The ALS OSMS: Optical Surface Measuring System for high accuracy two-dimensional slope metrology with state-of-the-art x-ray mirrors

We report that to preserve the brightness and coherence of x-rays produced by diffraction-limited-storage-ring (DLSR) and free-electron laser (FEL) light sources, beamline optics must have unprecedented quality. For example, in the case of the most advanced beamlines for the DLSR source under development at the Advanced Light Source (ALS), the ALS-U, we need highly curved x-ray mirrors with surface slope tolerances better than 50-100 nrad (root-mean-square, rms). At the ALS X-Ray Optics Lab (XROL), we are working on the development of a new Optical Surface Measuring System (OSMS) with the required measurement accuracy. The OSMS is capable for the two-dimensional (2D) surface slope metrology over the spatial range from the sub-mm scale to the clear aperture. Usage of different arrangements of the OSMS sensors allows measuring the mirrors in the face-up or side-facing orientation, corresponding to the beamline application. The OSMS translation system and data acquisition software are designed to support multi scan measurement runs optimized for automatic suppression and compensation of instrumental drifts and major angular and spatial systematic errors. Here, we discuss the recent results of the OSMS research and development project. We provide details of the OSMS design and describe results of experimental performance tests of the gantry system. In particular, we show that the system is capable for measurement repeatability with strongly curved mirrors on the level of 20 nrad (rms). The high angular resolution of the OSMS rotational tip-tilt stage is adequate for implementation of instrumental calibration with using the mirror under test as a reference. The achieved measuring accuracy is demonstrated via comparison to metrology with the carefully calibrated Developmental Long Trace Profiler, also available at the XROL.

47 OTHER INSTRUMENTATION↗

Carbon fiber plume sampling for large scale fire tests at Dugway Proving Ground

Carbon fiber sampling instruments were developed: passive collectors made of sticky bridal veil mesh, and active instruments using a light emitting diode (LED) source. These instruments measured the number or number rate of carbon fibers released from carbon/graphite composite material when the material was burned in a 10.7 m (35 ft) dia JP-4 pool fire for approximately 20 minutes. The instruments were placed in an array suspended from a 305 m by 305 m (1000 ft by 1000 ft) Jacob's Ladder net held vertically aloft by balloons and oriented crosswind approximately 140 meters downwind of the pool fire. Three tests were conducted during which released carbon fiber data were acquired. These data were reduced and analyzed to obtain the characteristics of the released fibers including their spatial and size distributions and estimates of the number and total mass of fibers released. The results of the data analyses showed that 2.5 to 3.5 x 10 to the 8th power single carbon fibers were released during the 20 minute burn of 30 to 50 kg mass of initial, unburned carbon fiber material. The mass released as single carbon fibers was estimated to be between 0.1 and 0.2% of the initial, unburned fiber mass.

Chovit, A. R.↗

Star-field identification algorithm

A description of a new star-field identification algorithm that is suitable for implementation on CCD-based imaging cameras is presented. The minimum identifiable star pattern element consists of an oriented star triplet defined by three stars, their celestial coordinates, and their visual magnitudes. The algorithm incorporates tolerance to faulty input data, errors in the reference catalog, and instrument-induced systematic errors.

