Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Plasma self-driven current in tokamaks with magnetic islands

Magnetic island perturbations may cause a reduction in plasma self-driven current that is needed for tokamak operation. A novel effect on tokamak self-driven current revealed by global gyrokinetic simulations is due to magnetic-island-induced 3D electric potential structures, which have the same dominant mode numbers as that of the magnetic island, whereas centered at both the inner and outer edge of the island. The non-resonant potential islands are shown to drive a current through an efficient nonlinear parallel acceleration of electrons. In large aspect ratio (large-A) tokamak devices, this new effect can result in a significant global reduction of the electron bootstrap current when the island size is sufficiently large, in addition to the local current loss across the island region due to the pressure profile flattening. It is shown that there exists a critical magnetic island width for large-A tokamaks beyond which the electron bootstrap current loss is global and increases rapidly with the island size. As such, this process may introduce a size limit for tolerable magnetic islands in large-A tokamak devices in the context of steady state operation. On the other hand, the current loss caused by magnetic islands in low-A tokamaks such as spherical tokamak (ST) NSTX/U is minor. The reduction of the axisymmetric current by magnetic islands scales with the square of island width. However, the loss of the current is mainly local to the island region, and the pace of current loss as the island size increases is substantially slower compared to large-A tokamaks. In particular, the bootstrap current reduction in STs is even smaller in the reactor-relevant high-β p regime where neoclassical tearing modes are more likely to develop.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a direct-sampling RF receiver for precision beam charge measurements in the MOLLER experiment

Here, we have developed and tested a direct-sampling RF receiver capable of measuring the amplitude of a 1497 MHz sinusoidal beam signal in 0.5 ms integration windows with a relative uncertainty of better than 10 parts per million. The receiver is intended for measuring signals from beam current monitoring cavities on the beamline of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. The beam signal strength, frequency, and integration window fulfill the thus far unmet requirements of the upcoming MOLLER experiment to measure the beam charge for different helicity states.

47 OTHER INSTRUMENTATION↗

Performance of a liquid Ga target for Laser Ion Source

We experimentally proved the feasibility of a liquid-based target for Laser Ion Source (LIS) application. The target consists of melted metal gallium contained in a heated crucible. Ions current resulting from laser irradiation. Moreover, given the explosive ablation mechanism involved, each laser shot has been found to induce fluctuations in the surface level. It takes about 0.7 sec to recover the steady condition fully. Despite the maximum fluctuation being 2.7 mm (top-bottom maximum displacement), these fluctuations have shown no significant influence on total ion current and are independent of the temperature of the sample within the tested repetition rate. This study provides valuable insights into the potential of employing such a system for LIS.

43 PARTICLE ACCELERATORS↗

Commissioning of a replacement subatmospheric cold box for Jefferson Lab’s Central Helium Liquefier

Jefferson Lab’s Cryogenics Department has designed, fabricated, installed, and commissioned a new subatmospheric cold box to replace one of the two existing units within our Central Helium Liquefier (CHL). The replacement cold box, dubbed SC1R, pumps saturated helium vapor at 0.0385 atm from Jefferson Lab’s continuous electron beam accelerator facility (CEBAF) cryomodules to maintain an operating temperature of nominally 2.1 K. This is accomplished using a five-stage cryogenic centrifugal compressor (cold compressor) system and a brazed aluminum plate-fin heat exchanger operating between 2.1 K and 4.5 K. In this paper we will describe our experience commissioning the SC1R cold box. We will discuss pump-down of the system to 2.1 K and steady-state operation at the cold compressor design flow rates of 170, 200, and 250 g/s. Performance of the heat exchanger and cold compressors has been mapped across a range of flow rates and optimized for CEBAF operations. This commissioning data will be used to monitor future performance and adapt to changing load requirements.

Mastracci, B.↗

Gamma-ray observations of MAXI J1820+070 during the 2018 outburst

ABSTRACT MAXI J1820+070 is a low-mass X-ray binary with a black hole (BH) as a compact object. This binary underwent an exceptionally bright X-ray outburst from 2018 March to October, showing evidence of a non-thermal particle population through its radio emission during this whole period. The combined results of 59.5 h of observations of the MAXI J1820+070 outburst with the H.E.S.S., MAGIC and VERITAS experiments at energies above 200 GeV are presented, together with Fermi-LAT data between 0.1 and 500 GeV, and multiwavelength observations from radio to X-rays. Gamma-ray emission is not detected from MAXI J1820+070, but the obtained upper limits and the multiwavelength data allow us to put meaningful constraints on the source properties under reasonable assumptions regarding the non-thermal particle population and the jet synchrotron spectrum. In particular, it is possible to show that, if a high-energy (HE) gamma-ray emitting region is present during the hard state of the source, its predicted flux should be at most a factor of 20 below the obtained Fermi-LAT upper limits, and closer to them for magnetic fields significantly below equipartition. During the state transitions, under the plausible assumption that electrons are accelerated up to ∼500 GeV, the multiwavelength data and the gamma-ray upper limits lead consistently to the conclusion that a potential HE and very-HE gamma-ray emitting region should be located at a distance from the BH ranging between 1011 and 1013 cm. Similar outbursts from low-mass X-ray binaries might be detectable in the near future with upcoming instruments such as CTA.

