Search NASA⌕ Search

SEARCH · Search NASA

Results for “HOLOGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Real-Time, Holographic, Dynamic Image-Storage Device

Solid-state device developed for high-speed acquisition, dynamic storage, and amplification of three-dimensional holographic images. Holograms generated via four-wave mixing in two or more photorefractive crystals (or subelements of single crystal) to create single-crystal or multicrystal oscillator. Apparatus provides dynamic storage of holographic image of object after electronic shutter closed to turn off object beam. Provides capability to store, amplify, process, and transmit time-varying, two-dimensional, spatial information. Developments include sensors, actuators, and optical computers operating at speeds on order of speed of light. Potential in applications in which need for high-speed acquisition and storage of three-dimensional holographic images.

Montgomery, Raymond C.↗

Holographic Compact Disk Read-Only Memories

Compact disk read-only memories (CD-ROMs) of proposed type store digital data in volume holograms instead of in surface differentially reflective elements. Holographic CD-ROM consist largely of parts similar to those used in conventional CD-ROMs. However, achieves 10 or more times data-storage capacity and throughput by use of wavelength-multiplexing/volume-hologram scheme.

Liu, Tsuen-Hsi↗

Investigation of the Influence of Microgravity on Transport Mechanism in a Virtual Spaceflight Chamber: A Flight Definition Program

A need exists for understanding precisely how particles move and interact in a fluid in the absence of gravity. Such understanding is required, for example, for modeling and predicting crystal growth in space where crystals grow from solution around nucleation sites as well as for any study of particles or bubbles in liquids or in experiments where particles are used as tracers for mapping microconvection. We have produced an exact solution to the general equation of motion of particles at extremely low Reynolds number in microgravity that covers a wide range of interesting conditions. We have also developed diagnostic tools and experimental techniques to test the validity of the general equation . This program, which started in May, 1998, will produce the flight definition for an experiment in a microgravity environment of space to validate the theoretical model. We will design an experiment with the help of the theoretical model that is optimized for testing the model, measuring g, g-jitter, and other microgravity phenomena. This paper describes the goals, rational, and approach for the flight definition program. The first objective of this research is to understand the physics of particle interactions with fluids and other particles in low Reynolds number flows in microgravity. Secondary objectives are to (1) observe and quantify g-jitter effects and microconvection on particles in fluids, (2) validate an exact solution to the general equation of motion of a particle in a fluid, and (3) to characterize the ability of isolation tables to isolate experiments containing particle in liquids. The objectives will be achieved by recording a large number of holograms of particle fields in microgravity under controlled conditions, extracting the precise three-dimensional position of all of the particles as a function of time and examining the effects of all parameters on the motion of the particles. The feasibility for achieving these results has already been established in the ongoing ground-based NRA, which led to the "virtual spaceflight chamber" concept.

Trolinger, James D.↗

Multiplexed Holographic Data Storage in Bacteriorhodopsin

Biochrome photosensitive films in particular Bacteriorhodopsin exhibit features which make these materials an attractive recording medium for optical data storage and processing. Bacteriorhodopsin films find numerous applications in a wide range of optical data processing applications; however the short-term memory characteristics of BR limits their applications for holographic data storage. The life-time of the BR can be extended using cryogenic temperatures [1], although this method makes the system overly complicated and unstable. Longer life-times can be provided in one modification of BR - the "blue" membrane BR [2], however currently available films are characterized by both low diffraction efficiency and difficulties in providing photoreversible recording. In addition, as a dynamic recording material, the BR requires different wavelengths for recording and reconstructing of optical data in order to prevent the information erasure during its readout. This fact also put constraints on a BR-based Optical Memory, due to information loss in holographic memory systems employing the two-lambda technique for reading-writing thick multiplexed holograms.

