Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Caborane beam from ITEP Bernas ion source for semiconductor implanters

A joint research and development of steady state intense boron ion sources for hundreds of electron-volt ion implanters has been in progress for the past 5 years. The difficulties of extraction and transportation of low energy boron beams can be solved by implanting clusters of boron atoms. In Institute for Theoretical and Experimental Physics (ITEP) the Bernas ion source successfully generated the beam of decaborane ions. The carborane (C{sub 2}B{sub 10}H{sub 12}) ion beam is more attractive material due to its better thermal stability. The results of carborane ion beam generation are presented. The result of the beam implantation into the silicon wafer is presented as well.

43 PARTICLE ACCELERATORS↗

Size saturation in low energy ion beam synthesized nanoparticles in silica glass: 50 keV Ag{sup -} ions implantation, a case study

Fluence-dependent formation of Ag nanoparticles (NPs) in silica glass by 50 keV Ag{sup -} ions implantation has been studied. Samples implanted with fluences of 2x10{sup 16} ions cm{sup -2} and above are found to show an absorption band at around 410 nm, corresponding to the surface plasmon resonance (SPR) of the Ag NPs in silica glass. An increase in SPR peak intensity with increase in fluence has been observed up to a fluence of 7x10{sup 16} ions cm{sup -2} (F7), after which the absorption intensity shows a saturation. Simulations of the optical absorption spectra also indicated an increase in the absorption intensity and hence the size of the NPs with increase in fluence up to F7, beyond which NP size is seen to saturate. The saturation of fluence and the SPR intensity (or NP size) have been explained as coming due to a break up of larger Ag NPs formed near the surface by displacement spikes induced by subsequently incident Ag ions against their regrowth from the movement of Ag atoms toward the surface and their sputtering loss. Further, we have compared our observations with the earlier data on saturation of fluence and size of NPs in cases of Au and Zn, and concluded that the saturation of both fluence and NP size are general phenomena for low energy high fluence metal ion implantation.

36 MATERIALS SCIENCE↗

Structural and Optical Properties Studies Of Ar{sup 2+} Ion Implanted Mn Deposited GaAs

Mn thin film deposited GaAs samples were implanted with 250 keV Ar{sup +2} ions for various fluences 5x10{sup 15}, 1x10{sup 16} and 5x10{sup 16} ions cm{sup -2}. Optical and structural properties of the samples have been investigated by using ultraviolet spectroscopy and X-ray diffraction techniques. Optical absorbance of the implanted samples was found to decrease with increase in argon ion fluence. XRD spectra of the samples implanted for ion fluences 5x10{sup 15} and 1x10{sup 16} showed the formation of (GaMn)As at 2{theta} value of 65.34 deg. The XRD spectrum of sample 1x10{sup 16} cm{sup -2} annealed at 450 deg. C showed the formation of magnetic phases.

36 MATERIALS SCIENCE↗

Microwave Annealing of Ion Implanted 4H-SiC

Ultra-fast high-temperature microwave annealing at temperatures as high as 2050 deg. C for 30 s has been performed on phosphorus ion-implanted 4H-SiC for phosphorus doping concentrations in the range 5x10{sup 19} cm{sup -3}-8x10{sup 20} cm{sup -3}. For comparison, inductive heating furnace anneals were performed at 1800 deg. C-1950 deg. C for 5 min. Electrical resistivity of the P{sup +}-implanted samples decreased with increasing annealing temperature reaching a minimum value of 6.8x10{sup -4} {Omega}cm for 2050 deg. C/30 s microwave annealing and a slightly higher value for 1950 deg. C/5 min inductive heating furnace annealing. X-ray rocking curve measurements showed that the microwave annealing not only removed the lattice damage introduced by the ion-implantation process, but also the defects present in the original virgin sample as well.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Helium implantation on gettering and electrical properties of 4H-SiC epilayers

