Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

SU-E-J-260: Quantitative Image Feature Analysis of Multiphase Liver CT for Hepatocellular Carcinoma (HCC) in Radiation Therapy

Purpose: To identify the effective quantitative image features (radiomics features) for prediction of response, survival, recurrence and metastasis of hepatocellular carcinoma (HCC) in radiotherapy. Methods: Multiphase contrast enhanced liver CT images were acquired in 16 patients with HCC on pre and post radiation therapy (RT). In this study, arterial phase CT images were selected to analyze the effectiveness of image features for the prediction of treatment outcome of HCC to RT. Response evaluated by RECIST criteria, survival, local recurrence (LR), distant metastasis (DM) and liver metastasis (LM) were examined. A radiation oncologist manually delineated the tumor and normal liver on pre and post CT scans, respectively. Quantitative image features were extracted to characterize the intensity distribution (n=8), spatial patterns (texture, n=36), and shape (n=16) of the tumor and liver, respectively. Moreover, differences between pre and post image features were calculated (n=120). A total of 360 features were extracted and then analyzed by unpaired student’s t-test to rank the effectiveness of features for the prediction of response. Results: The five most effective features were selected for prediction of each outcome. Significant predictors for tumor response and survival are changes in tumor shape (Second Major Axes Length, p= 0.002; Eccentricity, p=0.0002), for LR, liver texture (Standard Deviation (SD) of High Grey Level Run Emphasis and SD of Entropy, both p=0.005) on pre and post CT images, for DM, tumor texture (SD of Entropy, p=0.01) on pre CT image and for LM, liver (Mean of Cluster Shade, p=0.004) and tumor texture (SD of Entropy, p=0.006) on pre CT image. Intensity distribution features were not significant (p>0.09). Conclusion: Quantitative CT image features were found to be potential predictors of the five endpoints of HCC in RT. This work was supported in part by the National Cancer Institute Grant R01CA172638.

60 APPLIED LIFE SCIENCES↗

The persistent shadow of the supermassive black hole of M 87. I. Observations, calibration, imaging, and analysis

In April 2019, the Event Horizon Telescope (EHT) Collaboration reported the first-ever event-horizon-scale images of a black hole, resolving the central compact radio source in the giant elliptical galaxy M 87. These images reveal a ring with a southerly brightness distribution and a diameter of ∼42 μas, consistent with the predicted size and shape of a shadow produced by the gravitationally lensed emission around a supermassive black hole. These results were obtained as part of the April 2017 EHT observation campaign, using a global very long baseline interferometric radio array operating at a wavelength of 1.3 mm. Here, we present results based on the second EHT observing campaign, taking place in April 2018 with an improved array, wider frequency coverage, and increased bandwidth. In particular, the additional baselines provided by the Greenland telescope improved the coverage of the array. Multiyear EHT observations provide independent snapshots of the horizon-scale emission, allowing us to confirm the persistence, size, and shape of the black hole shadow, and constrain the intrinsic structural variability of the accretion flow. We have confirmed the presence of an asymmetric ring structure, brighter in the southwest, with a median diameter of 43.3−3.1+1.5 μas. The diameter of the 2018 ring is remarkably consistent with the diameter obtained from the previous 2017 observations. On the other hand, the position angle of the brightness asymmetry in 2018 is shifted by about 30° relative to 2017. The perennial persistence of the ring and its diameter robustly support the interpretation that the ring is formed by lensed emission surrounding a Kerr black hole with a mass ∼6.5 × 109 M⊙. The significant change in the ring brightness asymmetry implies a spin axis that is more consistent with the position angle of the large-scale jet.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of mechanical properties and deformation behavior of highly irradiated 316L stainless steel from target modules at the Spallation Neutron Source using digital image correlation analysis