Mehrl, David J.↗

Inspection of Space Station Cold Plate Using Visual and Automated Holographic Techniques

Real-time holography has been used to confirm the presence of non-uniformity in the construction of an International Space Station cold plate. Ultrasonic C-scans have previously shown suspected areas of cooling fin disbonds. But both neural-net processed and visual holography did not evidence any progressive permanent changes resulting from 3000 pressurization and relaxation cycles of a Dash 8 cold plate. Neural-net and visual inspections were performed of characteristic patterns generated from electronic time-average holograms of the vibrating cold plate. Normal modes of vibration were excited at very low amplitudes for this purpose, The neural nets were trained to flag very small changes in the mode shapes as encoded in the characteristic patterns. Both the whole cold plate and a zoomed region were inspected. The inspections were conducted before, after, and during pressurization and relaxation cycles of the cold plate. A water-filled cold plate was pressurized to 120 psig (827 kPa) and relaxed for each cycle. Each cycle required 5 seconds. Both the artificial neural networks and the inspectors were unable to detect changes in the mode shapes of the relaxed cold plate. The cold plate was also inspected visually using real-time holography and double-exposure holography. Regions of non-uniformity correlating with the C-scans were apparent, but the interference patterns did not change after 3000 pressurization and relaxation cycles. These tests constituted the first practical application of a neural-net inspection technique developed originally with support from the Director's Discretionary Fund at the Glenn Research Center at Lewis Field.

Decker, Arthur J.↗

Analysis of Spacelab-III Reconstructed Wavefronts by Non-Holographic Methods

Holography has been used in several past space missions. One popular experimental mode deals with study of fluid refractive properties in the crystal growth cell. The perceived advantage of holography is that it stores and reconstructs wavefronts so that a complete information is available later on ground. That means the wavefront can be analyzed not only by traditional holographic interferometry but other means as well. We have successfully demonstrated two such means being described here. One is deflectometry using a Ronchi grating and the other confocal optical processing. These results, using holograms from Spacelab-III mission dealing with triglycine sulfate crystal growth clearly demonstrate that a single hardware (holography) can do the task of several fluid experimental systems. Finally, not experimentally demonstrated, the possibility of some other analysis modes like speckle techniques and video holography using the reconstructed wavefronts have been described. Since only traditional holographic interferometry has been used in the past leading to the argument that non-holographic interferometry hardware in space could do the job, the present study firmly establishes advantage of holography.

Vikram, Chandra S.↗

Holographic Optical Data Storage

Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising, and security medium as well. The evolution of holographic optical memories has followed a path not altogether different from holography itself, with several cycles of alternating interest over the past four decades. P. J. van Heerden is widely credited for being the first to elucidate the principles behind holographic data storage in a 1963 paper, predicting bit storage densities on the order of 1/lambda(sup 3) with source wavelength lambda - a fantastic capacity of nearly 1 TB/cu cm for visible light! The science and engineering of such a storage paradigm was heavily pursued thereafter, resulting in many novel hologram multiplexing techniques for dense data storage, as well as important advances in holographic recording materials. Ultimately, however, the lack of such enabling technologies as compact laser sources and high performance optical data I/O devices dampened the hopes for the development of a commercial product. After a period of relative dormancy, successful applications of holography in other arenas sparked a renewed interest in holographic data storage in the late 1980s and the early 1990s. Currently, with most of the critical optoelectronic device technologies in place and the quest for an ideal holographic recording medium intensified, holography is once again considered as one of several future data storage paradigms that may answer our constantly growing need for higher-capacity and faster-access memories.

Timucin, Dogan A.↗

Measurements of Holographic Properties of Bacteriorhodopsin Films

Several different bacteriorhodopsin (BR) films are characterized with respect to general holographic properties. Experimental measurements include diffraction efficiency and sensitivity as functions of writing intensity and grating frequency, hologram thermal decay behavior, diffraction efficiency as a function of grating tilt within the film and modulation depth, and estimates of the refractive index change from the diffraction efficiency data. The films studied include those made from wildtype BR and the genetic variants D96N and D96N/T46V. The maximum diffraction efficiency measured was just over 3% for a hydrated wildtype BR film. The films' holographic properties were found to be relatively insensitive to grating frequency and grating tilt angle. The diffraction efficiency dropped off more sharply as a function of modulation depth than a purely linear medium, and only the hydrated wildtype film exhibited significant behavior variation with different writing intensities.

