Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Speed Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Initial evaluation of commercially available InGaAsP DFB laser diodes for use in high-speed digital fiber optic transceivers

NASA has been pursuing the development of high-speed fiber-optic transceivers for use in a number of space data system applications. Current efforts are directed toward a high-performance all-integrated-circuit transceiver operating up to the 3-5 Gb/s range. Details of the evaluation and selection of candidate high-speed optical sources to be used in the space-qualified high-performance transceiver are presented. Data on the performance of commercially available DFB (distributed feedback) lasers are presented, and their performance relative to each other and to their structural design with regard to their use in high-performance fiber-optic transceivers is discussed. The DFB lasers were obtained from seven commercial manufacturers. The data taken on each laser included threshold current, differential quantum efficiency, CW side mode suppression radio, wavelength temperature coefficient, threshold temperature coefficient, natural linewidth, and far field pattern. It was found that laser diodes with buried heterostructures and first-order gratings had, in general, the best CW operating characteristics. The modulated characteristics of the DFB laser diodes are emphasized. Modulated linewidth, modulated side mode suppression ratio, and frequency response are discussed.

Cook, Anthony L.↗

Laser doppler velocimeter system for subsonic jet mixer nozzle testing at the NASA Lewis Aeroacoustic Propulsion Lab

A laser Doppler velocimeter (LDV) system developed for the Aeroacoustic Propulsion Laboratory (APL) at the NASA Lewis Research Center is described. This system was developed to acquire detailed flow field data which could be used to quantify the effectiveness of internal exhaust gas mixers (IEGM's) and to verify and calibrate computational codes. The LDV was used as an orthogonal, three component system to measure the flow field downstream of the exit of a series of IEGM's and a reference axisymmetric splitter configuration. The LDV system was also used as a one component system to measure the internal axial flow within the nozzle tailpipe downstream of the mixers. These IEGM's were designed for low-bypass ratio turbofan engines. The data were obtained at a simulated low flight speed, high-power operating condition. The optical, seeding, and data acquisition systems of the LDV are described in detail. Sample flow field measurements are provided to illustrate the capabilities of the system at the time of this test, which represented the first use of LDV at the APL. A discussion of planned improvements to the LDV is also included.

Podboy, Gary G.↗

The design of a turboshaft speed governor using modern control techniques

The objectives of this program were: to verify the model of off schedule compressor variable geometry in the T700 turboshaft engine nonlinear model; to evaluate the use of the pseudo-random binary noise (PRBN) technique for obtaining engine frequency response data; and to design a high performance power turbine speed governor using modern control methods. Reduction of T700 engine test data generated at NASA-Lewis indicated that the off schedule variable geometry effects were accurate as modeled. Analysis also showed that the PRBN technique combined with the maximum likelihood model identification method produced a Bode frequency response that was as accurate as the response obtained from standard sinewave testing methods. The frequency response verified the accuracy of linear models consisting of engine partial derivatives and used for design. A power turbine governor was designed using the Linear Quadratic Regulator (LQR) method of full state feedback control. A Kalman filter observer was used to estimate helicopter main rotor blade velocity. Compared to the baseline T700 power turbine speed governor, the LQR governor reduced droop up to 25 percent for a 490 shaft horsepower transient in 0.1 sec simulating a wind gust, and up to 85 percent for a 700 shaft horsepower transient in 0.5 sec simulating a large collective pitch angle transient.

Delosreyes, G.↗

TPSAS-NF1676L-32867-DND

During the summer of 2019, a Fokker F28 MK1000 aircraft was crash tested at the Landing and Impact Research Facility (LandIR) at NASA Langley Research Center (LaRC). The test, which was conducted in cooperation with the FAA Technical Center and the FAA Civil Aeromedical Institute (CAMI), had multiple objectives. The first objective was to obtain data for aircraft undergoing a combined vertical plus horizontal impact condition, and then compare results to aircraft sections under vertical loading only. The second was to evaluate Anthropomorphic Test Devices (ATDs, a.k.a. crash test dummies) of various sizes and positions for the determination of occupant injury. The third was to evaluate new and novel experimental ATDs including a larger Hybrid III, the Test Device for Human Occupant Restraint (THOR), and the Warrior Injury Assessment Manikin (WIAMan). Finally, the generated data was used to calibrate and validate computer simulation efforts. On-board data acquisition systems (DAS) captured loading on the airframe and the 24 on-board occupants while multiple high-speed cameras captured the motion. The port side of the airframe was painted with a stochastic monochromatic speckle pattern to allow for the collection of high-speed airframe deformation digital image correlation data. Airframe and occupant responses from each of the tests will be presented, and airframe and restraint performance will be discussed.

