Search NASA⌕ Search

SEARCH · Search NASA

Results for “Environmental Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Characterizing The Mechanical Properties of Polyurethane Foams

The Department of Energy has many radioactive facilities that are on the path of deactivation and decommissioning (D and D). These facilities can sit cold and dark for many years before final disposition, and must be maintained to ensure no radiological release occurs in the interim. Improvements and additions to D and D tool sets can greatly: Save time and money, Reduce worker risk. Conventional fixatives widely used often take the form of paints or films that are not readily applicable to 3-dimensional void spaces. Foams are one promising platform that may offer solutions to a number of contaminated problem sets such as: Gloveboxes, Pipes, Tanks. SRNL is working to characterize various commercial foams that would encapsulate the interior volume of a given space and are capable of immobilizing any remaining contamination. One key performance metric of these foams is how well they will perform in an accident scenario. To this end, SRNL is researching the mechanical properties of these foams to ensure that the material can withstand the environment of application while maintaining structural integrity. ASTM standard E3191-18 served as a guiding document for this project, outlining the requirements that foaming fixatives used for the mitigation of radioactive contamination need to meet before being implemented. Objective: Quantification of the mechanical properties of 6 commercial polyurethane foams was performed using multiple ASTM standards to record measurements for: Compression testing: Flexible Foams, Force required to produce 50% compression, Rigid Foams, Compressive and apparent modulus, Point of 10% core deformation, The 'Zero Deformation' point, Compressive strength, Yield point. Tensile testing: Tensile strength, Tensile stress, Percent elongation. Experiment 1: An electromechanical compressive tester (MTS Criterion Series 43) was used to evaluate 6 foams (4 flexible, 2 rigid). Per ASTM D1621, each rigid foam was compressed at 10% of the measured thickness per minute until the sample was 13% of it's original thickness. Per ASTM D35/4, each flexible foam was pre-flexed twice to 80% original thickness at a rate of 250 mm/min, then compressed to 80% original thickness at a rate of 50 mm/min. Experiment 2: An electromechanical tensile tester (MTS Criterion Series 43) was used to evaluate 6 foams (4 flexible, 2 rigid). Per ASTM D1623, rigid foams were pulled apart at a rate of 1.27 mm/min until the sample broke. Per ASTM D35/4, flexible foams were pulled apart at a rate of 500 mm/min until the sample broke. The strongest material in both compression and tensile testing scenarios was found to be the rigid intumescent polyurethane Hilti foam. The experiments revealed that the Hilti foam in a tensile scenario had a peak stress value that was larger than the closest competitor by a factor of 2.3 and a compressive yield point that was larger than the closest competitor by a factor of 1.4, indicating that the Hilti foam is the best choice for implementation in mechanically harsh environments. The performance metrics measured can serve as a basis for future mechanical tests that would help set relevant ASTM standards (E3191) for intumescent polyurethane foams in fixating applications. Tests like surface adhesion, impact, and flame tests would serve as a better indicator as to how this material would perform in environmentally harsh scenarios often found in decommissioned nuclear facilities. Further tests of the foams' intumescent properties would also be important should these foams be implemented in environmentally harsh scenarios.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2016 Annual Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Ponds

This report describes conditions and information, as required by the state of Idaho, Department of Environmental Quality Reuse Permit I-161-02, for the Advanced Test Reactor Complex Cold Waste Ponds located at Idaho National Laboratory from November 1, 2015–October 31, 2016. The effective date of Reuse Permit I-161-02 is November 20, 2014 with an expiration date of November 19, 2019. This report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Permit required groundwater monitoring data • Status of compliance activities • Issues • Discussion of the facility’s environmental impacts. During the 2016 permit year, 180.99 million gallons of wastewater were discharged to the Cold Waste Ponds. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest in well USGS-065, which is the closest downgradient well to the Cold Waste Ponds. Sulfate and total dissolved solids concentrations decrease rapidly as the distance downgradient from the Cold Waste Ponds increases. Although concentrations of sulfate and total dissolved solids are significantly higher in well USGS-065 than in the other monitoring wells, both parameters remained below the Ground Water Quality Rule Secondary Constituent Standards in well USGS-065. The facility was in compliance with the Reuse Permit during the 2016 permit year.