Downie, John D.↗

Design, Fabrication, Optical Testing, and Performance of Diamond Machined Aspheric Mirrors for Ground-Based Near-IR Astronomy

Challenges in fabrication and testing have historically limited the choice of surfaces available for the design of reflective optical instruments. Spherical and conic mirrors are common, but, for future science instruments, more degrees of freedom are necessary to meet challenging performance and packaging requirements. These instruments will be composed of unusual aspheres located far off-axis with large spherical departure, and some designs will require asymmetric surface profiles. In particular, single-surface astigmatism correction in spectrographs necessitates a toroidal surface, which lacks an axis of rotational symmetry. We describe the design, fabrication, optical testing, and performance of three rotationally symmetric, off-axis, aspheric mirrors and one toroidal, off-axis, biconic camera mirror on aluminum substrates for the Infrared Multi-Object Spectrograph (IRMOS) instrument. IRMOS is a facility instrument for the Kitt Peak National Observatory's Mayall Telescope (3.8 m) and an engineering prototype for a possible design of the Next Generation Space Telescope/Multi-Object Spectrograph. The symmetric mirrors range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. They are various off-axis, convex and concave, prolate and oblate ellipsoids. The concave biconic mirror has a 94x76 mm aperture, Rx=377 mm, kx=0.0778, Ry=407 mm, and ky=0.1265 and is decentered. by -2 mm in x and 227 mm in y. The mirrors have an aspect ratio of approximately 4:1. The surface error fabrication tolerances are less than 63.3 nm RMS figure error and less than 10 nm RMS microroughness. The mirrors are attached to the instrument bench via a semi-kinematic, integral flexure mount. We describe mirror design, diamond machining, the results of figure testing using computer-generated holograms, and imaging and scattered light modeling and performance.

Ohl, Raymond G.↗

Neural-net Processed Electronic Holography for Rotating Machines

This report presents the results of an R&D effort to apply neural-net processed electronic holography to NDE of rotors. Electronic holography was used to generate characteristic patterns or mode shapes of vibrating rotors and rotor components. Artificial neural networks were trained to identify damage-induced changes in the characteristic patterns. The development and optimization of a neural-net training method were the most significant contributions of this work, and the training method and its optimization are discussed in detail. A second positive result was the assembly and testing of a fiber-optic holocamera. A major disappointment was the inadequacy of the high-speed-holography hardware selected for this effort, but the use of scaled holograms to match the low effective resolution of an image intensifier was one interesting attempt to compensate. This report also discusses in some detail the physics and environmental requirements for rotor electronic holography. The major conclusions were that neural-net and electronic-holography inspections of stationary components in the laboratory and the field are quite practical and worthy of continuing development, but that electronic holography of moving rotors is still an expensive high-risk endeavor.

Decker, Arthur J.↗

Optical Testing of Diamond Machined, Aspheric Mirrors for Groundbased, Near-IR Astronomy

