Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOADS - DISKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Agrivoltaic Racking Design Optimization Based on Wind and Snow Loading Finite Element Analysis

The racking structure of photovoltaic (PV) systems plays a critical role in ensuring the PV panels generate power properly as it provides integral structural support and sometimes even solar tracking ability. Distinct applications of PV systems require variations of racking structure designs, which yield different mechanical performances under external loading conditions from the environment, such as heavy wind and snow. Past works, such as Reddy et al. [1], have analyzed the pressure effects of wind and snow loading on the racking structure of conventional rooftop and utility PV systems, but there is little knowledge of how various agrivoltaic racking systems perform, in terms of stress and strain, under the same loading conditions. There is also a knowledge gap in the industry on a set of optimized agrivoltaic racking design standards. This study investigates the mechanical performance of various existing racking systems and proposes novel designs that are optimized for agrivoltaics applications under wind and snow loading.

Liao, Quanhuan↗

Factorization Machine Learning for Disaggregation of Transmission Load Profiles with High Penetration of Behind-the-Meter Solar

The ever-growing high penetration of ubiquitously distributed energy resources, especially behind-the-meter solar (BTM) generations, has significant impacts on nodal load (i.e., net injection) profiles and consequently caused imperative operational challenges to system operators such as regional transmission organizations (RTOs). Illustrated by real-world nodal data and examples at PJM Interconnection, this paper first discusses the application and necessity of effectively extracting daily nodal load profiles in a non-intrusive manner. More importantly, a novel bi-level architecture, including Factorization Machines (FM) learning procedure has been proposed to effectively disaggregate not only one node but every node in an RTO service territory. Specifically, FM leaning is adopted to capture the interconnections between related features to better utilize the correlation between buses in the same region and between a single bus and the zonal load. The proposed bi-level technique is numerically validated using real-world, minute-level, normalized, and anonymized nodal data at PJM service territory.

behind the meter solar, load disaggregation, load ↗

Field Demonstration of Residential DER Service-Oriented Load Participation

Amidst a concerning surge in power consumption during peak hours, coupled with heightened power grid instability, and driven by a growing demand for electricity, aggregations of Distributed Energy Resource are becoming a viable means for providing essential reliability services.Electric utility companies have proactively implemented Demand Response programs for decades. These programs employ Direct Load Control methods to enhance power grid stability, achieved by controlling customers’ Distributed Energy Resource during peak hours to reduce power consumption. However, a notable drawback of Direct Load Control has been high unenrollment rates of DR program participants due to customer discomfort.Therefore, the underlying issue of over-consumption persists. To address these concerns, this paper introduces a Service-Oriented Load Participation approach to providing grid services such as Demand Response. Leveraging a Service-Oriented Architecture, this method offers the advantage of efficient service management and provisioning within the system. The SOLP approach not only aims to reduce power consumption but also to maintain customer satisfaction by ensuring a comfortable grid service experience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Policy and Cost Allocation Considerations for Large Electric Load Interconnections: Emerging Policy Trends in Rate Structures, Interconnection, and Cost Impacts on Other System Users

Load growth in the United States is rapidly increasing: load from data centers alone has tripled over the past decade, and this growth is forecasted to continue accelerating. These and other large electric loads (LELs) promise economic benefits at the state and local level, but their deployment has also led to increasing concerns about grid impacts and potential cost shifts onto other ratepayers. Legislators, regulators, and other stakeholders are increasingly proposing and enacting policies in effort to balance these and other considerations. This white paper reviews state-level legislation, selected utility rate cases, and relevant federal orders in an effort to describe and categorize relevant trends in policies related to LEL cost allocation, interconnection, and deployment. Policy categories identified through this review include tax incentives, rate actions, and requirements related to interconnection, permitting, and reporting. By offering a taxonomy of policies, this white paper aims to offer a resource to policymakers and other stakeholders navigating this transformative moment for the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing and Reducing Plug and Process Loads in Office Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗

Assessing and Reducing Plug and Process Loads in Retail Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation and the results have proved the effectiveness of this method.

