Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Probing early parton emissions in heavy ion collisions using the Lund jet plane

In scattering experiments, high-virtuality partons, i.e., quarks and gluons, initiate a series of additional parton emissions to create collimated sprays of particles known as jets. This paper presents a measurement of the Lund jet plane (LJP) of high-energy jets produced in lead-lead (PbPb) collisions and compares the results to data for proton-proton (pp) collisions. The LJP is formed by iteratively declustering the constituents of a jet into consecutive emissions and recording the relative transverse momentum ($k_\mathrm{T}$) and angle of the resulting emission with respect to its emitter. The angular distributions of two different $k_\mathrm{T}$ slices of the LJP are investigated for jets with radius parameter of 0.4 and transverse momentum in the range 200$-$1000 GeV. The PbPb (pp) data were recorded by the CMS experiment in 2018 (2017) and correspond to an integrated luminosity of 1.7 nb$^{-1}$ (301 pb$^{-1}$) at a nucleon-nucleon center-of-mass energy of 5.02 TeV. The measurement was designed to test whether the earliest jet emissions are produced before the formation of the quark-gluon plasma (QGP) in PbPb collisions. Within the experimental uncertainties, no significant difference is observed between the angular distribution of high-$k_\mathrm{T}$ emissions in \pp and PbPb collisions, which is consistent with these emissions occurring early in the jet evolution, before substantial interaction with the QGP.

Belyaev, Andrey [Yerevan Phys. Inst.] (ORCID:00000↗

Ion Injection Triggered EMIC Waves in the Earth's Magnetosphere

We present Van Allen Probe observations of electromagnetic ion cyclotron (EMIC) waves triggered solely due to individual substorm-injected ions in the absence of storms or compressions of the magnetosphere during 9 August 2015. The time at which the injected ions are observed directly corresponds to the onset of EMIC waves at the location of Van Allen Probe A (L = 5.5 and 18:06 magnetic local time). The injection was also seen at geosynchronous orbit by the Geostationary Operational Environmental Satellite and Los Alamos National Laboratory spacecraft, and the westward(eastward) drift of ions(electrons) was monitored by Los Alamos National Laboratory spacecraft at different local times. The azimuthal location of the injection was determined by tracing the injection signatures backward in time to their origin assuming a dipolar magnetic field of Earth. The center of this injection location was determined to be close to ~20:00 magnetic local time. Geostationary Operational Environmental Satellite and ground magnetometer responses confirm substorm onset at approximately the same local time. The observed EMIC wave onsets at Van Allen Probe were also associated with a magnetic field decrease. The arrival of anisotropic ions along with the decrease in the magnetic field favors the growth of the EMIC wave instability based on linear theory analysis.

58 GEOSCIENCES↗

Two-dimensional bispectral analysis of drift wave turbulence in a cylindrical plasma

Bispectral analysis and multichannel measurement are becoming attractive investigation tools in plasma fluctuation studies. In the Large Mirror Device-Upgrade, the measurement of fluctuations in the ion saturation-current with a 64-channel poloidal Langmuir probe array was performed. The two-dimensional (2D) (poloidal wave number and frequency) power spectrum showed a number of pronounced peaks and broadband fluctuations in the poloidal wave number-frequency space. We applied 2D bispectral analysis, which considers both the matching conditions of poloidal wave number and frequency, to the spatiotemporal waveform, and confirmed the nonlinear couplings between coherent-coherent, coherent-broadband, and broadband-broadband fluctuation components. More than ten peaks were revealed to have as their origins only three original parent modes generated in the plasma. Comparison between the theoretical estimate and experimental observation for the bicoherence showed good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discharge Characterization of 40 cm-Microwave ECR Ion Source and Neutralizer

Discharge characteristics of a 40 cm, 2.45 GHz Electron Cyclotron Resonance (ECR) ion thruster discharge chamber and neutralizer were acquired. Thruster bulk discharge plasma characteristics were assessed using a single Langmuir probe. Total extractable ion current was measured as a function of input microwave power and flow rate. Additionally, radial ion current density profiles at the thruster.s exit plane were characterized using five equally spaced Faraday probes. Distinct low and high density operating modes were observed as discharge input power was varied from 0 to 200 W. In the high mode, extractable ion currents as high as 0.82 A were measured. Neutralizer emission current was characterized as a function of flow rate and microwave power. Neutralizer extraction currents as high as 0.6 A were measured.