The Infrared Multi-Object Spectrometer (IRMOS) is a facility-class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8-2.5 micron) spectrometer and operates at approximately 80 K. The 6061-T651 aluminum bench and mirrors constitute an athermal design. The instrument produces simultaneous spectra at low- to mid-resolving power (R=lambda/delta lambda= 300-3000) of approximately 100 objects in its 2.8 x 2.0 arcmin field. We describe ambient and cryogenic optical testing of the IRMOS mirrors across a broad range in spatial frequency (figure error, mid-frequency error, and microroughness). The mirrors include three rotationally symmetric, off-axis conic sections, one off-axis biconic, and several flat fold mirrors. The symmetric mirrors include convex and concave prolate and oblate ellipsoids. They range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. The biconic mirror is concave and has a 94x76 mm aperture, R(sub x)=377 mm, k(sub x)=0.0778, R(sub y)=407 mm, and k(sub y)=0.1265 and is decentered by -2 mm in X and 227 mm in Y. All of the mirrors have an aspect ratio of approximately 6:1. The surface error fabrication tolerances are less than 10 nm RMS microroughness, 'best effort' for mid-frequency error, and less than 63.3 nm RMS figure error. Ambient temperature (approximately 293 K) testing is performed for each of the three surface error regimes, and figure testing is also performed at approximately 80 K. Operation of the ADE Phaseshift MicroXAM white light interferometer (micro-roughness) and the Bauer Model 200 profilometer (mid-frequency error) is described. Both the sag and conic values of the aspheric mirrors make these tests challenging. Figure testing is performed using a Zygo GPI interferometer, custom computer generated holograms (CGH), and optomechanical alignment fiducials. Cryogenic CGH null testing is discussed in detail. We discuss complications such as the change in prescription with temperature and thermal gradients. Correction for the effect of the dewar window is also covered. We discuss the error budget for the optical test and alignment procedure. Data reduction is accomplished using commercial optical design and data analysis software packages. Results from CGH testing at cryogenic temperatures are encouraging thus far.

Chambers, V. John↗

Spaceflight Holography Investigation in a Virtual Apparatus (SHIVA) Ground Experiments and Concepts for Flight Design

This paper discusses the development and design of an experimental test cell for ground-based testing to provide requirements for the Spaceflight Holography Investigation in a Virtual Apparatus (SHIVA) experiment. Ground-based testing of a hardware breadboard set-up is being conducted at Marshall Space Flight Center in Huntsville, Alabama. SHIVA objectives are to test and validate new solutions of the general equation of motion of a particle in a fluid, including particle-particle interaction, wall effects, motion at higher Reynolds Number, and a motion and dissolution of a crystal moving in a fluid. These objectives will be achieved by recording a large number of holograms of particle motion in the International Space Station (ISS) glove box under controlled conditions, extracting the precise three- dimensional position of all the particles as a function of time, and examining the effects of all parameters on the motion of the particles. This paper will describe the mechanistic approach to enabling the SHIVA experiment to be performed in a ISS glove box in microgravity. Because the particles are very small, surface tension becomes a major consideration in designing the mechanical method to meet the experiments objectives in microgravity, To keep a particle or particles in the center of the test cell long enough to perform and record the experiment and to preclude contribution to particle motion, requires avoiding any initial velocity in particle placement. A Particle Injection Mechanism (PIM) designed for microgravity has been devised and tested to enable SHIVA imaging. Also, a test cell capture mechanism, to secure the test cell during vibration on a specially designed shaker table for the SHIVA experiment will be described. Concepts for flight design are also presented.

Miernik, Janie H.↗

Evolution of Local Microstructures: Spatial Instabilities in Coarsening Clusters

Diffusion-limited capillarity-driven coarsening of precipitates is an important and intensively studied phenomenon. The classic coarsening theory developed by Lifshitz and Syozov and Wagner (LSW theory) is limited to infinitesimally small volume fractions, V(sub nu), therefore neglects all direct interparticle interactions. This work uses modeling and holographic imaging to compare coarsening rates in "high" volume fraction versus low volume fraction microstructures by observing mixed-dimensional droplets (spherical caps on a surface coarsening by two-dimensional diffusion) during ground-based investigations. The method involves filling a cell with selected homogeneous parent phase, and cooling below the consolute temperature to the isopycnic temperature in the two-phase region of a monotectic system. A microgravity holographic experiment is required for three-dimensional observations to minimize sedimentation during long-term coarsening. Determination of sizes and positions of the many droplets in the holographic images requires automation. We have developed software for automated data analysis, and demonstrated good agreement between regenerated maps and scaled photographs of the original holograms for mixed dimensional coarsening. The results of these experiments were presented in a formal microgravity Science Concept Review (SCR) on December 18, 2000.

