An intelligent data acquisition system for fluid mechanics research

This paper describes a novel data acquisition system for use with wind-tunnel probe-based measurements, which incorporates a degree of specific fluid dynamics knowledge into a simple expert system-like control program. The concept was developed with a rudimentary expert system coupled to a probe positioning mechanism operating in a small-scale research wind tunnel. The software consisted of two basic elements, a general-purpose data acquisition system and the rulebased control element to take and analyze data and supplying decisions as to where to measure, how many data points to take, and when to stop. The system was validated in an experiment involving a vortical flow field, showing that it was possible to increase the resolution of the experiment or, alternatively, reduce the total number of data points required, to achieve parity with the results of most conventional data acquisition approaches.

Cantwell, E. R.↗

Sizing of colloidal particle and protein molecules in a hanging fluid drop

We report non-invasive particle size measurements of polystyrene latex colloidal particles and bovine serum albumin (BSA) protein molecules suspended in tiny hanging fluid drops of 30 micro-Liter volume using a newly designed fiber optic probe. The probe is based upon the principles of the technique of dynamic light scattering (DLS). The motivation for this work comes from growing protein crystals in outer space. Protein crystals have been grown previously in hanging drops in microgravity experiments on-board the space shuttle orbiter. However, obtaining quantitative information on nucleation and growth of the protein crystals in real time has always been a desired goal, but hitherto not achieved. Several protein researchers have shown interest in using DLS to monitor crystal growth process in a droplet, but elaborate instrumentation and optical alignment problems have made in-situ applications difficult. We demonstrate that such an experiment is now possible. Our system offers fast (5 seconds) determination of particle size, utilize safe levels of very low laser power (less than or equal to 0.2 mW), a small scattering volume (approximately 2 x 10(exp -5) cu mm) and high spatial coherence (Beta) values. This is a major step forward when compared to currently available DLS systems.

Ansari, Rafat R.↗

Improved Venus ionopause altitude calculation and comparison with measurement

Improved approximations are incorporated into the inviscid fluid method originated by Spreiter et al (1970) in calculations of the altitude of the Venus ionopause. The altitude calculations are then compared with median altitudes measured by the Pioneer Venus retarding potential analyzer. The calculated ionopause shape is found to closely approximate the measured meridian shape in the solar zenith angle (SZA) range of zero-135 deg. The use of improved ionospheric pressure field ionosheath pressure and Prandtl-Meyer expansion approximations lowers the terminator ionopause altitude to approximately half that obtained with the usual Spreiter approximations. It is also determined that the calculated dawn ionopause is about 300 km higher than the dusk ionopause, and that both ionopauses are close to their respective measured meridian values. It is concluded that median ionopause altitude within the SZA angle range may be calculated without inclusion of a viscous interaction in the theory.

Knudsen, W. C.↗

An optical study of grain formation: Casting and solidification technology (2-IML-1)

By studying the unidirectional growth of a metal-model material in microgravity, an attempt is made to characterize alloy solidification. Using holograms and supporting temperature measurements obtained during processing in the Fluids Experiment System (FES), the solute and thermal fields associated with the dendrite growth front and extraneous nucleation will be measured and compared to a theoretical (computational) model. Ground based supporting experiments include particle tracking to measure the velocity fields, and optical phase shift techniques (confocal optical signal processing, interferometry, and Schlieren) to study thermal and solutal fields.

Mccay, Mary H.↗

Modeling of Slosh Dynamics in Cryogenic Propellant Tanks in Microgravity Environments

