Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Erosion of Extraction Electrodes of Ion Sources due to Sputtering

The effects upon erosion due to implanted atoms in extraction electrodes of an ion source have been investigated through calculating the sputtering yields with a Monte Carlo simulation code, ACAT. The results obtained with ACAT have indicated that the sputtering yields of extraction electrodes are substantially affected by the retention of implanted atoms depending upon the mass ratio of electrode materials and extracted ions from the source plasma. The enhanced erosion takes place as the heavier ion beam species like phosphor is implanted into lighter electrode material like carbon. Additional mixing of materials arising from ion source operation, such as hot cathode materials evaporation onto a carbon extraction electrode, can shorten the lifetime of the extraction electrodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and investigations of the superconducting magnet system for the multipurpose superconducting electron cyclotron resonance ion source

The production of intense beams of heavy ions with electron cyclotron resonance ion sources (ECRIS) is an important request at many accelerators. According to the ECR condition and considering semi-empirical scaling laws, it is essential to increase the microwave frequency together with the magnetic flux density of the ECRIS magnet system. A useful frequency of 28 GHz, therefore, requires magnetic flux densities above 2.2 T implying the use of superconducting magnets. A cooperation of European institutions initiated a project to build a multipurpose superconducting ECRIS (MS-ECRIS) in order to achieve an increase of the performances in the order of a factor of ten. After a first design of the superconducting magnet system for the MS-ECRIS, the respective cold testing of the built magnet system reveals a lack of mechanical performance due to the strong interaction of the magnetic field of the three solenoids with the sextupole field and the magnetization of the magnetic iron collar. Comprehensive structural analysis, magnetic field calculations, and calculations of the force pattern confirm thereafter these strong interactions, especially of the iron collar with the solenoidal fields. The investigations on the structural analysis as well as suggestions for a possible mechanical design solution are given.

43 PARTICLE ACCELERATORS↗

Incremental performance improvements for a surface-convergency H- ion source

We discuss some of the interventions on LANSCE's surface-conversion negative-hydrogen ion sources to increase reliability; lifetime and output without any major re-design of the machine. LANSCE's source presently delivers a baseline 16 mA, 60 Hz, 12% duty factor beam. We describe how better quality control and processing of tungsten filaments allow the comfortable completion of 28-day run cycles, how improved temperature control of the ion source body yields an increased H{sup -} output, how higher input power through an additional filament allows operations at plasma densities while maintaining the filament lifetime and how adequate electrode biasing inside the source provide some control over the beam Twiss parameters on exit.

43 PARTICLE ACCELERATORS↗

The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source

The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod axially into the plasma chamber. The extracted beam currents of oxygen charge states O{sup 3+}–O{sup 7+} were recorded at various tuner positions and frequencies in the range of 14.00–14.15 GHz. It was observed that the tuner position affects the beam currents of high charge state ions up to several tens of percent. In particular, it was found that at some tuner position / frequency combinations the plasma exhibited “mode-hopping” between two operating regimes. The results improve the understanding of the role of plasma chamber cavity properties on ECRIS performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam current controller for laser ion source

The present invention relates to the design and use of an ion source with a rapid beam current controller for experimental and medicinal purposes. More particularly, the present invention relates to the design and use of a laser ion source with a magnetic field applied to confine a plasma flux caused by laser ablation.

42 ENGINEERING↗

High-resolution mass spectrometer for liquid metal ion sources

Recently, a mass spectrometer for liquid metal ion sources (LMIS) has been built and set into operation. This device uses an E×B-filter as mass dispersive element and provides sufficient resolution to analyse the emission of clusters from LMIS to much higher mass ranges (>2000 amu) than commercially available mass filters for focused ion beam systems. It has also been shown that for small masses the composition of clusters from different isotopes can be resolved. Furthermore, a rather high fluence of monodisperse clusters in the range of 10{sup 6}–10{sup 7} clusters/s can be achieved with this setup. This makes it a promising tool for the preparation of mass selected clusters. In this contribution, theoretical considerations as well as technical details and the results of first measurements are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion source design for industrial applications

The design of broad-beam industrial ion sources is described. The approach used emphasizes refractory metal cathodes and permanent-magnet multipole discharge chambers. Design procedures and sample calculations are given for the discharge chamber, ion optics, cathodes, and magnetic circuit. Hardware designs are included for the isolator, cathode supports, anode supports, pole-piece assembly, and ion-optics supports. There are other ways of designing most ion source components, but the designs presented are representative of current technology and adaptable to a wide range of configurations.