AMI↗

Operando Neutron Imaging of Lithium Flux and Gradient Cathode Design for Enhanced Kinetics in High‐Loading All‐Solid‐State Li─S Batteries

All-solid-state Li–sulfur batteries (ASSLSBs) are considered promising candidates for next-generation energy storage owing to their inherent safety, high energy density, and abundant sulfur resources. However, slow redox kinetics greatly limit sulfur utilization during solid-solid sulfur reactions, leading to significant challenges to achieve efficient performance in high-mass-loading ASSLSBs. Here, operando neutron image is employed to directly visualize, for the first time, that sluggish Li + transport kinetics and the uneven distribution of Li + during cathodic reactions are critical factors limiting sulfur conversion. To address this issue, gradient cathode architectures comprising three and five layers are designed, in which catholyte concentrations are strategically varied to optimize Li-ion flux and enhance ionic conductivity of the whole composite cathode electrode. Operando neutron imaging distinctly visualizes and confirms that three-layer gradient approach significantly enhances Li-ion mobility, resulting in more uniform redox reactions and greatly improved sulfur utilization compared to traditional non-gradient structures. Consequently, the three-layer gradient cathode achieves superior rate performance and reduced electrode polarization at high sulfur mass loadings of 4.5 and 6.0 mg cm −2 . Furthermore, the applicability and scalability of this design are demonstrated in a five-layer gradient cathode architecture, achieving an impressive discharge specific capacity increase from 656 mAh g −1 (three-layer gradient) to 1232 mAh g −1 at 1/20 C for ultra-high sulfur loading of 7.5 mg cm −2 . In conclusion, this innovative gradient cathode design offers substantial advancements in understanding and overcoming Li-ion transport limitations, paving the way toward practical, high-energy-density ASSLSBs.

25 ENERGY STORAGE↗

Ultrathin Microporous Transport Layers: Implications for Low Catalyst Loadings, Thin Membranes, and High Current Density Operation for Proton Exchange Membrane Electrolysis

Porous transport layers (PTL) and their surface properties have the potential to improve the performance of proton exchange membrane water electrolyzers (PEMWE), which is imperative to reduce feedstock costs and lead to their widespread implementation. This work introduces a novel generation of titanium microporous layers (MPLs) with ultra-low thicknesses of approx. 20 um which reduces raw material costs. They also feature advanced interfacial properties tailored to maximize catalyst utilization at low Ir-loadings. The bulk morphology and surface properties of the hierarchically structured PTLs are assessed by X-ray tomographic microscopy. The low surface roughness of the MPL allows the use of thinner membranes since it minimizes possible deformations in the membrane. Cells containing the MPLs outperformed those containing state-of-the-art commercially available PTL materials by up to 100 mV at 7 A cm-2 in combination with low-loaded catalyst-coated membranes of 0.4 mgIr cm-2. Hydrogen crossover is also reduced, especially at low current densities, leading to a larger turndown ratio which can enable more cost-effective operating strategies. Finally, these rationally designed MPLs also lead to high catalyst utilization by overcoming the naturally occurring high in-plane resistance of low-loaded catalyst layers.

hydrogen crossover↗

Extended Barton–Bandis model for rock joints under cyclic loading: Formulation and implicit algorithm

In this paper, the Barton–Bandis model for rock joints is extended to cyclic loading conditions, without any new material parameter. Also developed herein is an implicit solution algorithm for the extended Barton–Bandis model, which can also be used for the original Barton–Bandis model for which an implicit algorithm has been unavailable. To this end, we first cast the Barton–Bandis model into an incremental elasto-plastic framework, deriving an expression for the elastic shear stiffness being consistent with the original model formulation. We then extend the model formulation to cyclic loading conditions, incorporating the dependence of shear stress and dilation on the joint position and the shearing direction. The extension is achieved by introducing a few state-dependent variables which can be calculated with the existing material parameters. For robust and accurate utilization of the model, we also develop an implicit algorithm based on return mapping, which is unconditionally stable and guarantees the satisfaction of the strength criterion. We verify that the proposed model formulation and algorithm produce virtually the same results as the original Barton–Bandis model under monotonic shearing conditions. Here, we then validate the extended Barton–Bandis model against experimental data on natural rock joints under cycling loading conditions. The present work thus enables the Barton–Bandis model, which has been exceptionally popular in research and practice, to be applicable to a wider range of problems in rock mechanics and rock engineering.

