Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Basic Research Needs for Future Nuclear Energy: Report of the Basic Energy Sciences Workshop for Future Nuclear Energy, August 9-11, 2017

Nuclear power today accounts for approximately 20% of the electrical supply for the US. It provides reliable energy that helps to stabilize the national grid. In contrast to current nuclear power facilities, future concepts operate at higher temperatures, are operationally more efficient, more fully utilize the energy stored within the fuel, and reduce the amount of waste produced. Recent advances in chemistry and materials sciences provide an unprecedented opportunity to develop the critical systems—the fuel, coolant, and structural materials—needed for deployment of advanced nuclear reactor designs. To address the challenge of stringent demands on material systems as their properties and performance continuously evolve over the operational lifetime, the frameworks to uncover the underlying processes that cause reduced performance have been developed over the last decade. There is now the prospect of designing materials that report upon their own damage, are self-healing, and leverage what would be considered deleterious chemical processes to increase their performance within advanced reactor designs. Success will provide an energy source needed to secure a stable and safe energy supply for the nation. To identify the key research directions required to discover the chemical processes and material degradation mechanisms that result in loss of performance of the fuel, coolant, and structural materials, nearly 150 theoreticians, computational experts, and experimentalists from industry, national laboratories, academia, and federal agencies participated in a workshop held in August 2017. Based on the discussions held at the workshop, five Priority Research Directions (PRDs) were identified. These PRDs defined the key scientific challenges that must be met as well as the opportunities that can be exploited to achieve a multi-scale spatial and temporal understanding of fundamental processes that govern the properties and performance of the different material systems required for advanced reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications: Third Edition

As the world looks for low-carbon sources of energy, solar power stands out as the single most abundant energy resource on Earth. Harnessing this energy is the challenge for this century. Photovoltaics, solar heating and cooling, and concentrating solar power (CSP) are primary forms of energy applications using sunlight. These solar energy systems use different technologies, collect different fractions of the solar resource, and have different siting requirements and production capabilities. Reliable information about the solar resource is required for every solar energy application. This holds true for small installations on a rooftop as well as for large solar power plants; however, solar resource information is of particular interest for large installations because they require substantial investment, sometimes exceeding 1 billion dollars in construction costs. Before such a project is undertaken, the best possible information about the quality and reliability of the fuel source must be made available. That is, project developers need reliable data about the solar resource available at specific locations, including historic trends with seasonal, daily, hourly, and (preferably) subhourly variability to predict the daily and annual performance of a proposed power plant. Without these data, an accurate financial analysis is not possible. Additionally, with the deployment of large amounts of distributed photovoltaics, there is an urgent need to integrate this source of generation to ensure the reliability and stability of the grid. Forecasting generation from the various sources will allow for larger penetrations of these generation sources because utilities and system operators can then ensure stable grid operations. Developed by the foremost experts in the field who have come together under the umbrella of the International Energy Agency’s Solar Heating and Cooling Task 46, this handbook summarizes state-of-the-art information about all these topics.

14 SOLAR ENERGY↗

Universal Battery Supercharger

During the course of the UBS project a dc-fast charger was developed to be used in off board high power charging stations. High efficiency is targeted to reduce the charging price for the consumer while reducing the charge time. In the meantime, the size of the converter is minimized so that it could be used in small spaces and potentially urban areas. The topology is modular, and the power level can be expanded for charging higher power vehicles like trucks and buses. During the course of this research several key technologies was developed in LESES that improve the performance of the power electronics system used in EV charger. Integrated magnetics was developed for DMCR to improve the power density as well as efficiency of the magnetic components which is one of the main bottlenecks of EV development. Triangular mode EV current conduction mode is using to perform soft switching (increase efficiency) without adding any new components to the existing topology. Passive and active damping are developed to suppress the interaction between grid and converter, stabilizing the control system. Further numerous other technical problems have been solved to pave the way for even higher performance converters in the future.