Scholl, M. S.↗

Microgravity Drill and Anchor System

This work is a method to drill into a rock surface regardless of the gravitational field or orientation. The required weight-on-bit (WOB) is supplied by a self-contained anchoring mechanism. The system includes a rotary percussive coring drill, forming a complete sampling instrument usable by robot or human. This method of in situ sample acquisition using micro - spine anchoring technology enables several NASA mission concepts not currently possible with existing technology, including sampling from consolidated rock on asteroids, providing a bolt network for astronauts visiting a near-Earth asteroid, and sampling from the ceilings or vertical walls of lava tubes and cliff faces on Mars. One of the most fundamental parameters of drilling is the WOB; essentially, the load applied to the bit that allows it to cut, creating a reaction force normal to the surface. In every drilling application, there is a minimum WOB that must be maintained for the system to function properly. In microgravity (asteroids and comets), even a small WOB could not be supported conventionally by the weight of the robot or astronaut. An anchoring mechanism would be needed to resist the reactions, or the robot or astronaut would push themselves off the surface and into space. The ability of the system to anchor itself to a surface creates potential applications that reach beyond use in low gravity. The use of these anchoring mechanisms as end effectors on climbing robots has the potential of vastly expanding the scope of what is considered accessible terrain. Further, because the drill is supported by its own anchor rather than by a robotic arm, the workspace is not constrained by the reach of such an arm. Yet, if the drill is on a robotic arm, it has the benefit of not reflecting the forces of drilling back to the arm s joints. Combining the drill with the anchoring feet will create a highly mobile, highly stable, and highly reliable system. The drilling system s anchor uses hundreds of microspine toes that independently find holes and ledges on a rock to create an anchor. Once the system is anchored, a linear translation mechanism moves the drill axially into the surface while maintaining the proper WOB. The linear translation mechanism is composed of a ball screw and stepper motor that can translate a carriage with high precision and applied load. The carriage slides along rails using self-aligning linear bearings that correct any axial misalignment caused by bending and torsion. The carriage then compresses a series of springs that simultaneously transmit the load to the drill along the bit axis and act as a suspension that compensates for the vibration caused by percussive drilling. The drill is a compacted, modified version of an off-the-shelf rotary percussive drill, which uses a custom carbide-tipped coring bit. By using rotary percussive drilling, the drill time is greatly reduced. The percussive action fractures the rock debris, which is removed during rotation. The final result is a 0.75-in. (.1.9- cm) diameter hole and a preserved 0.5- in. (.1.3-cm) diameter rock core. This work extends microspine technology, making it applicable to astronaut missions to asteroids and a host of robotic sampling concepts. At the time of this reporting, it is the first instrument to be demonstrated using microspine anchors, and is the first self-contained drill/anchor system to be demonstrated that is capable of drilling in inverted configurations and would be capable of drilling in microgravity.

Parness, Aaron↗

Spherical Coordinate Systems for Streamlining Suited Mobility Analysis

When describing human motion, biomechanists generally report joint angles in terms of Euler angle rotation sequences. However, there are known limitations in using this method to describe complex motions such as the shoulder joint during a baseball pitch. Euler angle notation uses a series of three rotations about an axis where each rotation is dependent upon the preceding rotation. As such, the Euler angles need to be regarded as a set to get accurate angle information. Unfortunately, it is often difficult to visualize and understand these complex motion representations. One of our key functions is to help design engineers understand how a human will perform with new designs and all too often traditional use of Euler rotations becomes as much of a hindrance as a help. It is believed that using a spherical coordinate system will allow ABF personnel to more quickly and easily transmit important mobility data to engineers, in a format that is readily understandable and directly translatable to their design efforts. Objectives: The goal of this project is to establish new analysis and visualization techniques to aid in the examination and comprehension of complex motions. Methods: This project consisted of a series of small sub‐projects, meant to validate and verify the method before it was implemented in the ABF's data analysis practices. The first stage was a proof of concept, where a mechanical test rig was built and instrumented with an inclinometer, so that its angle from horizontal was known. The test rig was tracked in 3D using an optical motion capture system, and its position and orientation were reported in both Euler and spherical reference systems. The rig was meant to simulate flexion/extension, transverse rotation and abduction/adduction of the human shoulder, but without the variability inherent in human motion. In the second phase of the project, the ABF estimated the error inherent in a spherical coordinate system, and evaluated how this error would vary within the reference frame. This stage also involved expanding a kinematic model of the shoulder, to include the torso, knees, ankle, elbows, wrists and neck. Part of this update included adding a representation of 'roll' about an axis, for upper arm and lower leg rotations. The third stage of the project involved creating visualization methods to assist in interpreting motion in a spherical frame. This visualization method will be incorporated in a tool to evaluate a database of suited mobility data, which is currently in development.

