Search NASA⌕ Search

SEARCH · Search NASA

Results for “Enhanced Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Macroscopic weavable fibers of carbon nanotubes with giant thermoelectric power factor

Low-dimensional materials have recently attracted much interest as thermoelectric materials because of their charge carrier confinement leading to thermoelectric performance enhancement. Carbon nanotubes are promising candidates because of their one-dimensionality in addition to their unique advantages such as flexibility and light weight. However, preserving the large power factor of individual carbon nanotubes in macroscopic assemblies has been challenging, primarily due to poor sample morphology and a lack of proper Fermi energy tuning. Here, we report an ultrahigh value of power factor (14± 5 mW m -1 K -2 ) for macroscopic weavable fibers of aligned carbon nanotubes with ultrahigh electrical and thermal conductivity. The observed giant power factor originates from the ultrahigh electrical conductivity achieved through excellent sample morphology, combined with an enhanced Seebeck coefficient through Fermi energy tuning. We fabricate a textile thermoelectric generator based on these carbon nanotube fibers, which demonstrates high thermoelectric performance, weavability, and scalability. The giant power factor we observe make these fibers strong candidates for the emerging field of thermoelectric active cooling, which requires a large thermoelectric power factor and a large thermal conductivity at the same time.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Enhanced NIF neutron activation diagnostics

The NIF neutron activation diagnostic suite relies on removable activation samples, leading to operational inefficiencies and a fundamental lower limit on the half-life of the activated product that can be observed. A neutron diagnostic system measuring activation of permanently installed samples could remove these limitations and significantly enhance overall neutron diagnostic capabilities. The physics and engineering aspects of two proposed systems are considered: one measuring the {sup 89}Zr/{sup 89m}Zr isomer ratio in the existing Zr activation medium and the other using potassium zirconate as the activation medium. Both proposed systems could improve the signal-to-noise ratio of the current system by at least a factor of 5 and would allow independent measurement of fusion core velocity and fuel areal density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic spectra and Richter aftereffect relaxation in Ce{sub x}Y{sub 3−x}Fe{sub 5}O{sub 12} ferrites

The static and dynamic magnetic properties of cerium (Ce) doped yttrium iron garnet Ce{sub x}Y{sub 3−x}Fe{sub 5}O{sub 12} (x=0, 0.05, 0.1, 0.15, 0.2) ferrites (YIG) have been reported in this work. The ferrites were fabricated by the traditional solid-state reaction method. All ferrite samples reveal pure garnet structure identified by x-ray diffraction (XRD). The substitution of cerium not only enhances the saturation magnetization of the samples, but also regulates the magnetocrystalline anisotropy constant K{sub 1}. Obvious differences in permeability spectra over a frequency of 1 MHz - 1 GHz can be observed. It is verified that the permeability dispersion and magnetic losses of Ce-doped YIG ferrite contain the contribution of Richter aftereffect relaxation due to the existence of Fe{sup 2+} ions. The fitting results of the permeability spectra applied three-mechanism model is in good agreement with experimental data, which successfully explains the mechanisms of magnetic losses observed at 1 MHz to 1 GHz for Ce-doped YIG ferrite. In addition, the frequency shift of Richter aftereffect has also been discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale effects in the characterization of viscoelastic materials with atomic force microscopy: Coupling of a quasi-three-dimensional standard linear solid model with in-plane surface interactions

Significant progress has been accomplished in the development of experimental contact-mode and dynamic-mode atomic force microscopy (AFM) methods designed to measure surface material properties. However, current methods are based on one-dimensional (1D) descriptions of the tip-sample interaction forces, thus neglecting the intricacies involved in the material behavior of complex samples (such as soft viscoelastic materials) as well as the differences in material response between the surface and the bulk. In order to begin to address this gap, a computational study is presented where the sample is simulated using an enhanced version of a recently introduced model that treats the surface as a collection of standard-linear-solid viscoelastic elements. The enhanced model introduces in-plane surface elastic forces that can be approximately related to a two-dimensional (2D) Young's modulus. Relevant cases are discussed for single-and multifrequency intermittent-contact AFM imaging, with focus on the calculated surface indentation profiles and tip-sample interaction force curves, as well as their implications with regards to experimental interpretation. A variety of phenomena are examined in detail, which highlight the need for further development of more physically accurate sample models that are specifically designed for AFM simulation. As a result, a multifrequency AFM simulation tool based on the above sample model is provided as supporting information.