Foster, John E.↗

Highly excited Rydberg electron as a spectator to an ion-molecule reaction

We have theoretically studied the conditions of the behavior of a high Rydberg electron as a spectator to an ion-molecule reaction in high Rydberg neutral collisions. Adoption of a circular high Rydberg atom in the initial channel of the high Rydberg neutral collisions ensures the behavior of the high Rydberg electron as the spectator to interaction between an ion core of the high Rydberg atom and an incoming neutral species; i.e., the ion-molecule reaction. This theoretical consideration leads to equivalence between the high Rydberg neutral collision and the ion-molecule reaction with high accuracy. This equivalence gives us a possibility of probing the ion-molecule reaction at low energies without space-charge effects encountered in ion-beam experiments.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magnetically insulated baffled probe for real-time monitoring of equilibrium and fluctuating values of space potentials, electron and ion temperatures, and densities

By restricting the electron-collection area of a cold Langmuir probe compared to the ion-collection area, the probe floating potential can become equal to the space potential, and thus conveniently monitored, rather than to a value shifted from the space potential by an electron-temperature-dependent offset, i.e., the case with an equal-collection-area probe. This design goal is achieved by combining an ambient magnetic field in the plasma with baffles, or shields, on the probe, resulting in species-selective magnetic insulation of the probe collection area. This permits the elimination of electron current to the probe by further adjustment of magnetic insulation which results in an ion-temperature-dependent offset when the probe is electrically floating. Subtracting the floating potential of two magnetically insulated baffled probes, each with a different degree of magnetic insulation, enables the electron or ion temperature to be measured in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially resolved measurements of ion density and electron temperature in a dual-frequency capacitively coupled plasma by complete floating double probe technique

Spatially resolved measurements of the ion density and electron temperature in a dual-frequency capacitively coupled Ar discharge plasma are performed with a newly developed complete floating double probe. Axial and radial distributions of the ion density and electron temperature under various high-frequency (HF) power and gas pressure were studied in detail. Both the ion density and the electron temperature increased with increasing HF power. With increasing gas pressure from 1.3 to 9.3 Pa, the radial profile of ion density below the driven electrode experienced a change from ''bimodal'' to ''unimodal'' shape, with better uniformity being achieved at the optimal pressure of about 5 Pa. In addition, changing the axial profile of ion density was also observed with the peak shift toward the powered electrode at higher pressures. The measured results showed satisfying consistency with that of improved two dimensional fluid simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast Charging of Li-Ion Cells: Part I. Using Li/Cu Reference Electrodes to Probe Individual Electrode Potentials

Increasing the charge rate of Li-ion cells over 1–2C (full charge in 30–60 min) would be highly desirable, but high currents flowing through the active materials push these cells to their endurance limits. In this article, we aim to understand how such high-current regimes affect electrochemical properties of the cells. Formation of Li metal deposits is a recognized hazard of high-rate charging, as Li plating can overtake lithium intercalation in the negative electrode. Here we demonstrate how microprobe Li/Cu reference electrodes can be used to characterize the graphite anode and layered oxide (NCM523) cathode during constant-current (≤ 6C) voltage-limited (4.39 V) charging of Li-ion cells. These reference electrodes are used to monitor the onset of Li plating conditions in situ during cell charging. As the current increases over 3C, the anode potentials decrease below -40 mV causing lithium nucleation. Surprisingly, this nucleation (at least, initially) does not result in capacity fade or a higher anode impedance even in strongly polarized cells, so it appears that the nascent Li nuclei are isolated from electrolyte by the pre-existing solid electrolyte interphase. Our study shows that microprobe reference electrodes are an important diagnostic tool to characterize full-cell behavior in the high-current regimes.

25 ENERGY STORAGE↗

Ion velocities in a micro-cathode arc thruster

Ion velocities in the plasma jet generated by the micro-cathode arc thruster are studied by means of time-of-flight method using enhanced ion detection system (EIDS). The EIDS triggers perturbations (spikes) on arc current waveform, and the larger current in the spike generates denser plasma bunches propagating along with the mainstream plasma. The EIDS utilizes double electrostatic probes rather than single probes. The average Ti ion velocity is measured to be around 2 Multiplication-Sign 10{sup 4} m/s without a magnetic field. It was found that the application of a magnetic field does not change ion velocities in the interelectrode region while leads to ion acceleration in the free expanding plasma plume by a factor of about 2. Ion velocities of about 3.5 Multiplication-Sign 10{sup 4} m/s were detected for the magnetic field of about 300 mT at distance of about 100-200 mm from the cathode. It is proposed that plasma is accelerated due to Lorentz force. The average thrust is calculated using the ion velocity measurements and the cathode mass consumption rate, and its increase with the magnetic field is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How does a probe inserted into the discharge influence the plasma structure?

