Accuracy of Real-time Couch Tracking During 3-dimensional Conformal Radiation Therapy, Intensity Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Prostate Cancer

Purpose: To evaluate the accuracy of real-time couch tracking for prostate cancer. Methods and Materials: Intrafractional motion trajectories of 15 prostate cancer patients were the basis for this phantom study; prostate motion had been monitored with the Calypso System. An industrial robot moved a phantom along these trajectories, motion was detected via an infrared camera system, and the robotic HexaPOD couch was used for real-time counter-steering. Residual phantom motion during real-time tracking was measured with the infrared camera system. Film dosimetry was performed during delivery of 3-dimensional conformal radiation therapy (3D-CRT), step-and-shoot intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). Results: Motion of the prostate was largest in the anterior-posterior direction, with systematic ( N-Ary-Summation ) and random ({sigma}) errors of 2.3 mm and 2.9 mm, respectively; the prostate was outside a threshold of 5 mm (3D vector) for 25.0%{+-}19.8% of treatment time. Real-time tracking reduced prostate motion to N-Ary-Summation =0.01 mm and {sigma} = 0.55 mm in the anterior-posterior direction; the prostate remained within a 1-mm and 5-mm threshold for 93.9%{+-}4.6% and 99.7%{+-}0.4% of the time, respectively. Without real-time tracking, pass rates based on a {gamma} index of 2%/2 mm in film dosimetry ranged between 66% and 72% for 3D-CRT, IMRT, and VMAT, on average. Real-time tracking increased pass rates to minimum 98% on average for 3D-CRT, IMRT, and VMAT. Conclusions: Real-time couch tracking resulted in submillimeter accuracy for prostate cancer, which transferred into high dosimetric accuracy independently of whether 3D-CRT, IMRT, or VMAT was used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

M dwarfs, microlensing, and the mass budget of the Galaxy

We show that faint red stars do not contribute significantly to the mass budget of the Galaxy or to microlensing statistics. Our results are obtained by analyzing two long exposures of a high-latitude field taken with the Wide Field Camera (WFC) on the newly repaired Hubble Space Telescope (HST). Stars are easily distinguished from galaxies essentially to the limiting magnitudes of the images. We find five stars with 2.0 less than V - I less than 3.0 and I less than 25.3 and no stars with V - I greater than 3.0. Therefore, main-sequence stars with M(sub I) greater than 10 that are above the hydrogen-burning limit in the dark halo or the spheroid contribute less than 6% of the unseen matter. Faint red disk stars, M-dwarfs, contribute at most 15% to the mass of the disk. We parameterize the faint end of the cumulative distribution of stars, Phi, as a function of luminosity L(sub V), d Phi/d ln L(sub V) proportional to L(sub V exp -gamma). For spheroid stars, gamma less than 0.32 over the range 6 less than M(sub V) less than 17, with 98% confidence. The disk luminosity function falls, gamma less than 0, for 15 approximately less than M(sub V) approximately less than 19. Faint red stars in the disk or thick disk, and stars with M(sub V) less than 16 in the spheroid contribute tau less than 10(exp -8) to the optical depth to microlensing toward the Large Magellanic Cloud.

Bahcall, John N.↗

Novel imaging technique for thermal neutrons using a fast optical camera

A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Testing for High-Resolution Radiation-Hardened Camera System (Final CRADA Report)

The nuclear energy industry needs higher-image quality and higher rad-hard vision systems for refueling and inspection operations that are required every 12-18 months for all operating commercial reactors. During refueling operations, the serial numbers of fuel assemblies need to be visually verified in a challenging high radiation environment with dose rates on the order of 1kGy/hr. at the top of the core (approximately 10 days after shutdown). Vega Wave Systems has developed and built a radiation hard vision system that: 1. has high radiation hardness, 2. demonstrated best in the industry image quality, 3. has small size and weight, and 4. does not suffer from radiation-induced noise. ANL-1060 (02/13/2023) The proprietary Enduray vision system from Vega Wave Systems, Inc. is designed to withstand more than 400x the radiation level of the Vidicon-based systems, currently the highest radiation tolerant system in use today. The Van De Graaff (VDG) electron accelerator at Argonne National Laboratory is ideally suited for testing of Enduray vision system. VDG provides a broad band (up to 3 MeV) x-ray source that reasonably approximates the energy and spectrum of the gamma radiation expected at the top of a nuclear core 10 days after shutdown (~1kGy/hr.), is easily controlled for variable tests, and will not activate the parts under radiation for ease of timely and close inspection and characterization of the system in case of operational issues.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Artifacts in digital coincidence timing