Tensile specimens with irradiation doses ranging from approximately 0.7 to 7.6 displacements per atom (dpa) were fabricated from 316L samples removed from Spallation Neutron Source (SNS) target vessels after service. Tensile tests were performed in conjunction with digital image correlation (DIC) characterization, which permitted detailed analysis of the strain distribution and deformation behavior of the specimen gauge sections during testing. The results show, while considerable hardening (500–700 MPa increase in yield strength) occurred in the 316L SNS target material with increasing dose, appreciable ductility (19–23% total elongation) remained in the material after irradiation to 7.6 dpa in the mixed neutron/proton environment of the SNS target region. The DIC data showed the strain distribution and deformation behavior of all irradiated specimens were nonuniform during testing. Strain localization in the form of deformation bands or “hotspots” was observed during testing, and in some specimens, the bands propagated as deformation waves along the gauge section. The “traveling wave” deformation behavior affected the amount of elongation each specimen achieved, and the scatter in the elongation data was attributed to the large variation in deformation behavior observed among different specimens. Bands of localized strain, or deformation bands, oriented at specific angles were observed in two-dimensional plots of the strain distribution in the gauge sections of some specimens. Overall, this paper describes the experimental procedures, results, and deformation behavior of tensile specimens from SNS targets after service and illustrates the value of DIC characterization during tensile testing of irradiated materials.

36 MATERIALS SCIENCE↗

Individual Wave Detection and Tracking within a Rotating Detonation Engine through Computer Vision Object Detection applied to High-Speed Images

Known for their simplistic design and continuous detonation, rotating detonation engines (RDEs) constitute a majority of current pressure gain combustion (PGC) research efforts. Experimental RDE operation times have been continuously extended through the use of rig cooling techniques. As the window of observable behavior is expanded, and as the technology matures toward eventual integration within gas turbines, monitoring techniques must evolve to better match industrial diagnostics. High-speed image analysis techniques prove useful to capture and evaluate the unsteady detonation behavior within the RDE. Traditional image analysis techniques, however, require extensive processing times which prohibit simultaneous monitoring. To better address this problem, a computer vision object detection methodology is proposed to quickly detect individual detonation waves within a single down-axis image. Detonation waves are detected in individual images by the implemented computer vision method You Only Look Once (YOLO) object detection network. In order to detect detonation waves, the network must first be trained using RDE images of interest, for which each required phase of network development is outlined. Detection of waves is improved through proper treatment of the collected image set, variation of Intersection over Union (IoU) and confidence thresholding, and through a parametric study of annotation dimensions. Each detected wave is described by its location and rotational direction, and locations are tracked to calculate wave velocity across each frame, leading to a timestep resolution of 20 µs. Wave velocities are also calculated through a series of frames, leading to a suitable average velocity estimation using as few as 10 frames. Uncertainty analysis accounting for variation in camera framerate, pixel width and annotation centroid locations estimates a total uncertainty of ±4.3% for velocity calculations, using the smallest annotation boxes. This method offers great reductions in processing times, as a step toward real-time monitoring of detonation waves within an RDE. Improving on previous studies, this technique is impartial to wave modes not included in the original training set and calculates wave velocities independent of high-speed pressure data. The ability to isolate waves within predicted bounding boxes will likely facilitate analysis of pixel intensity variation as an estimation of wave strength in future work.

Johnson, Kristyn↗

Individual Wave Detection and Tracking within a Rotating Detonation Engine through Computer Vision Object Detection applied to High-Speed Images

Known for their simplistic design and continuous detonation, rotating detonation engines (RDEs) constitute a majority of current pressure gain combustion (PGC) research efforts. Experimental RDE operation times have been continuously extended through the use of rig cooling techniques. As the window of observable behavior is expanded, and as the technology matures toward eventual integration within gas turbines, monitoring techniques must evolve to better match industrial diagnostics. High-speed image analysis techniques prove useful to capture and evaluate the unsteady detonation behavior within the RDE. Traditional image analysis techniques, however, require extensive processing times which prohibit simultaneous monitoring. To better address this problem, a computer vision object detection methodology is proposed to quickly detect individual detonation waves within a single down-axis image. Detonation waves are detected in individual images by the implemented computer vision method You Only Look Once (YOLO) object detection network. In order to detect detonation waves, the network must first be trained using RDE images of interest, for which each required phase of network development is outlined. Detection of waves is improved through proper treatment of the collected image set, variation of Intersection over Union (IoU) and confidence thresholding, and through a parametric study of annotation dimensions. Each detected wave is described by its location and rotational direction, and locations are tracked to calculate wave velocity across each frame, leading to a timestep resolution of 20 µs. Wave velocities are also calculated through a series of frames, leading to a suitable average velocity estimation using as few as 10 frames. Uncertainty analysis accounting for variation in camera framerate, pixel width and annotation centroid locations estimates a total uncertainty of ±4.3% for velocity calculations, using the smallest annotation boxes. This method offers great reductions in processing times, as a step toward real-time monitoring of detonation waves within an RDE. Improving on previous studies, this technique is impartial to wave modes not included in the original training set and calculates wave velocities independent of high-speed pressure data. The ability to isolate waves within predicted bounding boxes will likely facilitate analysis of pixel intensity variation as an estimation of wave strength in future work.