Benson, Elizabeth↗

Hierarchical Microstructures in CZT

Advanced characterization tools, such as electron backscatter diffraction and transmitted IR microscopy, are being applied to study critical microstructural features and orientation relations in as-grown CZT crystals to aid in understanding the relation between structure and properties in radiation detectors. Even carefully prepared single crystals of CZT contain regions of slight misorientation, Te-particles, and dislocation networks that must be understood for more accurate models of detector response. This paper describes initial research at PNNL into the hierarchy of microstructures observed in CZT grown via the vertical gradient freeze or vertical Bridgman method at PNNL and WSU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New International Program to Asses the Reliability of Emerging Nondestructive Techniques (PARENT)

The Nuclear Regulatory Commission (NRC) established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) to follow on from the successful Program for the Inspection of Nickel alloy Components (PINC). The goal of the PARENT is to conduct a confirmatory assessment of the reliability of nondestructive evaluation (NDE) techniques for detecting and sizing primary water stress corrosion cracks (PWSCC) and applying the lessons learned from PINC to a series of round-robin tests. These open and blind round-robin tests will comprise a new set of typical pressure boundary components including dissimilar metal welds (DMWs) and bottom-mounted instrumentation penetrations. Open round-robin tests will engage research and industry teams worldwide to investigate and demonstrate the reliability of emerging NDE techniques to detect and size flaws with a wide range of lengths, depths, orientations, and locations. Blind round-robin tests will utilize various testing organizations, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from relatively easy to very difficult for detection and sizing. Blind and open round-robin testing started in late 2011 and early 2012, respectively. This paper will present the work scope with reports on progress, NDE methods evaluated, and project timeline for PARENT.

Bottom Mounted Instrumentation↗

Purposes, paradigms and pressure groups: Accountability and sustainability in EU environmental assessment, 1985-2010

Twenty five years since the introduction of the European Union (EU) environmental impact assessment (EIA) Directive in 1985 this paper reflects on the extent to which environmental assessment (EA) processes, over the course of their evolution over the last 25 years in the EU, have provided a platform for enhancing accountability and sustainability. Surprisingly-in the context of legal mandates for EA-there is little reference in the EA literature explicitly to the literature on accountability and the role EA may play in this increasingly important aspect of governance. The paper explores EA implementation principally from an environmentalist perspective and particularly the way in which NGOs and other advocates for the environment in the UK and EU have used the EA legislation as a lever for increasing democratic, corporate and professional accountability of proponents and decision-makers alike. From an a historical analysis, including two historical EIA case studies and two contemporary SEA case studies, it becomes clear that EA has had an important role to play-at the legislative level in providing the requirements for accountability, and at the implementation level as the lever that can be used to hold individuals, organisations and authorities to account for their actions. The relationship with the shift to sustainability is a close one, since sustainable development demands greater public involvement in decision-making and greater accountability of executive decisions to the public. The lessons from this analysis allow the development of a nascent policy-oriented theory regarding EA's role in accountability, which provides a framework for a distinctive new area of EA research and policy analysis. Moreover, an accountability perspective on EA could help re-frame EA for policy makers from being purely an informational and procedural instrument to one which promotes better accountability and sustainability simultaneously. - Highlights: Black-Right-Pointing-Pointer Little attention in the literature to environmental assessment (EA) and accountability. Black-Right-Pointing-Pointer Evolution of EA in the EU influenced by shifting policy paradigms and demands for accountability. Black-Right-Pointing-Pointer EIA and SEA, as formal procedures, can provide platforms for accountability. Black-Right-Pointing-Pointer Four case studies illustrate how NGOs and others have used EA to further accountability. Black-Right-Pointing-Pointer A policy-oriented theory provides a basis for considering future evolution of EA in the EU.