Shielding the bias applied to the probe by the sheath formed around it and determination of parameters of unperturbed plasmas are in the basis of the probe diagnostics. The results from a two-dimensional model of a discharge with a probe inserted in it show that the probe influences the spatial distribution of the plasma parameters in the entire discharge. The increase (although slight) in the electron temperature, due to the increased losses of charged particles on the additional wall in the discharge (mainly the probe holder), leads to redistribution of the plasma density and plasma potential, as shown by the results obtained at the floating potential of the probe. The deviations due to the bias applied to the probe tip are stronger in the ion saturation region of the probe characteristics. The pattern of the spatial redistribution of the plasma parameters advances together with the movement of the probe deeper in the discharge. Although probe sheaths and probe characteristics resulting from the model are shown, the study does not aim at discussions on the theories for determination of the plasma density from the ion saturation current. Regardless of the modifications in the plasma behavior in the entire discharge, the deviations of the plasma parameters at the position of the probe tip and, respectively, the uncertainty which should be added as an error when the accuracy of the probe diagnostics is estimated do not exceed 10%. Consequently, the electron density and temperature obtained, respectively, at the position of the plasma potential on the probe characteristics and from its transition region are in reasonable agreement with the results from the model of the discharge without a probe. Being in the scope of research on a source of negative hydrogen ions with the design of a matrix of small radius inductive discharges, the model is specified for a low-pressure hydrogen discharge sustained in a small-radius tube.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Discharge Chamber Plasma Structure of a 30-cm NSTAR-Type Ion Engine

Single Langmuir probe measurements are presented over a two-dimensional array of locations in the near Discharge Cathode Assembly (DCA) region of a 30-cm diameter ring cusp ion thruster over a range of thruster operating conditions encompassing the high-power half of the NASA throttling table. The Langmuir probe data were analyzed with two separate methods. All data were analyzed initially assuming an electron population consisting of Maxwellian electrons only. The on-axis data were then analyzed assuming both Maxwellian and primary electrons. Discharge plasma data taken with beam extraction exhibit a broadening of the higher electron temperature plume boundary compared to similar discharge conditions without beam extraction. The opposite effect is evident with the electron/ion number density as the data without began, extraction appears to be more collimated than the corresponding data with beam extraction. Primary electron energy and number densities are presented for one operating condition giving an order of magnitude of their value and the error associated with this calculation.

Herman, Daniel A.↗

Nearly Complete Isobar Suppression by Photodetachment

The efficiency of selective suppression of negative ions by photodetachment in a gas-filled radio frequency quadrupole ion cooler was investigated with a new detection method. A neodymium doped yttrium aluminum garnet laser beam at 1064 nm was used to remove Co ions in the radio frequency quadrupole cooler and the remaining ions were then probed by photodetachment and neutral particle detection. More than 99.99% suppression of the Co ions was observed. Under identical conditions, only 20% of a Ni beam was suppressed. The results demonstrate that this isobar suppression technique can lead to nearly complete elimination of certain isobaric contaminants in negative ion beams, opening up new experimental possibilities in nuclear and atomic research and accelerator mass spectrometry.

43 PARTICLE ACCELERATORS↗

Analyses of ∼0.05-2 Mev Ions Associated With the 2022 February 16 Esp Event Observed by Parker Solar Probe

We present analyses of 0.05–2 MeV ions from the 2022 February 16 energetic storm particle event observed by Parker Solar Probe's (PSP) IS⊙IS/EPI-Lo instrument at 0.35 au from the Sun. This event was characterized by an enhancement in ion fluxes from a quiet background, increasing gradually with time with a nearly flat spectrum, rising sharply near the arrival of the coronal mass ejection (CME) driven shock, becoming nearly a power-law spectrum, then decaying exponentially afterwards, with a rate that was independent of energy. From the observed fluxes, we determine diffusion coefficients, finding that far upstream of the shock the diffusion coefficients are nearly independent of energy with a value of 10 20 cm 2 /s. Near the shock, the diffusion coefficients are more than one order of magnitude smaller and increase nearly linearly with energy. We also determine the source of energetic particles, by comparing ratios of the intensities at the shock to estimates of the quiet time intensity to predictions from diffusive shock acceleration theory. We conclude that the source of energetic ions is mostly the solar wind for this event. We also present potential interpretations of the near-exponential decay of the intensity behind the shock. One is that we suggest the shock was over-expanding when it crossed PSP and the energetic particle intensity decreased behind the shock to fill the expanding volume. Over-expanding CMEs could well be more common closer to the Sun, and this is an example of such a case.

