Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Neutrino Physics Opportunities with Pion and Kaon Decay-at-Rest Neutrino Source

Low-energy neutrino sources, such as those from stopped-pion, stopped-kaon or core-collapse supernova, interact with target nuclei in detectors through either coherent elastic or inelastic scattering processes. These interactions provide valuable insights into various Standard Model and Beyond the Standard Model phenomena, with significant implications for nuclear physics, particle physics, and astrophysics. The precision of coherent elastic scattering, where the nucleus remains in its ground state, depends on the accuracy of the underlying weak form factor of the nucleus. In contrast, inelastic scattering, where neutrinos excite the target nucleus to low-lying nuclear states, involves complex nuclear structures and dynamics and are quite poorly constrained. In this talk, I will present the physics opportunities offered by these neutrino sources, produced as secondary beams in an electron beam dump configuration at Jefferson Lab, and discuss their synergy with global neutrino experiments.

Pandey, Vishvas [Fermilab]↗

Suppressing CO formation in low-temperature methanol steam reforming via Ce-modified CuZnGa layered oxide catalysts

Cu-based layered double hydroxides (LDHs) are widely recognized as effective catalysts for low-temperature methanol steam reforming, yet achieving high hydrogen productivity together with near-complete suppression of CO formation remains challenging. Here, we report the synthesis and evaluation of a series of CuZnGa LDH-derived catalysts and Ce-modified analogues prepared via an aqueous miscible organic method, which enables high metal dispersion and precise structural control. The optimized CuZnGa catalyst exhibits a hydrogen production rate of 16.9 µmol H 2 ·g cat −1 ·s −1 at 180 °C with an H 2 /CO ratio exceeding 3500, outperforming many state-of-the-art low-temperature systems. Importantly, the incorporation of small amounts of Ce further suppresses CO formation while maintaining high hydrogen productivity. Combined spectroscopic characterization and density functional theory calculations reveal that Ce is incorporated into the LDH lattice by substituting Ga 3+ sites up to a critical threshold, beyond which highly dispersed CeO x species are formed. These species provide mobile lattice oxygen that participates in a Mars-van Krevelen-type pathway, selectively oxidizing CO and suppressing the reverse water-gas shift reaction. This study establishes a clear relationship between Ce speciation, oxygen mobility, and catalytic selectivity in LDH-derived systems. The resulting catalysts demonstrate the potential of interface-engineered Cu-based materials for efficient low-temperature hydrogen production with minimal CO contamination.

09 BIOMASS FUELS↗

Cosmic shear cosmology beyond two-point statistics: a combined peak count and correlation function analysis of DES-Y1

ABSTRACT We constrain cosmological parameters from a joint cosmic shear analysis of peak-counts and the two-point shear correlation functions, as measured from the Dark Energy Survey (DES-Y1). We find the structure growth parameter $S_8\equiv \sigma _8\sqrt{\Omega _{\rm m}/0.3} = 0.766^{+0.033}_{-0.038}$ which, at 4.8 per cent precision, provides one of the tightest constraints on S8 from the DES-Y1 weak lensing data. In our simulation-based method we determine the expected DES-Y1 peak-count signal for a range of cosmologies sampled in four w cold dark matter parameters (Ωm, σ8, h, w0). We also determine the joint covariance matrix with over 1000 realizations at our fiducial cosmology. With mock DES-Y1 data we calibrate the impact of photometric redshift and shear calibration uncertainty on the peak-count, marginalizing over these uncertainties in our cosmological analysis. Using dedicated training samples we show that our measurements are unaffected by mass resolution limits in the simulation, and that our constraints are robust against uncertainty in the effect of baryon feedback. Accurate modelling for the impact of intrinsic alignments on the tomographic peak-count remains a challenge, currently limiting our exploitation of cross-correlated peak counts between high and low redshift bins. We demonstrate that once calibrated, a fully tomographic joint peak-count and correlation functions analysis has the potential to reach a 3 per cent precision on S8 for DES-Y1. Our methodology can be adopted to model any statistic that is sensitive to the non-Gaussian information encoded in the shear field. In order to accelerate the development of these beyond-two-point cosmic shear studies, our simulations are made available to the community upon request.

Harnois-Déraps, Joachim↗

Demonstration of new MeV-scale capabilities in large neutrino LArTPCs using ambient radiogenic and cosmogenic activity in MicroBooNE

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing and interpreting MeV-scale energy depositions, or blips, present in their data. We demonstrate new calorimetric and particle discrimination capabilities at the MeV energy scale using reconstructed blips in data from the MicroBooNE LArTPC at Fermilab. We observe a concentration of low-energy (<3 MeV) blips around fiberglass mechanical support struts along the time projection chamber edges with energy spectrum features consistent with the Compton edge of 2.614 MeV 208 Tl decay 𝛾 rays. These features are used to verify proper calibration of electron energy scales in MicroBooNE’s data to few percent precision and to measure the specific activity of 208 Tl in the fiberglass composing these struts, (11.7 ± 0.2⁢(stat) ± 3.1⁢(syst)) Bq/kg. Cosmogenically produced blips above 3 MeV in reconstructed energy are used to showcase the ability of large LArTPCs to distinguish between low-energy proton and electron energy depositions. An enriched sample of low-energy protons selected using this new particle discrimination technique is found to be smaller in data than in dedicated corsika cosmic-ray simulations, suggesting either incorrect corsika modeling of incident cosmic fluxes or particle transport modeling issues in geant4.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Off-shell Partition Functions in 3d Gravity

