Search NASA⌕ Search

SEARCH · Search NASA

Results for “Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Apparatus for providing a servo drive signal in a high-speed stepping interferometer

An analog voltage approximately linearly proportional to a desired offset from the present null position of a moving mirror in an interferometer is applied to the mirror moving means. As the mirror moves to the next null position, as determined by the analog voltage, the fringes of a laser reference interference pattern are detected. At the occurrence of each fringe the analog voltage is reduced proportionally so that when the next null position is reached, this driving analog is effectively zero. A binary up/down counter, by its internal count, causes a digital/analog converter to supply the analog voltage to the mirror moving means. Fringe detection and direction of movement logic cause the binary up/down counter to be decremented from its offset count as the mirror is moved to the new null position. Undesirable movement of the mirror due to vibration or other sources causes a correcting drive signal to be applied to the mirror moving means that is proportional to the distance of movement.

Schindler, R. A.↗

Miniature interferometer terminals for earth surveying

A system of miniature radio interferometer terminals was proposed for the measurement of vector baselines with uncertainties ranging from the millimeter to the centimeter level for baseline lengths ranging, respectively, from a few to a few hundred kilometers. Each terminal would have no moving parts, could be packaged in a volume of less than 0.1 cu m, and would operate unattended. These units would receive radio signals from low-power (10 w) transmitters on earth-orbiting satellites. The baselines between units could be determined virtually instantaneously and monitored continuously as long as at least four satellites were visible simultaneously.

Counselman, C. C., III↗

CIMATS - A correlation interferometer for the measurement of atmospheric trace species

A multigas correlation interferometer, based on the previously developed and tested COPE instrument, has been designed and fabricated and is presently undergoing laboratory testing. The CIMATS instrument has the capability to remotely measure densities of selected gaseous atmospheric species in the spectral range 2 to 2.5 and 4 to 10 microns. The sensor has been designed for both nadir viewing and earth limb viewing. As presently configured the sensor is capable of measuring ammonia, nitrous oxide, and carbon monoxide in the nonthermal infrared spectral region and carbon monoxide and sulfur dioxide in the thermal infrared. Other gaseous species can be measured by inclusion of additional narrow band filters.

Goldstein, H. W.↗

Satellite interferometer as an advanced navigation/communication system

An orthogonal system of interferometry baselines aboard a geostationary satellite is proposed to be used for navigation, surveillance, and traffic control. Position determination is based on the relationship between the measured phase differences, the known and unknown transmitter locations, and other systematic error model parameters using a generalized least-squares estimation procedure. It is shown that position accuracy is critically dependent on the baseline length and on the magnitude of the random component of the measuring errors. Several trade-offs with respect to the system accuracies, the number of users, data rates, hardware costs, etc., are examined. Simultaneous use of the same channels for navigation and data transfer is found feasible and five candidate or 'strawman' interferometer system proposals are presented. It is concluded that the system's performance is excellent in comparison with present or planned systems, and that it is viable in meeting potential user's requirements.

Gopalapillai, G. S.↗

Description of the ISEE satellite-to-satellite kilometric wavelength interferometer system

The International Sun-Earth Explorer (ISEE) spacecraft 1 and 2 carry receivers for detecting electromagnetic waves with kilometric wavelengths. For selected receiver frequencies from 30 kHz to 2 MHz, a 10-kHz bandwidth channel is single-sideband mixed down to baseband. These analog data and a reference frequency, which is a submultiple of the local oscillator frequency, are transmitted to ground stations and tape recorded along with the precise time and frequency information. Cross correlation of these tape recorded signals constitutes a satellite-to-satellite interferometer with a fringe spacing of 0.4 to 41 arcmin (at a range of 10,000 to 100 km spacing between spacecraft for 250 kHz in frequency) and with a time-delay resolution of 32 microsec for a 10-kHz bandwidth, which gives an angular resolution of 3 min to 6 deg of arc. For kilometric radiation at earth, sources in the size range of 25 to 2500 km can be identified (from 20 earth radii) and located in relative position ranging from 0.02 to 2 earth radii, depending on spacecraft spacing. Reception and analysis of solar and Jovian bursts may also be possible.