Astronomy & Astrophysics↗

Small-𝑥 gluon GPD constrained from deeply virtual 𝐽/𝜓 production and gluon PDF through universal-moment parametrization

We phenomenologically constrain the small-𝑥 and small-𝜉 gluon generalized parton distributions (GPDs) with the deeply virtual 𝐽/𝜓 production (DV⁢𝐽/𝜓⁢P) in the framework of GPDs through universal moment parameterization (GUMP). We use a hybrid cross-section formula combining collinear factorization to the next-to-leading order (NLO) accuracy of the strong coupling 𝛼 𝑠 , with corrections from nonrelativistic QCD to account for the power corrections due to the heavy 𝐽/𝜓 mass. We reach reasonable fit to the measured differential cross sections of DV⁢𝐽/𝜓⁢P by H1 at the Hadron-Electron Ring Accelerator as well as forward gluon parton distribution functions (PDFs) from JAM22 global analysis. We find that both NLO and nonrelativistic corrections are significant for heavy vector meson productions. Of course, the gluon GPD we obtain still contains considerable freedom in need of inputs from other constraints, particularly in the distribution-amplitude-like region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Global Bayesian analysis of J/𝜓 photoproduction on proton and lead targets

We perform a global Bayesian analysis of diffractive J/𝜓 production in 𝛾 + 𝑝 and 𝛾 + Pb collisions using a color glass condensate (CGC) based calculation framework. As past calculations have shown that CGC-based models typically overpredict the J/𝜓 production in 𝛾 + Pb collisions at high center of mass energy, we address the question of whether it is possible to describe coherent and incoherent diffractive J/𝜓 data from 𝛾 + 𝑝 collisions at Hadron–Electron Ring Accelerator (HERA) and the LHC, and from 𝛾 + Pb collisions at the LHC simultaneously. Our results indicate that a simultaneous description of 𝛾 + 𝑝 and 𝛾 + Pb data is challenging, with results improving when an overall 𝐾-factor—scaling 𝛾 + 𝑝 and 𝛾 + Pb cross sections to absorb model uncertainties—is introduced.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Above-threshold ionization at laser intensity greater than 10 20 W / cm 2

Here we present experimental observation of above-threshold ionization (ATI) electrons produced by ionization of the neon K shell in a laser field where intensity exceeds 10 20 W/cm 2 . An array of plastic scintillating calorimeter detectors was used to measure the high-energy electrons at four angles in the laser forward direction. Coarse energy resolution was obtained using aluminum filters of several thicknesses to block lower-energy electrons. A threshold intensity around 2×10 20 W/cm 2 is observed for production of energetic ATI electrons in the laser forward direction, with maximum electron energy exceeding 10 MeV. L-shell electrons with energies <1.4 MeV are scattered farther forward along the laser direction than expected. We present comparisons of the measured total electron energies to the predictions of Monte Carlo models employing the ADK-PPT ionization model and the Augst barrier suppression ionization model.

74 ATOMIC AND MOLECULAR PHYSICS↗

Detecting anomalous SRF cavity behavior with unsupervised learning

We present an unsupervised learning framework for detecting anomalous superconducting radio-frequency (SRF) cavity behavior at the Continuous Electron Beam Accelerator Facility (CEBAF), emphasizing its initial performance and effectiveness. Key to the system’s success was the development of data acquisition systems (DAQs) that capture fast-sampled, information-rich signals, essential for detecting transient effects. The approach involves creating daily cavity-specific models using principal component analysis to handle variations in rf signal behavior and mitigate performance degradation from data drift. This unsupervised method eliminates the need for expensive labeling by continuously updating models with recent data. Deployed and operational for 3 months before a scheduled shutdown, the system successfully identified several issues with DAQ signals, confirming its effectiveness. Despite access to only a fraction of CEBAF’s SRF cavity signals, the framework efficiently detected several instances requiring intervention, demonstrating a significant improvement over traditional, labor-intensive methods of manual plot inspection. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of U 238 ( n , n ' γ ) cross section data and their impact on reaction models