Kaufman, H. R.↗

Plasma meniscus and extraction electrode studies of the ISIS H{sup -} ion source

In order to reduce the emittance and increase the transported beam current from the ISIS Penning-type H{sup -} ion source, improvements to the extraction system are required. This ion source is currently being commissioned on the front end test stand at the Rutherford Appleton Laboratory, which demands higher extraction energies, higher beam currents, and smaller emittances. To facilitate this, the present geometry requires optimization. This paper details the experimental and simulation studies performed of the plasma meniscus and the possible electrode geometry modifications needed to extract the highest quality beam.

43 PARTICLE ACCELERATORS↗

Kinetic modeling of particle dynamics in H{sup −} negative ion sources (invited)

Progress in the kinetic modeling of particle dynamics in H{sup −} negative ion source plasmas and their comparisons with experiments are reviewed, and discussed with some new results. Main focus is placed on the following two topics, which are important for the research and development of large negative ion sources and high power H{sup −} ion beams: (i) Effects of non-equilibrium features of EEDF (electron energy distribution function) on H{sup −} production, and (ii) extraction physics of H{sup −} ions and beam optics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Brightness measurement of an electron impact gas ion source for proton beam writing applications

We are developing a high brightness nano-aperture electron impact gas ion source, which can create ion beams from a miniature ionization chamber with relatively small virtual source sizes, typically around 100 nm. A prototype source of this kind was designed and successively micro-fabricated using integrated circuit technology. Experiments to measure source brightness were performed inside a field emission scanning electron microscope. The total output current was measured to be between 200 and 300 pA. The highest estimated reduced brightness was found to be comparable to the injecting focused electron beam reduced brightness. This translates into an ion reduced brightness that is significantly better than that of conventional radio frequency ion sources, currently used in single-ended MeV accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oscillatory instability development in extraction system of a negative ion source

Conditions of oscillatory instability development in the extraction system of a negative hydrogen ion source based on a volume-produced plasma are studied. Such an ion source is characterized by the presence of the parent gas in the extraction system due to the leakage from the gas-discharge chamber. The secondary electrons in the area of the ion-optical system become the reason of oscillation appearance and possible beam current modulation. Analytically the range of the stable beam propagation is found. The instability increment is shown to be rather small. Maximum increment of the oscillations corresponds to the beam velocity equal to the thermal velocity of plasma electrons. The group velocity of the oscillations is close to the beam velocity so the oscillations are convective. Simulation of the low energy beam propagation is performed in COMSOL Multiphysics, the beam current modulation being observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Arc discharge regulation of a megawatt hot cathode bucket ion source for the experimental advanced superconducting tokamak neutral beam injector

Arc discharge of a hot cathode bucket ion source tends to be unstable what attributes to the filament self-heating and energetic electrons backstreaming from the accelerator. A regulation method, which based on the ion density measurement by a Langmuir probe, is employed for stable arc discharge operation and long pulse ion beam generation. Long pulse arc discharge of 100 s is obtained based on this regulation method of arc power. It establishes a foundation for the long pulse arc discharge of a megawatt ion source, which will be utilized a high power neutral beam injection device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emittance study of a 28 GHz electron cyclotron resonance ion source for the Rare Isotope Science Project superconducting linear accelerator

A 28 GHz electron cyclotron resonance (ECR) ion source is being developed for use as an injector for the superconducting linear accelerator of the Rare Isotope Science Project. Beam extraction from the ECR ion source has been simulated using the KOBRA3-INP software. The simulation software can calculate charged particle trajectories in three dimensional complex magnetic field structures, which in this case are formed by the arrangement of five superconducting magnets. In this study, the beam emittance is simulated to understand the effects of plasma potential, mass-to-charge ratio, and spatial distribution. The results of these simulations and their comparison to experimental results are presented in this paper.