Justin Littell↗

L-PBF High-Throughput Data Pipeline Approach for Multi-modal Integration

Abstract Metal-based additive manufacturing requires active monitoring solutions for assessing part quality. Multiple sensors and data streams, however, generate large heterogeneous data sets that are impractical for manual assessment and characterization. In this work, an automated pipeline is developed that enables feature extraction from high-speed camera video and multi-modal data analysis. The framework removes the need for manual assessment through the utilization of deep learning techniques and training models in a weakly supervised paradigm. We demonstrate this pipeline’s capability over 700,000 high-speed camera frames. The pipeline successfully extracts melt pool and spatter geometries and links them to corresponding pyrometry, radiography, and processparameter information. 715 individual prints are examined to reveal melt pool areas that exceeds 0.07 mm 2 and pyrometry signal over a threshold (375 pyrometry units) were more likely to have defects. These automated processes enable massive throughput of characterization techniques.

36 MATERIALS SCIENCE↗

MIDAS, prototype Multivariate Interactive Digital Analysis System, phase 1. Volume 1: System description

The MIDAS System is described as a third-generation fast multispectral recognition system able to keep pace with the large quantity and high rates of data acquisition from present and projected sensors. A principal objective of the MIDAS program is to provide a system well interfaced with the human operator and thus to obtain large overall reductions in turnaround time and significant gains in throughput. The hardware and software are described. The system contains a mini-computer to control the various high-speed processing elements in the data path, and a classifier which implements an all-digital prototype multivariate-Gaussian maximum likelihood decision algorithm operating at 200,000 pixels/sec. Sufficient hardware was developed to perform signature extraction from computer-compatible tapes, compute classifier coefficients, control the classifier operation, and diagnose operation.

Kriegler, F. J.↗

Pressure-Sensitive Paints Advance Rotorcraft Design Testing

The rotors of certain helicopters can spin at speeds as high as 500 revolutions per minute. As the blades slice through the air, they flex, moving into the wind and back out, experiencing pressure changes on the order of thousands of times a second and even higher. All of this makes acquiring a true understanding of rotorcraft aerodynamics a difficult task. A traditional means of acquiring aerodynamic data is to conduct wind tunnel tests using a vehicle model outfitted with pressure taps and other sensors. These sensors add significant costs to wind tunnel testing while only providing measurements at discrete locations on the model's surface. In addition, standard sensor solutions do not work for pulling data from a rotor in motion. "Typical static pressure instrumentation can't handle that," explains Neal Watkins, electronics engineer in Langley Research Center s Advanced Sensing and Optical Measurement Branch. "There are dynamic pressure taps, but your costs go up by a factor of five to ten if you use those. In addition, recovery of the pressure tap readings is accomplished through slip rings, which allow only a limited amount of sensors and can require significant maintenance throughout a typical rotor test." One alternative to sensor-based wind tunnel testing is pressure sensitive paint (PSP). A coating of a specialized paint containing luminescent material is applied to the model. When exposed to an LED or laser light source, the material glows. The glowing material tends to be reactive to oxygen, explains Watkins, which causes the glow to diminish. The more oxygen that is present (or the more air present, since oxygen exists in a fixed proportion in air), the less the painted surface glows. Imaged with a camera, the areas experiencing greater air pressure show up darker than areas of less pressure. "The paint allows for a global pressure map as opposed to specific points," says Watkins. With PSP, each pixel recorded by the camera becomes an optical pressure tap. "Instead of having 100 or 200 pressure taps, you can have in theory several million, up to whatever the resolution of your camera is." Watkins explains that typical wind tunnel testing requires two models: one with very little instrumentation, and a pressure model with a significant amount of sensors applied. "If you can make all of your measurements on one model with PSP, you've decreased your model costs by at least a factor of two and preferably your testing costs by about that much," he says. PSP technology has been around for almost 20 years, but a PSP solution for gathering instantaneous dynamic pressure data from surfaces moving at high speeds, such as rotor blades, was not available until a NASA partnership led to a game-changing innovation.

Source record↗

Locally adaptive vector quantization: Data compression with feature preservation

A study of a locally adaptive vector quantization (LAVQ) algorithm for data compression is presented. This algorithm provides high-speed one-pass compression and is fully adaptable to any data source and does not require a priori knowledge of the source statistics. Therefore, LAVQ is a universal data compression algorithm. The basic algorithm and several modifications to improve performance are discussed. These modifications are nonlinear quantization, coarse quantization of the codebook, and lossless compression of the output. Performance of LAVQ on various images using irreversible (lossy) coding is comparable to that of the Linde-Buzo-Gray algorithm, but LAVQ has a much higher speed; thus this algorithm has potential for real-time video compression. Unlike most other image compression algorithms, LAVQ preserves fine detail in images. LAVQ's performance as a lossless data compression algorithm is comparable to that of Lempel-Ziv-based algorithms, but LAVQ uses far less memory during the coding process.