This paper tests the gettering ability of sites created by He implantation in 4H-SiC while heating the sample or not, and their impact on carrier lifetime. The spatial distribution of implantation-induced defects (cavities, stacking faults and dislocations) is studied by transmission electron microscopy (TEM) and is compared to gold profiles performed by Rutherford Backscattering (RBS) in samples intentionally contaminated with gold. Minority carrier lifetimes are also measured with a specific set-up based on microwave photoconductivity decay ({mu}-PCD). Though gold atoms do not seem to be efficiently trapped by cavities, the presence of dislocations is of major importance to monitor gold diffusion. Indeed, they can double both its level and its diffusion length in the bulk. Gold is assumed to diffuse faster along dislocation cores. Besides, the implantation-related defects are found to improve the carrier lifetime in the material, but the role of He{sup 2+} left in cavities remains to be investigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simultaneous Sterilization With Surface Modification Of Plastic Bottle By Plasma-Based Ion Implantation

Dry sterilization of polymeric material is developed. The technique utilizes the plasma-based ion implantation which is same as for surface modification of polymers. Experimental data for sterilization are obtained by using spores of Bacillus subtilis as samples. On the other hand we previously showed that the surface modification enhanced the gas barrier characteristics of plastic bottles. Comparing the implantation conditions for the sterilization experiment with those for the surface modification, we find that both sterilization and surface modification are simultaneously performed in a certain range of implantation conditions. This implies that the present bottling system for plastic vessels will be simplified and streamlined by excluding the toxic peroxide water that has been used in the traditional sterilization processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristics of ZnO Wafers Implanted with 60 keV Sn{sup +} Ions at Room Temperature and at 110 K

ZnO wafers implanted with 60 keV Sn{sup +} ions at room temperature (RT) and at 110 K are investigated by means of X-ray diffraction (XRD) and photoluminescence (PL) techniques. The effect of implantation temperature is evident in the XRD and PL data. A yellow-orange (YO) band near 600 nm appears in the PL spectra of the ZnO wafers implanted to the doses of 4x10{sup 14} and 8x10{sup 14} ions/cm{sup 2} at RT. The intensity of this band increases and the peak position blue-shifts after illumination of the samples with the 325 nm line of a He-Cd laser. The PL data suggests that the CB (conduction band){yields}V{sub O}{sup +} and Zn{sub i}{sup +{yields}}V{sub Zn}{sup -} transitions contribute to the photoemission of the YO band.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Medium Current Ion Implanter ''IMPHEAT'' for SiC

High productivity medium current ion implanter 'IMPHEAT' was developed for a commercial silicon carbide (SiC) device production. The beamline concept of IMPHEAT is the same as Nissin's ion implanter EXCEED 9600A for silicon device manufacturing. To meet the implantation process for SiC device fabrication, a new type ion source that can produce aluminum (Al) ion beam and a high temperature platen have been developed and installed. The maximum beam currents are 1 mA of Al{sup +}, 400 e{mu}A of Al{sup 2+} and 10 e{mu}A of Al{sup 3+}, and the time variation for these beam currents is less than {+-}10% per hour. The high-temperature platen can handle from 2 to 6 inch wafers. The wafer temperature reaches 600 deg. C for a 6 inch wafer and 500 deg. C for smaller size wafers by using the wafer holder. We have carried out the qualification test and the performance was confirmed as enough for commercial production of SiC devices.

43 PARTICLE ACCELERATORS↗

Use of Xenon Difluoride to Clean Hazardous By-Products in Ion Implanter Source Housings, Turbo Pumps, and Fore-Lines

This paper describes the use of xenon difluoride to clean deposits in the source housing, source turbo pump, and source turbo pump fore-line of ion implanters. Xenon difluoride has previously been shown to be effective in increasing the lifetime of the ion source{sup 1,2} and this paper presents an extension of the technology to other areas within the tool. Process by-products that are deposited in the source housing, turbo pump, and turbo pump fore-line can not only pose productivity issues, in the case of coatings on insulators, but can also be flammable and toxic in the case of deposits formed within the turbo pump and fore-line. The results presented in this paper detail the initial successful examples of using xenon difluoride to clean these deposits.ATMI has shown that xenon difluoride is capable of cleaning an insulator in an ion implanter. Typically during use an insulator will become increasingly coated with deposits that could lead to productivity problems. By introducing xenon difluoride into the source housing the insulator residues were effectively cleaned in-situ, thereby extending the maintenance interval and resulting in significant consumable savings.Similar deposits that form in the turbo pump and fore-line could not only lead to production problems due to turbo pump failure or fore-line build-up, but pose significant health risks during the ex-situ cleaning process. Through internal testing ATMI has shown that xenon difluoride is able to clean phosphorus and germanium deposits located within a turbo pump. Additionally, testing has demonstrated that the turbo pump fore-line can be cleaned in-situ without the need to remove these components, thereby virtually eliminating the possibility of fires. The cleaning reaction progress and by-products were monitored using FTIR spectrometry and thermocouples.In order to efficiently clean the source housing, turbo pump, and turbo pump fore-line xenon difluoride delivery must be optimized. This paper also details a hardware concept that maximizes xenon difluoride delivery and allows the clean to be done in a way that is viable for production ion implanters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Oxygen-Atom Defects In 6H Silicon Carbide Implanted Using 24- MeV O{sup 3+} Ions Measured Using Three-Dimensional Positron Annihilation Spectroscopy System (3DPASS)