2016 Annual Reuse Report for the Idaho National La↗

PHASE II VAULT TESTING OF THE ARGONNE RFID SYSTEM

The U.S. Department of Energy (DOE) (Environmental Management [EM], Office of Packaging and Transportation [EM-45]) Packaging and Certification Program (DOE PCP) has developed a Radio Frequency Identification (RFID) tracking and monitoring system, called ARG-US, for the management of nuclear materials packages during transportation and storage. The performance of the ARG-US RFID equipment and system has been fully tested in two demonstration projects in April 2008 and August 2009. With the strong support of DOE-SR and DOE PCP, a field testing program was completed in Savannah River Site's K-Area Material Storage (KAMS) Facility, an active Category I Plutonium Storage Facility, in 2010. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault for operational testing. This latest version (Mark III) of the Argonne RFID system now has the capability to measure radiation dose and dose rate. This paper will report field testing progress of the ARG-US RFID equipment in KAMS, the operability and reliability trend results associated with the applications of the system, and discuss the potential benefits in enhancing safety, security and materials accountability. The purpose of this Phase II K Area test is to verify the accuracy of the radiation monitoring and proper functionality of the ARG-US RFID equipment and system under a realistic environment in the KAMS facility. Deploying the ARG-US RFID system leads to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including environmental condition monitoring and radiation monitoring. The successful completion of the testing program will provide field data to support a future development and testing. This will increase Operation efficiency and cost effectiveness for vault operation. As the next step (Phase II) of continued vault testing for the ARG-US system, the Savannah River Site K Area Material Storage facility has placed the ARG-US RFIDs into the 910B storage vault. Deploying the ARG-US RFID system lends to a reduced need for manned surveillance and increased inventory periods by providing real-time access to status and event history traceability, including radiation and environmental monitoring. The successful completion of the testing program will provide field data to support future development and testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Indentation size effect in unirradiated and ion-irradiated 800H steel at high temperatures

Nanoindentation is a widespread and useful method for evaluating mechanical properties at the sub-micron length scale. However, the indentation size effect remains a major obstacle to obtain meaningful macroscopic mechanical properties from small volume testing. Here, this work systematically addresses the Indentation Size Effect (ISE) phenomenon as a function of temperature and defect density in an austenitic Fe-Cr-Ni alloy (800H) to establish the baseline for nanoindentation testing of ion-irradiated alloys in environmental conditions. The 800H steel sample was irradiated with 70 MeV Fe 9+ at 450 °C to the total dose of 20.68 dpa. All samples were tested up to 300 °C in order to quantify the effect of temperature on the indentation size effect. It was found that in all cases, the ISE is less pronounced at high temperatures due to the increase of the plastic zone size. For the same grain orientation, the ISE is less pronounced in the irradiated 800H at all temperatures.

36 MATERIALS SCIENCE↗

Underground Test Area (UGTA) Sampling Plan for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nevada National Security Site, Nevada

The purpose of this groundwater sampling plan (referred to herein as “the Plan”) is to describe the approach for collecting and analyzing groundwater samples to meet the objectives of the U.S. Department of Energy (DOE), Environmental Management (EM) Nevada Program’s Underground Test Area (UGTA) Activity. The Plan is focused on the Central and Western Pahute Mesa corrective action units (CAUs 101 and 102). The remaining UGTA CAUs are in the final stage of the UGTA strategy (Closure Report [CR] stage), and monitoring requirements for these CAUs are described in their respective CRs. The Plan supersedes the Nevada National Security Site Integrated Groundwater Sampling Plan and its ensuing Record of Technical Change (ROTC) (DOE/EMNV, 2019b). The Plan is designed to ensure compliance with the UGTA Quality Assurance Plan (QAP) and its ensuing ROTC (DOE/EMNV, 2018), and the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended). The Plan is implemented by the Environmental Program Services (EPS) contractor. Implementation of the Plan provides data to complete corrective actions prescribed by the FFACO to protect the public from groundwater contaminated by historical underground nuclear testing. The Plan’s scope comprises sample collection and analysis requirements for assessing the extent of groundwater contamination from underground nuclear testing. Sampling wells located in the communities surrounding the Nevada National Security Site (NNSS) is performed by other organizations (e.g., management and operating [M&O] contractor) and is therefore not included within the Plan. The results of the community sampling are presented in the annual NNSS environmental reports.