43 PARTICLE ACCELERATORS↗

Shell-Based Support Structure for the 45 GHz ECR Ion Source MARS-D

Superconducting electron cyclotron resonance ion sources (ECRISs) using NbTi coils and optimized for 28 GHz resonant heating have been successfully operated for almost two decades. Moving to higher heating frequencies requires increased magnetic fields, but traditional racetrack-and-solenoid ECRIS structures are at their limit using NbTi. Rather than moving to a superconductor untested in this field, we report the Mixed Axial and Radial field System (MARS) being developed at Lawrence Berkeley National Laboratory employs a novel closed-loop-coil design that more efficiently utilizes conductor fields and will allow the use of NbTi in a next-generation, 45 GHz ECRIS. This article presents the design of the shell-based support structure central to the MARS-D magnet design, as well as structural analysis of its components and optimization of pre-load parameters that will guarantee its successful operation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A negative ion source test facility

Progress is being made in the development of an Ion Source Test Facility (ISTF) by D-Pace Inc. in collaboration with Buckley Systems Ltd. in Auckland, NZ. The first phase of the ISTF is to be commissioned in October 2015 with the second phase being commissioned in March 2016. The facility will primarily be used for the development and the commercialization of ion sources. It will also be used to characterize and further develop various D-Pace Inc. beam diagnostic devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma studies of the permanent magnet electron cyclotron resonance ion source at Peking University

At Peking University (PKU) we have developed several 2.45 GHz Permanent Magnet Electron Cyclotron Resonance ion sources for PKUNIFTY, SFRFQ, Coupled RFQ and SFRFQ, and Dielectric-Wall Accelerator (DWA) projects (respectively, 50 mA of D{sup +}, 10 mA of O{sup +}, 10 mA of He{sup +}, and 50 mA of H{sup +}). In order to improve performance of these ion sources, it is necessary to better understand the principal factors that influence the plasma density and the atomic ion fraction. Theoretical analysis about microwave transmission and cut-off inside the discharge chamber were carried out to study the influence of the discharge chamber diameters. As a consequence, experimental studies on plasma density and ion fraction with different discharge chamber sizes have been carried out. Due to the difficulties in measuring plasma density inside the discharge chamber, the output beam current was measured to reflect the plasma density. Experimental results show that the plasma density increases to the maximum and then decreases significantly as the diameter changed from 64 mm to 30 mm, and the atomic ion fraction has the same tendency. The maximum beam intensity was obtained with the diameter of 35 mm, but the maximum atomic ion fraction with a diameter of 40 mm. The experimental results are basically accordant with the theoretical calculation. Details are presented in this paper.

43 PARTICLE ACCELERATORS↗

Physics of a magnetic filter for negative ion sources. I. Collisional transport across the filter in an ideal, 1D filter

Magnetic filters are used in negative ion sources for neutral beam injection in fusion devices to reduce the electron temperature in the extraction region in order to limit negative ion destruction by fast electrons. The drop in electron temperature through the filter is due to the enhanced residence time and collisional energy losses of electrons trapped in the magnetic field. The mechanisms controlling particle and energy transport through the magnetic filter in negative ion sources of the ITER type are still not clear and the aim of this paper is to clarify and quantify these mechanisms. A particle-in-cell Monte Carlo simulation is used to revisit and analyze the role and operation of the magnetic filter in an 'ideal' one-dimensional configuration and to study the stability of the one-dimensional solution in a two-dimensional configuration with periodic boundary conditions. The roles of collisions and instabilities on electron transport through the filter are discussed. The influence of a more realistic geometry on electron transport through the filter is analyzed in the companion paper [Boeuf et al., Phys. Plasmas 19, 113510 (2012)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