Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Do Remote Camera Arrangements and Image Capture Settings Improve Individual Identification of Golden Eagles?

Individual identification of animals from camera traps has become an important task in wildlife research, but camera deployment methods often do not facilitate this important undertaking. Identification of individual golden eagles (Aquila chrysaetos) is possible using uniquely marked rectrices, but no studies have explored methods to maximize the rate of individual identification from camera images. Furthermore, our objectives were to assess whether different camera heights (1 m vs. 3 m), image capture settings (one image after a 1-min delay vs. burst of 5 images after a 30 sec delay), and arrangements relative to bait (dorsally vs. ventrally aimed) affected views of rectrices on golden eagles and our ability to identify individuals. We conducted our study from 15 December 2016 to 3 March 2017 on the Savannah River Site, South Carolina. First, we developed a scoring system based on views of rectrices and used a linear mixed-effects model to compare image scores among different camera arrangements and image settings. Next, after identifying individual eagles, we used generalized linear mixed-effects models to compare total individual eagle detections, total days an individual was detected, and probability of obtaining an unknown individual identification among camera arrangements and settings. Overall, we scored a total of 27,499 images, with 8,083 providing views of marked rectrices that allowed identification of 18 individual eagles. Average image scores and proportion of images suitable for individual identification were higher from elevated (3 m) camera arrangements than standard arrangements (1 m) across sites. Regardless of camera height, faster frequency of image capture provided more images that could be used to identify individuals and the most trap days per individual. Researchers and managers should consider deploying elevated cameras traps with faster frequency of image capture to improve data quality and potential for analysis of golden eagle populations and trends across the species’ range.

60 APPLIED LIFE SCIENCES↗

Computed tomography-based texture analysis of bladder cancer: differentiating urothelial carcinoma from micropapillary carcinoma

Purpose: The purpose of the study is to determine the feasibility of using computed tomography-based texture analysis (CTTA) in differentiating between urothelial carcinomas (UC) of the bladder from micropapillary carcinomas (MPC) of the bladder. Methods: Regions of interests (ROIs) of computerized tomography (CT) images of 33 MPCs and 33 UCs were manually segmented and saved. Custom MATLAB code was used to extract voxel information corresponding to the ROI. The segmented tumors were input to a pre-existing radiomics platform with a CTTA panel. A total of 58 texture metrics were extracted using four different texture extraction techniques and statistically analyzed using a Wilcoxon rank-sum test to determine the differences between UCs and MPCs. Results: Of the 58 texture metrics extracted using the gray level co-occurrence matrix (GLCM) and gray level difference matrix (GLDM), 28 texture metrics were statistically significant (p < 0.05) for differences in tumor textures and 27 texture metrics were statistically significant (p < 0.05) for peritumoral fat textures. The remaining nine metrics extracted using histogram and fast Fourier transform analyses did not show significant differences between the textures of the tumors and their peritumoral fat. Conclusions: CTTA shows that MPC have a more heterogeneous texture compared to UC. As visual discrimination of MPC from UC from clinical CT scans are difficult, results from this study suggest that tumor heterogeneity extracted using GLCM and GLDM may be a good imaging aid in segregating MPC from UC. This tool can aid clinicians in further sub-classifying bladder cancers on routine imaging, a process which has potential to alter treatment and patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of dual energy CT to improve diagnosis of non-traumatic abdominal vascular emergencies

Computed tomography angiography (CTA) is the modality of choice to evaluate abdominal vascular emergencies (AVE). CTA protocols are often complex and require acquisition of multiple phases to enable a variety of diagnosis such as acute bleeding, pseudoaneurysms, bowel ischemia, and dissection. With single energy CT (SECT), differentiating between calcium, coagulated blood, and contrast agents can be challenging based on their attenuation, especially when in small quantity or present as a mixture. With dual-energy CT (DECT), virtual monoenergetic (VM) and material decomposition (MD) image reconstructions enable more robust tissue characterization, improve contrast-enhancement, and reduce beam hardening artifacts. This article will demonstrate how radiologists can utilize DECT for various clinical scenarios in assessment of non-traumatic AVE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differentiation of duodenal gastrointestinal stromal tumors from hypervascular pancreatic neuroendocrine tumors in the pancreatic head using contrast-enhanced computed tomography

