Development of a sealed lead-acid battery for use in space Final report
Development of sealed lead-acid battery with lead- calcium grid for space application
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Development of sealed lead-acid battery with lead- calcium grid for space application
Aqueous and nonqueous electrolytic actions, and energy density measurements for dry tape battery
Inorganic separator for high temperature silver-zinc battery
Filler and matrix composite materials for use in silver-zinc battery separators
Multisweep cyclic voltammetry for electrochemical characterization of systems for secondary battery application
Inorganic fillers and pressure effects on films for separators for heat sterilizable silver zinc battery
Primary zinc-silver oxide battery - separator material, construction, and prototype cell evaluation
Test of electrochemical cell and local action mechanisms of wet cell battery for space probe applications
Dry tape battery concept - cathode and anode research, energy densities, tape cell preparation, and supporting research
Silver-cadmium secondary battery energy storage system using vented cells for manned orbital spacecraft
Explore the source record for details and available documents.
Highly effective electromagnetic (EM) wave absorber materials with strong reflection loss (RL) and a wide absorption bandwidth (EBW) in gigahertz (GHz) frequencies are crucial for advanced wireless applications and portable electronics. Traditional microwave absorbers lack magnetic loss and struggle with impedance matching, while ferrites are stable, exhibit excellent magnetic and dielectric losses, and offer better impedance matching. However, achieving the desired EBW in ferrites remains a challenge, necessitating further composition design. In this study, impedance matching is successfully enhanced and EBW in Ni–Zn ferrite is broadened by successive doping with Mn and Co , without incorporation of any polymer filler. It is found that Ni 0.4 Co 0.1 Zn 0.5 Fe 1.9 Mn 0.1 O 4 material exhibits exceptional EM wave absorption, with a maximum RL of −48.7 dB. It also featured a significant EBW of 10.8 GHz, maintaining a 90% absorption rate (RL < −10 dB) for a thickness of 4.5 mm. These outstanding properties result from substantial magnetic losses and favorable impedance matching. These findings represent a significant step forward in the development of microwave absorber materials, addressing EM wave pollution concerns within GHz frequencies, including the frequency band used in popular 5G technology.
Computer methods for collection, reduction, correlation, and analysis of spacecraft nickel-cadmium battery test data
The NASA Aerospace Flight Battery Systems Program task status is reviewed. Major tasks incorporated in the program are battery systems, secondary batteries, and primary batteries.
Since January 1999, the chemical the International Space Station Thermal Control System (IATCS) and microbial state of (ISS) Internal Active fluid has been monitored by analysis of samples returned to Earth. Key chemical parameters have changed over time, including a drop in pH from the specified 9.5 +/- 0.5 ta = 58.4, an increase in the level of total inorganic carbon (TIC), total organic carbon (TOC) and dissolved nickel (Ni) in the fluid, and a decrease in the phosphate (PO,) level. In addition, silver (AS) ion levels in the fluid decreased rapidly as Ag deposited on internal metallic surfaces of the system. The lack of available Ag ions coupled with changes in the fluid chemistry has resulted in a favorable environment for microbial growth. Counts of heterotrophic bacteria have increased from less than 10 colony-forming units (CFUs)/l00 mL to l0(exp 6) to l0(exp 7) CFUs/100 mL. The increase of the microbial population is of concern because uncontrolled microbiological growth in the IATCS can contribute to deterioration in the performance of critical components within the system and potentially impact human health if opportunistic pathogens become established and escape into the cabin atmosphere. Micro-organisms can potentially degrade the coolant chemistry; attach to surfaces and form biofilms; lead to biofouling of filters, tubing, and pumps; decrease flow rates; reduce heat transfer; initiate and accelerate corrosion; and enhance mineral scale formation. The micro- biological data from the ISS IATCS fluid, and approaches to addressing the concerns, are summarized in this paper.
High capacity nonaqueous secondary battery development - lithium deposition and cycling, ionic solvation, cathode construction and discharge efficiency, and solvent purification
Mars Pathfinder Lander was powered by Ga-As solar cells and a silver-zinc Battery.
In recent years following several spacecraft battery anomalies, it was determined that managing the operational factors of NASA flight NiCd rechargeable battery was very important in order to maintain space flight battery nominal performance. The optimization of existing flight battery operational performance was viewed as something new for a Taguchi Methods application.