The slosh dynamics in cryogenic fuel tanks under microgravity is a pressing problem that severely affects the reliability of launching spacecraft. After reaching low Earth orbit, the propellant in a multistage rocket experiences large and cyclic changes in temperature as a result of solar heating. Tank wall heating can induce thermal stratification and propellant boiloff, particularly during slosh-inducing vehicle maneuvers. Precise understanding of the dynamic and thermodynamic effects of propellant slosh caused by these maneuvers is critical to mission performance and success. Computational fluid dynamics (CFD) analysis is used extensively within the space vehicle industry in an attempt to characterize the behavior of liquids in microgravity, yet experimental data to quantify these predictions is very limited and reduces confidence in the analytical predictions. A novel approach designed to produce high-fidelity data for correlation to CFD model predictions is being developed with the assistance of Florida Institute of Technology (FIT) and Sierra Lobo, Inc. With few exceptions, previous work in slosh dynamics was theoretical or treated the mass of fuel as a variable of inertia only; such models did not consider the viscosity, surface tension, or other important fluid effects. The challenges in this research are in the development of instrumentation able to measure the required parameters, the computational ability to quantify the fluid behaviors, and the means to assess both the measurements and predictions. The design of this experiment bridges the understanding of slosh dynamics in microgravity by a comprehensive approach that combines CFD tools, dynamic simulation tools, semianalytical models of the predominant fluid effects, and an experimental framework that includes measurement and characterization of liquid slosh in one-degree-of-freedom (DOF) and two-DOF experiments, and ultimately experiments in a NASA low-gravity aircraft.

Source record↗

Feasibility of Electrostriction for Measurement of the Critical Temperature in the Critical Viscosity Experiment

The large compressibility of a pure fluid near its critical point is a potential means of measuring the critical temperature. At the suggestion of Prof. Ferrell we observed electrostriction in xenon by applying a large voltage across a small, open capacitor immersed in the sample and then measuring the capacitance change caused by the subsequent increase in the xenon's local density. This scheme was attractive because the compressibility is a large, well-understood effect and because we were already familiar with low-voltage capacitance measurements. We found qualitative agreement with our initial expectations based on the fluid's compressibility. However, we also found an additional effect comparable in size to the expected electrostriction but proportional to the applied voltage. We have no explanation for this effect. Thus, given the Science Panel's recommendation against investing extensive effort in this direction, we are abandoning further development of an alternate means for measuring the critical temperature.

Berg, Robert F.↗

Results from the Radio Frequency Mass Gauge Technology Demonstration on the Intuitive Machines Nova-C Lunar Lander

A cryogenic propellant mass gauge known as the Radio Frequency Mass Gauge (RFMG) was integrated into the Intuitive Machines (IM) Nova-C lunar lander and provided an estimate of the liquid oxygen and liquid methane mass in the lander propellant tanks throughout the IM-1 mission, including during microgravity coast phases. An RFMG electronics controller was used to measure and record the spectrum of the RF signal reflected from an antenna sensor in each tank over the frequency range 100 to 1,300 MHz. The RF spectrum of each of the tanks is unique and is sensitive to the index of refraction of the propellants and the spatial distribution of the liquid within the tanks. Electromagnetic simulation software was used to simulate the antenna response spectra for a given tank geometry, fluid properties, and liquid–vapor configurations within the tank. Over 10,000 antenna response simulations were completed for each propellant tank prior to the IM-1 mission and represented various volumetric fill levels and fluid configurations. The simulated spectra served as a database against which measured tank spectra were compared. For analysis, a spectral matching algorithm was used to find the best match between measured and simulated spectra, and the gauged mass was calculated from the most highly correlated fluid mass simulations. RFMG measurements were recorded during tank loading on the launch pad and during translunar coast, lunar orbit insertion, low lunar orbit, powered descent to the lunar surface, and postlanding on the Moon. This paper describes the RF and fluid simulations, the RFMG measurements and analysis of spectral data, the RFMG instrument, and the gauged results throughout all phases of the IM-1 mission.

lunar lander↗

Results from the Radio Frequency Mass Gauge Technology Demonstration on the Intuitive Machines Nova-C Lunar Lander

A cryogenic propellant mass gauge known as the Radio Frequency Mass Gauge (RFMG) was integrated into the Intuitive Machines (IM) Nova-C lunar lander and provided an estimate of the liquid oxygen and liquid methane mass in the lander propellant tanks throughout the IM-1 mission, including during microgravity coast phases. An RFMG electronics controller was used to measure and record the spectrum of the RF signal reflected from an antenna sensor in each tank over the frequency range 100 to 1,300 MHz. The RF spectrum of each of the tanks is unique and is sensitive to the index of refraction of the propellants and the spatial distribution of the liquid within the tanks. Electromagnetic simulation software was used to simulate the antenna response spectra for a given tank geometry, fluid properties, and liquid–vapor configurations within the tank. Over 10,000 antenna response simulations were completed for each propellant tank prior to the IM-1 mission and represented various volumetric fill levels and fluid configurations. The simulated spectra served as a database against which measured tank spectra were compared. For analysis, a spectral matching algorithm was used to find the best match between measured and simulated spectra, and the gauged mass was calculated from the most highly correlated fluid mass simulations. RFMG measurements were recorded during tank loading on the launch pad and during translunar coast, lunar orbit insertion, low lunar orbit, powered descent to the lunar surface, and postlanding on the Moon. This paper describes the RF and fluid simulations, the RFMG measurements and analysis of spectral data, the RFMG instrument, and the gauged results throughout all phases of the IM-1 mission.