25 ENERGY STORAGE↗

Feasibility Analyses for the Microgrid of the Mountain in the Cordillera Central Region of Puerto Rico

Distributed energy resource (DER) development can benefit communities through improvement of access to reliable electricity and a resilient energy system. Many place-specific considerations must be accounted for when designing electrical systems with co-located generation and loads. This paper presents an overview of four studies focusing on different aspects for regional DER development in the Cordillera Central region of Puerto Rico, including a grid and load stability study with the introduction of solar energy generation, microgrid design based on the solar resource in the area, resilience considerations during power outage scenarios, and qualitative risk aspects for components in the microgrid. Additionally, a conceptual substation microgrid analysis is conducted using the Microgrid Design Toolkit (MDT) to evaluate trade-offs between cost and energy availability, providing insights into optimal design strategies. A microgrid resilience assessment is performed using the Resilient Nodal Cluster Analysis Tool (ReNCAT) to identify critical loads and evaluates their accessibility during outages, emphasizing the importance of community needs. Finally, a qualitative risk assessment utilizing Hazard and Operability Analysis (HAZOP) methods highlights potential hazards and mitigations for microgrid components, ensuring robust system design and operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Feature-Based PMU Event Classification under Variable PMU Participation and Overlapping Events

Danovo Energy Solution's presented its paper named: Feature-Based PMU Event Classification under Variable PMU Participation and Overlapping Events at the 2026 Georgia Tech Fault & Disturbance Analysis Conference. The full paper can be found at OSTI ID# 3169150 Paper Abstract—Phasor Measurement Units (PMUs) stream time synchronized, high-resolution measurements from the grid, enabling data-driven techniques for event detection and classification. Accurate event classification improves grid reliability and stability. Events can be detected by varying numbers of PMUs and exhibit different durations depending on the event type. This variability challenges standard classifiers that require uniform input sizes. Moreover, multiple events may coincide, which increases classification complexity. Standard classifiers assign each instance to the class with the highest predicted probability, whereas overlapping events may exhibit comparable probabilities across multiple classes. In this study, to handle data size variability, we extract a wide range of time–frequency domain features from all available PMUs for each event into a fixed-length vector, facilitating the application of standard machine learning classifiers, including Random Forest, XGBoost, LightGBM, Support Vector Machine, and Multilayer Perceptron. To account for overlapping events, a probabilistic post-processing step is applied. For a given data instance, if multiple predicted class probabilities exceed 30% and the differences between them are less than 10%, the event is assigned to multiple classes. Experiments using real-world PMU data demonstrate that the Random Forest and XGBoost models achieve the highest accuracy, while the proposed post-processing method yields perfect classification performance on external unseen test sets.

Nematirad, Reza [Danova Energy Solutions]↗

A Comprehensive Comparison of Methods for Evaluating Dispatch of Long-Duration Energy Storage in Power Systems Models

Long-duration energy storage (LDES) could play a pivotal role in the transformation of electricity grids with high shares of variable renewable energy (VRE) such as solar and wind. However, the weather-dependent nature of VRE introduces challenges for grid balancing and stability, which LDES - along with short-duration energy storage (SDES) - can help address. However, modeling LDES in production cost models (PCMs) is particularly challenging due to the need for high temporal resolution over extended optimization windows while preserving chronology, which ensures the alignment of energy storage operations with VRE generation over multi-day periods. This report compares traditional dispatch methods with advanced LDES dispatch strategies, such as the extended horizon approach, across different PCM platforms and examines tradeoffs and scalability. The comparison reveals that the traditional 1-day optimization horizon within the PCM leads to inefficient utilization of LDES. In contrast, extending the optimization horizon as much as possible significantly reduces curtailment and improves storage dispatch, especially in renewable-dense systems. There is also promise in using state-of-charge or end volume targets set by an external model, however this requires an additional modeling set and generally increases computational burden. This paper presents a comparison of these various methods in a number of power systems, showing algorithms initially in small test systems and scaling up to large, country-wide simulations. Overall, the research presents the trade-offs of various computational methods and illustrates how LDES may play an essential role in power systems of the future.

14 SOLAR ENERGY↗

City-Scale Building Anthropogenic Heating during Heat Waves

More frequent and longer duration heat waves have been observed worldwide and are recognized as a serious threat to human health and the stability of electrical grids. Past studies have identified a positive feedback between heat waves and urban heat island effects. Anthropogenic heat emissions from buildings have a crucial impact on the urban environment, and hence it is critical to understand the interactive effects of urban microclimate and building heat emissions in terms of the urban energy balance. Here we developed a coupled-simulation approach to quantify these effects, mapping urban environmental data generated by the mesoscale Weather Research and Forecasting (WRF) coupled to Urban Canopy Model (UCM) to urban building energy models (UBEM). We conducted a case study in the city of Los Angeles, California, during a five-day heat wave event in September 2009. We analyzed the surge in city-scale building heat emission and energy use during the extreme heat event. We first simulated the urban microclimate at a high resolution (500 m by 500 m) using WRF-UCM. We then generated grid-level building heat emission profiles and aggregated them using prototype building energy models informed by spatially disaggregated urban land use and urban building density data. The spatial patterns of anthropogenic heat discharge from the building sector were analyzed, and the quantitative relationship with weather conditions and urban land-use dynamics were assessed at the grid level. The simulation results indicate that the dispersion of anthropogenic heat from urban buildings to the urban environment increases by up to 20% on average and varies significantly, both in time and space, during the heat wave event. The heat dispersion from the air-conditioning heat rejection contributes most (86.5%) of the total waste heat from the buildings to the urban environment. We also found that the waste heat discharge in inland, dense urban districts is more sensitive to extreme events than it is in coastal or suburban areas. The generated anthropogenic heat profiles can be used in urban microclimate models to provide a more accurate estimation of urban air temperature rises during heat waves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Commercial Building Lighting as a Frequency Regulation Resource

