Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERROGATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Wireless Passive Ceramic Sensor for Far-Field Temperature Measurement at High Temperatures

A passive wireless high-temperature sensor for far-field applications was developed for stable temperature sensing up to 1000 °C. The goal is to leverage the properties of electroceramic materials, including adequate electrical conductivity, high-temperature resilience, and chemical stability in harsh environments. Initial sensors were fabricated using Ag for operation to 600 °C to achieve a baseline understanding of temperature sensing principles using patch antenna designs. Fabrication then followed with higher temperature sensors made from (In, Sn) O2 (ITO) for evaluation up to 1000 °C. A patch antenna was modeled in ANSYS HFSS to operate in a high-frequency region (2.5–3.5 GHz) within a 50 × 50 mm2 confined geometric area using characteristic material properties. The sensor was fabricated on Al2O3 using screen printing methods and then sintered at 700 °C for Ag and 1200 °C for ITO in an ambient atmosphere. Sensors were evaluated at 600 °C for Ag and 1000 °C for ITO and analyzed at set interrogating distances up to 0.75 m using ultra-wideband slot antennas to collect scattering parameters. The sensitivity (average change in resonant frequency with respect to temperature) from 50 to 1000 °C was between 22 and 62 kHz/°C which decreased as interrogating distances reached 0.75 m.

47 OTHER INSTRUMENTATION↗

Acoustic Sensing Fiber Coupled with Highly Magnetostrictive Ribbon for Small-Scale Magnetic-Field Detection

Fiber-optic sensing has shown promising development for use in detecting magnetic fields for downhole and biomedical applications. Coupling existing fiber-based strain sensors with highly magnetostrictive materials allows for a new method of magnetic characterization capable of distributed and high-sensitivity field measurements. This study investigates the strain response of the highly magnetostrictive alloys Metglas® 2605SC and Vitrovac® 7600 T70 using Fiber Bragg Grating (FBG) acoustic sensors and an applied AC magnetic field. Sentek Instrument’s picoDAS interrogated the distributed FBG sensors set atop a ribbon of magnetostrictive material, and the corresponding strain response transferred to the fiber was analyzed. Using the Vitrovac® ribbon, a minimal detectable field amplitude of 60 nT was achieved. Using Metglas®, an even better sensitivity was demonstrated, where detected field amplitudes as low as 3 nT were measured via the strain response imparted to the FBG sensor. Distributed FBG sensors are readily available commercially, easily integrated into existing interrogation systems, and require no bonding to the magnetostrictive material for field detection. The simple sensor configuration with nanotesla-level sensitivity lends itself as a promising means of magnetic characterization and demonstrates the potential of fiber-optic acoustic sensors for distributed measurements.

Dejneka, Zach (ORCID:0000000179415708)↗

Synchrotron FTIR imaging of OH in quartz mylonites

Previous measurements of water in deformed quartzites using conventional Fourier transform infrared spectroscopy (FTIR) instruments have shown that water contents of larger grains vary from one grain to another. However, the non-equilibrium variations in water content between neighboring grains and within quartz grains cannot be interrogated further without greater measurement resolution, nor can water contents be measured in finely recrystallized grains without including absorption bands due to fluid inclusions, films, and secondary minerals at grain boundaries. Synchrotron infrared (IR) radiation coupled to a FTIR spectrometer has allowed us to distinguish and measure OH bands due to fluid inclusions, hydrogen point defects, and secondary hydrous mineral inclusions through an aperture of 10 µm for specimens > 40 µm thick. Doubly polished infrared (IR) plates can be prepared with thicknesses down to 4–8 µm, but measurement of small OH bands is currently limited by strong interference fringes for samples < 25 µm thick, precluding measurements of water within individual, finely recrystallized grains. By translating specimens under the 10 µm IR beam by steps of 10 to 50 µm, using a software-controlled x - y stage, spectra have been collected over specimen areas of nearly 4.5 mm 2 . This technique allowed us to separate and quantify broad OH bands due to fluid inclusions in quartz and OH bands due to micas and map their distributions in quartzites from the Moine Thrust (Scotland) and Main Central Thrust (Himalayas). Mylonitic quartzites deformed under greenschist facies conditions in the footwall to the Moine Thrust (MT) exhibit a large and variable 3400 cm -1 OH absorption band due to molecular water, and maps of water content corresponding to fluid inclusions show that inclusion densities correlate with deformation and recrystallization microstructures. Quartz grains of mylonitic orthogneisses and paragneisses deformed under amphibolite conditions in the hanging wall to the Main Central Thrust (MCT) exhibit smaller broad OH bands, and spectra are dominated by sharp bands at 3595 to 3379 cm -1 due to hydrogen point defects that appear to have uniform, equilibrium concentrations in the driest samples. The broad OH band at 3400 cm -1 in these rocks is much less common. The variable water concentrations of MT quartzites and lack of detectable water in highly sheared MCT mylonites challenge our understanding of quartz rheology. However, where water absorption bands can be detected and compared with deformation microstructures, OH concentration maps provide information on the histories of deformation and recovery, evidence for the introduction and loss of fluid inclusions, and water weakening processes.