Johnson, Kristyn↗

Reference tissue normalization in longitudinal 18F-florbetapir positron emission tomography of late mild cognitive impairment

Background: Semiquantitative methods such as the standardized uptake value ratio (SUVR) require normalization of the radiotracer activity to a reference tissue to monitor changes in the accumulation of amyloid-β (Aβ) plaques measured with positron emission tomography (PET). The objective of this study was to evaluate the effect of reference tissue normalization in a test–retest 18F-florbetapir SUVR study using cerebellar gray matter, white matter (two different segmentation masks), brainstem, and corpus callosum as reference regions. Methods: We calculated the correlation between 18F-florbetapir PET and concurrent cerebrospinal fluid (CSF) Aβ1–42 levels in a late mild cognitive impairment cohort with longitudinal PET and CSF data over the course of 2 years. In addition to conventional SUVR analysis using mean and median values of normalized brain radiotracer activity, we investigated a new image analysis technique—the weighted two-point correlation function (wS2)—to capture potentially more subtle changes in Aβ-PET data. Results: Compared with the SUVRs normalized to cerebellar gray matter, all cerebral-to-white matter normalization schemes resulted in a higher inverse correlation between PET and CSF Aβ1–42, while the brainstem normalization gave the best results (high and most stable correlation). Compared with the SUVR mean and median values, the wS2 values were associated with the lowest coefficient of variation and highest inverse correlation to CSF Aβ1–42 levels across all time points and reference regions, including the cerebellar gray matter. Conclusions: The selection of reference tissue for normalization and the choice of image analysis method can affect changes in cortical 18F-florbetapir uptake in longitudinal studies.

59 BASIC BIOLOGICAL SCIENCES↗

Conditional random fields for pattern recognition applied to structured data

Pattern recognition uses measurements from an input domain, X, to predict their labels from an output domain, Y. Image analysis is one setting where one might want to infer whether a pixel patch contains an object that is “manmade” (such as a building) or “natural” (such as a tree). Suppose the label for a pixel patch is “manmade”; if the label for a nearby pixel patch is then more likely to be “manmade” there is structure in the output domain that can be exploited to improve pattern recognition performance. Modeling P(X) is difficult because features between parts of the model are often correlated. Therefore, conditional random fields (CRFs) model structured data using the conditional distribution P(Y|X = x), without specifying a model for P(X), and are well suited for applications with dependent features. This paper has two parts. First, we overview CRFs and their application to pattern recognition in structured problems. Our primary examples are image analysis applications in which there is dependence among samples (pixel patches) in the output domain. Second, we identify research topics and present numerical examples.

97 MATHEMATICS AND COMPUTING↗

MR texture analysis: potential imaging biomarker for predicting the chemotherapeutic response of patients with colorectal liver metastases

Purpose: The purpose of the study was to determine whether the pre-treated MR texture features of colorectal liver metastases (CRLMs) are predictive of therapeutic response after chemotherapy. Methods: The study included twenty-six consecutive patients (a total of 193 liver metastasis) with unrespectable CRLMs at our institution from August 2014 to February 2016. Lesions were categorized into either responding group or non-responding group according to changes in size. Texture analysis was quantified on T2-weighted images by two radiologists with consensus on regions of interest which were manually drawn on the largest cross-sectional area of the lesions. Five histogram features (mean, variance, skewness, kurtosis, and entropy{sup 1}) and five gray level co-occurrence matrix features (GLCM; angular second moment (ASM), entropy{sup 2}, contrast, correlation, and inverse difference moment (IDM)) were extracted. The texture parameters were statistically analyzed to identify the differences between the two groups, and the potential predictive parameters to differentiate the responding group from the non-responding group were subsequently tested using multivariable logistic regression analysis. Results: A total of 107 responding and 86 non-responding lesions were evaluated. A higher variance, entropy{sup 1}, contrast, entropy{sup 2} and a lower ASM, correlation, IDM were independently (P < 0.05) associated with a good response to chemotherapy with the areas under the ROC curves (AUCs) of 0.602–0.784. Variance (P < 0.001) and ASM (P = 0.001) remained potential predictive values to discriminate responding lesions from non-responding lesions when tested using multivariable logistic regression analysis. The highest AUC of the predictors from the association of variance and ASM was 0.814. Conclusion: MR texture features on pre-treated T2 images have the potential to predict the therapeutic response of colorectal liver metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase Time and Envelope Time in Time-Distance Analysis and Acoustic Imaging