Cheung, K. M.↗

MIDAS, prototype Multivariate Interactive Digital Analysis System, phase 1. Volume 3: Wiring diagrams

The Midas System is a third-generation, fast, multispectral recognition system able to keep pace with the large quantity and high rates of data acquisition from present and projected sensors. A principal objective of the MIDAS Program is to provide a system well interfaced with the human operator and thus to obtain large overall reductions in turn-around time and significant gains in throughput. The hardware and software generated in Phase I of the overall program are described. The system contains a mini-computer to control the various high-speed processing elements in the data path and a classifier which implements an all-digital prototype multivariate-Gaussian maximum likelihood decision algorithm operating at 2 x 100,000 pixels/sec. Sufficient hardware was developed to perform signature extraction from computer-compatible tapes, compute classifier coefficients, control the classifier operation, and diagnose operation. The MIDAS construction and wiring diagrams are given.

Kriegler, F. J.↗

MIDAS, prototype Multivariate Interactive Digital Analysis System, Phase 1. Volume 2: Diagnostic system

The MIDAS System is a third-generation, fast, multispectral recognition system able to keep pace with the large quantity and high rates of data acquisition from present and projected sensors. A principal objective of the MIDAS Program is to provide a system well interfaced with the human operator and thus to obtain large overall reductions in turn-around time and significant gains in throughout. The hardware and software generated in Phase I of the over-all program are described. The system contains a mini-computer to control the various high-speed processing elements in the data path and a classifier which implements an all-digital prototype multivariate-Gaussian maximum likelihood decision algorithm operating 2 x 105 pixels/sec. Sufficient hardware was developed to perform signature extraction from computer-compatible tapes, compute classifier coefficients, control the classifier operation, and diagnose operation. Diagnostic programs used to test MIDAS' operations are presented.

Kriegler, F. J.↗

Diode laser absorption sensors for gas-dynamic and combustion flows

Recent advances in room-temperature, near-IR and visible diode laser sources for tele-communication, high-speed computer networks, and optical data storage applications are enabling a new generation of gas-dynamic and combustion-flow sensors based on laser absorption spectroscopy. In addition to conventional species concentration and density measurements, spectroscopic techniques for temperature, velocity, pressure and mass flux have been demonstrated in laboratory, industrial and technical flows. Combined with fibreoptic distribution networks and ultrasensitive detection strategies, compact and portable sensors are now appearing for a variety of applications. In many cases, the superior spectroscopic quality of the new laser sources compared with earlier cryogenic, mid-IR devices is allowing increased sensitivity of trace species measurements, high-precision spectroscopy of major gas constituents, and stable, autonomous measurement systems. The purpose of this article is to review recent progress in this field and suggest likely directions for future research and development. The various laser-source technologies are briefly reviewed as they relate to sensor applications. Basic theory for laser absorption measurements of gas-dynamic properties is reviewed and special detection strategies for the weak near-IR and visible absorption spectra are described. Typical sensor configurations are described and compared for various application scenarios, ranging from laboratory research to automated field and airborne packages. Recent applications of gas-dynamic sensors for air flows and fluxes of trace atmospheric species are presented. Applications of gas-dynamic and combustion sensors to research and development of high-speed flows aeropropulsion engines, and combustion emissions monitoring are presented in detail, along with emerging flow control systems based on these new sensors. Finally, technology in nonlinear frequency conversion, UV laser materials, room-temperature mid-IR materials and broadly tunable multisection devices is reviewed to suggest new sensor possibilities.

Non-NASA Center↗

The modern rotor aerodynamic limits survey: A report and data survey

The first phase of the Modern Technology Rotor Program, the Modern Rotor Aerodynamic Limits Survey, was a flight test conducted by the United States Army Aviation Engineering Flight Activity for NASA Ames Research Center. The test was performed using a United States Army UH-60A Black Hawk aircraft and the United States Air Force HH-60A Night Hawk instrumented main-rotor blade. The primary purpose of this test was to gather high-speed, steady-state, and maneuvering data suitable for correlation purposes with analytical prediction tools. All aspects of the data base, flight-test instrumentation, and test procedures are presented and analyzed. Because of the high volume of data, only select data points are presented. However, access to the entire data set is available upon request.

