Search NASA⌕ Search

SEARCH · Search NASA

Results for “Genetic Algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Thermodynamic analysis and optimization of supercritical carbon dioxide Brayton cycles for use with low-grade geothermal heat sources

The transcritical carbon dioxide Rankine cycle has emerged as an alternative for power generation in low-grade heat applications. However, the low heat rejection temperatures required for condensing the carbon dioxide is almost prohibitive for many locations. A simple solution is the adoption of a supercritical carbon dioxide Brayton cycle which does not need such low temperature heat sinks. This power cycle has been poorly studied previously in low-grade heat applications. Therefore, with the aim of determining the performance and feasibility of the supercritical carbon dioxide Brayton cycle from thermodynamic viewpoint, using a low-grade geothermal heat source, this paper presents a comparative thermodynamic analysis between four different supercritical carbon dioxide Brayton cycles. For this purpose, detailed models were developed and solved by coupling the thermodynamic model with the thermal-hydraulic model of a Printed Circuit Heat Exchanger. Subsequently, simulations of a base case, a parametric analysis, and an optimization using Genetic Algorithms, were carried out. Results show that there is a combination of operating conditions that maximizes the electrical output of the system. Besides, some values of the minimum pressure of the cycles can increase substantially the precooler cooling water pumping power. At the optimum design point, using a 20 kg/s geothermal brine stream at 150 °C as heat source with a minimum allowable reinjection temperature of 70 °C, the Intercooled Recuperated Brayton Cycle achieved the highest electric power output, energy and exergy efficiencies, obtaining values of 779.99 kW, 11.51%, and 52.49%, respectively. The other feasible alternatives were the Recuperated Brayton Cycle, the Simple Brayton Cycle and the Intercooled Brayton Cycle, ranked, in that order.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel electro-hydraulic unit design based on a shaftless integration of an internal gear machine and a permanent magnet electric machine

In recent years, increasingly stringent emission regulations have spurred an electrification trend in off-highway vehicle technology. To address challenges such as the high cost of power electronics components, limited battery capacity, and the substantial modifications required for the vehicles, there is a pressing need to develop high-speed, cost-effective, compact, and efficient electro-hydraulic units capable of powering vehicle functions. In response to these demands, this paper introduces an innovative morphology for an electro-hydraulic unit and outlines the integration method for a crescent-type internal gear machine with a permanent magnet synchronous electric machine. The proposed morphology aims to minimize component count through a shaftless solution while incorporating a cooling system that utilizes the same working fluid as the hydraulic machine. The design approach utilizes a genetic algorithm optimization process to maximize overall energy efficiency and compactness. Insights gained from the optimization results shed light on the relationship between key design parameters and unit performance, enhancing the understanding of this electro-hydraulic unit. A prototype of the unit was manufactured and tested, demonstrating a volumetric efficiency ranging from 81 % to 97 % at a maximum rotational velocity of the pinion of 6000 rpm. Finally, these results validate both the morphology and the design approach, indicating the feasibility of designing compact electro-hydraulic units that leverage hydraulic machines with higher maximum rotational velocities than commercially available counterparts as a mean to enhance efficiency and compactness.

30 DIRECT ENERGY CONVERSION↗

Statorless mixed flow turbine for transonic pulsating inflow

Effective harvesting of power from high speed highly transient inflows such as the outflow of rotating detonation combustors (RDCs) is key to achieving their promised cycle efficiency step jump. To increase power density and efficiency simultaneously, a concept that can directly ingest transonic outflow, addressing the choking is needed, i.e. without additional transition elements. A new statorless design was assessed using a comprehensive approach to quantify all contributions to loss generation in transient flows, locally and globally. The turbine rotor was designed under steady flow conditions with a genetic algorithm. The comparison of power and loss generation between steady and unsteady flow results shows that a design methodology under steady-state conditions is suitable to characterize the performance of different designs. Three design families were further assessed under highly transient transonic conditions including traveling shock waves with a relative total pressure amplitude of 149.6% around the mean value and inflow angle variations from -26.5 deg to +51.8 deg. The oblique shock impinging on the pressure side (PS) of the turbine augments the shaft power extraction. When the oblique shock reflects between the pressure side and suction side (SS), its strength diminishes. This paper provides design guidelines on efficient turbine work extraction from the shocks emanating from detonation combustors.