Time-distance analysis and acoustic imaging are two related techniques to probe the local properties of solar interior. In this study, we discuss the relation of phase time and envelope time between the two techniques. The location of the envelope peak of the cross correlation function in time-distance analysis is identified as the travel time of the wave packet formed by modes with the same w/l. The phase time of the cross correlation function provides information of the phase change accumulated along the wave path, including the phase change at the boundaries of the mode cavity. The acoustic signals constructed with the technique of acoustic imaging contain both phase and intensity information. The phase of constructed signals can be studied by computing the cross correlation function between time series constructed with ingoing and outgoing waves. In this study, we use the data taken with the Taiwan Oscillation Network (TON) instrument and the Michelson Doppler Imager (MDI) instrument. The analysis is carried out for the quiet Sun. We use the relation of envelope time versus distance measured in time-distance analyses to construct the acoustic signals in acoustic imaging analyses. The phase time of the cross correlation function of constructed ingoing and outgoing time series is twice the difference between the phase time and envelope time in time-distance analyses as predicted. The envelope peak of the cross correlation function between constructed ingoing and outgoing time series is located at zero time as predicted for results of one-bounce at 3 mHz for all four data sets and two-bounce at 3 mHz for two TON data sets. But it is different from zero for other cases. The cause of the deviation of the envelope peak from zero is not known.

Chou, Dean-Yi↗

Efficient Workflows for Curation of Heterogeneous Data Supporting Modeling of U-Nb Alloy Aging

These are slides from a presentation summarizing a graduate research associate's summer project. The following topics are covered in these slides: data challenges in materials, aging in U-Nb Alloys, Building an Aging Model, Different Phase Trans. in U-Nb, the Challenge, Storing Materials Data, Example Data Source, Organizing Data: What is a Schema?, What does a "XML Schema" look like?, Our Data Schema: Nice and Simple, Storing Data: Materials Data Curation System (MDCS), Problem with MDCS: Slow Data Entry, Getting Literature into MDCS, Staging Data in Excel Document, Final Result: MDCS Records, Analyzing Image Data, Process for Making TTT Diagram, Bottleneck Number 1: Image Analysis, Fitting a TTP Boundary, Fitting a TTP Curve: Comparable Results, How Does it Compare to Our Data?, Image Analysis Workflow, Curating Hardness Records, Hardness Data: Two Key Decisions, Before Peak Age? - Automation, Interactive Viz, Which Transformation?, Microstructure-Informed Model, Tracking the Entire Process, General Problem with Property Models, Pinyon: Toolkit for Managing Model Creation, Tracking Individual Decisions, Jupyter: Docs and Code in One File, Hardness Analysis Workflow, Workflow for Aging Models, and conclusions.

36 MATERIALS SCIENCE↗

SU-C-BRF-02: Surface Imaging Based Analysis of Intra-Fraction Motion for Breast Radiotherapy Patients

Purpose: To quantify and characterize intrafraction motion for breast radiotherapy treatments using 3D surface imaging. Methods: Thirty free breathing breast patients were monitored with 3D surface imaging over a total of 831 monitoring sessions. Mean translations and rotations were calculated over each minute, each session, and over all sessions combined. The percentage of each session that the root mean square (RMS) of the linear translations were outside of 2 mm, 3 mm, 4 mm, and 5 mm were determined for each patient. Correlations between mean translations per minute and time and between standard deviation per minute and time were evaluated using Pearson's r value. Results: The mean RMS translation averaged over all patients was 2.63 mm +/- 1.63 mm. The patients spent an average of 52%, 24%, 11%, and 5% of the monitoring time outside of 2 mm, 3 mm, 4 mm, and 5 mm RMS tolerances, respectively. The RMS values averaged over all patients were 2.95 mm +/- 1.67 mm, 3.21 +/- 2.11, and 3.57 mm +/- 2.23 mm over the 5th, 10th, and 15th minutes of monitoring, respectively. The RMS values (r = 0.95, p = 0) and the standard deviations of the RMS values (r = 0.97, p = 0) both showed strong significant correlations with time. Conclusion: The majority of patients treatment time is spent within 5 mm of the isocenter. Patient position tends to drift with increasing time in the session. Treatment length should be considered when determining planning margins. An 8 mm margin on a target volume would account for two standard deviations of motion for a treatment up to 15 minutes in length.