36 MATERIALS SCIENCE↗

A randomized multiplex CRISPRi-Seq approach for the identification of critical combinations of genes

Identifying virulence-critical genes from pathogens is often limited by functional redundancy. To rapidly interrogate the contributions of combinations of genes to a biological outcome, we have developed a mu ltiplex, r andomized C RISPR i nterference s equencing (MuRCiS) approach. At its center is a new method for the randomized self-assembly of CRISPR arrays from synthetic oligonucleotide pairs. When paired with PacBio long-read sequencing, MuRCiS allowed for near-comprehensive interrogation of all pairwise combinations of a group of 44 Legionella pneumophila virulence genes encoding highly conserved transmembrane proteins for their role in pathogenesis. Both amoeba and human macrophages were challenged with L. pneumophila bearing the pooled CRISPR array libraries, leading to the identification of several new virulence-critical combinations of genes. lpg2888 and lpg3000 were particularly fascinating for their apparent redundant functions during L. pneumophila human macrophage infection, while lpg3000 alone was essential for L. pneumophila virulence in the amoeban host Acanthamoeba castellanii . Thus, MuRCiS provides a method for rapid genetic examination of even large groups of redundant genes, setting the stage for application of this technology to a variety of biological contexts and organisms.

59 BASIC BIOLOGICAL SCIENCES↗

A randomized multiplex CRISPRi-Seq approach for the identification of critical combinations of genes

Identifying virulence-critical genes from pathogens is often limited by functional redundancy. To rapidly interrogate the contributions of combinations of genes to a biological outcome, we have developed a multiplex, randomized CRISPR interference sequencing (MuRCiS) approach. At its center is a new method for the randomized self-assembly of CRISPR arrays from synthetic oligonucleotide pairs. When paired with PacBio long-read sequencing, MuRCiS allowed for near-comprehensive interrogation of all pairwise combinations of a group of 44 Legionella pneumophila virulence genes encoding highly conserved transmembrane proteins for their role in pathogenesis. Both amoeba and human macrophages were challenged with L. pneumophila bearing the pooled CRISPR array libraries, leading to the identification of several new virulence-critical combinations of genes. lpg2888 and lpg3000 were particularly fascinating for their apparent redundant functions during L. pneumophila human macrophage infection, while lpg3000 alone was essential for L. pneumophila virulence in the amoeban host Acanthamoeba castellanii. Thus, MuRCiS provides a method for rapid genetic examination of even large groups of redundant genes, setting the stage for application of this technology to a variety of biological contexts and organisms.

79 ASTRONOMY AND ASTROPHYSICS↗

A randomized multiplex CRISPRi-Seq approach for the identification of critical combinations of genes

Identifying virulence-critical genes from pathogens is often limited by functional redundancy. To rapidly interrogate the contributions of combinations of genes to a biological outcome, we have developed a mu ltiplex, r andomized C RISPR i nterference s equencing (MuRCiS) approach. At its center is a new method for the randomized self-assembly of CRISPR arrays from synthetic oligonucleotide pairs. When paired with PacBio long-read sequencing, MuRCiS allowed for near-comprehensive interrogation of all pairwise combinations of a group of 44 Legionella pneumophila virulence genes encoding highly conserved transmembrane proteins for their role in pathogenesis. Both amoeba and human macrophages were challenged with L. pneumophila bearing the pooled CRISPR array libraries, leading to the identification of several new virulence-critical combinations of genes. lpg2888 and lpg3000 were particularly fascinating for their apparent redundant functions during L. pneumophila human macrophage infection, while lpg3000 alone was essential for L. pneumophila virulence in the amoeban host Acanthamoeba castellanii . Thus, MuRCiS provides a method for rapid genetic examination of even large groups of redundant genes, setting the stage for application of this technology to a variety of biological contexts and organisms.