rotating detonation engines↗

Hydrogen Production System Scaling Using a High-Fidelity Simulation-Optimization Framework

Proton exchange membrane (PEM) electrolyzers are widely used for hydrogen production, yet few validated, high-fidelity tools can reliably guide scale-up. Using measured performance from a 50-hour hardware-in-the-loop pilot test, a physics-based, plant-level model of a 1.25 MW PEM electrolyzer and its balance-of-plant (BoP) subsystems is developed and validated. The model couples electrochemistry and thermal/flow submodels and is calibrated against pilot test data via a genetic algorithm (GA) workflow. Validation yields a mean absolute percentage error (APE) of 0.43% for cell voltage and stack power. Two scale-out strategies are then benchmarked under a common 7-day wind-and-photovoltaic (PV) profile: (i) linear duplication of 1.25 MW blocks and (ii) shared-BoP architectures. Sharing BoP between stacks reduces BoP energy by 27% at 10 MW and 34% at 100 MW (vs. linear duplication) and improves system specific energy consumption (SEC) to 52.9 and 52.6 kWh/kg, respectively (from 54.0 kWh/kg with linear duplication). Partial-load studies (25-100% set-point) show that cumulative hydrogen production remains nearly constant down to 50% load because all cases use the same weekly renewable-energy input. Below 50%, the power cap limits how much energy can be used within 168 h, which reduces hydrogen output. The model further indicates that the practical operating optimum lies between 50% and 85% load, where efficiency gains begin to appear without significant loss in hydrogen output. Moreover, the efficiency gains at lower loads are offset by reduced production. The validated framework supports scenario-based engineering trade-off studies for large configurations (10-100 MW) and for operating policies under variable renewables.

08 HYDROGEN↗

Mid- and long-term runoff predictions by an improved phase-space reconstruction model

In recent years, the phase-space reconstruction method has usually been used for mid- and long-term runoff predictions. However, the traditional phase-space reconstruction method is still needs to be improved. Using the genetic algorithm to improve the phase-space reconstruction method, a new nonlinear model of monthly runoff is constructed. The new model does not rely heavily on embedding dimensions. Recognizing that the rainfall–runoff process is complex, affected by a number of factors, more variables (e.g. temperature and rainfall) are incorporated in the model. In order to detect the possible presence of chaos in the runoff dynamics, chaotic characteristics of the model are also analyzed, which shows the model can represent the nonlinear and chaotic characteristics of the runoff. The model is tested for its forecasting performance in four types of experiments using data from six hydrological stations on the Yellow River and the Yangtze River. Results show that the medium-and long-term runoff is satisfactorily forecasted at the hydrological stations. Not only is the forecasting trend accurate, but also the mean absolute percentage error is no more than 15%. Moreover, the forecast results of wet years and dry years are both good, which means that the improved model can overcome the traditional ‘‘wet years and dry years predictability barrier,’’ to some extent. The model forecasts for different regions are all good, showing the universality of the approach. Compared with selected conceptual and empirical methods, the model exhibits greater reliability and stability in the long-term runoff prediction. Our study provides a new thinking for research on the association between the monthly runoff and other hydrological factors, and also provides a new method for the prediction of the monthly runoff. - Highlights: • The improved phase-space reconstruction model of monthly runoff is established. • Two variables (temperature and rainfall) are incorporated in the model. • Chaotic characteristics of the model are also analyzed. • The forecast results of the mid and long-term runoff in six stations are accurate.