54 ENVIRONMENTAL SCIENCES↗

Coupled high-throughput functional screening and next generation sequencing for identification of plant polymer decomposing enzymes in metagenomic libraries

Recent advances in sequencing technologies generate new predictions and hypotheses about the functional roles of environmental microorganisms. Yet, until we can test these predictions at a scale that matches our ability to generate them, most of them will remain as hypotheses. Function-based mining of metagenomic libraries can provide direct linkages between genes, metabolic traits and microbial taxa and thus bridge this gap between sequence data generation and functional predictions. Here we developed high-throughput screening assays for function-based characterization of activities involved in plant polymer decomposition from environmental metagenomic libraries. The multiplexed assays use fluorogenic and chromogenic substrates, combine automated liquid handling and use a genetically modified expression host to enable simultaneous screening of 12,160 clones for 14 activities in a total of 170,240 reactions. Using this platform we identified 374 (0.26%) cellulose, hemicellulose, chitin, starch, phosphate and protein hydrolyzing clones from fosmid libraries prepared from decomposing leaf litter. Sequencing on the Illumina MiSeq platform, followed by assembly and gene prediction of a subset of 95 fosmid clones, identified a broad range of bacterial phyla, including Actinobacteria, Bacteroidetes, multiple Proteobacteria sub-phyla in addition to some Fungi. Carbohydrate-active enzyme genes from 20 different glycoside hydrolase (GH) families were detected. Using tetranucleotide frequency (TNF) binning of fosmid sequences, multiple enzyme activities from distinct fosmids were linked, demonstrating how biochemically-confirmed functional traits in environmental metagenomes may be attributed to groups of specific organisms. Overall, our results demonstrate how functional screening of metagenomic libraries can be used to connect microbial functionality to community composition and, as a result, complement large-scale metagenomic sequencing efforts.

59 BASIC BIOLOGICAL SCIENCES↗

Leach Testing of Laboratory-Scale Melter Evaporator Condensate Cementitious Waste Forms

Cementitious waste forms immobilizing evaporated AP-105 off-gas condensate were used to determine radionuclide and contaminant leachability in deionized water over a 63-day period. The off-gas condensate was collected during the actual tank AP-105 low activity waste continuous laboratory-scale melter (LSM)) run performed in fiscal year 2018 and was then solidified as a cementitious waste form using the Cast Stone formulation (8 weight percent [wt%] ordinary Portland cement, 45 wt% class F fly ash, 47 wt% blast furnace slag). Here, using the U.S. Environmental Protection Agency Method 1315 leach testing procedure, the release rate of technetium 99 (Tc), iodine-129 (I), nitrate (NO 3 - ), and sodium (Na + ) from two Cast Stone specimens was measured. From these measurements, observed diffusivity values for each constituent were calculated and can be used in future iterations and maintenance of the Integrated Disposal Facility performance assessments. Furthermore, by testing Cast Stone specimens immobilizing off-gas produced while vitrifying actual tank waste, the results of this effort improve the technical defensibility of long-term waste form performance estimates for the Cast Stone formulation. Finally, 99 Tc distribution within a representative waste form at the end of the 63-day leach period as well as bulk mineralogy were determined using solid phase characterization methods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Test Reactor Complex Sewage Lagoon Evalua

The Advanced Test Reactor (ATR) Complex located in Butte County, Idaho at the Idaho National Laboratory (INL) has an existing evaporative wastewater system to collect and treat sanitary wastewater from the facility. The existing system includes two cells, Cell #1 has a surface area of 2.9 acres and Cell #2 has a surface area of 13.8 acres. Cell #1 incorporates a soil liner system and Cell #2 includes both a PVC geomembrane and a soil liner. In 2010, both cells were tested in accordance with Idaho Department of Environmental Quality requirements and measured seepage was within acceptable limits.