Three dimensional electron-positron (e{sup -}-e{sup +}) momentum distributions were measured for single crystal 6H silicon carbide (SiC); both virgin and having implanted oxygen-atom defects. 6H SiC samples were irradiated by 24- MeV O{sup 3+} ions at 20 particle-nanoamps at the Sandia National Laboratory's Ion Beam Facility. O{sup 3+} ions were implanted 10.8 {mu}m deep normal to the (0001) face of one side of the SiC samples. During positron annihilation measurements, the opposite face of the 254.0-{mu}m thick SiC samples was exposed to positrons from a {sup 22}Na source. This technique reduced the influence on the momentum measurements of vacancy-type defects resulting from knock-on damage by the O{sup 3+} ions. A three-dimensional positron annihilation spectroscopy system (3DPASS) was used to measure e{sup -}-e{sup +} momentum distributions for virgin and irradiated 6H SiC crystal both before and following annealing. 3DPASS simultaneously measures coincident Doppler-broadening (DBAR) and angular correlation of annihilation radiation (ACAR) spectra. DBAR ratio plots and 2D ACAR spectra are presented. Changes in the momentum anisotropies relative to crystal orientation observed in 2D ACAR spectra for annealed O-implanted SiC agree with the local structure of defect distortion predicted using Surface Integrated Molecular Orbital/Molecular Mechanics (SIMOMM). Oxygen atoms insert between Si and C atoms increasing their separation by 0.9 A forming a Si-O-C bond angle of {approx}150 deg.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stability of Ag nanocrystals synthesized by ultra-low energy ion implantation in SiO{sub 2} matrices

Ultra low energy ion implantation is a promising technique for the wafer-scale fabrication of Silver nanoparticle planar arrays embedded in thermal silica on silicon substrate. The stability versus time of these nanoparticles is studied at ambient conditions on a time scale of months. The plasmonic signature of Ag NPs vanishes several months after implantation for as-implanted samples, while samples annealed at intermediate temperature under N{sub 2} remain stable. XPS and HREM analysis evidence the presence of Silver oxide nanoparticles on aged samples and pure Silver nanoparticles on the annealed ones. This thermal treatment does not modify the size-distribution or position of the particles but is very efficient in stabilizing the metallic particles and to prevent any form of oxidation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Setting up of a low temperature in-situ ion implantation and channeling facility at Kalpakkam

A simple low temperature ion implantation and ion channeling facility has been set up. Low temperatures upto 70 K has been obtained on a goniometer sample holder by connecting to a continuous flow Helium cryostat with a copper braid. Charge integration is carried out with a transmission Faraday cup with 10 mm diameter aperture and four Faraday cups for performing ion implantation and an electron suppressed 1.5 mm aperture with a TEM grid of 60% beam transmission for ion beam analysis. Typical low temperature ion implantation and channeling experiments have been carried out. Stabilization at intermediate temperatures by controlling the heater at the sample holder and improvement of the achievable lowest temperature by having liquid nitrogen cooled heat shield are in progress.

43 PARTICLE ACCELERATORS↗

Annealing Behavior of Ion-implanted Nitrogen in D9 Steel

Nitrogen isotope N{sup 15} was implanted at the sub-surface of D9 steel. The resonance nuclear reaction analysis was used to probe the implanted nitrogen as a function of depth. The as-implanted D9 sample was isochronally annealed and by observing the broadening of nitrogen depth profile at various annealing junctures, activation energy for nitrogen diffusion in steel was deduced.