Ellis, Nicole A. (ORCID:0000000195928415)↗

Spectrum tailoring of the neutron energy spectrum in the context of delayed neutron detection

For the purpose of measuring plutonium mass in spent fuel, a delayed neutron instrument is of particular interest since, if properly designed, the delayed neutron signal from {sup 235}U is significantly stronger than the signature from {sup 239}Pu or {sup 241}Pu. A key factor in properly designing a delayed neutron instrument is to minimize the fission of {sup 238}U. This minimization is achieved by keeping the interrogating neutron spectrum below {approx} 1 MeV. In the context of spent fuel measurements it is desirable to use a 14 MeV (deuterium and tritium) neutron generator for economic reasons. Spectrum tailoring is the term used to describe the inclusion of material between the 14 MeV neutrons and the interrogated object that lower the neutron energy through nuclear reactions and moderation. This report quantifies the utility of different material combination for spectrum tailoring.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Differential die-away technique for determination of the fissile contents in spent fuel assembly

Monte Carlo simulations were performed for the differential die-away (DDA) technique to quantify its capability to measure the fissile contents in spent fuel assemblies of 64 different cases in terms of initial enrichment, burnup, and cooling time. The DDA count rate varies according to the contents of fissile isotopes such as {sup 235}U, {sup 239}Pu, and {sup 241}Pu contained in the spent fuel assembly. The effective {sup 239}Pu concept was introduced to quantify the total fissile mass of spent fuel by weighting the relative signal contributions of {sup 235}U and {sup 241}Pu compared to that of {sup 239}Pu. The Monte Carlo simulation results show that the count rate of the DDA instrument for a spent fuel assembly of 4% initial enrichment, 45 GWD/MTU burnup, and 5 year cooling time is {approx} 9.8 x 10{sup 4} counts per second (c/s) with the 100-Hz repeated interrogation pattern of 0 to 10 {micro}s interrogation, 0.2 ms to 1 ms counting time, and 1 x 10{sup 9} n/s neutron source. The {sup 244}Cm neutron background count rate for this counting time scheme is {approx} 1 x 10{sup 4} c/s, and thus the signal to background ratio is {approx}10.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Innovative use of adhesive interface characteristics to nondestructively quantify the strength of bonded joints.

Advances in structural adhesives have permitted engineers to contemplate the use of bonded joints in areas that have long been dominated by mechanical fasteners and welds. Although strength, modulus, and toughness have been improved in modern adhesives, the typical concerns with using these polymers still exist. These include concerns over long-term durability and an inability to quantify bond strength (i.e., identify weak bonds) in adhesive joints. Bond deterioration in aging structures and bond strength in original construction are now critical issues that require more than simple flaw detection. Whether the structure involves metallic or composite materials, it is necessary to extend inspections beyond the detection of disbond flaws to include an assessment of the strength of the bond. Use of advanced nondestructive inspection (NDI) methods to measure the mechanical properties of a bonded joint and associated correlations with post-inspection failure tests have provided some clues regarding the key parameters involved in assessing bond strength. Recent advances in ultrasonic- and thermographic-based inspection methods have shown promise for measuring such properties. Specialized noise reduction and signal enhancement schemes have allowed thermographic interrogations to image the subtle differences between bond lines of various strengths. Similarly, specialized ultrasonic (UT) inspection techniques, including laser UT, guided waves, UT spectroscopy, and resonance methods, can be coupled with unique signal analysis algorithms to accurately characterize the properties of weak interfacial bonds. The generation of sufficient energy input levels to derive bond strength variations, the production of sufficient technique sensitivity to measure such minor response variations, and the difficulty in manufacturing repeatable weak bond specimens are all issues that exacerbate these investigations. The key to evaluating the bond strength lies in the ability to exploit the critical characteristics of weak bonds such as nonlinear responses, poor transmission of shear waves, and changes in response to stiffness-based interrogations. This paper will present several ongoing efforts that have identified promising methods for quantifying bond strength and discuss some completed studies that provide a foundation for further evolution in weak bond assessments.