99 GENERAL AND MISCELLANEOUS↗

2020 Hyperion Infrasound Sensor Equilibration Evaluation

Sandia National Laboratories has performed testing on several Hyperion 5313A infrasound sensors in order to determine the length of time it takes for the sensors to thermally equilibrate under a variety of environmental conditions. The motivation for performing these tests is to aid in determining suitable procedures for station operators to follow when installing these sensors. The desired outcome is for the station operators to be able to determine more quickly and reliably whether the sensors are performing correctly at the time of installation.

47 OTHER INSTRUMENTATION↗

Neutronics Analysis of TREAT Multi-SERTTA Calibration Test Vehicle (Multi-SERTTA CAL)

Transient testing is a necessary step in the performance evaluation of Accident Tolerant Fuels (ATF) developed as part of the Fuel Cycle Research and Development Advanced Fuels Campaign initiated and supported by the United States Department of Energy (DOE-NE). These advanced fuels are expected to be used in future reactors or replace the current fuel design used in existing power reactors for enhanced performance and safety. Upon completion of a process proscribed by the National Environmental Policy Act, the Transient Reactor Test (TREAT) facility, located at Idaho National Laboratory (INL), was chosen by DOE-NE to provide the desired specialized testing. TREAT has successfully operated from start-up in 1959 to 1994 when it was placed on operational stand-by. Careful preparations are being made for operational readiness and TREAT is projected to resume testing no later than 2018. Past TREAT testing primarily focused on sodium-cooled reactor fuels (SRF). Test vehicle designs varied to accommodate testing needs ranging from separate effects tests to integral tests approaching simulation of actual reactor environment conditions including forced convection cooling. The current focus on light water reactor (LWR) ATF requires design of new experiment vehicles to accommodate the water/steam environment and associated complexities regarding desired energy deposition into the specimen and proper containment. The first set of experiments in TREAT restart is expected to be conducted with the Multi-SERTTA (Static Environment Rodlet Transient Test Apparatuses). Difficult to quantify and calculate integral and time dependent effects inherent in transient testing limit predictive modeling capability; therefore, calibration testing in TREAT prior to the actual experiment is necessary to empirically determine the effectiveness of core-to-specimen power coupling in order to achieve the desired energy deposition into the test specimen during a nuclear power transient. This has been done in the past, in part, by evaluating the difference in energy deposition into dosimeter wires subjected to various TREAT time dependent power conditions. These calibration tests were typically conducted in a test vehicle neutronically similar to the actual test vehicle, but more simplistic in design in order to quickly retrieve and analyze dosimeter wires and minimize containment structure costs due to several trials. Prior calibration testing for SRF experiments could be conducted without coolant as sodium has no notable neutronic effect on the core-to-specimen power coupling factor (PCF). Such is not the case with LWR fuel where water serves as both moderator and coolant. This presents a design challenge as the calibration test vehicle must retain heated, high-pressure water to preserve neutronic equivalence representative of near prototypic reactor conditions while allowing for quick retrieval of dosimeters. The solution to this challenge comes in the form of a thin walled dry well positioned through the center of the basic Multi-SERTTA design. Test vehicle reactivity worth and PCF are two important factors with respect to ascertainment of neutronic equivalence. Similarity in test vehicle reactivity worth is desired to avoid the need to change operational core rod positions in TREAT which could significantly alter neutron flux distribution and consequently power distribution throughout the core and into the test specimen. The geometry and composition of various materials within the experiment containment structure can also significantly alter the quality of neutron signal delivery from the core to the test specimen. Introduction of an Inconel tube, albeit very thin, is expected to impact PCF. Simple modifications to the CAL design may compensate for the anticipated change. Evaluation of these factors and proposed modifications through neutronics analysis serves to inform experiment design and is a valuable tool towards achieving the optimal CAL design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mercury Speciation via Direct Mercury Analyzer