This paper evaluates the potential for automated lighting control as a resource for frequency regulation of the electric grid system in the context of current energy policies, economic incentives, and technological trends. The growing prevalence of renewable energy has increased the need for ancillary services to maintain grid frequency and stability. While demand side resources like heating, ventilating, and air-conditioning systems, as well as water treatment plants are already evaluated as regulation service providers, the potential application to electrical lighting systems has largely been ignored. Yet, aggregations of lighting systems that are retrofitted with intelligent controls could conceivably contribute to frequency regulation services with little impact on user comfort. To further explore the feasibility of lighting potential, this paper explores (1) how lighting control systems are limited by visual comfort perception and acceptability, (2) how such limitations impact the performance of the lighting system as an frequency regulation resource, and (3) how the market potential of lighting systems as demand side resources compares in different regional transmission organizations. Finally, the impact of developing technologies on the application of lighting systems for frequency regulation is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Improved Neutron Transport Algorithm for HZETRN

Long term human presence in space requires the inclusion of radiation constraints in mission planning and the design of shielding materials, structures, and vehicles. In this paper, the numerical error associated with energy discretization in HZETRN is addressed. An inadequate numerical integration scheme in the transport algorithm is shown to produce large errors in the low energy portion of the neutron and light ion fluence spectra. It is further shown that the errors result from the narrow energy domain of the neutron elastic cross section spectral distributions, and that an extremely fine energy grid is required to resolve the problem under the current formulation. Two numerical methods are developed to provide adequate resolution in the energy domain and more accurately resolve the neutron elastic interactions. Convergence testing is completed by running the code for various environments and shielding materials with various energy grids to ensure stability of the newly implemented method.

Slaba, Tony C.↗

Optimal Solar PV Arrays Integration for Distributed Generation

Solar photovoltaic (PV) systems hold great potential for distributed energy generation by installing PV panels on rooftops of residential and commercial buildings. Yet challenges arise along with the variability and non-dispatchability of the PV systems that affect the stability of the grid and the economics of the PV system. This paper investigates the integration of PV arrays for distributed generation applications by identifying a combination of buildings that will maximize solar energy output and minimize system variability. Particularly, we propose mean-variance optimization models to choose suitable rooftops for PV integration based on Markowitz mean-variance portfolio selection model. We further introduce quantity and cardinality constraints to result in a mixed integer quadratic programming problem. Case studies based on real data are presented. An efficient frontier is obtained for sample data that allows decision makers to choose a desired solar energy generation level with a comfortable variability tolerance level. Sensitivity analysis is conducted to show the tradeoffs between solar PV energy generation potential and variability.

Omitaomu, Olufemi A↗

PCM Selection for Heat Pump Integrated with Thermal Energy Storage for Demand Response in Residential Buildings

Phase Change Materials (PCM) based Thermal energy storage (TES) is a widespread solution to shift buildings’ peak energy demand and add stability to the grid. PCMs can be used for space heating and cooling applications in residential buildings by integrating into the heat pump equipment or building envelope via several possible configurations. The heat pump integrated active PCM storage can provide significant energy savings and reduce peak demand, but the benefits vary substantially depending on the system configuration, storage capacity, and the temperature range of the PCM used. It is critical to provide a review of the materials and their suitability in heat pump integrated PCM systems. This paper will present an analysis of the PCM material selection for heat pump integrated TES in various configurations. The comprehensive review will compare the phase change materials with different melting temperatures, and configurations, corresponding to the energy savings and demand impact reported in the literature. This work is significant to guide the design of high-performance heat pump integrated PCM systems.

