At least 505 records · Page 28

All-electron, density-functional-based method for angle-resolved tunneling ionization in the adiabatic regime

Here we develop and test a method that integrates many-electron weak-field asymptotic theory (ME-WFAT) [O. I. Tolstikhin, L. B. Madsen, and T. Morishita, Phys. Rev. A 89, 013421 (2014)] in the integral representation (IR) into the density-functional-theory (DFT) framework. In particular, we present modifications of the integral formula in the IR ME-WFAT to incorporate the potential terms unique to DFT. By solving an adiabatic rate equation for the angle-resolved ionization yield in our DFT-based ME-WFAT method, we show that the results are in excellent agreement with those of real-time time-dependent density-functional-theory (TDDFT) simulations for NO, OCS, C⁢H 3 ⁢Br, and C⁢H 3 ⁢Cl interacting with one- and two-color laser fields with a fundamental wavelength of 800 nm. This agreement is significant because the WFAT calculations take only a small fraction of the time of full TDDFT calculations. These results suggest that in the wavelength region commonly used in strong-field experiments (800 nm and longer), our DFT-based WFAT treatment can be used to rapidly screen for the ionization properties of a large number of molecules as a function of alignment or orientation between the molecule and the strong field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HydraGNN 2.0

HydraGNN is an Oak Ridge National Laboratory (ORNL)-branded implementation of distributed multi-tasking graph neural networks that supports several scientific applications within the ORNL portfolio to support the US-DOE mission. New or improved capabilities included in v2.0.0 release are as follows: 1) Enhancement in message passing layers through class inheritance 2) Adding transformation to ensure translation and rotation invariance 3) Supporting various optimizers 4) Atomic descriptors 5) Integration with continuous CI test 6) Distributed printouts and timers 7) Profiling 8) Support of ADIOS2 for scalable data loading 9) Large-scale system support, including Summit (ORNL) and Perlmutter (NERSC)

Lupo Pasini, Massimiliano [Oak Ridge National Labo↗

Theory of In-Cloud Activation of Aerosols and Microphysical Quasi-Equilibrium in a Deep Updraft

The microphysical quasi-equilibrium in an ascending adiabatic parcel is elucidated by an analytical theory in 0D with drastic simplifications. The theory predicts how in-cloud activation is most likely to be triggered by the onset of precipitation during sufficient ascent, with the ascent only needing to approach almost twice the cloud-base updraft speed aloft. The precipitation and cloud condensate mass fields are coupled in a closed system in a simplified version of the model. The initial state of no precipitation is unstable with respect to a perturbation. In the 2D phase space of both mass fields, there is a neutral line. Unstable growth of precipitation mass drives the system to cross the line into a regime of stability. An attractor is then approached consisting of precipitation mass balanced by accretion of cloud mass and fallout. The cloud-particle number concentration also approaches a stable equilibrium governed by the balance between in-cloud activation aloft from the inexorably increasing supersaturation during vertical acceleration and accretion of cloud droplets by precipitation. Dimensionless numbers characterizing the microphysical equilibria and their stability are derived mathematically, including a condensation–precipitation efficiency and an in-cloud activation efficiency. The theory explains common observations of the orders of magnitude of liquid water content in convective and stratiform clouds. Finally, sensitivity tests of the numerically integrated theoretical equations are documented with respect to variations in cloud condensation nucleus (CCN) aerosols and updraft speed. In conclusion, it is shown that this theory of in-cloud activation, with an increasing supersaturation during ascent, applies to both ice-only and liquid-only cloud.

54 ENVIRONMENTAL SCIENCES↗

Mechanical and Thermophysical Properties of 3D-Printed SiC-FY20

In the Transformational Challenge Reactor (TCR), the fuel blocks consist of an additively-manufactured silicon carbide (SiC) matrix and uranium nitride tristructural isotropic (UN TRISO) fuel particles, which are stacked to form fuel columns. The SiC matrix is manufactured using binderjet 3D printing followed by loading the TRISO fuel particles and the chemical vapor infiltration (CVI) process. Because the fuel matrix is a primary component of the TCR core and its response to mechanical and thermal loads during operation is one of the most influential factors on the integrity of TCR core, testing and evaluation have focused on producing mechanical and thermophysical properties data for the binderjet/CVI SiC. Mechanical and thermophysical properties were measured from various types of specimens printed for two or three orientations, which included equibiaxial flexural failure strength, elastic constants, thermal diffusivity and conductivity, density, and the coefficient of thermal expansion. Flexural failure strength datasets showed similar Weibull distributions regardless of sample variants including different orientations. The mean failure strengths of the 3D-printed SiC variants were in the range of 286–306 MPa, which are 22–27% lower than that of the CVD SiC. Thermophysical test results showed that specific heat and thermal expansion are not sensitive to the build directions of SiC samples, while thermal diffusivity is highly dependent on the build direction and can be correlated to the anisotropic character of the 3D-printed SiC. This report also includes discussions on the uniaxial tensile properties of the as-printed SiC before CVI and on ongoing efforts for irradiation effects studies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mechanical and Thermophysical Properties of 3D-Printed SiC before and after Neutron Irradiation – FY21