97 MATHEMATICS AND COMPUTING↗

Learning model combining convolutional deep neural network with a self-attention mechanism for AC optimal power flow

Alternating current optimal power flow (OPF) analysis is critical for efficient and reliable operation of power systems. For large systems or repetitive computations, the traditional methods such as the direct and gradient methods, or non-traditional methods, such as the genetic algorithm and simulating annealing, are time-consuming and unsuitable for real-time computing. The work in this paper proposes a novel framework to obtain the optimal solution of power flow in real-time using a combination of convolutional neural networks and a self-attention mechanism. All parameters of the power networks are rearranged in an image-like shape of a multi-channel image where each channel is a two-dimensional matrix. The proposed approach is adaptive with every input size of power systems as well as frequent variations of network topologies without intervention to the framework core. The encompassment of all power system contexts in which all parameters of internal elements, generation costs, and topology information are included, contributes to the higher accuracy of inference compared to other current machine-learning-based OPF-solving methods. Besides, the proposed framework established on ubiquitous platforms is effortlessly integrated into current infrastructures of power systems, and the great efficiency along with the computation speed may serve as a critical point for practical implications, such as enabling faster decision-making during real-time operations, predicting system contingencies, and remedial actions based on an offline pre-trained model. Furthermore, this supervised learning process is applied to the dataset of four case studies of meshed power systems: the IEEE 5-bus system (IEEE-5), the IEEE 30-bus system (IEEE-30), the IEEE 39-bus system (IEEE-39), and the IEEE 57-bus system (IEEE-57) to prove the efficacy of the proposed method.

42 ENGINEERING↗

Experimental and numerical investigation on air-side performance of fin-and-tube heat exchangers with various fin patterns

Air-side heat transfer and friction characteristics of five kinds of fin-and-tube heat exchangers, with the number of tube rows (N = 12) and the diameter of tubes (D{sub o} = 18 mm), have been experimentally investigated. The test samples consist of five types of fin configurations: crimped spiral fin, plain fin, slit fin, fin with delta-wing longitudinal vortex generators (VGs) and mixed fin with front 6-row vortex-generator fin and rear 6-row slit fin. The heat transfer and friction factor correlations for different types of heat exchangers were obtained with the Reynolds numbers ranging from 4000 to 10000. It was found that crimped spiral fin provides higher heat transfer and pressure drop than the other four fins. The air-side performance of heat exchangers with the above five fins has been evaluated under three sets of criteria and it was shown that the heat exchanger with mixed fin (front vortex-generator fin and rear slit fin) has better performance than that with fin with delta-wing vortex generators, and the slit fin offers best heat transfer performance at high Reynolds numbers. Based on the correlations of numerical data, Genetic Algorithm optimization was carried out, and the optimization results indicated that the increase of VG attack angle or length, or decrease of VG height may enhance the performance of vortex-generator fin. The heat transfer performances for optimized vortex-generator fin and slit fin at hand have been compared with numerical method. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing fluvial flood mitigation strategies: A multi-objective approach for cost-effective and socially-aware infrastructure feasibility analysis

Effective levee planning must balance capital cost, risk reduction, and community priorities. These objectives are rarely optimized together. This study presents a feasibility phase, simulationin-the-loop framework that couples terrain-based flood modeling with a socially aware multiobjective optimizer. Flood risk is measured as Expected Annual Exposed Population (EAEP), obtained by integrating exposure over Annual Exceedance Probability (AEP) nodes, mirroring the Hydrologic Engineering Center's Flood Damage Reduction Analysis (HEC-FDA) expected-annual formulation but with people rather than dollars. Exposure per scenario is computed by overlaying binary inundation masks with a population surface at the tract level. Distributional fairness is encoded through a Group Benefit Share (GBS) constraint that requires high-SVI tracts to receive at least a baseline share of annualized benefits. Capital cost is represented by a height-dependent unit-cost model suitable for screening. This study addresses the two-objective problem, minimize cost and expected annual exposure subject to the GBS constraint, using Non-Dominated Sorting Genetic Algorithm II (NSGA-II) and leveraging Pareto front for feasibility phase decision making. Implemented with terrain-based flood modeling, GeoFlood, for rapid scenario evaluation, the framework is demonstrated in Southeast Texas. The results reveal clear trade-offs among cost, risk, and social benefits and identify non-dominated levee height configurations that satisfy the benefit-share floor. The contributions are a scalable decision support method that operationalizes expected annual population-based risk, embeds enforceable benefit-sharing guarantees, and uses lightweight simulation to explore large design spaces before higher fidelity design stages.