Mercury has no known biological role, but is present in every living thing and widespread in the environment. As mercury enters an aqueous system, it is subject to methylation or demethylation. Methylmercury selectively partitions into biota and biomagnifies through the food chain. Nearly all methylmercury exposures in the U.S. occur through eating fish and shellfish that contain higher levels of methylmercury. Methyl mercury and other organomercury compounds are more toxic than inorganic mercury. Thus, monitoring and understanding mercury speciation are key to effective environmental management. It is particularly important to be able to separate and measure bioaccumulative-toxic species of mercury such as methyl mercury. We are developing a protocol for utilizing the Direct Mercury Analyzer (DMA-80) for mercury speciation of water samples and to monitor methylmercury (meHg). Objectives: - Advance the understanding of the performance of the direct mercury analysis (DMA) under a range of DOE relevant water chemistry conditions to quantify total mercury: - Demonstrate the applicability of DMA to analysis of typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Test innovative sorbents to extend the range of the direct mercury analyzer to environmental concentration levels. - Perform scoping tests to demonstrate proof of principle for the chemical reduction amalgamation modular microcolumns for mercury speciation: Examine various microcolumn configurations and document speciation performance for typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Perform tests to examine extending the speciation paradigm to environmental concentration levels. General Method: all samples analyzed using a direct mercury analyzer (DMA 80) which automates the following steps: 1) pyrolysis to release the mercury, 2) catalysis to convert all mercury to elemental, 3) amalgamation to trap the mercury, 4) desorption to release the mercury as a pulse and 5) spectroscopy to detect the mercury.. Instrument analyzes all mercury species in solids and liquids. The DMA 'eliminates' sample preparation, reduces labor, decreases waste, and results in more practical and cost effective methods. To test the performance of the DMA for DOE relevant conditions, we analyzed samples representative of at high (mg/L) tank waste concentrations in water and in diluted tank waste simulant and analyzed samples representative of environmental (ng/L levels) in water. High concentration samples were analyzed directly in the instrument. Low concentration samples were analyzed by concentrating the mercury onto sorbents such as silica thiol or a mixture of silica thiol and copper. The concentration was performed using microcolumns and placing the columns into the DMA (see below) or by mixing the sorbent into the bulk sample and then filtering ad analyzing the filter in the DMA. Speciation Methods: The speciation tests were based on the selective reduction of inorganic mercury ions - Hg{sup (+} {sup or} {sup 2+)} - to elemental mercury - Hg(0). The elemental mercury is then trapped by amalgamation into the metal. These reactions do not impact methyl mercury allowing for separation. All reactions were performed using powdered elemental copper. To demonstrate proof-of-principle for the selective collection of inorganic mercury, samples were exposed to different amounts of powdered copper (and a control with no copper). This was done using microcolumns and a vacuum box. The columns were placed directly on the DMA for analysis. All materials and conditions were tested using solutions of both inorganic mercury and methyl mercury and all trials were in triplicate. Results and Observations: Validated DMA for high concentration Hg samples such as DOE tank waste: - Liquid inHg - samples were stable on autosampler carousel and results were accurate; - Liquid meHg - samples required a stabilizer. Si-Thiol (0.02 g) in the sample boat generated reliable meHg results. Stabilizer can be added for routine operations. Successful 'proof of principal' in extending DMA range to near environmental levels - using both microcolumns and filtration; - Filtration - Adding Si-Thiol (0.5 g) to sample extracted both inHg and meHg and preserved sample. Handling filters was labor intensive. - Microcolumns - best performance using a combination of copper and Si-Thiol - columns clogged and flowed slowly in some cases; - Practical limit may be in the range of 1 to 5 ng/L due to blanks; - Path Forward - Test additional packing materials and methods to improve flow and consistency, and approaches to minimize blanks. Successful 'proof of principal' for Hg speciation using chemical reduction and amalgamation; - Copper microcolumns (0.5 g Cu) selectively trapped inHg for high concentration mercury samples; - Copper microcolumns (0.5 g Cu selectively trapped inHg for large volume samples at environmental concentrations; - Some sorption of me Hg so that separations not quantitative; - Path Forward - test additional packing materials and alternate eluents to better trap inHg and minimize meHg retention in column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emergency Planning and Preparedness, Mission Support and Test Services