36 MATERIALS SCIENCE↗

Plasmonic Three-Dimensional Transparent Conductor Based on Al-Doped Zinc Oxide-Coated Nanostructured Glass Using Atomic Layer Deposition

Transparent nanostructured glass coatings, fabricated on glass substrates, with a unique three-dimensional (3D) architecture were utilized as the foundation for the design of plasmonic 3D transparent conductors. Transformation of the non-conducting 3D structure to a conducting 3D network was accomplished through atomic layer deposition of aluminum-doped zinc oxide (AZO). After AZO growth, gold nanoparticles (AuNPs) were deposited by electronbeam evaporation to enhance light trapping and decrease the overall sheet resistance. Field emission scanning electron microscopy and atomic force microcopy images revealed the highly porous, nanostructured morphology of the AZO coated glass surface along with the in-plane dimensions of the deposited AuNPs. Sheet resistance measurements conducted on the coated samples verified that the electrical properties of the 3D network are comparable to that of the untextured two-dimensional AZO coated glass substrates. In addition, transmittance measurements of the glass samples coated with various AZO thicknesses showed preservation of the highly transparent nature of each sample, while the AuNPs demonstrated enhanced light scattering as well as light-trapping capability.

36 MATERIALS SCIENCE↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

Blind identification of full-field vibration modes of output-only structures from uniformly-sampled, possibly temporally-aliased (sub-Nyquist), video measurements

Enhancing the spatial and temporal resolution of vibration measurements and modal analysis could significantly benefit dynamic modelling, analysis, and health monitoring of structures. For example, spatially high-density mode shapes are critical for accurate vibration-based damage localization. In experimental or operational modal analysis, higher (frequency) modes, which may be outside the frequency range of the measurement, contain local structural features that can improve damage localization as well as the construction and updating of the modal-based dynamic model of the structure. In general, the resolution of vibration measurements can be increased by enhanced hardware. Traditional vibration measurement sensors such as accelerometers have high-frequency sampling capacity; however, they are discrete point-wise sensors only providing sparse, low spatial sensing resolution measurements, while dense deployment to achieve high spatial resolution is expensive and results in the mass-loading effect and modification of structure's surface. Non-contact measurement methods such as scanning laser vibrometers provide high spatial and temporal resolution sensing capacity; however, they make measurements sequentially that requires considerable acquisition time. As an alternative non-contact method, digital video cameras are relatively low-cost, agile, and provide high spatial resolution, simultaneous, measurements. Combined with vision based algorithms (e.g., image correlation or template matching, optical flow, etc.), video camera based measurements have been successfully used for experimental and operational vibration measurement and subsequent modal analysis. However, the sampling frequency of most affordable digital cameras is limited to 30–60 Hz, while high-speed cameras for higher frequency vibration measurements are extremely costly. This work develops a computational algorithm capable of performing vibration measurement at a uniform sampling frequency lower than what is required by the Shannon-Nyquist sampling theorem for output-only modal analysis. In particular, the spatio-temporal uncoupling property of the modal expansion of structural vibration responses enables a direct modal decoupling of the temporally-aliased vibration measurements by existing output-only modal analysis methods, yielding (full-field) mode shapes estimation directly. Then the signal aliasing properties in modal analysis is exploited to estimate the modal frequencies and damping ratios. Furthermore, the proposed method is validated by laboratory experiments where output-only modal identification is conducted on temporally-aliased acceleration responses and particularly the temporally-aliased video measurements of bench-scale structures, including a three-story building structure and a cantilever beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduced model of high-Z impurity redeposition and erosion in tokamak divertor and its application to DIII-D experiments