Source record↗

Spaceflight Holography Investigation in a Virtual Apparatus

The movement of a particle in a fluid is one of the most fundamental processes in physics and plays an important role in materials science. For example, the physics of crystal growth from a nucleation site in solution can be dominated by movement of the solution over the crystal surface. Gravity usually dominates the equations of motion, but in microgravity other terms can dominate, making the equation much more complex. Until recently, the equations were solved only by numerical methods and/or by neglecting terms. During this study, we discovered an exact solution to the equations, which shows that the usually neglected terms become extremely important in microgravity. We also developed diagnostic recording methods using holography to save all of the particle field data, allowing the experiment to essentially be transferred from space back to earth in what we call the virtual apparatus . We will record holograms of particle distributions in motion in microgravity and bring them back to earth for analysis, allowing the study of the full three-dimensional motion of sets of particles, allowing us to test the new analytical solutions. The experiment will also provide accurate measurements of the quasi-steady acceleration of the space platform and other interesting microgravity and g-jitter effects. This program will produce the flight definition for an experiment in the microgravity environment of space to validate the theoretical model. We will design an experiment with the help of the theoretical model that is optimized for testing the model, measuring g, g-jitter, and other microgravity phenomena.

Source record↗

Interferometric Tomographic Measurement of an Instataneous Flow Field Under Adverse Environments

Measurement of an instantaneous flow field by interferometric tomography, that is, reconstruction of a three-dimensional refractive-index field from multi-directional projection data, has been conducted. In order to simulate the expected experimental arrangement at a wind tunnel, reconstructions are made from a restricted view angle less than 40 degrees and incomplete projections. In addition, appreciable ambient air and experimental setup disturbances are present. A new phase-stepping technique, based on a generalized phase-stepping approach of a four-bucket model, is applied for expeditious and accurate phase information extraction from projection interferograms under the harsh environments. Phase errors caused by the various disturbances, which can include ambient refractive-index change, optical component disturbance, hologram repositioning error, etc., are partially compensated with a linear corrective model. A new computational tomographic technique based on a series expansion approach was also utilized to efficiently deal with arbitrary boundary shapes and the continuous flow fields in reconstruction. The results of the preliminary investigation are encouraging; however, the technique needs to be further developed in the future through refinement of the approaches reported here and through hybridization with previously developed techniques. Keywords: interferometry, tomography, phase stepping

Yu, En-Xi↗

Optical Metrology for the Segmented Optics on the Constellation-X Spectroscopy X-Ray Telescope

We present the metrology requirements and metrology implementation necessary to prove out the reflector technology for the Constellation X(C-X) spectroscopy X-ray telescope (SXT). This segmented, 1.6m diameter highly nested Wolter-1 telescope presents many metrology and alignment challenges. In particular, these mirrors have a stringent imaging error budget as compared to their intrinsic stiffness; This is required for Constellation-X to have sufficient effective area with the weight requirement. This has implications for the metrology that can be used. A variety of contract and noncontact optical profiling and interferometric methods are combined to test the formed glass substrates before replication and the replicated reflector segments.The reflectors are tested both stand-alone and in-situ in an alignment tower.Some of these methods have not been used on prior X-ray telescopes and some are feasible only because of the segmented approach used on the SXT. Methods discussed include high precision coordinate measurement machines using very low force or optical probe axial interferometric profiling azimuthal circularity profiling and use of advanced null optics such as conical computer generated hologram (CGHs).

Content, David↗

Limitation of Liquid Crystal on Silicon Spatial Light Modular for Holographic Three-dimensional Displays

In a 3-D display system based on an opto-electronic reconstruction of a digitally recorded hologram, the field of view of such a system is limited by the spatial resolution of the liquid crystal on silicon (LCOS) spatial light modular (SLM) used to perform the opto-electronic reconstruction. In this article, the special resolution limitation of LCOS SLM associated with the fringe field effect and interpixel coupling is determined by the liquid crystal detector simulation and the Finite Difference Time Domain (FDTD) simulation. The diffraction efficiency loss associated with the imperfection in the phase profile is studied with an example of opto-electronic reconstruction of an amplitude object. A high spatial resolution LCOS SLM with a wide reconstruction angle is proposed.

Wang, Xinghua↗