Digital methods are becoming increasingly popular for measuring time differences, and are the de facto standard in PET cameras. These methods usually include a master system clock and a (digital) arrival time estimate for each detector that is obtained by comparing the detector output signal to some reference portion of this clock (such as the rising edge). Time differences between detector signals are then obtained by subtracting the digitized estimates from a detector pair. A number of different methods can be used to generate the digitized arrival time of the detector output, such as sending a discriminator output into a time to digital converter (TDC) or digitizing the waveform and applying a more sophisticated algorithm to extract a timing estimator.All measurement methods are subject to error, and one generally wants to minimize these errors and so optimize the timing resolution. A common method for optimizing timing methods is to measure the coincidence timing resolution between two timing signals whose time difference should be constant (such as detecting gammas from positron annihilation) and selecting the method that minimizes the width of the distribution (i.e. the timing resolution). Unfortunately, a common form of error (a nonlinear transfer function) leads to artifacts that artificially narrow this resolution, which can lead to erroneous selection of the 'optimal' method. In conclusion, the purpose of this note is to demonstrate the origin of this artifact and suggest that caution should be used when optimizing time digitization systems solely on timing resolution minimization.

97 MATHEMATICS AND COMPUTING↗

Training courses on neutron detection systems on the ISIS research reactor: on-site and through internet training

Today, ISIS research reactor is an essential tool for Education and Training programs organized by the National Institute for Nuclear Science and Technology (INSTN) from CEA. In the field of nuclear instrumentation, the INSTN offers both, theoretical courses and training courses on the use of neutron detection systems taking advantage of the ISIS research reactor for the supply of a wide range of neutron fluxes. This paper describes the content of the training carried out on the use of neutron detectors and detection systems, on-site or remote. The ISIS reactor is a 700 kW open core pool type reactor. The facility is very flexible since neutron detectors can be inserted into the core or its vicinity, and be used at different levels of power according to the needs of the course. Neutron fluxes, typically ranging from 1 to 10{sup 12} n/cm{sup 2}.s, can be obtained for the characterisation of the neutron detectors and detection systems. For the monitoring of the neutron density at low level of power, the Instrumentation and Control (I and C) system of the reactor is equipped with two detection systems, named BN1 and BN2. Each way contains a fission chamber, type CFUL01, connected to an electronic system type SIREX.The system works in pulse mode and exhibits two outputs: the counting rate and the doubling time. For the high level of power, the I and C is equipped with two detection systems HN1 and HN2.Each way contain a boron ionization chamber (type CC52) connected to an electronics system type SIREX. The system works in current mode and has two outputs: the current and the doubling time. For each mode, the trainees can observe and measure the signal at the different stages of the electronic system, with an oscilloscope. They can understand the role of each component of the detection system: detector, cable and each electronic block. The limitation of the detection modes and their operating range can be established from the measured signal. The trainees can also modify the settings of the electronic system, such as the high voltage and the discrimination level in order to obtain all the characteristic curves of the detectors. These curves are used to define the right setting of the electronic system and to discuss the expected degradation of the detector signal resulting from the detector damage under the integrated neutron and gamma fluxes. Moreover, in addition to the study of the neutron detection systems itself, the integration of the measurements made by these detection systems in the logic of the safety system of the nuclear reactor is also addressed. Providing the trainees with an extensive overview of each part of the neutron monitoring instrumentation apply to a nuclear reactor, hands-on measurements on the ISIS reactor play a major role in ensuring a practical and comprehensive understanding of the neutron detection system and their integration in the safety system of nuclear reactors. It also gives a solid background for the follow up and the development of the neutron detection systems. In addition to on-reactor training, Internet Reactor Laboratory capability has been implemented on the ISIS reactor in 2014. For the Internet Reactor Laboratory an extensive video conference system has been implemented on ISIS reactor. The system includes 4 cameras and the transmission of the video signal given by the supervision system of the reactor which records and processes the data of the reactor. According to the pedagogic needs during the training courses, the lecturer on the ISIS reactor chooses to broadcast the relevant information at each stage of the course. For example, graph showing the histogram of the counting and current as a function of the time, or the electrical signal observed on the oscilloscope, can be broadcasted trough internet. By interacting through the video conference, the remote classroom is able to ask for changes in the reactor power or settings of the detection systems. They can also ask for the broadcast of some particular information. At the guest institution, the information is displayed in two parts or screens, as shown in the Figure 3. Concerning the interaction with - and the feedback from - the remote classroom, the camera of the video system in the remote classroom is used to ensure the contact between the trainees and the lecturer and reactor operators. Thus, the Internet Reactor Laboratory is complementary to the on reactor training courses. It allows distant learning, reducing the overall cost of the course when this is necessary. It can efficiently be used for the development of the human resources needed by the nuclear industry and the nuclear programs in countries without research reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A NEW CEPHEID DISTANCE TO THE GIANT SPIRAL M101 BASED ON IMAGE SUBTRACTION OF HUBBLE SPACE TELESCOPE/ADVANCED CAMERA FOR SURVEYS OBSERVATIONS