This report presents the mechanical and thermophysical properties of 3D-printed SiC before and after neutron irradiation that have been evaluated to assess the fuel matrix material for the Transformational Challenge Reactor (TCR). The TCR fuel form consists of an additively-manufactured silicon carbide (SiC) matrix and uranium nitride tristructural isotropic (UN TRISO) fuel particles, which is manufactured through a newly developed processing route combining binderjet 3D printing, TRISO fuel particle loading, and chemical vapor infiltration (CVI). Because the fuel matrix is a primary component of the TCR core and its response to mechanical and thermal loads during operation is one of the most influential factors on the integrity of TCR core, testing and evaluation have focused on producing mechanical and thermophysical properties data for the binderjet/CVI SiC. Baseline mechanical and thermophysical properties were measured from the disk specimens printed for different and sizes orientations, which included equibiaxial flexural failure strength, elastic constants, thermal diffusivity and conductivity, density, and the coefficient of thermal expansion. Flexural failure strength datasets showed similar Weibull distributions regardless of sample variants including different orientations. The mean failure strengths of the 3D-printed SiC variants were in the range of 280–310 MPa, which are slightly lower than that of the chemical vapor deposition (CVD) SiC. Thermophysical test results showed that specific heat and thermal expansion are not sensitive to the build direction of SiC samples, while thermal conductivity is highly dependent on the build direction and can be correlated to the anisotropic character of the 3D-printed SiC. Neutron irradiation tests were carried out on the 3D-printed 6-mm diameter SiC disk specimens. Irradiation was carried to 2.3 dpa over a temperature range of 360–880°C. No significant degradation in strength was observed in SiC after irradiations in various conditions and with different orientations. Anisotropy that had been observed in the thermal conductivity of 3D-printed SiC prior to irradiation vanished after irradiation as the irradiation defect thermal resistivity accumulated in the material. Electron microscopy of the microstructure after neutron irradiation showed distinct defect morphologies in the heterogenous material, but no evidence for irradiation-induced cracking or degradation in the microstructure was observed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NREL's HydroGEN Photoreactor Platform Design and Characterization

This technical report details the design, fabrication, and construction of a flow-through photoreactor developed at The National Renewable Energy Laboratory (NREL). The photoreactor is designed to facilitate indoor or outdoor testing on photoelectrochemical or integrated solar water splitting devices. The photoreactor design described here is based on a previous demonstration. The photoreactor version described herein contains several advanced design features that include: 1) Chassis-chuck two-part design, 2) Separable counter electrode compartments (here, the counter electrodes are anodes), 3) Reduced electrode separation to reduce electrolyte resistance, 4) Improved flow pattern for bubble removal, 5) Mounting for spectroradiometer receptor, 6) Fresnel lens and collimating tube attachments. The photoreactor presented here was designed primarily to accommodate photocathode materials in an illuminated compartment and a dark anode as the oxygen evolution catalyst. The build materials were thus chosen to for acid electrolyte compatibility. Other embodiments could accommodate a photoanode with dark hydrogen evolution catalyst and other build materials for alkaline compatibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Representative-cell-based Modeling of HTTF in SAM

Although the current nuclear power market is primarily occupied by the light water reactors (LWRs), the TRISO-fueled helium-cooled graphite-moderated high temperature gas reactors (HTGRs) are drawing growing attention as the nuclear power industry marches towards more advanced systems. Compared to that of conventional LWRs, the thermal hydraulics of HTGR cores show extra complexity from their multi-scale heat transfer mechanisms with varying importance during different operation modes or transient stages. The modeling of HTGR cores for the system analysis purpose therefore faces the challenge of reaching reasonable fidelity and accuracy while maintaining sufficient simplicity. Previous development and validation efforts have demonstrated that a “2-D ring model” with reasonable performance can be implemented in the System Analysis Module (SAM) for prismatic HTGR cores. In the current project, an alternative modeling methodology based on “representative cells” is proposed for the typical prismatic core of HTGRs. Different from the previous ring model approach, the proposed methodology first separately models and then combines the small- and large-scale thermal conductions, by connecting representative local heat transfer units (cells) with effective core- wise thermal resistance. A modeling practice for an integral high-temperature test facility (HTTF) elaborates the modeling details. Steady-state validation of the resultant candidate model is performed against a higher-resolution benchmark from a 3D-1D coupled simulation, which shows satisfactory prediction with reasonably captured global parameters and well-represented temperature fields. A postulated pressurized conduction cooldown (PCC) is also simulated and analyzed, demonstrating the model’s capability of transient prediction with physically captured phenomena resolved in both small and large temporal and spatial scales. In general, the current work achieves a preliminary success in proposing a methodology using representative cells to model prismatic HTGR cores in SAM. Future efforts are envisioned with more validation activities and with potential modeling improvements to eventually achieve the high confidence on a high-fidelity robust modeling methodology with reasonable accuracy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FAUST - Benchmark and Validation Framework [Slides]