A reduced model of high-Z impurities erosion and redeposition is presented to analyze net erosion of tungsten material in divertor attached plasma conditions measured in DIII-D experiments. This reduced model is tailored to quantify the redeposition and the net erosion on high-Z material samples of sufficiently small dimensions to be considered exposed to uniform plasma conditions. For those uniform plasma conditions, the spatial distribution of redeposited high-Z impurities is well approximated by an analytical distribution characterized by a few parameters. The fraction of high-Z impurity eroding and redepositing on a material sample is then obtained by integrating this distribution across the material sample. Here, the ratio of net erosion rates of tungsten measured experimentally from tungsten samples of different sizes exposed to the same attached plasma conditions are well reproduced with this reduced model. It is shown that uncertainties induced by radially non-uniform plasma conditions in experiments can be significantly reduced by exposing samples to high density divertor plasma. Several enhanced experimental setups are proposed to measure and compare net erosion rates from samples of various areas during a single plasma experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic field induced extraordinary photoluminescence enhancement in Er{sup 3+}:YVO{sub 4} single crystal

A bright green photoluminescence (PL) from {sup 4}S{sub 3∕2} → {sup 4}I{sub 15∕2} emission band in Er{sup 3+}:YVO{sub 4} single crystal has been observed with the excitation of an argon laser at 488.0 nm. More than two orders of PL enhancement have been obtained under the effect of magnetic fields, and the enhancement factor f reaches 170 when the applied magnetic field is 7.7 T under the sample temperature of 4.2 K. Unusually, the PL enhancements only happen at some certain magnetic fields (B{sub c}s), and a decrease of sample temperature will lead to the increase of f and decrease of B{sub c}. The results confirm that this PL enhancement originates from the resonance excitation of the electron transitions induced by the cross of the laser energy and the absorption energy modulated by both the magnetic field and temperature. This special PL enhancement in Er{sup 3+}:YVO{sub 4} single crystal can be applied in the calibration of pulsed high magnetic field, detection of material fine energy structures, and modulation of magneto-optical devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Intrinsic Dosimetry: Elemental Composition Effects on the Thermoluminescence of Commercial Borosilicate Glass

Intrinsic dosimetry is the method of measuring total absorbed dose received by the walls of a container holding radioactive material. By considering this dose in tandem with the physical characteristics of the radioactive material housed within the container, this method can provide enhanced pathway information for interdicted radioactive samples. Thermoluminescence (TL) dosimetry was used to measure ionizing radiation dose effects on stock borosilicate glass. Differences in TL glow curve shape and intensity were observed for glasses from different geographical origins. The different TL signatures strongly correlated with the concentration of alkaline earth metals and the ratio of sodium to the total amount of alkali metal present in the borosilicate glass.

61 RADIATION PROTECTION AND DOSIMETRY↗

A high-temperature sample changer for parallelized in situ X-ray studies to efficiently explore reaction space

A sample environment for high-throughput X-ray scattering studies in transmission geometry to probe the mechanism and kinetics of moderate-temperature reactions in solution, molten fluxes and solids is described. This high-temperature sample changer enables efficient studies of reactions that are slow relative to the timescale of the X-ray scattering measurements by allowing up to 18 samples to be probed at the same temperature in parallel. This significantly enhances the throughput ofin situX-ray scattering studies as the sample changer effectively facilitates systematic studies that compare different reaction parameters (e.g.concentration, precursor, composition, additives), reference samples (e.g.background, pure precursors) and replicates (to demonstrate reproducibility) with enhanced consistency afforded by the quasi-simultaneous nature of the measurements. The large sample volumes, compared with those typically used for X-ray scattering measurements, are on a similar scale to those in the laboratory, making the results more directly comparable.

Chemistry↗

Coupling detergent lysis/clean-up methodology with intact protein fractionation for enhanced proteome characterization

The expanding use of surfactants for proteome sample preparations has prompted the need to systematically optimize the application and removal of these MS-deleterious agents prior to proteome measurements. Here we compare four different detergent clean-up methods (Trichloroacetic acid (TCA) precipitation, Chloroform/Methanol/Water (CMW) extraction, commercial detergent removal spin column method (DRS) and filter-aided sample preparation(FASP)) with respect to varying amounts of protein biomass in the samples, and provide efficiency benchmarks with respect to protein, peptide, and spectral identifications for each method. Our results show that for protein limited samples, FASP outperforms the other three clean-up methods, while at high protein amount all the methods are comparable. This information was used in a dual strategy of comparing molecular weight based fractionated and unfractionated lysates from three increasingly complex samples (Escherichia coli, a five microbial isolate mixture, and a natural microbial community groundwater sample), which were all lysed with SDS and cleaned up using FASP. The two approaches complemented each other by enhancing the number of protein identifications by 8%-25% across the three samples and provided broad pathway coverage.