Purpose: To determine useful contrast-enhanced computed tomography (CE-CT) features in differentiating duodenal gastrointestinal stromal tumors (duodenal GISTs) from hypervascular pancreatic neuroendocrine tumors in the pancreatic head (pancreatic head NETs). Methods: Seventeen patients with pathologically confirmed duodenal GISTs and 25 with pancreatic NETs underwent preoperative CE-CT. CT image analysis included tumor size, morphology, and contrast enhancement. Receiver operating characteristic curves were performed, and cutoff values were calculated to determine CT findings with high sensitivity and specificity. Results: CT imaging showed duodenal GISTs with higher frequencies of tumor central location close to the duodenum and a predominantly solid tumor type when compared with pancreatic head NETs (p < 0.05 for both). Duodenal GISTs were larger than pancreatic head NETs (3.3 ± 0.9 cm vs. 2.5 ± 1.1 cm, p = 0.03). Duodenal GISTs had significantly lower CT attenuation values (112.9 ± 17.9HU vs. 137.4 ± 32.1HU, p < 0.01) at the arterial phase and higher CT attenuation values at the delayed phase (94.3 ± 7.9HU vs. 84.9 ± 10.4HU, p < 0.01) when compared with pancreatic head NETs. A CT attenuation value of ≤ 135 HU at the arterial phase (30 s) was 76% sensitive, 94.1% specific, and 83.3% accurate for the diagnosis of duodenal GISTs, while a CT attenuation value of ≥ 89.5 HU at the delayed phase (120 s) was 93.3% sensitive, 81.8% specific, and 76.2% accurate for the diagnosis of duodenal GISTs. Conclusion: Tumor central location, size, texture, and contrast enhancement are valuable characteristics for the differentiation between duodenal GISTs and hypervascular pancreatic head NETs during preoperative examination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interobserver agreement of computed tomography reporting standards for chronic pancreatitis

Aim: To assess the interobserver agreement of computed tomography (CT) reporting standards for chronic pancreatitis (CP). Subjects and methods: Retrospective analysis of CT of 47 patients (33 males and 11 females, age range 36 to 56 years) with CP who presented with abdominal pain (n = 41), steatorrhea (n = 37), and glucose intolerance (n = 31). The patients underwent CT study using a 16-multidetector CT scanner with a pancreatic protocol including a nonenhanced scan followed by pancreatic phase at 35 s and portal venous phase at 65 s after intravenous injection of nonionic contrast medium. Image analysis was performed by two radiologists according to reporting standards for CP. Results: There was excellent interobserver agreement (84.8 %) between the two reviewers in CT reporting standards for CP (K = 0.80, 95 % CI 0.75–0.85, P = 0.001). There was good interobserver agreement for pancreatic duct (PD) caliber (K = 0.71, 95 % CI 0.56–0.87, P = 0.001), PD contour (K = 0.76, 95 % CI 0.61–0.91, P = 0.001), PD stricture (K = 0.070, 95 % CI 0.53–0.88, P = 0.001), and distribution of findings (K = 0.69, 95 % CI 0.51–0.86, P = 0.001). There was excellent interobserver agreement for intraductal calculi (K = 0.84, 95 % CI 0.68–0.98, P = 0.001), pancreatic calcifications (K = 0.86, 95 % CI 0.84–0.98, P = 0.001), and pancreatic diameter (K = 0.87, 95 % CI 0.75–0.99, P = 0.001). Conclusion: CT reporting standards for CP is a reliable method for diagnosis of patients with CP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Society of abdominal radiology gastrointestinal bleeding disease-focused panel consensus recommendations for CTA technical parameters in the evaluation of acute overt gastrointestinal bleeding

Purpose: To formulate consensus recommendations for CT angiography technical parameters used to evaluate overt gastrointestinal (GI) bleeding. Methods: An electronic questionnaire consisting of 17 questions was sent to a panel of 16 radiologists with expertise on the imaging of GI bleeding from the Society of Abdominal Radiology GI Bleeding disease-focused panel to obtain consensus agreement on issues related to CTA technical parameters for imaging overt GI bleeding. A multi-round Delphi method of voting was performed to obtain consensus which was defined as ≥ 80% agreement. Results: Consensus agreement was reached in 15/17 (89%) of the questions including the technique for the administration of IV contrast, the number of phases, scan timing, and image reconstruction. Conclusions: A panel of experts on the imaging of GI bleeding from the Society of Abdominal Radiology was able to reach consensus on the majority of technical parameters used for CTA of overt GI bleeding. These recommendations should improve the quality of patient care by adopting these minimal technical requirements for optimal exam performance and lead to less variation in the performance of these exams which will facilitate collecting and comparing published data from different centers. These recommendations will need revisions as additional scientific data become available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of Automated Supplying Artery Tracking Software Using Multidetector-Row Computed Tomography Images for Emergent Transcatheter Arterial Embolization

