Search NASA⌕ Search

SEARCH · Search NASA

Results for “Explosive detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

COBE - Explorer of the primeval explosion

The Cosmic Background Explorer satellite will measure the diffuse microwave and infrared emission from the universe over the entire wavelength range from a few microns to 13 mm with unprecedented sensitivity and accuracy. It will measure the spectrum and angular distribution of the cosmic background radiation thought to be remnant of the big bang explosion, and it may also detect the radiation produced by the primal stars and galaxies. Furthermore, it will gather a large body of data permitting detailed study of the distribution, spectra, and temperature of the interstellar and interplanetary dust.

Mather, J. C.↗

Detecting Space Dust Particles

Technique records times specific craters formed in targets exposed in space and permits determination of direction in which impacting particles traveled at times of impacts. MOS capacitor is short-circuited by impact of particle striking at high speed. After recovery of targets from space, compositions of impacting particles established through post-flight laboratory analyses of residual materials in craters. On earth technique has industrial and military uses in detection of fragments driven by explosions. Studies of orbital dynamics of particles produced by solid-propellant rocket-motor firings in space made using technique.

Kinard, William H.↗

Detection of small molecules with a flow immunosensor

We describe the development of an easy-to-use sensor with widespread applications for detecting small molecules. The flow immunosensor can analyze discrete samples in under one minute or continuously monitor a flowing stream for the presence of specific analytes. This detection system is extremely specific, and achieves a level of sensitivity which meets or exceeds the detection limits reported for rival assays. Because the system is also compact, transportable, and automated, it has the potential to impact diverse areas. For example, the flow immunosensor has successfully detected drugs of abuse and explosives, and may well address many of the needs of the environmental community with respect to continuous monitoring for pollutants. Efforts are underway to engineer a portable device in the field.

Kusterbeck, Anne W.↗

Chemochromic Hydrogen Sensors

As fossil fuel supplies decline, hydrogen is quickly becoming an increasingly important fuel source. Currently hydrogen is the prime fuel of today's space vehicles (e.g., Space Shuttle) and featured as a fuel for some prototype vehicles such as the BMW seven series model. Hydrogen is a colorless, odorless gas with a 4% lower explosive limit which makes leak detection a priority. In an effort to support the use of hydrogen, a chemochromic (color changing) sensor was developed that is robust, simple to use, and does not require active operation. It can be made into a thin tape which can be conveniently used for leak detection at flanges, valves, or outlets. Chemochromic sensors can be either reversible or irreversible; however, irreversible chemochromic sensors will be analyzed in this report. The irreversible sensor is useful during hazardous operations when personnel cannot be present. To actively monitor leaks, testing of the irreversible sensor against environmental effects was completed and results indicated this material is suitable for outdoor use in the harsh beachside environment of Kennedy Space Center. The experiments in this report will give additional results to the environmental testing by adding solid rocket booster residue as a variable. The primary motivation for these experiments is to prepare the sensors for the launch pad environment at the Kennedy Space Center. In an effort to simulate the atmosphere at the pads before and after launch, the chemochromic sensors are exposed to solid rocket residue under various conditions.

Wiggins, Bryan C.↗

Luminescent detection of hydrazine and hydrazine derivatives

The present invention generally relates to methods for modulating the optical properties of a luminescent polymer via interaction with a species (e.g., an analyte). In some cases, the present invention provides methods for determination of an analyte by monitoring a change in an optical signal of a luminescent polymer upon exposure to an analyte. Methods of the present invention may be useful for the vapor phase detection of analytes such as explosives and toxins. The present invention also provides methods for increasing the luminescence intensity of a polymer, such as a polymer that has been photobleached, by exposing the luminescent polymer to a species such as a reducing agent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational screening of large molecule adsorption by metal-organic frameworks.

Grand canonical Monte Carlo simulations were performed to investigate trends in low-pressure adsorption of a broad range of organic molecules by a set of metal-organic frameworks (MOFs). The organic analytes considered here are relevant to applications in chemical detection: small aromatics (o-, m-, and p-xylene), polycyclic aromatic hydrocarbons (naphthalene, anthracene, phenanthrene), explosives (TNT and RDX), and chemical warfare agents (GA and VM). The framework materials included several Zn-MOFs (IRMOFs 1-3, 7, 8), a Cr-MOF (CrMIL-53lp), and a Cu-MOF (HKUST-1). Many of the larger organics were significantly adsorbed by the target MOFs at low pressure, which is consistent with the exceptionally high isosteric heats of adsorption (25 kcal/mol - 60 kcal/mol) for this range of analyte. At a higher loading pressure of 101 kPa, the Zn-MOFs show a much higher volumetric uptake than either CrMIL-53-lp or HKUST-1 for all types of analyte. Within the Zn-MOF series, analyte loading is proportional to free volume, and loading decreases with increasing analyte size due to molecular packing effects. CrMIL-53lp showed the highest adsorption energy for all analytes, suggesting that this material may be suitable for low-level detection of organics.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Chemochromic Hydrogen Leak Detectors