58 GEOSCIENCES↗

Effect of sodium loading on Pt/ZrO 2 during ethanol steam reforming

Ethanol steam reforming (ESR) was investigated on unpromoted and several sodium promoted Pt/ZrO 2 catalysts. From DRIFTS experiments, the following steps during ESR were inferred: dissociation of ethanol to produce ethoxy species; oxidative dehydrogenation of ethoxy species to acetate; and acetate decomposition. Acetate decomposition depends on the catalyst formulation. Decarboxylation is the most favored route at high sodium loading (2.5 and 5 wt.%); acetate decomposes in the forward direction to CH 4 and a carbonate, which further decomposes to CO 2 . In contrast, decarbonylation is prevalent for the unpromoted catalyst or catalysts having low sodium loading. Furthermore, acetate likely decomposes to CH 3 OH and CO. Adsorbed methanol may undergo further steam reforming by oxidative dehydrogenation to formate species, which decarbonylates via reverse decomposition to CO and H 2 O. Temperature programmed desorption/reaction and activity data confirmed that alkali promotion, especially at 1.8 %Na and higher loading, facilitates the forward acetate decomposition step, favoring decarboxylation over decarbonylation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic fracture of glass fiber-reinforced ductile polymer matrix composites and loading rate effect

Here, the dynamic fracture of S-2 glass fiber-reinforced polymer matrix composites (FRPMCs) was investigated in this study. The matrix ductility was improved by a recently developed network topology modification technique via mixing partially reacted substructures (mPRS). The composite material was manufactured and characterized by micro-CT scanning and scanning electron microscopy (SEM). Dynamic single-edge notched bending (d-SENB) experiments were performed on the composites by using a modified split-Hopkinson pressure bar. Each specimen’s fracture process was visualized by ultrafast X-ray imaging. Such in-situ radiography enabled identifying the damage initiation below 50-micron scale and inspecting its propagation through the internal structures of opaque composites, thereby accurately quantifying the composites’ mechanical properties. Furthermore, the identical d-SENB experiments were designed and the digital image correlation (DIC) was employed to monitor the stress wave propagation on the composite specimens. The force and deflection measurements were modified and correlated to the physical damage processes. Besides, quasi-static SENB experiments were conducted to identify the loading rate effects on the composites’ fracture behaviors. The force and deflection history, bending stiffness, energy dissipation, and fracture toughness at different loading rates were quantified and compared. Finally, post-fracture analysis by micro-CT scanning and SEM provided physical observations on the variation of the fracture morphology by different loading rates.

42 ENGINEERING↗

Scaling of energy delivered through an electrostatic discharge to a small series load

We study the energy delivered through a small-resistance series “victim” load during electrostatic discharge events in air. For gap lengths over 1 mm, the fraction of the stored energy delivered is mostly gap-length independent, with a slight decrease at larger gaps due to electrode geometry. The energy to the victim scales linearly with circuit capacitance and victim load resistance but is not strongly dependent on circuit inductance. This scaling leads to a simple approach to predicting the maximum energy that will be delivered to a series resistance for the case where the victim load resistance is lower than the spark resistance.

42 ENGINEERING↗

COVID-19 pandemic ramifications on residential Smart homes energy use load profiles

The COVID-19 pandemic has significantly affected people’s behavioral patterns and schedules because of stay-at-home orders and a reduction of social interactions. Therefore, the shape of electrical loads associated with residential buildings has also changed. In this paper, we quantify the changes and perform a detailed analysis on how the load shapes have changed, and we make potential recommendations for utilities to handle peak load and demand response. Our analysis incorporates data from before and after the onset of the COVID-19 pandemic, from an Alabama Power Smart Neighborhood with energy-efficient/smart devices, using around 40 advanced metering infrastructure data points. This paper highlights the energy usage pattern changes between weekdays and weekends pre– and post–COVID-19 pandemic times. The weekend usage patterns look similar pre– and post–COVID-19 pandemic, but weekday patterns show significant changes. We also compare energy use of the Smart Neighborhood with a traditional neighborhood to better understand how energy-efficient/smart devices can provide energy savings, especially because of increased work-from-home situations. HVAC and water heating remain the largest consumers of electricity in residential homes, and our findings indicate an even further increase in energy use by these systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Nodal capacity expansion planning with flexible large-scale load siting