Sultan, Sara↗

Feature-Based PMU Event Classification under Variable PMU Participation and Overlapping Events

This paper is the basis for a presentation help at the 2026 Georgia Tech Fault & Disturbance Analysis Conference, which can be found at OSTI # 3168287 Paper Abstract—Phasor Measurement Units (PMUs) stream time synchronized, high-resolution measurements from the grid, enabling data-driven techniques for event detection and classification. Accurate event classification improves grid reliability and stability. Events can be detected by varying numbers of PMUs and exhibit different durations depending on the event type. This variability challenges standard classifiers that require uniform input sizes. Moreover, multiple events may coincide, which increases classification complexity. Standard classifiers assign each instance to the class with the highest predicted probability, whereas overlapping events may exhibit comparable probabilities across multiple classes. In this study, to handle data size variability, we extract a wide range of time–frequency domain features from all available PMUs for each event into a fixed-length vector, facilitating the application of standard machine learning classifiers, including Random Forest, XGBoost, LightGBM, Support Vector Machine, and Multilayer Perceptron. To account for overlapping events, a probabilistic post-processing step is applied. For a given data instance, if multiple predicted class probabilities exceed 30% and the differences between them are less than 10%, the event is assigned to multiple classes. Experiments using real-world PMU data demonstrate that the Random Forest and XGBoost models achieve the highest accuracy, while the proposed post-processing method yields perfect classification performance on external unseen test sets.

Nematirad, Reza [Danovo Energy Solutions]↗

Investigating Inherent Numerical Stabilization for the Moist, Compressible, Non‐Hydrostatic Euler Equations on Collocated Grids

This study investigates inherent numerical dissipation due to upwind fluxes and reconstruction strategies for collocated Finite-Volume integration of the Euler equations. Idealized supercell simulations are used without any explicit dissipation. Flux terms are split into: mass flux, pressure, and advected quantities. They are computed with the following upwind strategies: central, advectively upwind, and acoustically upwind. This is performed for third and ninth-order-accurate reconstructions with and without Weighted Essentially Non-Oscillatory limiting. Acoustic-only upwinding for pressure and mass flux terms and advective-only upwinding for advected quantities is the most flexible simplification found. It reduces data movement and computations. Assuming a constant speed of sound in acoustic upwinding gives similar results to using the true speed of sound. Dissipation from upwind adapts automatically to grid spacing, time step, reconstruction accuracy, and flow smoothness. While stability is maintained even at 21st-order spatial accuracy, there is a limit to the spatial order of accuracy for which upwinding alone can create a realizable solution in the conditions of this study. Convex combinations of upwind and central solutions for flux terms also reduced dissipation, but as the central proportion grows, solutions become physically unrealizable. The range of length scales of the kinetic energy spectra can be extended along k −5/3 to smaller spatial scales by reducing dissipation either with higher-order reconstructions or using convex combinations of upwind and central fluxes. However, not all extensions of the length scale range along k −5/3 exhibit physically realizable solutions, even though the spectra appear to be physical.

54 ENVIRONMENTAL SCIENCES↗

Advanced Solar and Load Forecasting Incorporating HD Sky Imaging: BNL Phase II Activities (Final Report)

Over the last ten years, lower costs and government incentives for rooftop and utility scale solar photovoltaic (PV) systems have led to a rapid growth in the amount of power generated from this renewable energy source. For example, the cumulative PV generating capacity of 1,160 MW in New York State at the end of 2018 represents a growth of more than 4,000% over the past seven years and almost 400% over the past five years. But increased dependence on this inherently variable energy source introduces the need to anticipate, i.e., forecast, changes in energy production and manage them appropriately. Utilities and grid operators can then use this forecast information to balance changes and maintain stability of the electric grid by adding additional sources or diverting excess supplies for sale or storage, as needed. Current techniques based on persistence modeling are not accurate enough to provide reliable forecasts. With support from the U.S. Department of Energy’s Solar Energy Technology Office (DOE SETO) and the New York Power Authority (NYPA), Brookhaven National Laboratory (BNL), the National Center for Atmospheric Research (NCAR), and the Electric Power Research Institute (EPRI) formed a collaborative team to provide reliable forecasting over a range of time intervals. In addition, the forecasting area was scaled up to about 50 km2, a factor of 20 times larger than previously achieved, so that available solar irradiance could be forecast throughout an entire region including both large generating facilities and distributed rooftop solar arrays. In its role, BNL developed a technology for predicting changes in available solar energy from zero to 30 minutes ahead. This “nowcasting” approach uses inexpensive, off-the-shelf, high definition (HD) imagers with custom software to identify and track the movement of approaching clouds and predict their impact on available solar irradiance. The BNL Nowcasting model improves forecasting accuracy by 20 to 50% over current techniques. Forecasting reliability for low clouds (worst case scenario since they move over solar panels more rapidly than high clouds) was calculated to be 95% accurate for forecast periods of five minute ahead. Reliability decreases with longer forecast time intervals and was calculated to be about 80% for 10 minute forecasts, and about 70% for 20 minutes ahead. Clouds were still reliably tracked by the imager network at 60% accuracy for forecast lead times up to about 30 minutes ahead, and this was determined to be the practical nowcasting limit for low clouds in a network of this scale. This work represents the second phase of a multi-phase effort to develop and deploy solar forecasting at a regional scale so that contributions from distributed rooftop solar resources can be forecast along with solar generating facilities, giving utilities and stakeholders an accurate assessment of future energy production. Additional work is planned to operate the forecasting network in an area upstate New York to assess system reliability under diverse meteorological conditions and to monitor system performance over a full range of seasonal variability.