This presentation discusses Python packages for nuclear data applications and for benchmarking. It also discusses the goals and objectives for FAUST which include providing input and output processing for different calculation codes, allowing for exchanging results between different applications and codes, running benchmarks and processing the results, automating and simplify plot and report generation, and providing a basis for developing applications useful for nuclear data evaluators. The presentation also discusses how the packages can be used both inside and outside LANL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermopile Energy Harvesting for Subsurface Wellbore Sensors (Final Report)

Robust in situ power harvesting underlies all efforts to enable downhole autonomous sensors for real-time and long-term monitoring of CO 2 plume movement and permeance, wellbore health, and induced seismicity. This project evaluated the potential use of downhole thermopile arrays, known as thermoelectric generators (TEGs), as power sources to charge sensors for in situ real-time, long-term data capture and transmission. Real-time downhole monitoring will enable “Big Data” techniques and machine learning, using massive amounts of continuous data from embedded sensors, to quantify short- and long-term stability and safety of enhanced oil recovery and/or commercial-scale geologic CO 2 storage. This project evaluated possible placement of the TEGs at two different wellbore locations: on the outside of the casing; or on the production tubing. TEGs convert heat flux to electrical power, and in the borehole environment, would convert heat flux into or out of the borehole into power for downhole sensors. Such heat flux would be driven by pumping of cold or hot fluids into the borehole—for instance, injecting supercritical CO 2 —creating a thermal pulse that could power the downhole sensors. Hence, wireless power generation could be accomplished with in situ TEG energy harvesting. This final report summarizes the project’s efforts that accomplished the creation of a fully operational thermopile field unit, including selection of materials, laboratory benchtop experiments and thermal-hydrologic modeling for design and optimization of the field-scale power generation test unit. Finally, the report describes the field unit that has been built and presents results of performance and survivability testing. The performance and survivability testing evaluated the following: 1) downhole power generation in response to a thermal gradient produced by pumping a heated fluid down a borehole and through the field unit; and 2) component survivability and operation at elevated temperature and pressure conditions representative of field conditions. The performance and survivability testing show that TEG arrays are viable for generating ample energy to power downhole sensors, although it is important to note that developing or connecting to sensors was beyond the scope of this project. This project’s accomplishments thus traversed from a low Technical Readiness Level (TRL) on fundamental concepts of the application and modeling to TRL-5 via testing of the fully integrated field unit for power generation in relevant environments. A fully issued United States Patent covers the wellbore power harvesting technology and applications developed by this project.

47 OTHER INSTRUMENTATION↗

Integrating PCTRAN with AI-Driven Host-Intrusion Detection and Secured Container Systems for Advanced Malware Analysis (Summer Internship Report)

This study presents a solution for enhancing the security of the Personal Computer Transient Analyzer (PCTRAN) PC-based Nuclear Power Plant Simulator by integrating the software with an artificial intelligence (AI)-driven host-intrusion detection system (HIDS), in addition to a secured container system, for malware analysis. PCTRAN is a Windows XP-based software package that has the ability to simulate a variety of accident and transient conditions for nuclear power plants (NPPs). It offers a high-resolution replica of the Nuclear Steam Supply System (NSSS) and displays the status of important parameters allowing for operator interaction. By including AI-driven HIDS for the NSSS, the framework can identify security threats in real-time, ensuring the integrity of the nuclear simulation environment. Additionally, the secured container system offers the ability to isolate and analyze malware, preventing potential threats from affecting core systems. The integration process involves extensive testing and validation in order to ensure accuracy, reliability, and compliance with security policies. This framework sets a new precedent for secure simulation and training in NPP operations, and offers insight for future advancements in cybersecurity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electro-Thermo-Mechanical (ETM) Study on Submarine Dynamic Power Cables (SDPC) for Offshore Wind Transmission