PurposeTo assess the reliability of a prototype automated supplying artery tracking software (ASATS) using multidetector-row CT (MDCT) images in emergent TAE.Materials and MethodsConsecutive 53 patients underwent 57 sessions of emergent TAE during 7 months. Twenty-one cases were excluded due to a lack of CT data (n = 12) or negative angiographic findings (n = 9). Remaining 34 sessions of TAE and MDCT images in 32 patients (mean age 62.9 years; age range 37–92 years) were enrolled. ASATS was retrospectively conducted for the identification of supplying arteries which were confirmed with angiography (automated method). Manual modification was added as needed (semi-automated method). Two observers independently reviewed the MDCT images to detect supplying arteries (manual method). Detectability of supplying artery and time to analysis were compared among the automated, semi-automated, and manual methods by both observers.ResultsA total of 64 bleeding sites were demonstrated on angiography. The detectability was 28 (43.8%) for automated method, 53 (82.8%) for semi-automated method, 55 (85.9%) for observer 1, and 58 (90.6%) for observer 2. Detectability of semi-automated method was significantly better than of automated method (P = 0.000) and comparable with manual method by both observers (P = 0.193 and 0.081). Average time to analysis was 185.4 s for automated method, 297.2 s for semi-automated method, 186.2 s for observer 1, and 243.7 s for observer 2.ConclusionASATS has a sufficient ability to identify supplying arteries of bleeding by adding manual modification as needed and can be used for emergent TAE. Level of Evidence: Level 4, Case Control Study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Effects of SiO{sub 2} Content and Cooling Rate on Crystallization in Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} System Using In Situ Confocal Laser Scanning Microscopy

The crystallization behaviors of the Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} system in a non-equilibrium state with various chemical compositions and cooling rates were investigated by confocal laser scanning. Equilibrium samples were prepared in melt states and cooled at a rate of 1 K/min to produce samples in quasi-equilibrium states. The effect of SiO{sub 2} on the phase constitution was investigated using Image Analyzer, and the changes of the phase ratios were analyzed using activity values of Fe{sub 2}O{sub 3} calculated using FactSage 7.1. The Continuous cooling transformation diagram of the Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} system was obtained for various cooling rates. The temperatures at which the primary phase formed for various SiO{sub 2} contents and cooling rates differed from the equilibrium temperatures, and the phase-formation temperature ranges varied with the cooling rate. In addition, the reduction degree of each sample was measured to determine the effect of SiO{sub 2} content and cooling rate on the Fe{sub 2}O{sub 3}-CaO-SiO{sub 2} system. The reduction degree in the FeO{sub 3}-CaO-SiO{sub 2} system is dominantly influenced by the SiO{sub 2} bond-phase morphology (CF, C{sub 2}S, C{sub 3}S, or glass) rather than the cooling rate.

36 MATERIALS SCIENCE↗

Effects of Vanadium on Modification of Iron-Rich Intermetallics and Mechanical Properties in A356 Cast Alloys with 1.5 wt.% Fe

Formation of Fe-rich intermetallics and mechanical properties of vanadium-modified A356 cast alloys with 1.5 wt.% Fe were investigated using image analysis, scanning electron microscopy, differential scanning calorimetry, and a tensile test. The results showed that V content has no apparent influence on α-Al grain size in A356 alloys with high Fe content. Also, 0.8 wt.% V is beneficial for improving mechanical properties in A356 cast alloys with high Fe content. Specifically, these results can be attributed to the formation of Chinese script or block α-Fe phases, refined needle-like β-Fe (Al{sub 5}FeSi), and decreased porosities. An excessive amount of V deteriorates mechanical properties of alloys because it leads to VSi{sub 2} formation, large sized iron-rich intermetallics, and increased porosities.

36 MATERIALS SCIENCE↗

Quality Assessment of Al Castings Produced in Sand Molds Using Image and CT Analyses

Nowadays, the economic production of aluminum casts is becoming increasingly important. Therefore, the decision of whether to use alloys based on the primary aluminum (low Fe content, but high costs) or the secondary aluminum (high Fe content, but reasonable costs) for a cast product is a common problem. The main expected influence of higher iron content is to increase porosity and decrease mechanical and fatigue properties. Therefore, this work is focused on assessment of the higher Fe content influence on porosity and iron-rich intermetallic phases formation and, hence, changes in the mechanical properties, with simultaneously keeping the production economical. The quality of castings was measured by application of the 2D technology (image analysis) and the 3D technology (CT analysis), as well. Results show that technologies of assessment are comparable and length of the Fe-rich phases is not critical for mechanical properties, but it is important for porosity formation in materials with the higher amount of Fe.