54 ENVIRONMENTAL SCIENCES↗

The Pacific Northwest National Laboratory library of bacterial and archaeal proteomic biodiversity

This dataset deposition announces the submission to public repositories of the PNNL Biodiversity Library, a large collection of global proteomics data for 112 bacterial and archaeal organisms. The data comprises 35,162 tandem mass spectrometry (MS/MS) datasets from ~10 years of research. All data has been searched, annotated and organized in a consistent manner to promote reuse by the community. Protein identifications were cross-referenced with KEGG functional annotations which allows for pathway oriented investigation. We present the data as a freely available community resource. A variety of data re-use options are described for computational modeling, proteomics assay design and bioengineering. Instrument data and analysis files are available at ProteomeXchange via the MassIVE partner repository under the identifiers PXD001860 and MSV000079053.

59 BASIC BIOLOGICAL SCIENCES↗

Note: A scanning electron microscope sample holder for bidirectional characterization of atomic force microscope probe tips

A novel sample holder that enables atomic force microscopy (AFM) tips to be mounted inside a scanning electron microscopy (SEM) for the purpose of characterizing the AFM tips is described. The holder provides quick and easy handling of tips by using a spring clip to hold them in place. The holder can accommodate two tips simultaneously in two perpendicular orientations, allowing both top and side view imaging of the tips by the SEM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom. The PSDs were distributed on a 26 x 26 cm{sup 2} grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm. Each PSD was made of a 1 mm diameter by 3 mm long cylindrical polystyrene scintillating fiber coupled to a clear nonscintillating plastic optical fiber. All of the light signals emitted by the PSDs were read simultaneously with an optical system at a rate of one measurement per second. We characterized the performance of the optical system, the angular dependency of the device, and the perturbation of dose distributions caused by the hundreds of PSDs inserted into the phantom. We also evaluated the capacity of the system to monitor complex multileaf collimator (MLC) sequences such as those encountered in step-and-shoot intensity modulated radiation therapy (IMRT) plans. We compared our results with calculations performed by a treatment planning system and with measurements taken with a 2D ionization chamber array and with a radiochromic film. Results: The detector array that we developed allowed us to measure doses with an average precision of better than 1% for cumulated doses equal to or greater than 6.3 cGy. Our results showed that the dose distributions produced by the 6-MV photon beam are not perturbed (within {+-}1.1%) by the presence of the hundreds of PSDs located into the phantom. The results also showed that the variations in the beam incidences have little effect on the dose response of the device. For all incidences tested, the passing rates of the gamma tests between the 2D-PSDA and the treatment planning system were higher than 97.5% when the standard clinical tolerances of 3% or 3 mm were used. Excellent agreement was obtained between the doses measured and calculated when we used the 2D-PSDA for monitoring a MLC sequence from a step-and-shoot IMRT plan. Conclusions: We demonstrated the feasibility of using a large number of PSDs in a new 2D-PSDA for the dosimetry of MV energy photon beams in radiation therapy. The excellent precision, accuracy, and low angular dependence of the device indicate that such a prototype could potentially be used as a high-accuracy quality assurance tool for IMRT and arc therapy patient plan verification. The homogeneity and water-equivalence of the prototype we built suggest that this technology could be extended to multiple detection planes by arranging the fibers into more complex orientations, opening the possibility for 3D dosimetry with PSDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument pointing system applicability and orbiter stabilization for EVAL missions. Application studies

Related aspect of the Earth Viewing Applications Laboratory (EVAL) shuttle missions were investigated. The applicability of the gimballed Instrument Pointing System (IPS) to EVAL missions by comparing the IPS capabilities with the EVAL requirements was evaluated, and a means of stabilizing the shuttle orbiter attitude in earth viewing orientations for prolonged periods without use of the orbiter gas reaction control system was assessed.