FASP↗

Enhanced Monte Carlo Simulations for Electron Energy Loss Mitigation in Real-Space Nanoimaging of Thick Biological Samples and Microchips

High-resolution imaging using Transmission Electron Microscopy (TEM) is essential for applications such as grain boundary analysis, microchip defect characterization, and biological imaging. However, TEM images are often compromised by electron energy spread and other factors. In TEM mode, where the objective and projector lenses are positioned downstream of the sample, electron–sample interactions cause energy loss, which adversely impacts image quality and resolution. This study introduces a simulation tool to estimate the electron energy loss spectrum (EELS) as a function of sample thickness, covering electron beam energies from 300 keV to 3 MeV. Leveraging recent advances in MeV-TEM/STEM technology, which includes a state-of-the-art electron source with 2-picometer emittance, an energy spread of 3 × 10 -5 , and optimized beam characteristics, we aim to minimize energy spread. By integrating EELS capabilities into the BNL Monte Carlo (MC) simulation code for thicker samples, we evaluate electron beam parameters to mitigate energy spread resulting from electron–sample interactions. Based on our simulations, we propose an experimental procedure for quantitively distinguishing between elastic and inelastic scattering. The findings will guide the selection of optimal beam settings, thereby enhancing resolution for nanoimaging of thick biological samples and microchips.

36 MATERIALS SCIENCE↗

Influence of germanium nano-inclusions on the thermoelectric power factor of bulk bismuth telluride alloy

Nanocomposite thermoelectric compound of bismuth telluride (Bi{sub 2}Te{sub 3}) with 5 at. % germanium nano-inclusions was prepared via mechanically alloying and sintering techniques. The influence of Ge nano-inclusions and long duration annealing on the thermoelectric properties of nanostructured Bi{sub 2}Te{sub 3} were investigated. It was found that annealing has significant effect on the carrier concentration, Seebeck coefficient, and the power factor of the thermoelectric compound. The systematic heat treatment also reduced the density of donor type defects thereby decreasing the electron concentration. While the as-pressed nanocomposite materials showed n-type properties, it was observed that with the increase of annealing time, the nanocomposite gradually transformed to an abundantly hole-dominated (p-type) sample. The long duration annealing (∼500 h) resulted in a significantly enhanced electrical conductivity pertaining to the augmentation in the density and the structural properties of the sample. Therefore, a simultaneous enhancement in both electrical and Seebeck coefficient characteristics resulted in a remarkable increase in the thermoelectric power factor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of etch pits found on a large-grain bulk niobium superconducting radio-frequency resonant cavity

The performance of superconducting radio-frequency (SRF) resonant cavities made of bulk niobium is limited by nonlinear localized effects. Surface analysis of regions of higher power dissipation is thus of intense interest. Such areas (referred to as “hotspots”) were identified in a large-grain single-cell cavity that had been buffered-chemical polished and dissected for examination by high resolution electron microscopy, electron backscattered diffraction microscopy (EBSD), and optical microscopy. Pits with clearly discernible crystal facets were observed in both “hotspot” and “coldspot” specimens. The pits were found in-grain, at bicrystal boundaries, and on tricrystal junctions. They are interpreted as etch pits induced by crystal defects (e.g. dislocations). All coldspots examined had a qualitatively lower density of etch pits or relatively smooth tricrystal boundary junctions. EBSD mapping revealed the crystal orientation surrounding the pits. Locations with high pit density are correlated with higher mean values of the local average misorientation angle distributions, indicating a higher geometrically necessary dislocation content. In addition, a survey of the samples by energy dispersive x-ray analysis did not show any significant contamination of the samples’ surface. In conclusion, the local magnetic field enhancement produced by the sharp-edge features observed on the samples is not sufficient to explain the observed degradation of the cavity quality factor, which starts at peak surface magnetic field as low as 20 mT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EXTENDED ULTRAVIOLET DISKS AND ULTRAVIOLET-BRIGHT DISKS IN LOW-MASS E/S0 GALAXIES