We accurately determine a new Cepheid distance to M101 (NGC 5457) using archival Hubble Space Telescope (HST)/Advanced Camera for Surveys V and I time series photometry of two fields within the galaxy. We make a slight modification to the ISIS image subtraction package to obtain optimal differential light curves from HST data. We discovered 827 Cepheids with periods between 3 and 80 days, the largest extragalactic sample of Cepheids observed with HST by a factor of two. With this large Cepheid sample, we find that the relative distance of M101 from the Large Magellanic Cloud is {Delta}{mu}{sub LMC} = 10.63 {+-} 0.04 (random) {+-} 0.06 (systematic) mag. If we use the geometrically determined maser distance to NGC 4258 as our distance anchor, the distance modulus of M101 is {mu}{sub 0} = 29.04 {+-} 0.05 (random) {+-} 0.18 (systematic) mag or D = 6.4 {+-} 0.2 (random) {+-} 0.5 (systematic) Mpc. The uncertainty is dominated by the maser distance estimate ({+-}0.15 mag), which should improve over the next few years. We determine a steep metallicity dependence, {gamma}, for our Cepheid sample through two methods, yielding {gamma} = -0.80 {+-} 0.21 (random) {+-} 0.06 (systematic) mag dex{sup -1} and {gamma} = -0.72{sup +0.22}{sub -0.25} (random) {+-} 0.06 (systematic) mag dex{sup -1}. We see marginal evidence for variations in the Wesenheit period-luminosity relation slope as a function of deprojected galactocentric radius. We also use the tip of the red giant branch method to independently determine the distance modulus to M101 of {mu}{sub 0} = 29.05 {+-} 0.06 (random) {+-} 0.12 (systematic) mag.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MAXI Nova Alert System and the Latest Scientific Results

MAXI, Monitor of All-sky X-ray Image, is the first astronomical telescope onboard the ISS. One of the main goals of our mission is to discover new transient objects by scanning more than 95% of the sky every {approx}92 min with two types of X-ray cameras, Gas Slit Camera (GSC) and Solid-state Slit Camera (SSC). We have developed a completely new data analysis system, a nova alert system, to find transient objects and send alerts to the world as soon as possible. Here we describe the current status of the system, and transient objects discovered with the system.

79 ASTRONOMY AND ASTROPHYSICS↗

Removing cosmic-ray hits from multiorbit HST Wide Field Camera images

We present an optimized algorithm that removes cosmic rays ('CRs') from multiorbit Hubble Space Telescope (HST) Wide Field/Planetary Camera ('WF/PC') images. It computes the image noise in every iteration from the WF/PC CCD equation. This includes all known sources of random and systematic calibration errors. We test this algorithm on WF/PC stacks of 2-12 orbits as a function of the number of available orbits and the formal Poissonian sigma-clipping level. We find that the algorithm needs greater than or equal 4 WF/PC exposures to locate the minimal sky signal (which is noticeably affected by CRs), with an optimal clipping level at 2-2.5 x sigma(sub Poisson). We analyze the CR flux detected on multiorbit 'CR stacks,' which are constructed by subtracting the best CR filtered images from the unfiltered 8-12 orbit average. We use an automated object finder to determine the surface density of CRS as a function of the apparent magnitude (or ADU flux) they would have generated in the images had they not been removed. The power law slope of the CR 'counts' (gamma approximately = 0.6 for N(m) m(exp gamma)) is steeper than that of the faint galaxy counts down to V approximately = 28 mag. The CR counts show a drop off between 28 less than or approximately V less than or approximately 30 mag (the latter is our formal 2 sigma point source sensitivity without spherical aberration). This prevents the CR sky integral from diverging, and is likely due to a real cutoff in the CR energy distribution below approximately 11 ADU per orbit. The integral CR surface density is less than or approximately 10(exp 8)/sq. deg, and their sky signal is V approximately = 25.5-27.0 mag/sq. arcsec, or 3%-13% of our NEP sky background (V = 23.3 mag/sq. arcsec), and well above the EBL integral of the deepest galaxy counts (B(sub J) approximately = 28.0 mag/sq. arcsec). We conclude that faint CRs will always contribute to the sky signal in the deepest WF/PC images. Since WFPC2 has approximately 2.7x lower read noise and a thicker CCD, this will result in more CR detections than in WF/PC, potentially affecting approximately 10%-20% of the pixels in multiorbit WFPC2 data cubes.