Shawhan, S. D.↗

The USNO/NRL Green Bank interferometer program

Application of the connected-element radio interferometer of the National Radio Astronomy Observation in Green Bank, West Virginia to the determination of improved source coordinates, astronomical constants, and variations in Earth rotation parameters is discussed. It is concluded that because of the brevity and discontinuity of the data so far no reliable conclusions regarding the accuracy of the data can be drawn.

Klepczynski, W. J.↗

Phase and group delay calibration of a very long baseline interferometer by East Coast VLBI Group

Precisely timed pulses injected into the input of each receiver are used to calibrate the phase and group delay through each interferometer terminal. The short duration pulses are generated at a 1 MHz rate directly from the output of the frequency standard. The pulses are injected into the receiver at a level low enough to produce less than one percent increase in system temperature, yet can be extracted during processing with a high enough signal to noise ratio to determine the phase of the calibration rails within 1 degree in 1 second of integration. The calibration system also includes precise cable measurement electronics and a pulse echo for clock synchronization.

Rogers, A. E. E.↗

The sensitivity of a very long baseline interferometer

The theoretical sensitivity of various methods of acquiring and processing interferometer data are compared. It is shown that for a fixed digital recording capacity one bit quantization of single sideband data filtered with a rectangular bandpass and sampled at the Nyquist rate yields the optimum signal to noise ratio. The losses which result from imperfect bandpass, poor image rejection, approximate methods of fringe rotation, fractional bit correction, and loss of quadrature are discussed. Also discussed is the use of the complex delay function as a maximum likelihood fringe estimator.

Rogers, A. E. E.↗

Accurate radio positions with the Tidbinbilla interferometer

The Tidbinbilla interferometer, designed specifically to provide accurate radio position measurements of compact radio sources in the Southern Hemisphere with high sensitivity using the 26 m and 64 m antennas of the Deep Space Network at Tidbinbilla, near Canberra, is discussed. The instrument also provides high accuracy flux density measurements for compact radio sources.

Batty, M. J.↗

Portable high-resolution laser monochromator-interferometer with multichannel electronic readout

A high-resolution 0.4-m monochromator is described for use in wavelength diagnosis of tunable pulsed and CW laser sources in the 3000-10,000-A region. The f/20 design uses an echelle grating in an over-and-under Ebert configuration with a scanned photodiode array to provide a real-time multichannel display of spectral output. Absolute wavelength may be determined to 0.1 A with the monochromator, and a Fabry-Perot interferometer attachment extends linewidth measurement capability to 0.01 A or better. Spectra are displayed on a storage oscilloscope, and calculation of laser parameters is explained. The instrument measures 70 cm long x 15 cm wide x 20 cm high.

Morris, M. B.↗

Fabry-Perot-interferometer imaging system for thermospheric temperature and wind measurements

Doppler-broadened Fabry-Perot fringes of weak (less than 1-kR) auroral forbidden O I 5577- and 6300-A emissions have been detected in real time (1/60 sec) with the aid of a low-light level image-orthicon TV camera coupled to a two-stage image intensifier. The imaging scheme permits static-mode operation of a Fabry-Perot interferometer. For maximum use of all the information contained in every TV frame, each circular fringe may be sectioned into several annuli, and the corresponding annuli from all rings are summed to yield an intensity value. This procedure for deriving a fringe profile requires a video digitizer coupled to a digital processing system and should provide fast real-time (1/60 sec) measurements of E- and F-region temperatures and winds. With forbidden O I 5577-A intensity of 750 R, visually prominent TV images of the Fabry-Perot fringes were recorded in 0.5 sec, and the temperature of the emitting region was determined from two percent of the total information in the TV image.

Sivjee, G. G.↗

Wide angle Michelson Doppler imaging interferometer

The optical system, stepping control, phase and modulation depth, array detector, and directions sensor are described for a specialized type of Michelson interferometer which works at sufficiently high resolution to measure the line widths and Doppler shifts of naturally occurring atmospheric emissions. With its imaging capability, the instrument can potentially supply this data independently for each element of the 100 x 100 detector array. The experiment seeks: (1) to obtain vertical profiles of atmospheric winds and temperatures as functions of latitude by observing near the limb; (2) to acquire exploratory wind and temperature data on smaller scale structures in airglow irregularities and in auroral forms; and (3) to collaborate with other Spacelab experiments, such as barium cloud releases, in providing wind and temperature data.