36 MATERIALS SCIENCE↗

Assessing time-of-flight signal-to-noise ratio gains within the myocardium and subsequent reductions in administered activity in cardiac PET studies

Background: Time-of-flight (TOF) is known to increase signal-to-noise ratio (SNR) and facilitate reductions in administered activity. Established measures of SNR gain are derived from areas of uniform uptake, which is not applicable to the heterogeneous uptake in cardiac PET images using fluoro-deoxyglucose (FDG). This study aimed to develop a technique to quantify SNR gains within the myocardium due to TOF. Methods: Reference TOF SNR gains were measured in 88 FDG oncology patients. Phantom data were used to translate reference SNR gains and validate a method of quantifying SNR gains within the myocardium from parametric images produced from multiple replicate images. This technique was applied to 13 FDG cardiac viability patients. Results: Reference TOF SNR gains of +23% ± 8.5% were measured in oncology patients. Measurements of SNR gain from the phantom data were in agreement and showed the parametric image technique to be sufficiently robust. SNR gains within the myocardium in the viability patients were +21% ± 2.8%. Conclusion: A method to quantify SNR gains from TOF within the myocardium has been developed and evaluated. SNR gains within the myocardium are comparable to those observed by established methods. This allows guidance for protocol optimization for TOF systems in cardiac PET.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of dose reduction in cardiac perfusion SPECT via optimization and choice of the image reconstruction strategy

Background: We investigated the extent to which the administered dose (activity) level can be reduced without sacrificing diagnostic accuracy for three reconstruction strategies for SPECT-myocardial perfusion imaging (MPI). Methods: We optimized the parameters of the three reconstruction strategies for perfusion-defect detection over a range of simulated administered dose levels using a set of hybrid studies (derived from 190 subjects) consisting of clinical SPECT-MPI data modified to contain realistic simulated lesions. The optimized strategies we considered are filtered backprojection (FBP) with no correction for degradations, ordered-subsets expectation-maximization (OS-EM) with attenuation correction (AC), scatter correction (SC), and resolution correction (RC), and OS-EM with scatter and resolution correction only. Each study was evaluated using a total perfusion deficit (TPD) score computed by the Quantitative Perfusion SPECT (QPS) software package. We conducted a receiver operating characteristics (ROC) study based on the TPD scores for each dose level and reconstruction strategy. Results: For FBP, the achieved optimum values of the area under the ROC curve (AUC) at 100%, 50%, 25%, and 12.5% of standard dose were 0.75, 0.74, 0.72, and 0.70, respectively, compared to 0.81, 0.79, 0.76, and 0.74 for OS-EM with AC–SC–RC and 0.78, 0.77, 0.74, 0.72 for OS-EM with SC–RC. Conclusions: Our results suggest that studies reconstructed by OS-EM with AC–SC–RC could possibly be reduced, on average, to 25% of the originally administered dose without causing diagnostic accuracy (AUC) to decrease below that of FBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT

Background: SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Methods: Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of {sup 99m}Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Results: Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image analysis also produced a similar accuracy, sensitivity, and specificity. CFR was normal in 6, each with CAD on SCA with an overall accuracy of 91%, sensitivity of 80%, and specificity of 100%. The mean CFR was significantly lower for SCA detected abnormal than for normal patients (3.86±1.06 vs 1.94±0. 0.67, P < 0.001). Conclusions: The visually assessed image findings in static and dynamic SPECT are subjective, and may not reflect direct physiologic measures of coronary lesion based on SCA. The CFR measured with dynamic SPECT is fully objective, with better sensitivity and specificity, available only with the data generated from the dynamic SPECT method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving perfusion defect detection with respiratory motion correction in cardiac SPECT at standard and reduced doses