At NASA, hydrogen safety is a key concern for space shuttle processing. Leaks of any level must be quickly recognized and addressed due to hydrogen s lower explosion limit. Chemo - chromic devices have been developed to detect hydrogen gas in several embodiments. Because hydrogen is odorless and colorless and poses an explosion hazard, there is an emerging need for sensors to quickly and accurately detect low levels of leaking hydrogen in fuel cells and other advanced energy- generating systems in which hydrogen is used as fuel. The device incorporates a chemo - chromic pigment into a base polymer. The article can reversibly or irreversibly change color upon exposure to hydrogen. The irreversible pigment changes color from a light beige to a dark gray. The sensitivity of the pigment can be tailored to its application by altering its exposure to gas through the incorporation of one or more additives or polymer matrix. Furthermore, through the incorporation of insulating additives, the chemochromic sensor can operate at cryogenic temperatures as low as 78 K. A chemochromic detector of this type can be manufactured into any feasible polymer part including injection molded plastic parts, fiber-spun textiles, or extruded tapes. The detectors are simple, inexpensive, portable, and do not require an external power source. The chemochromic detectors were installed and removed easily at the KSC launch pad without need for special expertise. These detectors may require an external monitor such as the human eye, camera, or electronic detector; however, they could be left in place, unmonitored, and examined later for color change to determine whether there had been exposure to hydrogen. In one type of envisioned application, chemochromic detectors would be fabricated as outer layers (e.g., casings or coatings) on high-pressure hydrogen storage tanks and other components of hydrogen-handling systems to provide visible indications of hydrogen leaks caused by fatigue failures or other failures in those systems. In another type of envisioned application, chemochromic detectors of this type could be optoelectronically instrumented for monitoring to provide measured digital indications of color changes indicative of the presence of hydrogen.

Roberson, Luke↗

Origin of a signal detected with the LSD detector after the accident at the chernobyl nuclear power plant

A rare signal was detected at 23:53 Moscow time on April 27, 1986 with the LSD low-background scintillation detector located under Mont Blanc at a distance of 1820 km from Chernobyl. To reveal the origin of this signal, we discuss the results obtained with other instruments operating within a similar program, as well as analyze the characteristics of the pulses of the signal and facts referring to the explosion of the Chernobyl reactor. A hypothesis based on detection with the LSD of gamma-quanta from {beta} decays of {sup 135}I nuclei ejected into atmosphere by the reactor explosion and carried in the underground detector camera with air of positive ventilation is considered. The explosion origin of the LSD signal indicates a new technogenic source of the background in the search for neutrino bursts from cores of collapsing stars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Landmines by Neutron Backscattering: Effects of Soil Moisture on the Detection System

Detection of buried land mines by using neutron backscattering technique (NBS) is a well established method. It depends on detecting a hydrogen anomaly in dry soil. Since a landmine and its plastic casing contain much more hydrogen atoms than the dry soil, this anomaly can be detected by observing a rise in the number of neutrons moderated to thermal or epithermal energy. But, the presence of moisture in the soil limits the effectiveness of the measurements. In this work, a landmine detection system using the NBS technique was designed. A series of Monte Carlo calculations was carried out to determine the limits of the system due to the moisture content of the soil. In the simulations, an isotropic fast neutron source ({sup 252}Cf, 100 mug) and a neutron detection system which consists of five {sup 3}He detectors were used in a practicable geometry. In order to see the effects of soil moisture on the efficiency of the detection system, soils with different water contents were tested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility Spectrometry (IMS) and Mass Spectrometry