60 APPLIED LIFE SCIENCES↗

Iodine imaging using spectral analysis

Existing radiographic imaging systems provide images which represent an integration or averaging over the energy spectrum. In order to provide noninvasive angiography it is necessary to image the relatively small amounts of iodine which are available following an intravenous administration. This is accomplished by making use of the special spectral characteristics of iodine. Two methods will be presented. One involves a special grating for encoding the iodine information in the form of a fine line pattern. This is subsequently decoded to provide images of iodinated structures which are otherwise almost invisible. The second method utilizes a scanned X-ray beam which is rapidly switched in the high energy region. In this region, iodine experiences significant variations in the attenuation coefficient while bone and soft tissue do not. An efficient and accurate X-ray detector can be used with scanned X-ray beams. This provides a high degree of sensitivity enabling the visualization of small vessels containing relatively dilute iodine.

Macovski, A.↗

TH-CD-206-01: Expectation-Maximization Algorithm-Based Tissue Mixture Quantification for Perfusion MRI

Purpose: To investigate the feasibility of estimating the tissue mixture perfusions and quantifying cerebral blood flow change in arterial spin labeled (ASL) perfusion MR images. Methods: The proposed perfusion MR image analysis framework consists of 5 steps: (1) Inhomogeneity correction was performed on the T1- and T2-weighted images, which are available for each studied perfusion MR dataset. (2) We used the publicly available FSL toolbox to strip off the non-brain structures from the T1- and T2-weighted MR images. (3) We applied a multi-spectral tissue-mixture segmentation algorithm on both T1- and T2-structural MR images to roughly estimate the fraction of each tissue type - white matter, grey matter and cerebral spinal fluid inside each image voxel. (4) The distributions of the three tissue types or tissue mixture across the structural image array are down-sampled and mapped onto the ASL voxel array via a co-registration operation. (5) The presented 4-dimensional expectation-maximization (4D-EM) algorithm takes the down-sampled three tissue type distributions on perfusion image data to generate the perfusion mean, variance and percentage images for each tissue type of interest. Results: Experimental results on three volunteer datasets demonstrated that the multi-spectral tissue-mixture segmentation algorithm was effective to initialize tissue mixtures from T1- and T2-weighted MR images. Compared with the conventional ASL image processing toolbox, the proposed 4D-EM algorithm not only generated comparable perfusion mean images, but also produced perfusion variance and percentage images, which the ASL toolbox cannot obtain. It is observed that the perfusion contribution percentages may not be the same as the corresponding tissue mixture volume fractions estimated in the structural images. Conclusion: A specific application to brain ASL images showed that the presented perfusion image analysis method is promising for detecting subtle changes in tissue perfusions, which is valuable for the early diagnosis of certain brain diseases, e.g. multiple sclerosis.

60 APPLIED LIFE SCIENCES↗

Mirostructure Characterization of Friction Consolidated Copper-Nickel using a Machine Learning Approach: Developing Process to Microstructure Associations

Friction consolidation (FC) is a solid phase processing approach where discrete material forms such as powders, chips, nuggets, etc. are densified via shear deformation. The precursors are placed in a billet container and brought in contact with a rotating tool that applying the desirable amount of normal force. Under the combined action of the rotation and normal pressure, the discrete precursor is consolidated through porosity reduction and shear deformation. FC is increasingly being studied as an attractive approach to manufacturing fully dense parts from powder forms owing to its ability to mix, alloy and consolidate difficult-to-process precursors in minimal number of process steps. Material consolidation and deformation in shear consolidation processes have been studied extensively previously for different material combinations previously. However, despite the extensive research in this area, understanding of the mechanistic processes in pore consolidation, deformation-induced mixing and material solubility during FC is still evolving. Material development using solid phase processing approaches such as FC is often performed based on research experience/education, which can be biased. Conventional analysis and simulation tools in this area tend to be successful only when material thermodynamic pathways and microstructural evolution sequences resulting from processing are clearly defined or known. They are not as effective for emerging advanced manufacturing technologies where material evolution pathways are not well established. The ability to predict optimal process parameters based on material chemistry and bulk properties is essential to accelerate materials design and processing, as are an understanding of the relevant structure-processing-property relationships. These structure-processing-property-performance relationships are at the core of materials science research. Microstructure characterization provides the link to these four core areas, often through visualizing material microstructure using imaging techniques. However, linking microstructure image data (i.e., micrographs) to variables of interest (e.g., processing parameters, material chemistry) in a reproducible, generalizable, and quantitative manner is a significant challenge. Typically, quantitatively linking image data to processing history relies on significant domain knowledge and manual or subject matter expert (SME)-heuristic based image analysis. Such an approach to image analysis has the potential to be biased, inefficient, and difficult to replicate.