This presentation is for the Community Environmental Monitoring Program (CEMP), comprising a network of monitoring stations located in communities surrounding and downwind of the Nevada National Security Site (NNSS) that monitor the airborne and groundwater environments for manmade radioactivity that could result from NNSS activities. The CEMP is a collaborative effort of the Department of Energy's National Nuclear Security Administration Nevada Field Office (NNSA/NFO), and the Desert Research Institute (DRI) of the Nevada System of Higher Education.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pilot Test Remediation of a Fractured Bedrock Aquifer at the Maywood Superfund Site, Maywood, New Jersey - 19217

The U.S. Army Corps of Engineers (USACE) and Cabrera Services are conducting a Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) Pilot Test treatment of a fractured bedrock aquifer at the Formerly Utilized Sites Remedial Action Program (FUSRAP) Maywood Superfund Site (FMSS) located in Maywood, New Jersey (NJ), USA. The Maywood Chemical Company Superfund Site in Bergen County, NJ is listed on the United States Environmental Protection Agency (USEPA) Superfund National Priorities List (NPL). The National Superfund Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) identification number is NJD980529762. The Maywood Chemical Company Superfund Site (hereafter referred to as the FMSS) consists of 92 designated properties in the communities of Maywood, Lodi and Rochelle Park, NJ. These are collectively known as FMSS 'Vicinity Properties' and include property owned by the federal government (the Maywood Interim Storage Site, or MISS); the Stepan Company (former location of the Maywood Chemical Works, or MCW); 62 residential properties; three properties owned by the state or federal government; four municipal properties; and 21 commercial properties. The Stepan Company property includes contaminated buildings and three remediated U.S. Nuclear Regulatory Commission (NRC) licensed burial pits; the MISS also includes a contaminated building. Contamination on the FMSS is being addressed under three separate actions coordinated by the lead regulator USEPA Region 2. The USACE is addressing thorium (Th) and other wastes at the site defined as 'FUSRAP waste' in the Soils and Buildings and Groundwater Records of Decision (ROD) for the FMSS. Stepan Company is addressing other chemical wastes (non-FUSRAP waste) at the FMSS. The Groundwater ROD [1] was signed into agreement by USACE Division Commander in June 2012 and USEPA Region 2 Administrator in July 2012 and presents the selected remedial actions for Operable Unit (OU) 2 groundwater at the MISS and adjacent properties. The selected remedial action is removal of non-radiologically contaminated soils on the MISS containing arsenic, lithium, and benzene with concentrations above cleanup levels, and monitored natural attenuation (MNA) of arsenic, lithium, and benzene in groundwater. In situ treatment of arsenic in the overburden aquifer using oxidation reduction (redox) alteration will also be performed if needed to meet the groundwater cleanup levels after the source soil is removed. The need for in situ treatment will be determined during the Groundwater ROD review at least three to four years after the contaminated source soil removal is completed. The third action addressing non-FUSRAP chemical wastes will be the responsibility of the Stepan Company as a primary responsible party in this action. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pilot Test Remediation of a Fractured Bedrock Aquifer at the Maywood Superfund Site, Maywood, New Jersey - 20073