Shepherd, G. G.↗

Systems level feasibility study for the detection of extra-solar planets. Volume 1: Infrared interferometer (IRIS) known as the Stanford Concept

A sensor system for the direct detection of extrasolar planets from an Earth orbit is evaluated: a spinning, infrared interferometer (IRIS). It is shuttle deployed, free flying, requires no on-orbit assembly and no reservicing over a design life of five years. The sensor concept and the mission objectives are reviewed, and the performance characteristics of a baseline sensor for standard observation conditions are derived. A baseline sensor design is given and the enabling technology discussed. Cost and weight estimates are performed; and a schedule for an IRIS program including technology development and assessment of risk are given. Finally, the sensor is compared with the apodized visual telescope sensor (APOTS) proposed for the same mission. The major conclusions are: that with moderate to strong technology advances, particularly in the fields of long life cryogenics, dynamical control, mirror manufacturing, and optical alignment, the detection of a Jupiter like planet around a Sunlike star at a distance of 30 light years is feasible, with a 3 meter aperture and an observation time of 1 hour. By contrast, major and possibly unlikely breakthroughs in mirror technology are required for APOTS to match this performance.

Source record↗

Preliminary design of the cryogenic cooled limb scanning interferometer radiometer (CLIR)

The preliminary design of the cryogenic cooling system for the Cryogenic Cooled Limb Scanning Interferometer Radiometer (CLIR) instrument to be flown on the Atmospheric Magnetospheric Physics Satellite (AMPS) was studied. The top level trade studies were extensive due to the instrument requirement for cooling at three temperature levels as opposed to the two levels initially described for the instrument. Approximately 12 different combinations of cryogens were investigated. The basic lifetime requirement for the instrument was 30 days. However, studies were also conducted for a follow-up mission requiring a 1 year lifetime. The top level trades led to the selection of a single stage supercritical helium baseline.

Sherman, A.↗

Vacuum ultraviolet Mach-Zehnder interferometer with CaF2 optics

CaF2 beam splitters and compensation and test cell windows have been installed in a VUV Mach-Zehnder interferometer. Results of an evaluation of their performance in the VUV, namely, a measurement of the oscillator strength (f value) of the resonance transition at atomic xenon at 146.9610 nm are reported.

Smith, P. L.↗

Planetary observations with the Tidbinbilla interferometer

Radio observations at a wavelength of 13.1 cm of Saturn and Uranus made with the Tidbinbilla interferometer during 1978 and 1979 are summarized. The observations were made with 64-m and 26-m antennas on a 200-m north-south baseline at a bandwidth of 12 MHz with RCP polarization and a primary beamwidth of about 12 arcmin. A flux density of 198 + or - 15 mJy was measured for Saturn, which indicates a surface temperature, corrected for the occulting effect of the rings, of 191 + or - 15 K, in excellent agreement with previous determinations. With the use of a background subtraction technique to remove the local background confusion, Uranus was found to have a flux density of 11.7 + or - 0.8 mJy, indicating a disk-averaged brightness temperature of 255 + or - 18 K. The increase in Uranus brightness temperature over that measured 15 years previously is attributed to variations in temperature or opacity below the cloud tops, or to a reduction in relative ammonia abundance most likely reflecting a change in the aspect of the planet as viewed from earth.

Batty, M. J.↗

Optical fiber interferometer for the study of ultrasonic waves in composite materials

The possibility of acoustic emission detection in composites using embedded optical fibers as sensing elements was investigated. Optical fiber interferometry, fiber acoustic sensitivity, fiber interferometer calibration, and acoustic emission detection are reported. Adhesive bond layer dynamical properties using ultrasonic interface waves, the design and construction of an ultrasonic transducer with a two dimensional Gaussian pressure profile, and the development of an optical differential technique for the measurement of surface acoustic wave particle displacements and propagation direction are also examined.

Claus, R. O.↗

DC calibration of the strain sensitivity of a single mode optical fiber interferometer

The strain sensitivity of an optical fiber interferometer developed for the detection of pulsed ultrasonic waves in solids was calibrated. Light from the output ends of both fibers was superimposed to form an interference fringe pattern that was interrogated in the far field to give a signal proportional to the differential optical fiber path length. Strain sensitivity is determined by comparing data obtained by clamping and bending the bar at different lengths to simple cantilever beam theory. A minimum theoretical detectable strain of less than 10 to the minus 10th power is indicated.

Claus, R. O.↗