Flood mitigation↗

Optimum aggregation of geographically distributed flexible resources in strategic smart-grid/microgrid locations

This paper determines optimum aggregation areas for a given distribution network considering spatial distribution of loads and costs of aggregation. An elitist genetic algorithm combined with a hierarchical clustering and a Thevenin network reduction is implemented to compute strategic locations and aggregate demand within each area. The aggregation reduces large distribution networks having thousands of nodes to an equivalent network with few aggregated loads, thereby significantly reducing the computational burden. Furthermore, it not only helps distribution system operators in making faster operational decisions by understanding during which time of the day will be in need of flexibility, from which specific area, and in which amount, but also enables the flexibilities stemming from small distributed resources to be traded in various power/energy markets. A combination of central and local aggregation scheme where a central aggregator enables market participation, while local aggregators materialize the accepted bids, is implemented to realize this concept. The effectiveness of the proposed method is evaluated by comparing network performances with and without aggregation. Finally, for a given network configuration, steady-state performance of aggregated network is significantly accurate (≈ ±1.5% error) compared to very high errors associated with forecast of individual consumer demand.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparisons of amine solvents for post-combustion CO{sub 2} capture: A multi-objective analysis approach

Amine solvents are of great interest for post-combustion CO{sub 2} capture applications. Although the development of new solvents is predominantly conducted at the laboratory scale, the ability to assess the performance of newly developed solvents at the process scale is crucial to identifying the best solvents for CO{sub 2} capture. In this work we present a methodology to evaluate and objectively compare the process performance of different solvents. We use Aspen Plus, with the electrolyte-NRTL thermodynamic model for the solvent CO{sub 2} interactions, coupled with a multi-objective genetic algorithm optimization to determine the best process design and operating conditions for each solvent. This ensures that the processes utilized for the comparison are those which are best suited for the specific solvent. We evaluate and compare the process performance of monoethanolamine (MEA), diethanolamine (DEA), and 2-amino-2-methyl-1-propanol (AMP) in a 90% CO{sub 2} capture process from a 550 MW coal fired power plant. From our analysis the best process specifications are amine specific and with those specific, optimized specifications DEA has the potential to be a better performing solvent than MEA, with a lower energy penalty and lower capital cost investment.

20 FOSSIL-FUELED POWER PLANTS↗

Numerical modeling based machine learning approach for the optimization of falling - film evaporator in thermal desalination application

Scale formation that drastically increases thermal resistance and reduces freshwater production remains a critical challenge in thermal desalination. Novel designs of falling film evaporator and optimal operating condition hold great promise to mitigate scale formation, and increase heat transfer performance and fresh water production. In this work, CFD simulation based machine learning and multi-objective optimization are performed to identify optimal conditions and tube arrangement for evaporator. Non-dominated sorting genetic algorithm is adopted to determine and analyze the optimal pareto front for multiple objectives in desalination criteria. The errors of training, validation, and testing set are computed to identify an optimal hyperparameter set. For performance ratio, fouling resistance, and water production rate, the average relative error is 2.26%, 3.67%, and 3.24%. At pareto front, both performance ratio and water production rate increase at high temperature with fouling resistance (thermal resistance of the fouling layer) increasing as well. Tradeoffs between mitigating scale formation and enhancing desalination performance are evaluated in optimizations for different objectives. Finally, potential optima are identified and can be applied as guidelines to determine evaporator design and system operating conditions.

42 ENGINEERING↗

Prediction of novel stable Fe-V-Si ternary phase

Genetic algorithm searches based on a cluster expansion model are performed to search for stable phases of Fe-V-Si ternary. Here, we identify a new thermodynamically, dynamically and mechanically stable ternary phase of Fe 5 V 2 Si with 2 formula units in a tetragonal unit cell. The formation energy of this new ternary phase is -36.9 meV/atom below the current ternary convex hull. The magnetic moment of Fe in the new structure varies from -0.30-2.52 μ B depending strongly on the number of Fe nearest neighbors. The total magnetic moment is 10.44 μ B /unit cell for new Fe 5 V 2 Si structure and the system is ordinarily metallic.