Background: In cardiac SPECT perfusion imaging, respiratory motion can cause non-uniform blurring in the reconstructed myocardium. We investigate the potential benefit of respiratory correction with respiratory-binned acquisitions, both at standard dose and at reduced dose, for defect detection and for left ventricular (LV) wall resolution. Methods: We applied two reconstruction methods for respiratory motion correction: post-reconstruction motion correction (PMC) and motion-compensated reconstruction (MCR), and compared with reconstruction without motion correction (Non-MC). We quantified the presence of perfusion defects in reconstructed images by using the total perfusion deficit (TPD) scores and conducted receiver-operating-characteristic (ROC) studies using TPD. We quantified the LV spatial resolution by using the FWHM of its cross-sectional intensity profile. Results: The values in the area-under-the-ROC-curve (AUC) achieved by MCR, PMC, and Non-MC at standard dose were 0.835, 0.830, and 0.798, respectively. Similar AUC improvements were also obtained by MCR and PMC over Non-MC at 50%, 25%, and 12.5% of full dose. Improvements in LV resolution were also observed with motion correction. Conclusions: Respiratory-binned acquisitions can improve perfusion-defect detection accuracy over traditional reconstruction both at standard dose and at reduced dose. Motion correction may contribute to achieving further dose reduction while maintaining the diagnostic accuracy of traditional acquisitions. [French] French Abstract: Contexte: Les mouvements respiratoires peuvent entrainer des artefacts de uniformité lors de la reconstruction des images de perfusion myocardique en SPECT. Dans cet article, nous rapportons nos résultats sur le bénéfice potentiel du « gating » respiratoire avec des doses standards et réduites de radio-pharmaceutiques pour la détection des anomalies de perfusion et les mesures de la paroi ventriculaire gauche. Méthodes: Nous avons appliqué deux méthodes de reconstruction pour la correction du mouvement respiratoire: la première fait appel a une correction après reconstruction des images (PMC) ; la seconde fait appel à la correction des images avant reconstruction (MRC). Les deux approches ont été comparées à la reconstruction sans correction de mouvement (Non-MC). Nous avons quantifié les déficits de perfusion myocardiques sur les images reconstruites avec le système des scores de déficit de perfusion et analysé les résultats en utilisant les courbes ROC. Nous avons quantifié la résolution spatiale du VG en utilisant le FWHM du profil d’intensité de sa section transversale. Résultats: Les valeurs des surfaces en dessous des courbes ROC (AUC) obtenues par MCR, PMC et Non-MC avec doses standard de radio-pharmaceutiques étaient de 0,835, 0,830 et 0,798, respectivement. Des améliorations similaires de l’AUC ont également été obtenues par MCR et PMC sur Non-MC avec 50%, 25% et 12,5% des doses entières. Les mesures de résolution spatiale de la paroi du VG ont également été améliorées avec la correction des mouvements respiratoires. Conclusions: La correction des images de perfusion myocardiques en SPECT par « gating » respiratoire paraît améliorer la quantification des déficits perfusionels à la fois à dose standard et à dose réduite de radio-pharmaceutiques. L’application de cette correction devrait permettre de réduire les doses de radio-pharmaceutiques utilisées tout en maintenant la précision diagnostique des acquisitions traditionnelles. [Spanish] Spanish Abstract: Antecedentes: En los estudios de perfusión cardiaca por SPECT, los movimientos respiratorios pueden causar distorsión no uniforme en el miocardio reconstruido. Investigamos el beneficio potencial de la corrección respiratoria con adquisición de imágenes sincronizadas con la respiración, tanto a dosis estándar como a dosis reducida, para detección de defectos y para resolución de pared de ventrículo izquierdo (VI). Métodos: Aplicamos dos métodos de reconstrucción para corrección de movimientos respiratorios: Corrección de movimiento post reconstrucción (PMC) y reconstrucción compensada a movimiento (MCR), y los comparamos con la reconstrucción sin corrección de movimiento (Non-MC). Cuantificamos la presencia de defectos de perfusión en las imágenes reconstruidas usando los scores de déficit total de perfusión (TPD) y análisis ROC usando el TPD. Cuantificamos la resolución espacial del VI usando la anchura a media altura de su perfil de intensidad transversal. Resultados: Los valores en el área bajo la curva ROC (ABC) obtenidos por MCR, PMC y Non-MC a dosis estándar fueron 0.835, 0.830 y 0.798, respectivamente. Mejorías similares del ABC también se obtuvieron por MCR y PMC, sobre Non-MC a 50%, 25% y 12.5% de la dosis completa. Las mejorías en la resolución del VI fueron observadas también con corrección del movimiento. Conclusiones: Las adquisiciones sincronizadas con la respiración pueden mejorar la precisión de la detección de defectos de perfusión sobre las reconstrucciones tradicionales tanto a dosis estándar como a dosis reducida. La corrección de movimiento puede contribuir a lograr mayor reducción de la dosis manteniendo la precisión diagnóstica de las adquisiciones tradicionales. [Chinese] Chinese Abstract: 背景: 在心脏 SPECT 灌注成像中, 呼吸运动会导致心肌重建的不均匀模糊。我们研究了无论是标准剂量还是减少剂量的情况下, 呼吸跟踪采集的呼吸校正用于图像缺损检测和左心室 (LV) 室壁分辨率的潜在益处。 方法: 我们使用了两种呼吸运动校正的重建方法:重建后运动校正 (PMC) 和运动补偿重建 (MCR), 并与没有运动校正的重建 (Non-MC) 进行比较。 通过总灌注缺损 (TPD) 评分和其接受者操作特性曲线 (ROC) 来量化重建图像中的灌注缺陷。通过LV横截面强度分布的 FWHM来量化 LV 空间分辨率。 结果: MCR, PMC 和 Non-MC 在标准剂量下所获得的 ROC 曲线下面积 (AUC) 的值分别为0.835, 0.830 和 0.798。 在全剂量下, MCR, PMC和 Non-MC也获得类似的 AUC 提高, 分别为 50%, 25% 和 12.5%。 在运动校正下, LV的分辨率也得到了改善。 结论: 在标准剂量和减少剂量的情况下, 呼吸跟踪采集可以改善灌注缺损检测的准确性。 运动校正可能有助于进一步实现减少剂量的目标, 同时保证通过传统检测方法的诊断准确性。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How do we establish cardiac sympathetic nervous system imaging with {sup 123}I-mIBG in clinical practice? Perspectives and lessons from Japan and the US