lunar lander↗

Turbidity of a Binary Fluid Mixture: Determining Eta

A ground based (1-g) experiment is in progress that will measure the turbidity of a density-matched, binary fluid mixture extremely close to its liquid-liquid critical point. By covering the range of reduced temperatures t equivalent to (T-T(sub c)) / T(sub c) from 10(exp -8) to 10(exp -2), the turbidity measurements will allow the critical exponent eta to be determined. No experiment has precisely determined a value of the critical exponent eta, yet its value is significant to theorists in critical phenomena. Relatively simple critical phenomena, as in the liquid-liquid system studied here, serve as model systems for more complex systems near a critical point.

Jacobs, Donald T.↗

Saturn's Magnetosphere and Properties of Upstream Flow at Titan: Preliminary Results

Using Cassini Plasma Spectrometer (CAPS) Ion Mass Spectrometer (IMS) measurements, we present the ion fluid properties and its ion composition of the upstream flow for Titan's interaction with Saturn's magnetosphere. A 3D ion moments algorithm is used which is essentially model independent with only requirement is that ion flow is within the CAPS IMS 2(pi) steradian field-of-view (FOV) and that the ion 'velocity distribution function (VDF) be gyrotropic. These results cover the period from TA flyby (2004 day 300) to T22 flyby (2006 363). Cassini's in situ measurements of Saturn's magnetic field show it is stretched out into a magnetodisc configuration for Saturn Local Times (SLT) centered about midnight local time. Under those circumstances the field is confined near the equatorial plane with Titan either above or below the magnetosphere current sheet. Similar to Jupiter's outer magnetosphere where a magnetodisc configuration applies, one expects the heavy ions within Saturn's outer magnetosphere to be confined within a few degrees of the current sheet while at higher magnetic latitudes protons should dominate. We show that when Cassini is between dusk-midnight-dawn local time and spacecraft is not within the current sheet that light ions (H, 142) tend to dominate the ion composition for the upstream flow. If true, one may expect the interaction between Saturn's magnetosphere, locally devoid of heavy ions and Titan's upper atmosphere and exosphere to be significantly different from that for Voyager 1, TA and TB when heavy ions were present in the upstream flow. We also present observational evidence for Saturn's magnetosphere interaction with Titan's extended H and H2 corona which can extend approx. 1 Rs from Titan.

Sittler, E. C., Jr.↗

A dynamic pressure calibration standard

A dynamic pressure calibration standard has been developed for calibrating flush diaphragm mounted pressure transducers. Pressures up to 20 kPa (3 psi) have been accurately generated over a frequency range of 50 to 1800 hz. The uncertainty of the standard is +/-5 pct to 5kPa (.75 psi) and +/-10 pct from 5 kPa (.75 psi) to 20 kPa (3 psi). The system consists of two conically shaped, aluminum columns, one 5 cm (2 in.) high for low pressures and another 11 cm (4.3 in.) high for higher pressures, each filled with a viscous fluid. A column is mounted on the armature of a vibration exciter which imparts a sinusoidally varying acceleration to the fluid column. Two pressure transducers mounted at the base of the column sense the sinusoidally varying pressure. This pressure is determined from measurements of the density of the fluid, the height of the fluid, and the acceleration of the column. A section of the taller column is filled with steel balls to control the damping of the fluid to extend its useful frequency range.