Cross, J.↗

MIDAS, prototype Multivariate Interactive Digital Analysis System for large area earth resources surveys. Volume 1: System description

A third-generation, fast, low cost, multispectral recognition system (MIDAS) able to keep pace with the large quantity and high rates of data acquisition from large regions with present and projected sensots is described. The program can process a complete ERTS frame in forty seconds and provide a color map of sixteen constituent categories in a few minutes. A principle objective of the MIDAS program is to provide a system well interfaced with the human operator and thus to obtain large overall reductions in turn-around time and significant gains in throughput. The hardware and software generated in the overall program is described. The system contains a midi-computer to control the various high speed processing elements in the data path, a preprocessor to condition data, and a classifier which implements an all digital prototype multivariate Gaussian maximum likelihood or a Bayesian decision algorithm. Sufficient software was developed to perform signature extraction, control the preprocessor, compute classifier coefficients, control the classifier operation, operate the color display and printer, and diagnose operation.

Christenson, D.↗

Optical Instrumentation for Temperature and Velocity Measurements in Rig Turbines

Non-intrusive optical measurement techniques have been examined in the context of developing robust instruments which can routinely yield data of engineering utility in high speed turbomachinery test rigs. The engineering requirements of such a measurement are presented. Of particular interest were approaches that provide both velocity and state-variable information in order to be able to completely characterize transonic flowfields. Consideration of all of the requirements lead to the selection of particle image velocimetry (PIV) for the approach to velocity measurement while laser induced fluorescence of oxygen (O2 LIF) appeared to offer the most promise for gas temperature measurement. A PIV system was developed and demonstrated on a transonic turbine stage in the MIT blowdown turbine facility. A comprehensive data set has been taken at one flow condition. Extensive calibration established the absolute accuracy of the velocity measurements to be 3-5 %. The O2 LIF proved less successful. Although accurate for low speed flows, vibrational freezing of O2 prevented useful measurements in the transonic, 300-600 K operating range of interest here.

Ceyhan, I.↗

Results of aerodynamic heat transfer tests of a 0.0175-scale model of the Rockwell International Space Shuttle Orbiter 139 (model number 22-0) in the NASA/Ames 3.5-foot hypersonic wind tunnel (test OH6)

The results of a hypersonic wind tunnel test program conducted using a 0.0175 scale thin-skin thermocouple model of the Space Shuttle Orbiter to obtain aerodynamic heat transfer data on the Orbiter under simulated reentry conditions were presented. The test program was conducted at a Mach number of 7.3 and a freestream Reynolds number ranging between 1.0 and 6.0 million/foot. The model was tested for angles of attack ranging between 10 deg and 30 deg and a sideslip angle of 0 deg. The model was constructed of 15-5 PH stainless steel with the instrumented areas machined to a nominal skin thickness of 0.030 in. The model instrumentation consisted of 288 iron-constantan thermocouples spot welded to the skin inner surface, but only 75 of these were used in this test program. A high-speed, analog-to-digital data acquisition system was used to record data on magnetic tape.

Dye, W. H.↗

JANUS: Resilient and Adaptive Data Transmission for Enabling Timely and Efficient Cross-Facility Scientific Workflows

In modern science, the growing complexity of large-scale scientific projects has led to an increasing reliance on cross-facility scientific workflows, where resources and expertise from multiple institutions and geographic locations are leveraged to accelerate scientific discovery. These workflows often require transmitting huge amounts of scientific data through wide-area networks. Although high-speed networks like ESnet and transfer services such as Globus have improved data mobility, several challenges remain. The sheer volume of data can overwhelm network bandwidth, widely used transport protocols such as TCP suffer from inefficiencies due to retransmissions triggered by packet loss, and existing fault-tolerance mechanisms like erasure coding introduce substantial overhead. In this paper, we propose Janus, a resilient and adaptable data transmission approach designed for cross-facility scientific workflows. Unlike traditional TCP-based methods, Janus leverages UDP, integrates erasure coding for fault tolerance, and combines it with error-bounded lossy compression to reduce overhead. This novel design allows users to balance data transmission time and accuracy, optimizing transfer performance based on specific scientific requirements. Additionally, Janus dynamically adjusts erasure coding parameters in response to real-time network conditions, ensuring efficient data transfers even in fluctuating environments. We develop optimization models for determining ideal configurations and implement adaptive data transfer protocols to enhance reliability. Through extensive simulations and real-network experiments, we demonstrate that Janus significantly improves transfer efficiency while maintaining data fidelity.

Esaulov, Vladislav [Georgia State University, Atla↗

Transition research in low-disturbance high-speed wind tunnels

The technical requirements and test data from the Mach 3.5 Pilot Low-Disturbance Tunnel are presented. This unique facility provides a test region with essentially zero-acoustic noise and simulates, for the first time, the low-disturbance conditions of atmospheric flight. Applications to the test results of linear stability theory with the e exp N method indicate that transition locations for both simple and complex flows are well predicted by using N of about 9 to 11.

Beckwith, I. E.↗