36 MATERIALS SCIENCE↗

Advanced Characterization of Unconventional Oil and Gas Reservoirs to Enhance CO 2 Storage Resource Estimates – Organic Structure and Porosity of Organic Rich Shales

Poster presented at Mastering the Subsurface Through Technology Innovation, Partnerships and Collaboration: Carbon Storage and Oil and Natural Gas Technologies Review Meeting, Pittsburgh, Pennsylvania, August 1–3, 2017. Advanced analytical and image analysis techniques have been employed to examine the detailed structure of organic matter (OM) in the shales of the Bakken Formation. Samples from three different locations in the Bakken Formation with varying levels of thermal maturity (immature, marginally mature, and mature) were selected for analysis. The goal of this project is to use an advanced field emission scanning electron microscope (FESEM), image analysis, and computed tomography (CT) visualization techniques to identify and quantify key features that could affect CO 2 storage in unconventional formations.

02 PETROLEUM↗

Induction and quantification of gammma-H2AX foci following cx- and gamma-irradiaton

Following DNA damage the histone H2AX becomes phosphorylated and can be visualised by immunofluorescence as an indicator of DSBs in individual cells. Using a wild type hamster cell line (V79-4) exposed to either a-particles or to Co-60 gamma-rays to induce DNA DSBs at different doses (20-200OmGy), the dose dependent induction of gamma-H2AX foci were scored both manually (by eye) and using image analysis. A linearly dependence on dose was found for both radiations. The number of DSBs determined by image analysis after a post-irradiation period of 30 minutes at 37 C, is 16.6 foci/cell/Gy for alpha-irradiation and 12.2 foci/cell/Gy for gamma-irradiation; the latter being 3-4 times the levels observed by eye and comparable to gamma-radiation-induced levels of prompt DSBs more recently reported using pulse field gel electrophoresis (approx. 16 DSBs/Gy). The average size of the gamma-H2AX foci induced by alpha-irradiation (0.30 square micrometers) is approximately 1.5 times larger than those induced by gamma-irradiation (0.19 square micrometers). The timescale of induction and removal of DSBs up to 24 hours post-irradiation, was investigated with gamma-H2AX foci levels found to remain significantly higher than controls for 4 or 6 hours in gamma-irradiated samples or alpha irradiated samples, respectively. These results demonstrate that not only gamma radiation but also alpha-radiation induce phosphorylation of the H2AX histone in response to DSBs even at low doses (20mGy for gamma-rays, 1 track/cell on average for alpha-particles) and the variation in size and dephosphorylation of the induced foci is dependent on radiation quality (LET).

Leatherbarrow, E. L.↗

Image inversion analysis of the HST OTA (Hubble Space Telescope Optical Telescope Assembly), phase A

Technical work during September-December 1990 consisted of: (1) analyzing HST point source images obtained from JPL; (2) retrieving phase information from the images by a direct (noniterative) technique; and (3) characterizing the wavefront aberration due to the errors in the Hubble Space Telescope (HST) mirrors, in a preliminary manner. This work was in support of JPL design of compensating optics for the next generation wide-field planetary camera on HST. This digital technique for phase retrieval from pairs of defocused images, is based on the energy transport equation between these image planes. In addition, an end-to-end wave optics routine, based on the JPL Code 5 prescription of the unaberrated HST and WFPC, was derived for output of the reference phase front when mirror error is absent. Also, the Roddier routine unwrapped the retrieved phase by inserting the required jumps of +/- 2(pi) radians for the sake of smoothness. A least-squares fitting routine, insensitive to phase unwrapping, but nonlinear, was used to obtain estimates of the Zernike polynomial coefficients that describe the aberration. The phase results were close to, but higher than, the expected error in conic constant of the primary mirror suggested by the fossil evidence. The analysis of aberration contributed by the camera itself could be responsible for the small discrepancy, but was not verified by analysis.

Litvak, M. M.↗