Joe Giacalone↗

Measurement of axial neutral density profiles in a microwave discharge ion thruster by laser absorption spectroscopy with optical fiber probes

In order to reveal the physical processes taking place within the ''{mu}10'' microwave discharge ion thruster, internal plasma diagnosis is indispensable. However, the ability of metallic probes to access microwave plasmas biased at a high voltage is limited from the standpoints of the disturbance created in the electric field and electrical isolation. In this study, the axial density profiles of excited neutral xenon were successfully measured under ion beam acceleration by using a novel laser absorption spectroscopy system. The target of the measurement was metastable Xe I 5p{sup 5}({sup 2}P{sup 0}{sub 3/2})6s[{sup 3}/{sub 2}]{sup 0}{sub 2} which absorbed a wavelength of 823.16 nm. Signals from laser absorption spectroscopy that swept a single-mode optical fiber probe along the line of sight were differentiated and converted into axial number densities of the metastable neutral particles in the plasma source. These measurements revealed a 10{sup 18} m{sup -3} order of metastable neutral particles situated in the waveguide, which caused two different modes during the operation of the {mu}10 thruster. This paper reports a novel spectroscopic measurement system with axial resolution for microwave plasma sources utilizing optical fiber probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Fe 2+ ions in Fe,H/SSZ-13 zeolites: FTIR spectroscopy of CO and NO probe molecules

The IR spectra of adsorbed CO and NO probe molecules were used to characterize the coordination chemistry of Fe2+ ions in solution ion exchanged Fe,H/SSZ-13 zeolites. The effects of Fe ion exchange levels, as well the sample pre-treatment conditions on the adsorption of these probe molecules were investigated. The ion exchange levels (in the range of the study) did not affect significantly the IR spectra of either probe molecule, the IR features and their intensity ratios were very similar. Experiments with both probe molecules substantiated the presence of two distinct types of Fe2+ ions in cationic positions. We assign these two Fe2+ ions to two distinct cationic positions: Fe2+ in 6R and 8R positions. NO initially adsorbs preferentially onto Fe2+ sites in the 6R position, and then populates sites in the 8R. Fe2+ ions in the 8R positions require the interaction of more than one NO molecule to move them out from their adsorbate-free cationic positions. As soon as they move from their stable positions, they are able to bind to multiple NO molecules, and form mostly tri-nitrosyls. These tri-nitrosyls, however, are only stable in the presence of gas phase NO; under dynamic vacuum they lose one of the NO molecules from their coordination sphere and form stable di-nitrosyls. The adsorption of CO is much weaker on Fe2+ sites than that of NO, and requires cryogenic sample temperatures to initiate CO adsorption. Under the conditions applied in this study, only mono-carbonyl formation was observed. Reduction in H2 at 773 K increased the number of Fe2+ adsorption sites, primarily in the 8R locations. Oxidation by N2O, on the other hand, selectively reduced the adsorption of both CO and NO on the Fe2+ sites in 8R positions. Adsorbed oxygen left behind from the decomposition of N2O at 573 K readily reacted with CO to produce CO2 even at 150 K. The authors gratefully acknowledge the US Department of Energy (DOE), Energy Efficiency and Renewable Energy, Vehicle Technologies Program for the support of this work. The research described in this paper was performed in the Environmental Molecular Sciences Laboratory (EMSL), a national scientific user facility sponsored by the DOE’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory (PNNL). PNNL is operated for the US DOE by Battelle.

coordination chemistry of Fe2+ ions↗

Fast ion charge exchange spectroscopy adapted for tangential viewing geometry in LHD

A tangential Fast Ion Charge eXchange Spectroscopy is newly applied on a Large Helical Device (LHD) for co/countercirculating fast ions, which are produced by high energy tangential negative-ion based neutral beam injection. With this new observation geometry, both the tangential-neutral beam (NB) and a low-energy radial-NB based on positive ions can be utilized as probe beams of the measurement. We have successfully observed Doppler-shifted H-alpha lights due to the charge exchange process between the probing NB and circulating hydrogen ions of around 100 keV in LHD plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the arcjet plume near field using electrostatic probes

The near field plum of a 1 kW class arcjet thruster was investigated using electrostatic probes of various geometries. The electron number densities and temperatures were determined in a simulated hydrazine plume at axial distances between 3 cm (1.2 in) and 15 cm (5.9 in) and radial distances extending to 10 cm (3.9 in) off centerline. Values of electron number densities obtained using cylindrical and spherical probes of different geometries agreed very well. The electron density on centerline followed a source flow approximation for axial distances as near as 3 cm (1.2 in) from the nozzle exit plane. The model agreed well with previously obtained data in the far field. The effects of propellant mass flow rate and input power level were also studied. Cylindrical probes were used to obtain ion streamlines by changing the probe orientation with respect to the flow. The effects of electrical configuration on the plasma characteristics of the plume were also investigated by using a segmented anode/nozzle thruster. The results showed that the electrical configuration in the nozzle affected the distribution of electrons in the plume.

Sankovic, John M.↗