Windhorst, Rogier A.↗

Role of stochasticity in turbulence and convective intermittent transport at the scrape off layer of Ohmic plasma in QUEST

Statistical features of fluctuations are investigated using the fast camera imaging technique in the scrape of layer (SOL) of electron cyclotron resonance heated Ohmic plasma. Fluctuations in the SOL towards low field side are dominated by coherent convective structures (blobs). Two dimensional structures of the higher order moments (skewness s and kurtosis k) representing the shape of probability density function (PDF) are studied. s and k are seen to be functions of the magnetic field lines. s and k are consistently higher towards the bottom half of the vessel in the SOL showing the blob trajectory along the field lines from the top towards bottom of the vessel. Parabolic relation (k=As{sup 2}+C) is observed between s and k near the plasma boundary, featuring steep density gradient region and at the far SOL. The coefficient A, obtained experimentally, indicates a shift of prominence from pure drift-wave instabilities towards fully developed turbulence. Numerical coefficients characterizing the Pearson system are derived which demonstrates the progressive deviation of the PDF from Gaussian towards gamma from the density gradient region, towards the far SOL. Based on a simple stochastic differential equation, a direct correspondence between the multiplicative noise amplitude, increased intermittency, and hence change in PDF is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo investigation of a high-efficiency, two-plane Compton camera for long-range localization of radioactive materials

Compton cameras have become an instrument of interest for long-range localization of radioactive materials in nuclear-nonproliferation applications. In this work, a specialized simulation tool was developed for the optimization of a Compton camera through realistic Monte Carlo simulations. This tool can be used for Compton cameras with different geometries. The MCNPX-PoliMi code was used to simulate Compton scatters and photoelectric absorptions in the camera's detectors. The imaging capability is derived from the physics of Compton scattering and the full-energy information obtained in photoelectric absorptions. The simulated system is a 1 1 m2 Compton camera consisting of two planar arrays of photon detectors. Several scintillators were evaluated: LaBr3, CaF2, and NaI(Tl) (all inorganic scintillators), and C9H10 (plastic organic scintillator). The investigation was carried out with a 137Cs source. A minimum detectable activity (MDA) was defined and used to assess the performance of cameras based on different detectors. The simulation results show that C9H10 is a reliable, low-cost, scatter-plane material, increasing the MDA by ~0.2 mCi when compared to a CaF2 scatter plane. On the other hand, the intrinsic background of LaBr3 undermines its above-average energy resolution as the MDA increased by ~0.5 mCi when compared to a NaI(Tl) absorption plane.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THE TeV BINARY HESS J0632+057 IN THE LOW AND HIGH X-RAY STATE

We report on a 40 ks Chandra observation of the TeV emitting high-mass X-ray binary HESS J0632+057 performed in 2011 February during a high state of X-ray and TeV activity. We have used the ACIS-S camera in continuous clocking mode to search for a possible X-ray pulsar in this system. Furthermore, we compare the emission of the source during this high state, with its X-ray properties during a low state of emission, caught by a 47 ks XMM-Newton observation on 2007 September. We did not find any periodic or quasi-periodic signal in any of the two observations. We derived an average pulsed fraction 3{sigma} upper limit for the presence of a periodic signal of {approx}<35% and 25% during the low and high emission states, respectively (although this limit is strongly dependent on the frequency and the energy band). Using the best X-ray spectra derived to date for HESS J0632+057, we found evidence for a significant spectral change between the low and high X-ray emission states, with the absorption value and the photon index varying between N{sub H} {approx_equal} (2.1-4.3) x 10{sup 21} cm{sup -2} and {Gamma} {approx_equal} 1.18-1.61. In contrast to what has been observed in other TeV binaries, it seems that in this source the higher the flux, the softer the X-ray spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-600: Patient Specific IMRT Verification Using a Phosphor-Screen Based Geometric QA System: A Preliminary Study