Schutte, P. C.↗

Probe for Sampling of Interstitial Fluid From Bone

An apparatus characterized as both a membrane probe and a bone ultrafiltration probe has been developed to enable in vivo sampling of interstitial fluid in bone. The probe makes it possible to measure the concentration of calcium and other constituents of the fluid that may be relevant to bone physiology. The probe could be especially helpful in experimental studies of microgravitational bone loss and of terrestrial bone-loss disease states, including osteoporosis. The probe can be implanted in the bone tissue of a living animal and can be used to extract samples of the interstitial bone fluid from time to time during a long-term study. The probe includes three 12-cm-long polyacrylonitrile fibers configured in a loop form and attached to polyurethane tubing [inside diameter 0.025 in. (0.64 mm), outside diameter 0.040 in. (1 mm)]; the attachment is made by use of a 1-cm-long connecting piece of polyurethane tubing [inside diameter 0.035 0.003 in. (0.89 0.08 mm), outside diameter 0.060 0.003 in. (1.52 0.08 mm)]. At the distal end, a 2-cm-long piece of polyurethane tubing of the same inner and outer diameters serves as a connector to a hub. A 1-cm long piece of expanded poly (tetrafluoroethylene) tubing over the joint between the fibers and the connecting tubing serves as a tissue-in-growth site.

Janle, Elsa M.↗

Velocity Measurement in a Dual-Mode Supersonic Combustor using Particle Image Velocimetry

Temporally and spatially-resolved, two-component measurements of velocity in a supersonic hydrogen-air combustor are reported. The combustor had a single unswept ramp fuel injector and operated with an inlet Mach number of 2 and a flow total temperature approaching 1200 K. The experiment simulated the mixing and combustion processes of a dual-mode scramjet operating at a flight Mach number near 5. The velocity measurements were obtained by seeding the fuel with alumina particles and performing Particle Image Velocimetry on the mixing and combustion wake of the ramp injector. To assess the effects of combustion on the fuel air-mixing process, the distribution of time-averaged velocity and relative turbulence intensity was determined for the cases of fuel-air mixing and fuel-air reacting. Relative to the mixing case, the near field core velocity of the reacting fuel jet had a slower streamwise decay. In the far field, downstream of 4 to 6 ramp heights from the ramp base, the heat release of combustion resulted in decreased flow velocity and increased turbulence levels. The reacting measurements were also compared with a computational fluid dynamics solution of the flow field. Numerically predicted velocity magnitudes were higher than that measured and the jet penetration was lower.

Goyne, C. P.↗

Injectant mole fraction measurements of transverse injection in constant area supersonic ducts

Planar measurements of the injectant mole fraction distribution in a nonreacting model SCRAMJET combustor have been made using a nonintrusive optical technique, laser-induced iodine fluorescence. The combustor geometry investigated in this work was staged, transverse sonic injection of air into Mach 2 and Mach 2.9 freestreams. Accurate three-dimensional surveys of the injectant mole fraction distribution for both freestream Mach numbers have been generated. These experimental measurements provide valuable insight into the fluid mechanics of the mixing process. The existence of streamwise vortices is shown to dominate the mixing in the injector nearfield while shock wave interactions with the injectant plume are seen to significantly enhance mixing downstream of the injectors. The effect of combustor Mach number on injectant mixing is found to be small for this geometry. These measurements provide an accurate data set for the validation of computational fluid dynamics codes being developed for the calculation of highly three-dimensional nonreacting supersonic combustor flow fields.

Hollo, Steven D.↗

The Spatial Distribution of Soluble Organic Matter and Their Relationship to Minerals in the Asteroid (162173) Ryugu