36 MATERIALS SCIENCE↗

Non-destructive assay of spent nuclear fuel using passive neutron Albedo reactivity

Passive Neutron Albedo Reactivity (PNAR) is one of fourteen techniques that has been researched and evaluated to form part of a comprehensive and integrated detection system for the non-destructive assay (NDA) of spent nuclear fuel. PNAR implemented with {sup 3}He tubes for neutron detection (PNAR-{sup 3}He) is the measurement of time correlated neutrons from a spent fuel assembly with and without a Cadmium (Cd) layer surrounding the assembly. PNAR utilizes the self-interrogation of the fuel via reflection of neutrons born in the fuel assembly back in to the fuel assembly. The neutrons originate primarily from spontaneous fission events within the fuel itself (Curium-244) but are amplified by multiplication. The presence and removal of the Cd provides two measurement conditions with different neutron energy spectra and therefore different interrogating neutron characteristics. Cd has a high cross-section of absorption for slow neutrons and therefore greatly reduces the low energy (thermal) neutron fluence rate returning. The ratios of the Singles, Doubles and Triples count rates obtained in each case are known as the Cd ratios, which are related to fissile content. A potential safeguards application for which PNAR-{sup 3}He is particularly suited is 'fingerprinting'. Fingerprinting could function as an alternative to plutonium (Pu) mass determination; providing confidence that material was not diverted during transport between sites. PNAR-{sup 3}He has six primary NDA signatures: Singles, Doubles and Triples count rates measured with two energy spectra at both shipping and receiving sites. This is to uniquely identify the fuel assembly, and confirm no changes have taken place during transport. Changes may indicate all attempt to divert material for example. Here, the physics of the PNAR-{sup 3}He concept will be explained, alongside a discussion on the development of a prototypical PNAR-{sup 3}He instrument using simulation. The capabilities and performance of the conceptual instrument will be summarized, in the context of (a) quantifying Pu mass in spent fuel assemblies and (b) detecting pin diversion (through a discrepancy between declared and measured properties of the fuel assembly) when the instrument is deployed. These quantitative capabilities are complementary to the 'fingerprinting' capability which is part of ensuring continuity of knowledge and custody of spent nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determining plutonium mass in spent fuel with non-destructive assay techniques - NGSU research overview and update on 6 NDA techniques

This poster is one of two complementary posters. The Next Generation Safeguards Initiative (NGSI) of the U.S. DOE has initiated a multi-lab/university collaboration to quantify the plutonium (Pu) mass in, and detect the diversion of pins from, spent nuclear fuel assemblies with non-destructive assay (NDA). This research effort has the goal of quantifying the capability of 14 NDA techniques as well as training a future generation of safeguards practitioners. By November of 2010, we will be 1.5 years into the first phase (2.5 years) of work. This first phase involves primarily Monte Carlo modelling while the second phase (also 2.5 years) will focus on experimental work. The goal of phase one is to quantify the detection capability of the various techniques for the benefit of safeguard technology developers, regulators, and policy makers as well as to determine what integrated techniques merit experimental work, We are considering a wide range of possible technologies since our research horizon is longer term than the focus of most regulator bodies. The capability of all of the NDA techniques will be determined for a library of 64 17 x 17 PWR assemblies [burnups (15, 30, 45, 60 GWd/tU), initial enrichments (2, 3, 4, 5%) and cooling times (1, 5, 20, 80 years)]. The burnup and cooling time were simulated with each fuel pin being comprised of four radial regions. In this paper an overview of the purpose will be given as well as a technical update on the following 6 neutron techniques: {sup 252}Cf Interrogation with Prompt Neutron Detection, Delayed Neutrons, Differential Die-Away, Differential Die-Away Self-Interrogation, Passive Neutron Albedo Reactivity, Self-Integration Neutron Resonance Densitometry. The technical update will quantify the anticipated performance of each technique for the 64 assemblies of the spent fuel library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress on Establishing the Feasibility of Lead Slowing Down Spectroscopy for Direct Measurement of Plutonium in Used Fuel

Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) of next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT continues to support a multi-institutional collaboration to address the feasibility of Lead Slowing Down Spectroscopy (LSDS) as an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today’s confirmatory assay methods. An LSDS is comprised of a stack of lead (typically 1-6 m3) in which materials to be measured are placed in the lead and a pulse of neutrons is injected. The neutrons in this pulse lose energy due to inelastic and (subsequently) elastic scattering and the average energy of the neutrons decreases as the time increases by a well-defined relationship. In the interrogation energy region (~0.1-1000 eV) the neutrons have little energy spread (~30%) about the average neutron energy. Due to this characteristic, the energy of the (assay) neutrons can then be determined by measuring the time elapsed since the neutron pulse. By measuring the induced fission neutrons emitted from the used fuel, it is possible to determine isotopic-mass content by unfolding the unique structure of isotopic resonances across the interrogation energy region. This paper will present efforts on the development of time-spectral analysis algorithms, fast neutron detector advances, and validation and testing measurements.