14 SOLAR ENERGY↗

Advanced Distributed Wind Turbine Controls Series: Part 2-Wind Energy in Isolated Grids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In an isolated grid, wind turbines are typically deployed to provide energy to maximize energy production, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, advanced wind turbine controls that can be employed to support higher contributions of wind in isolated grids, and to demonstrate ways that wind can play a role in supporting stability of an isolated grid. This isolated grid used in these desktop simulations is comprised of a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a simulated diesel generator (2 MW) and various types of loads (critical, dynamic). We developed a model of the subsystems in MATLAB/Simulink and validated them with available data from real-world components on NREL's Flatirons Campus. These validated models are then configured for various case studies. We compare the output of the desktop simulation with a baseline case with the diesel generator. Active and reactive power control of the wind turbine can help improve frequency and voltage responses in the isolated grid, respectively. By utilizing a small integrated battery energy storage system in the DC-link of the wind turbine, we also demonstrate that wind turbines can help blackstart a critical load comparable to its rated power and support other renewables (e.g. solar PV) come online and pick up an additional load. This report illustrates some of these reliability and resilience services a wind turbine can provide in an isolated grid.

17 WIND ENERGY↗

Open Source High Fidelity Modeling Of A Type-5 Wind Turbine Drivetrain

The purpose of this code is to provide a high-fidelity model of Type-5 wind turbine drivetrain for grid integration and transient stability studies. The increasing integration of renewable energy resources in evolving bulk power system (BPS) is impacting the system’s inertia. Type-5 wind turbine generation has the potential to behave like a traditional synchronous generator and can help mitigate the aforementioned impact. A hydraulic torque converter (TC) and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine unit. A generic and high-fidelity model of a Type-5 wind turbine drivetrain is not openly and widely available for grid integration and transient stability studies. This hinders appropriate assessment of Type-5 wind power plant's contribution to the BPS resilience. This work develops and validates a TC model based on those generally used in automobile's transmission system.

Hussain, Tanveer↗

Model-Free Control of Grid-Interactive Efficient Buildings Under Communication Time Delays

Grid-interactive efficient buildings (GEBs) have recently been used to enhance the reliability and stability of the electric grid through demand response (DR) programs. However, most existing DR control strategies require accurate modeling of the various building thermostatically controlled loads (TCLs) and are computationally expensive. To address these challenges, a model-free control (MFC)-based strategy has recently been introduced for coordinating and controlling GEBs. MFC is a data-enabled control strategy that is computationally efficient and does not require the analytical models of the various building equipment. In this paper, we numerically investigate the impact of communication time delays on the performance of MFC in maintaining the TCLs' temperatures within the desired comfort levels while meeting the assigned power allocation constraint.

Telsang, Bhagyashri [University of Tennessee, Knox↗

Li + -Desolvation Dictating Lithium-Ion Battery’s Low-Temperature Performances

Lithium (Li) ion battery (LIB) has penetrated almost every aspects of human life, from portable electronics, vehicles to grids, and its operation stability in extreme environments becomes increasingly important. Among these, sub-zero temperature presents a kinetic challenge to the electrochemical reactions required to deliver the stored energy. In this work, we attempted to identify the rate-determining process for Li+ migration under such low temperatures, so that an optimum electrolyte formulation could be designed to maximize the energy output. Substantial increase in available capacities from graphite||LiNi0.80Co0.15Al0.05O2 chemistry down to -40°C is achieved by reducing the solvent molecule that more tightly binds to Li+ and thus constitutes high desolvation energy barrier. The fundamental understanding is applicable universally to all electrochemical devices that have to operate in similar environments.

desolvation↗