The U.S. Army Corps of Engineers (USACE) and Cabrera Services are conducting a Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) Pilot Test treatment of a fractured bedrock aquifer at the Formerly Utilized Sites Remedial Action Program (FUSRAP) Maywood Superfund Site (FMSS) located in Maywood, New Jersey (NJ), USA. The Maywood Chemical Company Superfund Site in Bergen County, NJ is listed on the United States Environmental Protection Agency (USEPA) Superfund National Priorities List (NPL). The National Superfund Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) identification number is NJD980529762. The Maywood Chemical Company Superfund Site (hereafter referred to as the FMSS) consists of 92 designated properties in the communities of Maywood, Lodi and Rochelle Park, NJ. These are collectively known as FMSS 'Vicinity Properties' and include property owned by the federal government (the Maywood Interim Storage Site, or MISS); the Stepan Company (former location of the Maywood Chemical Works, or MCW); 62 residential properties; three properties owned by the state or federal government; four municipal properties; and 21 commercial properties. The Stepan Company property includes contaminated buildings and three remediated U.S. Nuclear Regulatory Commission (NRC) licensed burial pits; the MISS also includes a contaminated building. Contamination on the FMSS is being addressed under three separate actions coordinated by the lead regulator USEPA Region 2. The USACE is addressing thorium (Th) and other wastes at the site defined as 'FUSRAP waste' in the Soils and Buildings and Groundwater Records of Decision (ROD) for the FMSS. Stepan Company is addressing other chemical wastes (non-FUSRAP waste) at the FMSS. The Groundwater ROD [1] was signed into agreement by USACE Division Commander in June 2012 and USEPA Region 2 Administrator in July 2012 and presents the selected remedial actions for Operable Unit (OU) 2 groundwater at the MISS and adjacent properties. The selected remedial action is removal of non-radiologically contaminated soils on the MISS containing arsenic, lithium, and benzene with concentrations above cleanup levels, and monitored natural attenuation (MNA) of arsenic, lithium, and benzene in groundwater. In situ treatment of arsenic in the overburden aquifer using oxidation reduction (redox) alteration will also be performed if needed to meet the groundwater cleanup levels after the source soil is removed. The need for in situ treatment will be determined during the Groundwater ROD review at least three to four years after the contaminated source soil removal is completed. The third action addressing non-FUSRAP chemical wastes will be the responsibility of the Stepan Company as a primary responsible party in this action. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of low-cost monitors to assess household air pollution

Highlights: • We assessed PM{sub 2.5} and CO low-cost monitors in semi-controlled and field studies. • Devices experienced high failure rate and susceptibility to environmental changes. • Low-cost monitors tested may not be ready to replace more established methods. Exposure to household air pollution is a leading cause of morbidity and mortality globally. However, due to the lack of validated low-cost monitors with long-lasting batteries in indoor environments, most epidemiologic studies use self-reported data or short-term household air pollution assessments as proxies of long-term exposure. We evaluated the performance of three low-cost monitors measuring fine particulate matter (PM{sub 2.5}) and carbon monoxide (CO) in a wood-combustion experiment conducted in one household of Spain for 5 days (including the co-location of 2 units of HAPEX and 3 units of TZOA-R for PM{sub 2.5} and 3 units of EL-USB-CO for CO; a total of 40 unit-days). We used Spearman correlation (ρ) and Concordance Correlation Coefficient (CCC) to assess accuracy of low-cost monitors versus equivalent research-grade devices. We also conducted a field study in India for 1 week (including HAPEX in 3 households and EL-USB-CO in 4 households; a total of 49 unit-days). Correlation and agreement at 5-min were moderate-high for one unit of HAPEX (ρ = 0.73 / CCC = 0.59), for one unit of TZOA-R (ρ = 0.89 / CCC = 0.62) and for three units of EL-USB-CO (ρ = 0.82–0.89 / CCC = 0.66–0.91) in Spain, although the failure or malfunction rate among low-cost units was high in both settings (60% of unit-days in Spain and 43% in India). Low-cost monitors tested here are not yet ready to replace more established exposure assessment methods in long-term household air pollution epidemiologic studies. More field validation is needed to assess evolving sensors and monitors with application to health studies.

54 ENVIRONMENTAL SCIENCES↗

Challenges in studying water fluxes within the soil-plant-atmosphere continuum: A tracer-based perspective on pathways to progress

Tracing and quantifying water fluxes in the hydrological cycle is crucial for understanding the current state of ecohydrological systems and their vulnerability to environmental change. Especially the interface between ecosystems and the atmosphere that is strongly mediated by plants is important to meaningfully describe ecohydrological system functioning. Many of the dynamic interactions generated by water fluxes between soil, plant and the atmosphere are not well understood, which is partly due to a lack of interdisciplinary research. This opinion paper reflects the outcome of a discussion among hydrologists, plant ecophysiologists and soil scientists on open questions and new opportunities for collaborative research on the topic "water fluxes in the soil-plant-atmosphere continuum" especially focusing on environmental and artificial tracers. We emphasize the need for a multi-scale experimental approach, where a hypothesis is tested at multiple spatial scales and under diverse environmental conditions to better describe the small-scale processes (i.e., causes) that lead to large-scale patterns of ecosystem functioning (i.e., consequences). Novel in-situ, high-frequency measurement techniques offer the opportunity to sample data at a high spatial and temporal resolution needed to understand the underlying processes. Here we advocate for a combination of long-term natural abundance measurements and event-based approaches. Multiple environmental and artificial tracers, such as stable isotopes, and a suite of experimental and analytical approaches should be combined to complement information gained by different methods. Virtual experiments using process-based models should be used to inform sampling campaigns and field experiments, e.g., to improve experimental designs and to simulate experimental outcomes. On the other hand, experimental data are a pre-requisite to improve our currently incomplete models. Interdisciplinary collaboration will help to overcome research gaps that overlap across different earth system science fields and help to generate a more holistic view of water fluxes between soil, plant and atmosphere in diverse ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Transport spatial model for the definition of green routes for city logistics centers