Spector, V. A.↗

Characterization of a one dimensional focusing compound refractive lens using the rotating shearing interferometer technique

A one dimensional (1D) compound refractive lens (CRL) has been characterized using the grating based rotating shearing interferometer technique. The method is based on the calculation of moire fringes orientation to sense wavefront information. The phase shift and the optical aberration introduced by the 1D CRL on an X-ray beam were retrieved from a single moire fringe image. The radius of curvature of the lens at the apex was derived. This physical radius of the CRL, which is also closely related to the focal length of the 1D CRL, was shown to vary with the incident angle of the incoming X-ray beam onto the CRL. The experimental measurement agreed very well with the theoretical expectations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Landsat Data Continuity Mission

The Landsat Data Continuity Mission (LDCM) is currently under development and is on schedule to launch the 8th satellite in the Landsat series in December of 2012. LDCM is a joint project between the National Aeronautics and Space Administration (NASA) and the United States Geological Survey (USGS). NASA is responsible for developing and launching the flight hardware and on-orbit commissioning and USGS is responsible for developing the ground system and operating the system onorbit after commissioning. Key components of the flight hardware are the Operational Land Imager (OLI), nearing completion by Ball Aerospace & Technologies Corp in Boulder, CO, the Thermal Infrared Sensor (TIRS), being built by NASA's Goddard Space Flight Center and the spacecraft, undergoing integration at Orbital Sciences Corp in Gilbert, Arizona. The launch vehicle will be an Atlas-5 with launch services provided by NASA's Kennedy Space Center. Key ground systems elements are the Mission Operations Element, being developed by the Hammers Corporation, and the Collection Activity Planning Element, Ground Network Element, and Data Processing and Archive System, being developed internally by the USGS Earth Resources Observations and Science (EROS) Center. The primary measurement goal of LDCM is to continue the global coverage of moderate spatial resolution imagery providing continuity with the existing Landsat record. The science goal for this imagery is to monitor land use and land cover, particularly as it relates to global climate change. Together the OLI and TIRS instruments on LDCM replace the ETM+ instrument on Landsat-7 with significant enhancements. The OLI is a pushbroom design instrument where the scanning mechanism of the ETM+ is effectively replaced by a long line of detectors. The OLI has 9 spectral bands with similar spatial resolution to ETM+: 7 of them similar to the reflective spectral bands on ETM+ and two new bands. The two new bands cover (1) the shorter wavelength blue part of the spectrum to help with coastal studies and aerosol analyses/atmospheric correction and (2) an atmospheric water absorption band, where the Earth surface is generally not visible, but Cirrus clouds are, to aid in cloud detection and screening. The radiometry of OLI benefits from improved SNR, dynamic range and quantization. OLI is undergoing system testing with a delivery scheduled for Spring 2011. The TIRS is also a pushbroom design and used QWIPS detectors that require cooling to 43K using a cryocooler. It.has two spectral bands, effectively splitting the ETM+ band 6 in half, that can be used as a split window to aid in atmospheric correction. It has nominally 100 m spatial resolution as opposed to the 60 m of Landsat-7 ETM+: TIRS has commenced integration and test, with a delivery to the spacecraft vendor scheduled for Winter 2011-2012. The Orbital spacecraft currently being integrated for LDCM will have improved capabilities for pointing over previous missions. These capabilities will allow the OLI and TIRS instruments to point off-nadir the equivalent of one WRS-2 path to increase the chances of coverage for high priority targets, particularly in the event of natural disasters. Also, the pointing capability will allow the calibration of the OLI using the sun (roughly weekly), the moon (monthly), stars (during commissioning) and the Earth (at 90 deg from normal orientation, a.k.a., side slither) quarterly. The solar calibration will be used for OLI absolute and relative calibration, the moon for trending the stability of the OLI response, the stars will be used for Line of Sight determination and the side slither will be an alternate OLI and relative gain determination methodology. The spacecraft is scheduled to begin integration with the OLI instrument in Summer 2011. The LDCM data processing and archive system (DPAS), located at USGS EROS, generates the products for distribution to users. Like Landsat-7 this includes an image assessment system for characrizing instrument performance and updating calibration parameters. Products will be generated that include the spectral bands from both instruments, terrain corrected and registered to the geoid. Also, like Landsat-7, data products will be distributed at no charge to the user. The current status and plans of the space and ground segments of the LDCM project will be presented along with performance predictions as available. More detailed information on the two instruments is intended to be presented in separate papers.