Purpose: Raven QA (JPLC, MD) is a unified and comprehensive quality assurance system for QA of TG-142, which use a phosphor screen, a mirror system and a camera. It is to test if this device can be used for IMRT QA dosimetry. Methods: A lung IMRT case is used deliver dose to Raven QA. Accuracy of dose distribution of 5cm slab phantom using Eclipse planning system (Varian) has been confirmed both from a Monte Carlo Simulation and from a MapCheck (SunNuclear) measurement. Geometric distortion and variation of spatial dose response are corrected after background subtraction. A pin-hole grid plate is designed and used to determine the light scatter in the Raven QA box and the spatial dose response. Optic scatter model was not applied in this preliminary study. Dose is normalized to the response of the 10×10 field and the TMR of 5cm depth was considered. Results: Time to setup the device for IMRT QA takes less than 5 minutes as other commercially available devices. It shows excellent dose linearity and dose rate independent, less than 1 %. Background signal, however, changes for different field sizes. It is believed to be due to inaccurate correction of optic scatter. Absolute gamma (5%, 5mm) passing rate was higher than 95%. Conclusion: This study proves that the Raven QA can be used for a patient specific IMRT verification. Part of this study is supported by the Maryland Industrial Partnership Grant.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dark matter limits froma 15 kg windowless bubble chamber

The COUPP collaboration has successfully used bubble chambers, a technology previously applied only to high-energy physics experiments, as direct dark matter detectors. It has produced the world's most stringent spin-dependent WIMP limits, and increasingly competitive spin-independent limits. These limits were achieved by capitalizing on an intrinsic rejection of the gamma background that all other direct detection experiments must address through high-density shielding and empirically-determined data cuts. The history of COUPP, including its earliest prototypes and latest results, is briefly discussed in this thesis. The feasibility of a new, windowless bubble chamber concept simpler and more inexpensive in design is discussed here as well. The dark matter limits achieved with a 15 kg windowless chamber, larger than any previous COUPP chamber (2 kg, 4 kg), are presented. Evidence of the greater radiopurity of synthetic quartz compared to natural is presented using the data from this 15 kg device, the first chamber to be made from synthetic quartz. The effective reconstruction of the three-dimensional positions of bubbles in a highly distorted optical field, with ninety-degree bottom lighting similar to cloud chamber lighting, is demonstrated. Another innovation described in this thesis is the use of the sound produced by bubbles recorded by an array of piezoelectric sensors as the primary means of bubble detection. In other COUPP chambers, cameras have been used as the primary trigger. Previous work on bubble acoustic signature differentiation using piezos is built upon in order to further demonstrate the ability to discriminate between alpha- and neutron-induced events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

2900 Square Degree Search for the Optical Counterpart of Short Gamma-Ray Burst GRB 180523B with the Zwicky Transient Facility

There is significant interest in the models for production of short gamma-ray bursts (GRBs). Until now, the number of known short GRBs with multi-wavelength afterglows has been small. While the Fermi GRB Monitor detects many GRBs relative to the Neil Gehrels Swift Observatory, the large localization regions makes the search for counterparts difficult. With the Zwicky Transient Facility (ZTF - part of Palomar Observatory) recently achieving first light, it is now fruitful to use its combination of depth (m (sub AB) approximating 20.6), field of view (approximately 47 square degrees), and survey cadence (every approximately 3 days) to perform Target of Opportunity observations. We demonstrate this capability on GRB 180523B, which was recently announced by the Fermi GRB Monitor as a short GRB. ZTF imaged 2900 square degrees of the localization region, resulting in the coverage of 61.6 percent of the enclosed probability over two nights to a depth of m (sub AB) approximating 20.5. We characterized 14 previously unidentified transients, and none were found to be consistent with a short GRB counterpart. This search with the ZTF shows it is an efficient camera for searching for coarsely localized short GRB and gravitational-wave counterparts, allowing for a sensitive search with minimal interruption to its nominal cadence.