Fission Chambers↗

High data-rate atom interferometers through high recapture efficiency

An inertial sensing system includes a magneto-optical trap (MOT) that traps atoms within a specified trapping region. The system also includes a cooling laser that cools the trapped atoms so that the atoms remain within the specified region for a specified amount of time. The system further includes a light-pulse atom interferometer (LPAI) that performs an interferometric interrogation of the atoms to determine phase changes in the atoms. The system includes a controller that controls the timing of MOT and cooling laser operations, and controls the timing of interferometric operations to substantially recapture the atoms in the specified trapping region. The system includes a processor that determines the amount inertial movement of the inertial sensing system based on the determined phase changes in the atoms. Also, a method of inertial sensing using this inertial sensing system includes recapture of atoms within the MOT following interferometric interrogation by the LPAI.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nuclear Material Detection by One-Short-Pulse-Laser-Driven Neutron Source

Covered in the PowerPoint presentation are the following areas: Motivation and requirements for active interrogation of nuclear material; laser-driven neutron source; neutron diagnostics; active interrogation of nuclear material; and, conclusions, remarks, and future works.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributed gas detection system and method

A distributed gas detection system includes one or more hollow core fibers disposed in different locations, one or more solid core fibers optically coupled with the one or more hollow core fibers and configured to receive light of one or more wavelengths from a light source, and an interrogator device configured to receive at least some of the light propagating through the one or more solid core fibers and the one or more hollow core fibers. The interrogator device is configured to identify a location of a presence of a gas-of-interest by examining absorption of at least one of the wavelengths of the light at least one of the hollow core fibers.

36 MATERIALS SCIENCE↗

Enhancing the Security of TIDs Using OSL

Tamper indicating devices (TIDs) such as tags and seals are integral to the safety and security of both equipment and nuclear material. They find prominence in both safeguards and arms control, yet many of the tags and seals in use today have been around for many years, with little or no serious modifications and security updates over their lifetime. There are many very simple changes or additions that can be implemented that will significantly enhance the security and robustness of both tags and seals. Incorporating optically stimulated luminescent (OSL) material is one example. OSL materials have found wide use in the nuclear community, currently in the form of millions of personnel dosimeters. However, the same properties that make it useful for dosimetry, can be utilized as a security feature in tags and seals to provide tamper indication, and potentially unique identification. When OSL materials are interrogated with specific wavelengths of light, they will excite and emit light at different, specific wavelengths. PNNL has undertaken to utilize this unique property of OSL material and incorporate the material into commercially available tags and seals. Currently PNNL is exploring two options; working with a manufacturer to incorporate OSL prior to distribution, or integration into commercially purchased TIDs just prior to use. PNNL is also developing a hand-held reader to interrogate and measure the light emitted from the OSL incorporated tags and seals. This paper discusses the evolution of this endeavor and the progress made to date. As part of this discussion, the success and future use of the idea of incorporating OSL material into tags and seals to enhance security and provide tamper indication will also be provided.

Miller, Steven D.↗

A Novel Fiber-Bragg-Grating-Based Unique Identifier for Use in Tags and Seals

Tags and seals are important tools used in safeguards regimes for the control of nuclear materials. Vital to a successful tag or seal is the ability to securely, uniquely, and positively distinguish it from others of the same kind. This allows one to validate that items entered into an inspection regime to which the tag or seal is affixed are as claimed. We are developing a new type of unique identifier (UID) for such applications that is based on fiber-Bragg grating (FBG) technology. The index of refraction of the core glass of a fiber optic can be locally and permanently altered if sensitized fibers are exposed to intense ultraviolet light. This can be used to create index modulations with a regular periodicity comparable to the wavelengths of light with which the fiber is used. If broadband illumination is sent down the fiber, any light that is in resonance with the modulations will be reflected back to the input end of the fiber where it can be detected. The shape of the returned spectrum can be set by the modulation pattern written into the fiber’s core. We take advantage of these properties to create a compact UID that contains several FBGs potted into a monolithic body. By connecting the UID to an optical interrogator, the complex spectral return can be uniquely identified with a short measurement, providing a robust identification. As a device based on narrowband spectral returns, FBGs are inherently radiation tolerant, making them ideal for use with nuclear materials. Further, they can be read out remotely via a long fiber optic or locally via brief connection to a portable optical interrogator. Because the spectral signature of FBGs is sensitive to external mechanical perturbations, we are exploring the ability to reversibly alter the signature obtained from the UID by applying controlled mechanical forces with a simple device. Such a “key” will allow different stakeholders to obtain their own unique signature from the device, providing a new level of surety to safeguards inspections.

Ziock, Klaus-Peter↗