36 MATERIALS SCIENCE↗

Accounting for uncertainty in complex alluvial aquifer modeling by Bayesian multi-model approach

Alluvial aquifers by nature are complex caused by varied depositional environments. Developing a reliable groundwater model to represent an alluvial aquifer is non-trivial. Also, relying on a single best calibrated model may not be sufficient because of an inadequate choice of model parameter values. To better understand groundwater dynamics and improve model prediction reliability, this study presents a Bayesian multi-model uncertainty quantification (BMMUQ) framework to account for model parameter uncertainty in complex alluvial groundwater modeling. The methodology was applied to the agriculturally intensive Mississippi River alluvial aquifer (MRAA), Northeast Louisiana. An aquifer architecture was first constructed using 7,259 well logs in the MRAA area which covers three fluvial deposits (alluvium, braided-stream terrace, and braided-stream terrace-loess). A 12-layer MODFLOW model was then developed to address the alluvial aquifer complexity and well calibrated through a genetic algorithm. This study quantified model parameter uncertainty in hydraulic conductivity and specific storage of sand facies. Bayesian model averaging (BMA) with the Expectation Maximization (EM) algorithm was adopted to derive posterior model weights and head variances of 50 alternative conceptual groundwater flow models, and thereby obtains BMA ensemble model predictions instead of only relying on the best calibrated conceptual model. Overall, results show that an estimated around 950 million m3 of groundwater storage loss occurs in 2015 with respect to the beginning of 2004, due to high groundwater demand for irrigation in the MRAA area. Explicitly quantifying model uncertainty can produce more reliable groundwater level predictions from BMA ensemble model. The presented groundwater modeling framework improves our understanding of the MRAA and provides a valuable tool to assist agricultural water management.

54 ENVIRONMENTAL SCIENCES↗

A comparison of helical and spur external gear machines for fluid power applications: Design and optimization

In this paper we address the problem of determining the relative performance of spur and helical external gear pumps (EGPs) for fluid power applications. Helical EGPs are commonly considered as quieter units than spur ones; however, there is no specific study reported in literature that proves such claim. Similarly, it is hard to find data indicating which design is better in terms of compactness or energy performance. To tackle this problem, a procedure is developed for virtual design optimization of both helical and spur gear EGPs. This includes addressing the two fundamental challenges of the work, parameterizing a generic EGP design and quantifying its performance. By applying this procedure, a genetic algorithm can continue improving from generation to generation, until the pareto optimal set of designs is identified for both helical and spur units. In the comparison of these, the differences between the two configurations will be identified and the fundamental question of this work can be answered; are helical gears ‘better’ than spur gears?

42 ENGINEERING↗

Machine learning maximized Anderson localization of phonons in aperiodic superlattices

Nanostructuring materials to achieve ultra-low lattice thermal conductivity has proven to be extremely attractive for numerous applications such as thermoelectric energy conversion. Anderson localization of phonons due to aperiodicity can reduce thermal conductivity in superlattices, but the lower limit of thermal conductivity remains elusive due to the prohibitively large design space. In this work, we demonstrate that an intuition-based manual search for aperiodic superlattice structures (random multilayers or RMLs) with the lowest thermal conductivity yields only a local minimum, while a genetic algorithm (GA) based approach can efficiently identify the globally minimum thermal conductivity by only exploring a small fraction of the design space. Our results show that this minimum value occurs at an average RML period that is, surprisingly, smaller than the period corresponding to the minimum SL thermal conductivity. Interestingly, above this critical period, scattering of incoherent phonons at interfaces is less, whereas below this period, the room for randomization becomes less, thus putting more coherent phonons out of Anderson localization and causing increased thermal conductivity. Moreover, the lower limit of the thermal conductivity occurs at a moderate rather than maximum randomness of the layer thickness. Our machine learning approach demonstrates a general process of exploring an otherwise prohibitively large design space to gain non-intuitive physical insights.

42 ENGINEERING↗

Focus optimization at relativistic intensity with high numerical aperture and adaptive optics

Improved focusing of laser beams using high numerical aperture systems is an efficient route to increasing intensities in the ultrafast regime to relativistic levels. We experimentally demonstrate a new method of optimizing the focus of a high-power laser, using second harmonic generation at full intensity in a low-pressure gas to provide a figure of merit for optimizing the shape of a deformable mirror via a genetic algorithm. Nonlinear and thermal aberrations are corrected, and aberrations introduced by filters are avoided. Furthermore, the method is applied to focus a millijoule, short pulse (30 fs), high repetition rate laser system to relativistic intensity in both near IR and mid IR regimes.