We have identified 15 extended ultraviolet (XUV) disks in a largely field sample of 38 E/S0 galaxies that have stellar masses primarily below {approx}4 Multiplication-Sign 10{sup 10} M{sub Sun} and comparable numbers on the red and blue sequences. We use a new purely quantitative XUV-disk definition designed with reference to the 'Type 1' XUV-disk definition found in the literature, requiring UV extension relative to a UV-defined star formation threshold radius. The 39% {+-} 9% XUV-disk frequency for these E/S0s is roughly twice the {approx}20% reported for late-type galaxies (although differences in XUV-disk criteria complicate the comparison), possibly indicating that XUV disks are preferentially associated with galaxies experiencing weak or inefficient star formation. Consistent with this interpretation, we find that the XUV disks in our sample do not correlate with enhanced outer-disk star formation as traced by blue optical outer-disk colors. However, UV-Bright (UV-B) disk galaxies with blue UV colors outside their optical 50% light radii do display enhanced optical outer-disk star formation as well as enhanced atomic gas content. UV-B disks occur in our E/S0s with a 42{sup +9}{sub -8}% frequency and need not coincide with XUV disks; thus their combined frequency is 61% {+-} 9%. For both XUV and UV-B disks, UV colors typically imply <1 Gyr ages, and most such disks extend beyond the optical R{sub 25} radius. XUV disks occur over the full sample mass range and on both the red and blue sequences, suggesting an association with galaxy interactions or another similarly general evolutionary process. In contrast, UV-B disks favor the blue sequence and may also prefer low masses, perhaps reflecting the onset of cold-mode gas accretion or another mass-dependent evolutionary process. Virtually all blue E/S0s in the gas-rich regime below stellar mass M{sub t} {approx} 5 Multiplication-Sign 10{sup 9} M{sub Sun} (the 'gas-richness threshold mass') display UV-B disks, supporting the previously suggested association of this population with active disk growth.

79 ASTRONOMY AND ASTROPHYSICS↗

METHANOL MASER EMISSION FROM GALACTIC CENTER SOURCES WITH EXCESS 4.5 {mu}m EMISSION

We present a study of signatures of on-going star formation in a sample of protostellar objects with enhanced 4.5 {mu}m emission ('green' sources) near the Galactic center. To understand how star formation in the Galactic center region compares to that of the Galactic disk, we used the Expanded Very Large Array to observe radiatively excited Class II 6.7 GHz CH{sub 3}OH masers and collisionally excited Class I 44 GHz CH{sub 3}OH masers, both tracers of high-mass star formation, toward a sample of 34 Galactic center and foreground 'green' sources. We find that 33% {+-} 15% of Galactic center sources are coincident with 6.7 GHz masers, and that 44% {+-} 17% of foreground sources are coincident with 6.7 GHz masers. For 44 GHz masers, we find correlation rates of 27% {+-} 13% and 25% {+-} 13% for Galactic center green sources and foreground green sources, respectively. Based on these CH{sub 3}OH maser detection rates, as well as correlations of green sources with other tracers of star formation, such as 24 {mu}m emission and infrared dark clouds (IRDCs), we find no significant difference between the green sources in the Galactic center and those foreground to it. This suggests that once the star formation process has begun, the environmental differences between the Galactic center region and the Galactic disk have little effect on its observational signatures. We do find, however, some evidence that may support a recent episode of star formation in the Galactic center region.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvements to sample processing and measurement to enable more widespread environmental application of tritium

Previous measurements have demonstrated the wealth of information that tritium (T) can provide on environmentally relevant processes. We present modifications to sample preparation approaches that enable T measurement by proportional counting on small sample sizes equivalent to 120 mg of water and demonstrate the accuracy of these methods on a suite of standardized water samples. This enhanced method should provide the analytical flexibility needed to address persistent knowledge gaps in our understanding of T behavior in the environment.

low background↗