36 MATERIALS SCIENCE↗

Evaluation of Carbon Interstitial in C-ion Implanted ZnO Bulk Single Crystals by a Nuclear Reaction Analysis Study: An Origin of Low Resistivity

Nuclear reaction analysis (NRA) of carbon-implanted ZnO bulk single crystals (carbon concentration: 1.5x10{sup 20} cm{sup -3}), in conjunction with the channeling technique, using the {sup 12}C(d,p){sup 13}C and {sup 16}O(d,p){sup 17}O reactions shows the presence of the interstitial carbon (C{sub i}) and the occupancy of substitute sites of oxygen atoms. These results suggest that the variation in resistivity from the order of 10{sup 4} {Omega}cm(for un-implanted samples) to that of 10 {Omega}cm (for as-implanted ones) is attributed to the C{sub i} and/or its complex defects, which would act as a shallow donor in ZnO.

36 MATERIALS SCIENCE↗

Diffusion of co-implanted carbon and boron in silicon and its effect on excess self-interstitials

Diffusion of co-implanted carbon (C) and boron (B) in silicon (Si) and its effect on excess Si self-interstitials (I's) after annealing at 800 and 1000 deg. C were investigated by means of secondary ion mass spectrometry. The experimental results showed that C diffusion was not significant at 800 and 1000 deg. C but later became visible for longer annealing times at 1000 deg. C. B diffusion was reduced by the presence of C when no significant C diffusion was observed, but it was enhanced when C diffusion was observed. These results indicate that all implanted C atoms form immobile CI clusters with excess I in the amount of implanted C and that these CI clusters are stable and trap I to reduce B diffusion. On the contrary, CI clusters are dissolved to emit I for longer annealing times at 1000 deg. C and both B and C diffusion are enhanced. Diffusion simulation based on these models fits the experimental profiles of B and C.

36 MATERIALS SCIENCE↗

Low-temperature, site selective graphitization of SiC via ion implantation and pulsed laser annealing

A technique is presented to selectively graphitize regions of SiC by ion implantation and pulsed laser annealing (PLA). Nanoscale features are patterned over large areas by multi-ion beam lithography and subsequently converted to few-layer graphene via PLA in air. Graphitization occurs only where ions have been implanted and without elevating the temperature of the surrounding substrate. Samples were characterized using Raman spectroscopy, ion scattering/channeling, SEM, and AFM, from which the degree of graphitization was determined to vary with implantation species, damage and dose, laser fluence, and pulsing. Contrasting growth regimes and graphitization mechanisms during PLA are discussed.

36 MATERIALS SCIENCE↗

Ion sources for ion implantation technology (invited)

Ion sources for ion implantation are introduced. The technique is applied not only to large scale integration (LSI) devices but also to flat panel display. For LSI fabrication, ion source scheduled maintenance cycle is most important. For CMOS image sensor devices, metal contamination at implanted wafer is most important. On the other hand, to fabricate miniaturized devices, cluster ion implantation has been proposed to make shallow PN junction. While for power devices such as silicon carbide, aluminum ion is required. For doping processes of LCD fabrication, a large ion source is required. The extraction area is about 150 cm × 10 cm, and the beam uniformity is important as well as the total target beam current.

43 PARTICLE ACCELERATORS↗

Structural defects induced by Fe-ion implantation in TiO{sub 2}

X-ray photoelectron spectroscopy and resonant x-ray emission spectroscopy measurements of pellet and thin film forms of TiO{sub 2} with implanted Fe ions are presented and discussed. The findings indicate that Fe-implantation in a TiO{sub 2} pellet sample induces heterovalent cation substitution (Fe{sup 2+} → Ti{sup 4+}) beneath the surface region. But in thin film samples, the clustering of Fe atoms is primarily detected. In addition to this, significant amounts of secondary phases of Fe{sup 3+} are detected on the surface of all doped samples due to oxygen exposure. These experimental findings are compared with density functional theory calculations of formation energies for different configurations of structural defects in the implanted TiO{sub 2}:Fe system. According to our calculations, the clustering of Fe-atoms in TiO{sub 2}:Fe thin films can be attributed to the formation of combined substitutional and interstitial defects. Further, the differences due to Fe doping in pellet and thin film samples can ultimately be attributed to different surface to volume ratios.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