Coughlin, Michael W.↗

Vertical Extraction Process Implemented at the 118-K-1 Burial Ground for Removal of Irradiated Reactor Debris from Silo Structures - 12431

The primary objective of a remediation project is the safe extraction and disposition of diverse waste forms and materials. Remediation of a solid waste burial ground containing reactor hardware and irradiated debris involves handling waste with the potential to expose workers to significantly elevated dose rates. Therefore, a major challenge confronted by any remediation project is developing work processes that facilitate compliant waste management practices while at the same time implementing controls to protect personnel. Traditional burial ground remediation is accomplished using standard excavators to remove materials from trenches and other excavation configurations often times with minimal knowledge of waste that will be encountered at a specific location. In the case of the 118-K-1 burial ground the isotopic activity postulated in historic documents to be contained in vertical cylindrical silos was sufficient to create the potential for a significant radiation hazard to project personnel. Additionally, certain reported waste forms posed an unacceptably high potential to contaminate the surrounding environment and/or workers. Based on process knowledge, waste management requirements, historic document review, and a lack of characterization data it was determined that traditional excavation techniques applied to remediation of vertical silos would expose workers to unacceptable risk. The challenging task for the 118-K-1 burial ground remediation project team then became defining an acceptable replacement technology or modification of an existing technology to complete the silo remediation. Early characterization data provided a good tool for evaluating the location of potential high exposure rate items in the silos. Quantitative characterization was a different case and proved difficult because of the large diameter of the silos and the potential for variable density of attenuating soils and waste forms in the silo. Consequently, the most relevant information supporting job planning and understanding of the conditions was the data obtained from the gross gamma meter that was inserted into each casing to provide a rough estimate of dose rates in the tubes. No added value was realized in attempting to quantify the source term and/or associate the isotopic activity with a particular actual waste form (e.g., sludge). Implementing the WRM system allowed monitoring of worker and boundary exposure rates from a distance, maintaining compliance with ALARA principles. This system also provided the project team early knowledge of items being removed that had high exposure rates associated with them, thus creating an efficient method of acknowledging an issue and arriving at a solution prior to having an upset condition. An electronic dosimeter with telemetry capability replaced the excavator mounted AMP-100 system approximately half way through remediation of the silos. Much higher connectivity efficiency was derived from this configuration. Increasing the data feed efficiency additionally led to less interruption of the remediation effort. Early in system testing process a process handicap on the excavator operator was acknowledged. A loss of depth perception resulted when maneuvering the excavator and bucket using the camera feed to an in-cab monitor. Considerable practice and mock-up testing allowed this handicap to be overcome. The most significant equipment failures involved the cable connection to the camera mounted between the clamshell bucket jaws and the video splitter in the excavator cab. Rotation of the clamshell bucket was identified as the cause of cable connection failures because of the cyclic twisting motion and continuous mechanical jarring of the connection. In-cab vibration was identified as the culprit in causing connection failures of the video splitter. While these failures were repaired, substantial production time was lost. Ultimately, the decision was made to purchase a second cable and higher quality video splitter eliminate the down time. An engineering improvement for future operations would be inserting cable pig tails at more stressed cable connection points to facilitate rapid change out of the cable should that be required. Overall, the system performed better than expected in a safe and efficient manner. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-J-129: Verification of Geometric and Dosimetric Accuracy of Respiratory Management Systems Using Homemade Phantom

Purpose: Different placements of Infrared Cameras (IRC) in CT and treatment rooms can cause gating window level (GWL) variations leading to differences between GWL used for planning and treatments. Although, Varian Clinac DHX-OBI sytem and CT are equipped with the same kind of IRC, Truebeam STx (TB) has a different type of IRC known as banana type. In this study; geometric and dosimetric accuracy of respiratory management system (RPM) for different machines were investigated with a special homemade phantom. Methods: Special phantom was placed on the respiratory simulator machine and a CT data set was obtained at the end of the expirium phase (EOE). Conformal and IMRT plans were generated on the EOE CT image series for both DHX-OBI and TB LINACs while a VMAT plan was generated only for TB.The acquired respiratory graphs in the CT were directly sent to DHX-OBI system, and they were converted with software before sending to TB. EBT3 films were placed inside the phantom and were irradiated using RPM system with two machines for different plans. Planar dose distributions were compared with gamma analysis (GA) method (3mm, %3) to evaluate planned-measured dose differences. In addition, radio-opac marker was placed in the center of the phantom to evaluate the geometric accuracy of treatment field with gated flouroscopy (GF). Results: There were no shifts detected between planning and treeatment GWL for both DHX-OBI and TB. Difference on the GF image between digital graticule and radio-opac marker was <1mm for TB and 1mm for DHX-OBI. Although, GA agreement was 97% for conformal and IMRT techniques in TB, it was 96% for VMAT technique. While GA agreement was 98% for conformal technique in DHX-OBI, IMRT was 95%.ConclusionThis study showed that RPM can be used accurately in spite of different IRC placements or different types of ICR used.