Markham, Brian↗

Anisotropic Circular Dichroism Signatures of Oriented Thylakoid Membranes and Lamellar Aggregates of LHCII

In photosynthesis research, circular dichroism (CD) spectroscopy is an indispensable tool to probe molecular architecture at virtually all levels of structural complexity. At the molecular level, the chirality of the molecule results in intrinsic CD; pigment-pigment interactions in protein complexes and small aggregates can give rise to excitonic CD bands, while 'psi-type' CD signals originate from large, densely packed chiral aggregates. It has been well established that anisotropic CD (ACD), measured on samples with defined non-random orientation relative to the propagation of the measuring beam, carries specific information on the architecture of molecules or molecular macroassemblies. However, ACD is usually combined with linear dichroism and can be distorted by instrumental imperfections, which given the strong anisotropic nature of photosynthetic membranes and complexes, might be the reason why ACD is rarely studied in photosynthesis research. In this study, we present ACD spectra, corrected for linear dichroism, of isolated intact thylakoid membranes of granal chloroplasts, washed unstacked thylakoid membranes, photosystem II (PSII) membranes (BBY particles), grana patches, and tightly stacked lamellar macroaggregates of the main light-harvesting complex of PSII (LHCII). We show that the ACD spectra of face- and edge-aligned stacked thylakoid membranes and LHCII lamellae exhibit profound differences in their psi-type CD bands. Marked differences are also seen in the excitonic CD of BBY and washed thylakoid membranes. Magnetic CD (MCD) spectra on random and aligned samples, and the largely invariable nature of the MCD spectra, despite dramatic variations in the measured isotropic and anisotropic CD, testify that ACD can be measured without substantial distortions and thus employed to extract detailed information on the (supra)molecular organization of photosynthetic complexes. An example is provided showing the ability of CD data to indicate such an organization, leading to the discovery of a novel crystalline structure in macroaggregates of LHCII.

59 BASIC BIOLOGICAL SCIENCES↗

Modified Quadrupole Ion Trap Mass Spectrometer for Infrared Ion Spectroscopy: Application to Protonated Thiated Uridines

Modifications to a Paul-type quadrupole ion trap mass spectrometer providing optical access to the trapped ion cloud as well as hardware and software for coupling to a table-top IR optical parametric oscillator laser (OPO) are detailed. Critical experimental parameters for infrared multiple photon dissociation (IRMPD) on this instrument are characterized. IRMPD action spectra, collected in the hydrogen-stretching region with this instrument, complemented by spectra in the IR fingerprint region acquired at the FELIX facility, are employed to characterize the structures of the protonated forms of 2-thiouridine, [s{sup 2}Urd+H]{sup +}, and 4-thiouridine, [s{sup 4}Urd+H]{sup +}. The measured spectra are compared with predicted linear IR spectra calculated at the B3LYP/6-311+G(d,p) level of theory to determine the conformers populated in the experiments. This comparison indicates that thiation at the 2- or 4-positions shifts the protonation preference between the 2,4-H tautomer and 4-protonation in opposite directions versus canonical uridine, which displays a roughly equal preference for the 2,4-H tautomer and O4 protonation. As found for canonical uridine, protonation leads to a mixture of conformers exhibiting C2′-endo and C3′-endo sugar puckering with an anti nucleobase orientation being populated for both 2- and 4-thiated uridine. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioisotope Power System Dose Estimation Tool (RPS-DET) User Manual

