfers electrical power from stationary primary winding to rotating secondary without sliding contacts and very little leakage of electromagnetic radiation. Transformer has two stationary primary windings connected in parallel. Secondary, mounted on a shaft that extends out of housing, rotates between two windings of primary. Shaft of secondary is composed of electrically conducting inner and outer parts separated by an insulator. Electrical contact is made from secondary winding, through shaft, to external leads.

Studer, P. A.↗

The role of oxygen in porous molybdenum electrodes for the alkali metal thermoelectric converter

A model for chemical reactions in porous molybdenum electrodes is presented which is based on thermochemical and kinetic data, known sodium-molybdenum-oxygen chemistry, X-ray diffraction analysis of molybdenum and molybdenum oxide electrodes, and the electrochemical behavior of the cell. Enhanced sodium transport through the electrode in its optimum performance state is found to be due to the high sodium ion conductivity of molten Na2MoO4 in the pores, and the electrical conduction to the molybdenum matrix by Na2Mo3O6. The decline of electrode performance is shown to be due to a combination of loss mechanisms for the Na-Mo-O compounds including reduction at short circuit, disproportionation of Na2Mo3O6 at open circuit, and the evaporation of Na2MoO4 at elevated temperature. It is suggested that operation of the cell at moderate voltage of about 0.5 V corresponding to maximum power may be a more stable condition for the porous electrode than open-circuit stand or short-circuit, where degradation reactions are heightened.

Williams, R. M.↗

Sintered Fiber Electrodes

Method proposed to make improved porous electrodes for oxygen pumps, oxygen sensors, high-temperature solid-electrolyte fuel cells, and high-temperature solid-electrolyte electrolysis cells. Electrode made by sintering mat of conducting fibers. Many sintered bonds between intersecting fibers increase electrical conductivity and provide strength, yet allow mat to remain highly porous.

Schroeder, James E.↗

Design and construction of high-sensitivity, infrared bolometers for operation at 300 mK

The design and construction of 300-mK composite bolometers developed for millimeter-wave astronomical observations are described. Graphite fibers are used as the electrical leads for the thermistor to reduce the thermal conductance and heat capacity associated with the leads. A mechanical suspension made of Nylon fibers provides the required thermal conductance. Electrical noise equivalent powers below 1 x 10 exp -16 W/sq rt Hz have been achieved for detectors with thermal time constants of 11 ms. The detectors were installed in a millimeter-wave photometer and used to perform observations of the cosmic microwave background from a balloonborne platform. The flight performance was consistent with the measured laboratory properties.

Alsop, D. C.↗

Ceramic Interconnects with Low Sintering Temperature

Ceramic interconnects for use in solid oxide he1 cells are expected to operate between 900 to approximately 1000 C, sinter below 1400 C to allow co-firing and meet a number thermal mechanical requirements. The pervoskite type (ABO3) lanthanum chromite based materials have emerged as a leading candidate that will meet these criteria by varying the composition on the A and B sites. A need therefore exists to determine this material's temperature dependent electrical and mechanical properties with respect to these site substitutions. In this investigation oxide powders were prepared by the glycine-nitrate process. Ionic substitutions were carried out on A sites with Ca or Sr, and B sites with Co and Al, respectively. Only stoichiometric compositions were considered for the sake of stability. The powders and their ability to sinter were investigated by XRD, SEM, dilatometry and density measurements. The sintered materials were further examined by SEM, thermal expansion and electric conductivity measurements in order to elucidate the resulting microstructure, electrical and mechanical properties. In addition quantum mechanical calculations were performed to obtain insight into the effects of these dopants on the materials electronic band structure and lattice parameter.

Zhong, Zhi-Min↗

Thermal protection system ablation sensor

An isotherm sensor tracks space vehicle temperatures by a thermal protection system (TPS) material during vehicle re-entry as a function of time, and surface recession through calibration, calculation, analysis and exposed surface modeling. Sensor design includes: two resistive conductors, wound around a tube, with a first end of each conductor connected to a constant current source, and second ends electrically insulated from each other by a selected material that becomes an electrically conductive char at higher temperatures to thereby complete an electrical circuit. The sensor conductors become shorter as ablation proceeds and reduced resistance in the completed electrical circuit (proportional to conductor length) is continually monitored, using measured end-to-end voltage change or current in the circuit. Thermocouple and/or piezoelectric measurements provide consistency checks on local temperatures.

Gorbunov, Sergey↗