Understanding the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project conducted a systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15kV power cable with three cores of copper conductor, ethylene propylene rubber (EPR) insulation, and continuously corrugated welded aluminum armor (CCWA). An ETM testing system was developed by integrating a high voltage (HV) amplifier, two ceramic heaters, and a rod-plate transverse compression setup into a mechanical testing machine. Increasing temperature from room temperature (RT, 22 degree C) to 90 degree C resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. Under creep mechanical loading, the dielectric breakdown time was decreased by 70% for a given mechanical load when the specimen temperature increased from RT to 90oC. The failure strain in both monotonic and creep mechanical loading modes was related to the maximum mechanical load applied. Although the dielectric breakdown occurred in the ETM test, the post-test measurement revealed an impressive recovery of electric resistance. The failure analysis on cross section of tested specimens indicated a sizable gap across insulation layer near the area between copper conductor and loading rod, which apparently resulted from online dielectric failure and offline elastic recovery of components including conductor and insulation layer.

17 WIND ENERGY↗

Corroborative Evaluation of the Real-World Energy Saving Potentials of InfoRich Eco-Autonomous Driving (iREAD) System

There has been an increasing interest in exploring the potential to reduce energy consumption of future connected and automated vehicles. People have extensively studied various eco-driving implementations that leverage preview information provided by on-board sensors and connectivity, as well as the control authority enabled by automation. Quantitative real-world evaluation of eco-driving benefits is a challenging task. The standard regulatory driving cycles used for measuring exhaust emissions and fuel economy are not truly representative of real-world driving, nor for capturing how connectivity and automation might influence driving trajectories. To adequately consider real-world driving behavior and potential “off-cycle” impacts, this paper presents four collaborative evaluation methods: large-scale simulation, in-depth simulation, vehicle-in-the-loop testing, and vehicle road testing. These four approaches, spanning simulation and testing aspects, evaluate real-world fuel economy benefits with different ranges and resolutions. The large-scale simulations leverage an extensive real-world driving database to assess overall eco-driving benefits across a range of road network and driving scenarios. The real-world driving data are further leveraged to generate representative driving routes for deeper evaluation. Based on the representative routes, in-depth simulation relying on high-fidelity models investigates how different traffic scenarios can impact the eco-driving performance. The vehicle-in-the-loop setup reinforces the in-depth simulations by conducting tests with an actual vehicle operated on a chassis dynamometer; the measured energy savings were indeed found to agree with the in-depth simulation savings estimates. Finally, limited but representative road testing with the fully integrated vehicle will be conducted to demonstrate the eco-driving capability and conclude the overall evaluation regimen.

ARPA-E↗

Battery inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 30 kW off-the-shelf grid following battery inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

National Reactor Innovation Center Annual Report FY 2023

It is my privilege to present this year’s annual report for the National Reactor Innovation Center (NRIC). Now rounding out our fourth year of operation, NRIC is poised for successfully delivering our most foundational promise: to accelerate the testing and demonstration of advanced nuclear technology by providing access to national laboratory assets and expertise. Some specific goals include: • Establish and maintain four new experimental facility capabilities: o MSTEC – 2025 o METL – Operational o HeCTF – Operational o Creep Frames – 2026 • Construct and operationalize two advanced reactor test beds (DOME and LOTUS) for integrated technology demonstrations and experimentation – 2028 • Complete minimum of two advanced nuclear technology tests – 2030 o Advanced Construction Technology – 2025 o Advanced Microreactor test in DOME or LOTUS – 2027 & 2029

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Continental Scale Hydrostratigraphy: Basin‐Scale Testing of Alternative Data‐Driven Approaches

Abstract Integrated hydrological modeling is an effective method for understanding interactions between parts of the hydrologic cycle, quantifying water resources, and furthering knowledge of hydrologic processes. However, these models are dependent on robust and accurate datasets that physically represent spatial characteristics as model inputs. This study evaluates multiple data‐driven approaches for estimating hydraulic conductivity and subsurface properties at the continental‐scale, constructed from existing subsurface dataset components. Each subsurface configuration represents upper (unconfined) hydrogeology, lower (confined) hydrogeology, and the presence of a vertical flow barrier. Configurations are tested in two large‐scale U.S. watersheds using an integrated model. Model results are compared to observed streamflow and steady state water table depth (WTD). We provide model results for a range of configurations and show that both WTD and surface water partitioning are important indicators of performance. We also show that geology data source, total subsurface depth, anisotropy, and inclusion of a vertical flow barrier are the most important considerations for subsurface configurations. While a range of configurations proved viable, we provide a recommended Selected National Configuration 1 km resolution subsurface dataset for use in distributed large‐and continental‐scale hydrologic modeling.

54 ENVIRONMENTAL SCIENCES↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