Radioisotope power systems (RPSs) convert decay heat from radioactive materials to electrical power. The National Aeronautics and Space Administration (NASA) uses RPSs for certain orbiters, landers, rovers, and probes that cannot rely on solar or chemical power. Most of the emitted charged particles in RPS fuels are locally absorbed, and the particles’ kinetic energy is converted into thermal energy as they slow down in the surrounding materials. This heat is subsequently converted into electricity through some form of energy conversion process (e.g., thermoelectric, heat engine, thermionic). While nearly all the charged particles are stopped locally, a non-trivial portion of the emitted neutral particles (neutrons and photons) escape the fuel and are free to interact with surrounding materials. This escaping radiation field can be operationally problematic for certain instruments, materials, electronics, etc., and can cause problems during terrestrial shipping, integration, testing for personnel, instrumentation, etc. Furthermore, the fuel’s emission spectrum evolves over time as the parent isotopes decay away and daughter products accumulate. This changing fuel composition alters characteristics of the ambient radiation field over time, which is further affected by RPS orientation and the surrounding environment. Tools that can rapidly estimate the radiation characteristics of RPSs with various fuel compositions, fuel ages, various RPS orientations, and in/on different spaceflight and planetary scenarios provide researchers with an opportunity to quickly estimate the radiation implications of a given RPS scenario. The RPS dose estimation tool (RPS-DET) provides engineers, scientists and analysts who are not trained in the art of particle transport software with a solution for quickly building, simulating, and analyzing the radiation impacts of various RPS designs in relevant spaceflight and terrestrial environments.

30 DIRECT ENERGY CONVERSION↗

TH-CD-BRA-10: Towards Reference Dosimetry of MR-Linacs Using a Clinical Probe-Format Calorimeter

Purpose: To evaluate the influence of a 1.5 T magnetic field (B-field) on the response of a small-scale graphite calorimeter probe (GPC) developed for use as a novel clinical reference dosimeter. Characterization of the GPC was also assessed in a hybrid MRI-linac (MRL) clinical prototype by performing absolute dosimetry in multiple detector orientations. Methods: B-field influence was characterized using a variable-strength electromagnet system located 280 cm from the source of a clinical linac. The GPC was used to perform a total of 160 absolute dose measurements (6 MV, 920 MU/min) in a water phantom placed between the poles of the electromagnet. The magnitude of the B-field between the poles was varied in the range of 0 – 1.5 T. The relative response of the GPC was determined and compared to that of a thimble type ionization chamber (Exradin A1SL, Standard Imaging). Next, 65 dose measurements were performed using the GPC in a clinical MRL field (7 MV, 620 MU/min) to quantify the rotational dependence of the detector in the presence of a 1.5 T B-field. The GPC was rotated in steps of 90° inside a graphite phantom (SSD 140 cm, depth 2.5 cm) for two detector orientations (parallel and perpendicular to the B field). Results: Relative to the zero B-field condition, the A1SL chamber exhibited an average overresponse of +1.2 % ± 0.03 % at a B-field of 1.5 T, while the GPC under-responded on average by −0.5 % ± 0.9 %. For the MRL measurements, no significant differences were observed between the parallel and perpendicular orientations. In both cases, a rotational dependence of approximately ±1 % was measured. Conclusion: This work suggests that the B-field has minimal influence on the response of the GPC, making it a potentially attractive solution for clinical MRL reference dosimetry. This work has been supported in part by the CREATE Medical Physics Research Training Network NSERC grant RGPIN 432290, as well as NSERC grants RGPIN 298191 & 435608. JR is a scholar from The Terry Fox Foundation Strategic Training Initiative for Excellence in Radiation Research for the 21st Century (EIRR21).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