In a media of finite viscosity, the Coulomb force of external electric field moves ions with some terminal speed. This dynamics is controlled by “mobility” - a property of the interaction potential between ions and media molecules. This fact has been used to separate and characterize gas-phase ions in various modes of ion mobility spectrometry (IMS) developed since 1970. Commercial IMS devices were introduced in 1980-s for field detection of volatile traces such as explosives and chemical warfare agents. Coupling to soft-ionization sources, mass spectrometry (MS), and chromatographic methods in 1990-s had allowed IMS to handle complex samples, enabling new applications in biological and environmental analyses, nanoscience, and other areas. Since 2003, the introduction of commercial systems by major instrument vendors started bringing the IMS/MS capability to broad user community. The other major development of last decade has been the differential IMS or “field asymmetric waveform IMS” (FAIMS) that employs asymmetric time-dependent electric field to sort ions not by mobility itself, but by the difference between its values in strong and weak electric fields. Coupling of FAIMS to conventional IMS and stacking of conventional IMS stages have enabled two-dimensional separations that dramatically expand the power of ion mobility methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the central engine of long gamma-ray bursts and hypernovae with gravitational waves and neutrinos

There are the two common candidates as the viable energy source for the central engine of long gamma-ray bursts (GRBs) and hypernovae (HNe), neutrino annihilation and magnetic fields. We investigate gravitational wave (GW) emission accompanied by these two mechanisms. Especially, we focus on GW signals produced by neutrinos from a hyper-accreting disk around a massive black hole. We show that neutrino-induced GWs are detectable for {approx}1 Mpc events by LISA and {approx}100 Mpc by DECIGO/BBO, if the central engine is powered by neutrinos. The GW signals depend on the viewing angle and they are anticorrelated with neutrino ones. But, simultaneous neutrino detections are also expected, and helpful for diagnosing the explosion mechanism when later electromagnetic observations enable us to identify the source. GW and neutrino observations are potentially useful for probing choked jets that do not produce prompt emission, as well as successful jets. Even in nondetection cases, observations of GWs and neutrinos could lead to profitable implications for the central engine of GRBs and HNe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Residual Explosives by Swab Touch Spray Ionization Mass Spectrometry

Swab touch spray ionization mass spectrometry, an ambient ionization technique, has been applied to the analysis of six explosives from various surfaces including glass, metal, Teflon, plastic, human hands and three types of gloves (nitrile, vinyl and latex). A swab, attached to a metallic handle, was used to sample explosive residues and acted as the ion source. The explosives, 1,3,5-trinitro-1,3,5-triazinane (RDX), 1,3,5,7-tetranitro-1,3,5,7-tetrazocane (HMX), and 2,2-bis[(nitrooxy)methyl]propane-1,3-diyl dinitrate (PETN) had an absolute limit of detection of 10 ng from all the surfaces except for PETN from the nitrile gloves (limit of detection 100 ng). Sodium perchlorate, 2-methyl-1,3,5-trinitrobenzene (TNT) and tetra-butylammonium perchlorate had limits of detection of 100 pg, 10 pg, and 1 pg, respectively from all surfaces. This study demonstrates the feasibility of swab touch spray ionization mass spectrometry for detection of a wide array of explosives from a variety of forensically applicable surfaces with disposable, commercial, tamperproof and individually-wrapped conductive swabs without complicated/lengthy sample preparations or extractions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of Anomalous Gamma-Ray Spectra for On-Site Inspection

This work aims to solve some of the technical and logistical challenges inherent in performing On Site Inspection activities under the authority of the Comprehensive Nuclear-Test-Ban Treaty. Inspectors require equipment that can reliably identify the radionuclide signatures of nuclear test explosions amid a background of environmental contamination. Detection of these radiation anomalies by mobile search teams in the air or on the ground can narrow the search field and target specific areas for more detailed inspection or sampling. The need to protect confidential information of the inspected State Party, especially regarding past nuclear testing activities, suggests that full access to measured gamma-ray spectra should be limited. Spectral blinding techniques---in which only a fraction of the information derived from the spectra is displayed and stored---have the potential to meet the needs of both the OSI team and the State Party. In this paper, we describe one such algorithm that we have developed for identifying anomalous spectra from handheld, mobile, or aerial sensors. The algorithm avoids potential sensitivities by reducing the gamma-ray spectrum into a single number that is displayed and stored. A high value indicates that the spectrum is anomalous. The proposed technique does not rely on identifying specific radionuclides, operates well in the presence of high background variability, and can be configured to ignore specific spectral components. In previous work, the algorithm has proven very effective in classifying gamma-ray spectra as anomalous or not, even with poor statistical information. We performed a limited simulation of an airborne search scenario to demonstrate the potential algorithm for OSI missions. The technique successfully detected an injected source of interest whose count rate was an order of magnitude below background levels. We also configured the algorithm to ignore 137Cs as irrelevant to the mission. The resulting alarm metrics were unaffected by the presence of injected 137Cs contamination.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ancho Canyon RF Collect, March 2, 2017: Final Report