A better knowledge of (n,xn) reaction cross sections is important for both reaction modeling and energy applications. This article focuses on inelastic scattering of neutrons off 238 U for which improvements are needed to better constrain evaluations and solve inconsistencies in nuclear power reactor calculations. A new precise measurement of (n,xnγ) reaction cross sections on 238 U has been performed at the GELINA (Geel Electron LINear Accelerator) neutron facility operated by EC-JRC-Geel (Belgium) with the GRAPhEME (GeRmanium array for Actinides PrEcise MEasurements) setup. The prompt γ-ray spectroscopy method coupled to time-of-flight measurements is used to extract (n,xnγ) cross section values which can be further combined to infer the total neutron inelastic scattering cross section. Cross section data for 18 γ transitions (five never measured before) are presented and compared to the data in the literature. Here, emphasis is especially given to the uncertainty determination to produce partial cross section data as accurate as possible. Due to intrinsic limitations of the experimental method, the use of additional nuclear structure information coupled with theoretical modeling is required to determine the total (n, n') cross section over the whole neutron energy range. We have investigated modeling aspects of the 238 U(n,n'γ) cross sections related to the description of compound nucleus and preequilibirum mechanisms as well as the discrete part of nuclear structure. Through comparison between experimental and calculated (n,n'γ) cross sections, we pinpoint inaccuracies in the description of specific reaction mechanisms and challenge recently implemented models. This helps improving the whole modeling of the (n, n') reaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved $^{95}\mathrm{Mo}$ neutron resonance parameters and astrophysical reaction rates

We report improved 95 Mo neutron resonance parameters and reaction rates are important for nuclear astrophysics, testing nuclear models, and nuclear criticality safety. However, despite many previous neutron-capture and total cross-section measurements on this nuclide, there still is much room for improvement as well as several discrepancies. For example, there are very few firm resonance spin and parity assignments; average resonance parameters are available only for each parity, the currently recommended astrophysical reaction rate results in disagreements between stellar models and meteoric isotopic anomalies, and there are substantial disagreements in the neutron-capture cross section at low energies important for nuclear criticality safety. To obtain an improved set of neutron resonance parameters and astrophysical reaction rates for 95 Mo. High-resolution neutron-capture and transmission data were measured at the Oak Ridge Electron Linear Accelerator (ORELA) using highly isotopically enriched 95 Mo samples. The neutron-capture apparatus, data reduction, and analysis were improved so that information contained in the γ-ray cascade following neutron capture were used to assign resonance J π values. Following this, simultaneous analysis of the new neutron-capture and transmission data was used to obtain resonance energies, gamma widths, and neutron widths and their uncertainties to a maximum energy of 10 keV. Accurate neutron-capture cross sections also were obtained for the unresolved resonance region to a maximum energy of 500 keV and, together with the new resonance parameters, used to calculate the astrophysical reaction rates in the temperature range from 5 to 30 keV. A vastly improved set of 95Mo neutron resonance parameters and an astrophysical reaction rate accurate to about 3% were obtained. Firm J π assignments were determined for 261 of the 314 observed resonances. This is a very large improvement over the previously published 32 firm J π assignments for 108 resonances. Also, the number of resonances having both firm J π assignments and Γ γ values was increased by almost a factor of 24—from 11 to 261. Neutron- and total-radiation-width distributions and average resonance spacings, average total radiation widths, and neutron strength functions were obtained for the six different s- and p-wave possibilities. Parameters for the lowest s-wave resonance, which is most important for criticality benchmarks, were obtained with high accuracy. Simple modification of the neutron-capture apparatus and expansion and improvement of data analysis techniques led to a large increase in firm J π assignments for 95 Mo neutron resonances. The resulting astrophysical reaction rate is 20%–30% larger than the currently recommended rate at s-process temperatures, which should lead to better agreement between stellar models and meteoric isotopic anomalies. The neutron-capture cross section at low energies is substantially larger than recommended in the latest evaluation, which is problematical for criticality benchmarks. The average resonance spacing as a function of spin and parity is significantly different from current models. The total-radiation-width distributions are significantly broader than predicted by theory and show significant departures from the expected Gaussian shapes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Injection of electron beams into two laser wakefields and generation of electron rings

Throughout this work, mutual injection of electron beams into two laser plasma wakefields was observed experimentally when driving laser pulses interfered in plasma at a small crossing angle and were slightly relatively delayed, approximately by one pulse duration. Particle-in-cell simulations revealed that the mutual injection was sensitive to the spatial overlap of the laser pulses, which therefore could be used to control the mutual injection. The dual synchronized, femtosecond electron beams are potentially useful for pump-probe experiments in ultrafast science. In addition, out-of-axis ring-shaped electron beams were detected in both experiments and simulations.

47 OTHER INSTRUMENTATION↗