Cardiac denervation is associated with progressive left ventricular (LV) dysfunction, ventricular arrhythmias, and sudden cardiac death (SCD) in heart failure (HF). In this regard, it is important to evaluate cardiac-specific sympathetic nervous system (SNS) function. The radiotracer Iodine-123 meta-iodobenzylguanidine ({sup 123}I-mIBG) can noninvasively evaluate pre-synaptic SNS function. Recent multicenter trials have shown {sup 123}I-mIBG to have strong predictive value for fatal arrhythmias and cardiac death in HF. {sup 123}I-mIBG was initially developed in the USA in the 1970s. In 1992, the Japanese Ministry of Health and Labour approved {sup 123}I-mIBG for the assessment of cardiac function. Following approval, the Japanese nuclear cardiology community developed {sup 123}I-mIBG imaging services in various medical centers. Japanese groups have been trying to establish the clinical utility of {sup 123}I-mIBG and standardize parameters for data acquisition and image analysis. The US Food and Drug Administration (FDA) has approved clinical use of {sup 123}I-mIBG for cardiac and non-cardiac imaging. However, clinical use of {sup 123}I-mIBG in the US has been very limited. The number of {sup 123}I-mIBG studies in Japan has also been limited. There are similarities and differences between the two countries. To establish the clinical utility of {sup 123}I-mIBG in both countries, it is important to characterize the situations of {sup 123}I-mIBG in each.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

No need for frame-wise attenuation correction in dynamic Rubidium-82 PET for myocardial blood flow quantification

Background: Regadenoson-induced stress causes a repositioning of the heart, myocardial creep, in half of the patients undergoing Rubidium-82 (Rb-82) positron emission tomography (PET). As a result, misalignment of dynamic PET and computer tomography (CT) may occur, possibly affecting CT-based attenuation correction (AC) and thereby PET-based myocardial blood flow (MBF) quantification. Our aim was to determine the need for frame-wise PET-CT AC to obtain reliable MBF measurements. Methods: 31 Out of 64 consecutive patients had myocardial creep during regadenoson-induced stress Rb-82 PET-CT and were included. Prior to PET image reconstruction, we applied two AC methods; single PET-CT alignment and frame-wise alignment in which PET time-frames with myocardial creep were individually co-registered with CT. The PET-CT misalignment was then quantified and MBFs for the three vascular territories and whole myocardium were calculated and compared between both methods. Results: The magnitude of misalignment due to myocardial creep was 13.8 ± 4.5 mm in caudal-cranial direction, 1.8 ± 2.1 mm in medial-lateral and 2.5 ± 1.8 mm in anterior-posterior direction. Frame-wise PET-CT registration did not result in different MBF measurements (P ≥ .07) and the magnitude of misalignment and MBF differences did not correlate (P ≥ .58). Conclusion: There is no need for frame-wise AC in dynamic Rb-82 PET for MBF quantification. Single alignment seems sufficient in patients with myocardial creep.

62 RADIOLOGY AND NUCLEAR MEDICINE↗