We report the results from the March 2, 2017, Ancho Canyon RF collection. While bright electromagnetic signals were seen nearby the firing point, there were no detections of signals from the explosively-fired fuse at a collection point about 570m distant on the East Mesa. However, "liveness" tests of the East Mesa data acquisition system and checks of the timing both suggest that the collection system was working correctly. We examine possible reasons for the lack of detection. Principal among these is that the impulsive signal may be small compared to the radio frequency background on the East Mesa.

47 OTHER INSTRUMENTATION↗

Predicting the performance of local seismic networks using Matlab and Google Earth.

We have used Matlab and Google Earth to construct a prototype application for modeling the performance of local seismic networks for monitoring small, contained explosions. Published equations based on refraction experiments provide estimates of peak ground velocities as a function of event distance and charge weight. Matlab routines implement these relations to calculate the amplitudes across a network of stations from sources distributed over a geographic grid. The amplitudes are then compared to ambient noise levels at the stations, and scaled to determine the smallest yield that could be detected at each source location by a specified minimum number of stations. We use Google Earth as the primary user interface, both for positioning the stations of a hypothetical local network, and for displaying the resulting detection threshold contours.

99 GENERAL AND MISCELLANEOUS↗

Radio Emission from Supernovae

Study of radio supernovae over the past 27 years includes more than three dozen detected objects and more than 150 upper limits. From this work it is possible to identify classes of radio properties, demonstrate conformance to and deviations from existing models, estimate the density and structure of the circumstellar material and, by inference, the evolution of the presupernova stellar wind, and reveal the last stages of stellar evolution before explosion. It is also possible to detect ionized hydrogen along the line of sight, to demonstrate binary properties of the presupernova stellar system, and to detect dumpiness of the circumstellar material.

79 ASTRONOMY AND ASTROPHYSICS↗

Expectations for the hard x-ray continuum and gamma-ray line fluxes from the typE IA supernova SN 2014J in M82

The hard X-ray continuum and gamma-ray lines from a Type Ia supernova dominate its integrated photon emissions and can provide unique diagnostics of the mass of the ejecta, the {sup 56}Ni yield and spatial distribution, its kinetic energy and expansion speed, and the mechanism of explosion. Such signatures and their time behavior 'X-ray' the bulk debris field in direct fashion, and do not depend on the ofttimes problematic and elaborate UV, optical, and near-infrared spectroscopy and radiative transfer that have informed the study of these events for decades. However, to date no hard photons have ever been detected from a Type Ia supernova in explosion. With the advent of the supernova SN 2014J in M82, at a distance of ∼3.5 Mpc, this situation may soon change. Both NuSTAR and INTEGRAL have the potential to detect SN 2014J, and, if spectra and light curves can be measured, would usefully constrain the various explosion models published during the last ∼30 yr. In support of these observational campaigns, we provide predictions for the hard X-ray continuum and gamma-line emissions for 15 Type Ia explosion models gleaned from the literature. The model set, containing as it does deflagration, delayed detonation, merger detonation, pulsational delayed detonation, and sub-Chandrasekhar helium detonation models, collectively spans a wide range of properties, and hence signatures. We provide a brief discussion of various diagnostics (with examples), but importantly make the spectral and line results available electronically to aid in the interpretation of the anticipated data.

79 ASTRONOMY AND ASTROPHYSICS↗

Printable sensors for explosive detonation

Here, we report the development of an organic thin film transistor (OTFT) based on printable solution processed polymers and employing a quantum tunnelling composite material as a sensor to convert the pressure wave output from detonation transmission tubing (shock tube) into an inherently amplified electronic signal for explosives initiation. The organic electronic detector allows detection of the signal in a low voltage operating range, an essential feature for sites employing live ordinances that is not provided by conventional electronic devices. We show that a 30-fold change in detector response is possible using the presented detector assembly. Degradation of the OTFT response with both time and repeated voltage scans was characterised, and device lifetime is shown to be consistent with the requirements for on-site printing and usage. The integration of a low cost organic electronic detector with inexpensive shock tube transmission fuse presents attractive avenues for the development of cheap and simple assemblies for precisely timed initiation of explosive chains.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