We propose explicitly incorporating large-scale load siting into a stochastic nodal power system capacity expansion planning model that concurrently co-optimizes generation, transmission, and storage expansion. The potential operational flexibility of some of these large loads is also taken into account by considering them as consisting of a set of tranches with different reliability requirements, which are modeled as a constraint on expected served energy across operational scenarios. We implement our model as a two-stage stochastic mixed-integer optimization problem with cross-scenario expectation constraints. To overcome the challenge of scalability, we build upon existing work to implement this model on a high performance computing platform and exploit scenario parallelization using an augmented Progressive Hedging Algorithm. The algorithm is implemented using the bounding features of mpisppy, which have shown to provide satisfactory provable optimality gaps despite the absence of theoretical guarantees of convergence. We test our approach and assess the value of this proactive planning framework on total system cost and reliability metrics using realistic testcases geographically assigned to San Diego and South Carolina, with datacenter and direct air capture facilities as large loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dirty dishes or dirty laundry? Comparing two methods for quantifying American consumers' preferences for load management in a smart home

One challenge of transitioning to renewable energy is that household electricity use and renewable generation are often misaligned. Smart home energy management systems hold promise for shifting usage to match generation, but these systems need to be designed with the occupants’ preferences in mind. The purpose of the present research is to compare two approaches for collecting and modeling consumers’ load management preferences, both of which are amenable to use in a home energy management system. Specifically, we examine the performance of Simple Multi-Attribute Rating Technique Exploiting Ranks (SMARTER) and Analytic Hierarchy Process (AHP) in quantifying consumers’ preferences regarding air temperature (air conditioning and heating), water heating, dishwashing, clothes washing and drying, monetary costs, environmental impacts, and comfort/convenience. Two studies are presented: Study 1 examines the SMARTER approach, and Study 2 focuses on the AHP approach. In both studies, online surveys (N SMARTER = 956 and N AHP = 1023) were conducted to elicit preferences from participants across the United States. The preferences modeled by both approaches were validated based on (a) their ability to predict participants’ choices in a Discrete Choice Experiment and (b) their convergence with previous research on load-shifting behavior. The validation procedure suggests that the SMARTER approach is superior in modeling consumers’ preferences for load management. Overall, this research lays the groundwork for designing a smart home interface capable of collecting occupants’ preferences and using those preferences to deliver improved occupant comfort, lower operating costs, reduced environmental impact, and more significant demand response than exists today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon sequestration and nitrogen and phosphorus accumulation in a freshwater, estuarine marsh: Effects of microtopography and nutrient loads

Wetlands are widely recognized as nutrient sinks for their ability to remove nutrients in runoff and retain them in soils. This is a valuable service, especially in agricultural watersheds, making nutrient removal one of the main goals in many wetland creation and restoration projects. However, incorporating nutrient management considerations requires site-level assessments, the scale at which wetland creation and restoration occur. Here we studied how carbon (C) sequestration, and nitrogen (N) and phosphorus (P) accumulation vary at different microtopographic levels and locations within a freshwater, estuarine marsh on the coast of Lake Erie. We further explored links between C sequestration, and N and P accumulation in recent years, and orthophosphate ($PO_{4}^{3-}$), ammonium ($NH_{4}^{+}$), and nitrate ($NO_{3}^{-}$) concentrations and loads. The rates of C sequestration and N accumulation were relatively lower at spots of intermediate depth and locations closer to the wetland’s main channel. P accumulation was highest at deep spots but did not differ among locations based on distance from the channel. Empirical models showed that nitrate load is the most important variable explaining the variability in C, N, and P sequestration/accumulation (r2 = 0.57, 0.61, and 0.32, respectively) and that the relationship between inorganic nutrient loads and accumulation was negative. Our findings suggest that including microtopographic relief features in wetland creation and design, especially deeper spots, is critical to enhancing wetland ecosystems’ C, N, and P sinking capacity. Also, that upstream nitrate management should be a priority to increase benefits from C sequestration and long-term N and P accumulation.

54 ENVIRONMENTAL SCIENCES↗