We performed in-situ analysis on a ~1 mm-sized grain A0080 returned by the Hayabusa2 spacecraft from near-Earth asteroid (162173) Ryugu to investigate the relationship of soluble organic matter (SOM) to minerals. Desorption electrospray ionization-high resolution mass spectrometry (DESI-HRMS) imaging mapped more than 200 CHN, CHO, CHO–Na (sodium adducted), and CHNO soluble organic compounds. A heterogeneous spatial distribution was observed for different compound classes of SOM as well as among alkylated homologues on the sample surface. The A0080 sample showed mineralogy more like an Ivuna-type (CI) carbonaceous chondrite than other meteorites. It contained two different lithologies, which are either rich (lithology 1) or poor (lithology 2) in magnetite, pyrrhotite, and dolomite. CHN compounds were more concentrated in lithology 1 than in lithology 2; on the other hand, CHO, CHO–Na, and CHNO compounds were distributed in both lithologies. Such different spatial distribution of SOM is likely the result of interaction of the SOM with minerals, during precipitation of the SOM via fluid activity, or could be due to difference in transportation efficiencies of SOMs in aqueous fluid. Organic-related ions measured by time-of-flight secondary ion mass spectrometry (ToF–SIMS) did not coincide with the spatial distribution revealed by DESI-HRMS imaging. This result may be because the different ionization mechanism between DESI and SIMS, or indicate that the ToF–SIMS data would be mainly derived from methanol-insoluble organic matter in A0080. In the Orgueil meteorite, such relationship between altered minerals and SOM distributions was not observed by DESI-HRMS analysis and field-emission scanning electron microscopy, which would result from differences of SOM formation processes and sequent alteration process on the parent bodies or even on the Earth. Alkylated homologues of CHN compounds were identified in A0080 by DESI-HRMS imaging as observed in the Murchison meteorite, but not from the Orgueil meteorite. These compounds with a large C number were enriched in Murchison fragments with abundant carbonate grains. In contrast, such relationship was not observed in A0080, implying different formation or growth mechanisms for the alkylated CHN compounds by interaction with fluid and minerals on the Murchison parent body and asteroid Ryugu.

Ryugu↗

Aerothermodynamic Facilities And Measurement: Flow Characterization in Shock Tunnels

This presentation will examine the key performance aspects of shock tunnels as they relate to their use as aerothermodynamic flow simulation facilities. Assessment of shock tube reservoir conditions and flow contaminants generated in the shock tube will be presented along with their limiting impact on viable test envelopes, Facility nozzle performance as it pertains to test time assessment and nozzle exit flow quality (survey of pressure, temperature, and species) will be addressed. Also included will be a discussion of free stream flow diagnostics, both intrusive and nonintrusive, for measurement of critical flow properties not directly inferred from surface mounted transducers. The use of computational fluid dynamics for purposes of validating experimental measurements as well as predicting performance in regimes where measurements are not feasible or possible will be discussed. The use of CFD for facility research and design will also be presented.

Cavolowsky, John A.↗

Universal Two-Phase Convection Heat Transfer Correlations for Cryogenic Pipe Chilldown

This paper presents a set of universal two-phase convection heat transfer correlations for modeling boiling heat transfer during pipe chilldown fit over the widest available range of cryogenic fluids and thermodynamic conditions. The correlations improve upon prior correlations that were developed separately for liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching datasets. The new correlations include equations to calculate the single-phase vapor heat transfer, film boiling heat transfer, transition boiling heat transfer, nucleate boiling heat transfer, single-phase liquid heat transfer, bulk vapor temperature during high quality film boiling, Leidenfrost temperature, critical heat flux, critical heat flux temperature, and the onset of nucleate boiling temperature. The correlations were validated against LH2, LN2, liquid methane, liquid oxygen, and liquid argon pipe quenching datasets. The eight datasets cover the following parameter ranges: pipe lengths of 0.1 to 6.5m; outer pipe diameters of 12.7 to 25.4 mm; pipe wall thicknesses from 0.51 to 1.64 mm; flow directions of upward, downward, and horizontal; gravity levels of 1g and 0g±0.01g. A numerical model assumes homogeneous mixing between the vapor and liquid and implicitly integrates the coupled energy equations for the pipe and fluid, as well as continuity for the fluid. The model was used to estimate the equilibrium quality and fluid mass accumulation along the pipes during chilldown from estimates of the fluid-pipe heat transfer extracted from temperature measurements. The correlations can be implemented in lumped parameter codes such as SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP) to improve the accuracy of chilldown time and chilldown boiloff mass predictions. Such predictions are useful for designing ground or in-space cryogenic liquid transfer systems.

Universal Correlations↗

Development of on-orbit fluid gaging techniques

The objective was to measure liquid mass to plus or minus 1 percent in two-phase tanks in orbit. Viewgraphs present information on concept selection, program status and anticipated results. The program aims at test results showing 1 percent accuracy, the development of a breadboard test article usable in the lab or aboard a KC-135, and a concept that will permit flight article design to proceed.