Lin, Jinpu↗

Life cycle assessment and tempo-spatial optimization of deploying dynamic wireless charging technology for electric cars

Dynamic wireless power transfer (DWPT), or dynamic wireless charging technology, enables charging-while-driving and offers opportunities for eliminating range anxiety, stimulating market penetration of electric vehicles (EVs), and enhancing the sustainability performance of electrified transportation. However, the deployment of wireless charging lanes on highways and urban road networks can be costly and resource-intensive. A life cycle assessment (LCA) is conducted here to compare the sustainability performance of DWPT applied in a network of highways and urban roads for charging electric passenger cars. The assessment compares DWPT to stationary wireless charging and to conventional plug-in charging using a case study of Washtenaw County in Michigan, USA over 20 years. The LCA is based on three key sustainability metrics: costs, greenhouse gas (GHG) emissions, and energy burdens, encompassing not only the use-phase burdens from electricity and fuel, but also the upfront deployment burdens of DWPT infrastructure. A genetic algorithm is applied to optimize the rollout of DWPT infrastructure both spatially and temporally in order to minimize life cycle costs, GHG, and energy burdens: (1) spatial optimization selects road segments to deploy DWPT considering traffic volume, speed, and pavement remaining service life (RSL); (2) temporal optimization determines in which year to deploy DWPT on a particular road segment considering EV market share growth as a function of DWPT coverage rate, future DWPT cost reduction, and charging efficiency improvement. Results indicate that optimal deployment of DWPT electrifying up to about 3% of total roadway lane-miles reduces life cycle GHG emissions and energy by up to 9.0% and 6.8%, respectively, and enables downsizing of the EV battery capacity by up to 48%, compared to the non-DWPT scenarios. Roadside solar panels and storage batteries are essential to significantly reduce life cycle energy and GHG burdens but bring additional costs. Breakeven analysis indicates a breakeven year for solar charging benefits to pay back the DWPT infrastructure burdens can be less than 20 years for GHG and energy burdens but longer than 20 years for costs. A monetization of carbon emissions of at least $250 per metric tonne of CO 2 is required to shift the optimal “pro-cost” deployment to the optimal “pro-GHG” deployment. A roadway segment with volume greater than about 26,000 vehicle counts per day, speed slower than 55 miles per hour (1 mile ≈ 1.609 km), and pavement RSL shorter than 3 years should be given a high priority for early-stage DWPT deployment.

33 ADVANCED PROPULSION SYSTEMS↗

Optimizing the location and configuration of disaster resilience hubs under transportation and electric power network failures

Natural disasters often result in failures of transportation network components and blackouts that imperil the wellbeing of vulnerable populations. In response to these events, resilience hubs have been proposed as a pre-disaster planning strategy to improve access to critical services. This paper introduces an optimization-based approach to locate and configure electric power-generating resilience hubs considering the possibility of failures in transportation and electric power systems. The model's objective is to identify hub locations and configurations that maximize transportation accessibility to the hubs and maximize the satisfaction of basic energy needs through hub-generated electric power. Besides a budget constraint, the model accounts for limits on the levels of hub energy generation vis-à-vis community energy demands, and on the transportation network distance of communities to hubs. Three heuristics are presented for the proposed planning problem. The first heuristic is a genetic algorithm (GA) with problem-specific solution generation procedures. The other two heuristics implement greedy search techniques. Numerical experiments were conducted, using data from rural Puerto Rico, to illustrate the application of the proposed model and heuristics, and examine their performance. In the numerical experiments, the GA heuristic found better solutions than the greedy heuristics. Additionally, design solutions consisting of spatially dispersed hubs with low energy generation capacity were better than solutions with spatially concentrated high-capacity hubs. Lastly, across a wide range of hub demand scenarios, only a small number of candidate hub locations consistently ranked among the best locations for establishing a hub.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