This paper presents a transport spatial decision support model (TSDSM) for carrying out the optimization of green routes for city logistics centers. The TSDSM model is based on the integration of the multi-criteria method of Weighted Linear Combination (WLC) and the modified Dijkstra algorithm within a geographic information system (GIS). The GIS is used for processing spatial data. The proposed model makes it possible to plan routes for green vehicles and maximize the positive effects on the environment, which can be seen in the reduction of harmful gas emissions and an increase in the air quality in highly populated areas. The scheduling of delivery vehicles is given as a problem of optimization in terms of the parameters of: the environment, health, use of space and logistics operating costs. Each of these input parameters was thoroughly examined and broken down in the GIS into criteria which further describe them. The model presented here takes into account the fact that logistics operators have a limited number of environmentally friendly (green) vehicles available. The TSDSM was tested on a network of roads with 127 links for the delivery of goods from the city logistics center to the user. The model supports any number of available environmentally friendly or environmentally unfriendly vehicles consistent with the size of the network and the transportation requirements. - Highlights: • Model for routing light delivery vehicles in urban areas. • Optimization of green routes for city logistics centers. • The proposed model maximizes the positive effects on the environment. • The model was tested on a real network.

54 ENVIRONMENTAL SCIENCES↗

Final Report Feasibility Study for the California Wave Energy Test Center (CalWavesm)

The California Wave Energy Test Center (CalWave) Feasibility Study project was funded over multiple phases by the Department of Energy to perform an interdisciplinary feasibility assessment to analyze the engineering, permitting, and stakeholder requirements to establish an open water, fully energetic, grid connected, wave energy test center off the coast of California for the purposes of advancing U.S. wave energy research, development, and testing capabilities. Work under this grant included wave energy resource characterization, grid impact and interconnection requirements, port infrastructure and maritime industry capability/suitability to accommodate the industry at research, demonstration and commercial scale, and macro and micro siting considerations. CalWave Phase I performed a macro-siting and down-selection process focusing on two potential test sites in California: Humboldt Bay and Vandenberg Air Force Base. This work resulted in the Vandenberg Air Force Base site being chosen as the most favorable site based on a peer reviewed criteria matrix. CalWave Phase II focused on four siting location alternatives along the Vandenberg Air Force Base coastline and culminated with a final siting down-selection. Key outcomes from this work include completion of preliminary engineering and systems integration work, a robust turnkey cost estimate, shoreside and subsea hazards assessment, storm wave analysis, lessons learned reports from several maritime disciplines, test center benchmarking as compared to existing international test sites, analysis of existing applicable environmental literature, the completion of a preliminary regulatory, permitting and licensing roadmap, robust interaction and engagement with state and federal regulatory agency personnel and local stakeholders, and the population of a Draft Federal Energy Regulatory Commission (FERC) Preliminary Application Document (PAD). Analysis of existing offshore oil and gas infrastructure was also performed to assess the potential value and re-use scenarios of offshore platform infrastructure and associated subsea power cables and shoreside substations. The CalWave project team was well balanced and was comprised of experts from industry, academia, state and federal regulatory agencies. The result of the CalWave feasibility study finds that the CalWave Test Center has the potential to provide the most viable path to commercialization for wave energy in the United States.

16 TIDAL AND WAVE POWER↗