We explore three-dimensional gravity with negative cosmological constant via canonical quantization. We focus on chiral gravity which is related to a single copy of PSL(2,R) Chern-Simons theory and is simpler to treat in canonical quantization. Its phase space for an initial value surface Σ is given by the appropriate moduli space of Riemann surfaces. We use geometric quantization to compute partition functions of chiral gravity on three-manifolds of the form Σ×S 1 , where Σ can have asymptotic boundaries. Most of these topologies do not admit a classical solution and are thus not amenable to a direct semiclassical path integral computation. We use an index theorem that expresses the partition function as an integral of characteristic classes over phase space. In the presence of n asymptotic boundaries, we use techniques from equivariant cohomology to localize the integral to a finite-dimensional integral over $\overline{M}$ g,n , which we evaluate in low genus cases. Higher genus partition functions quickly become complicated since they depend in an oscillatory way on Newton's constant. There is a precise sense in which one can isolate the non-oscillatory part which we call the fake partition function. We establish that there is a topological recursion that computes the fake partition functions for arbitrary Riemann surfaces Σ. As a result, there is a scaling limit in which the model reduces to JT gravity and our methods give a novel way to compute JT partition functions via equivariant localization.

Classical and Quantum Gravity↗

Role of surface diffusion in formation of unique reactivity for graphite oxidation: Time-resolved measurements in a pulsed diffusion reactor

Quantification of oxidation kinetics is essential to develop graphitic materials for diverse applications: from refractories found in gas-cooled nuclear reactors to catalysts needed for chemical manufacturing. In this work, using well-defined highly oriented pyrolytic graphite, low-pressure isotopic transient experiments combined with controlled annealing periods, we resolve the role of surface diffusion and quantify oxidation kinetics with nanomole-precision. We observe an unexpected increase in reactivity following annealing which is explained by the role of surface diffusion increasing the probability for trapping mobile oxygen at more reactive edge sites. Here, the locus of adsorption and spillover to the basal plane is distinct from the trapping location creating a more active oxygen species. Isotopic products reflect the population dynamics of oxygen added at the edge and surface diffusion that relocates basal plane oxygen to more reactive edge sites. Since this process proceeds in parallel with direct oxidation reactions, it is not likely to be observed using steady-state or conventional ‘bulk’ characterization techniques. Our unique time-resolved non-equilibrium measurement in a well-defined transport regime, enables observation of three distinct behaviors: short-term deactivation due to the balance of rates in oxygen supply/product formation, reactivity increases due to surface diffusion and longer-term reactivity increase with oxygen accumulation.

36 MATERIALS SCIENCE↗

Sources of Li isotope bias during SIMS analysis of standard glasses

The 7 Li/ 6 Li ratios in fourteen USGS, MPI-DING, and NIST glass reference materials (RMs) were analyzed by LG-SIMS to assess compositional matrix effects, evaluate RM δ 7 Li homogeneity, and calculate the useful yield of lithium in silicate glasses. The analyzed RMs cover a range of SiO 2 contents from 45.5 to 75.6% (komatiite to rhyolite), the largest compositional range yet evaluated for δ 7 Li matrix effects. We observe a matrix-induced bias (matrix effect) of up to 18‰ over the studied range that linearly correlates with SiO 2 content, demonstrating that SiO 2 content is a critical factor that must be considered when using silicate glasses to standardize for silicate samples of unknown δ 7 Li composition. All RMs were found to be sufficiently reproducible to aid in standardization of variable SiO 2 contents and appear isotopically homogeneous at the precision of our measurements. Lithium ionizes very efficiently in these RMs, with measurable yields >5% in all fused-rock RMs and >15% in low SiO 2 fused-rock RMs measured at high beam intensities. Finally, fused-rock RMs ionize lithium 2-3x more efficiently than synthetic glass RMs, which may be related to differences in major oxide chemistry and the reduced nature of the synthetic glasses relative to their fused counterparts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vaporizable endoskeletal droplets via tunable interfacial melting transitions

Liquid emulsion droplet evaporation is of importance for various sensing and imaging applications. The liquid-to-gas phase transformation is typically triggered thermally or acoustically by low–boiling point liquids, or by inclusion of solid structures that pin the vapor/liquid contact line to facilitate heterogeneous nucleation. However, these approaches lack precise tunability in vaporization behavior. Here, we describe a previously unused approach to control vaporization behavior through an endoskeleton that can melt and blend into the liquid core to either enhance or disrupt cohesive intermolecular forces. This effect is demonstrated using perfluoropentane (C 5 F 12 ) droplets encapsulating a fluorocarbon (FC) or hydrocarbon (HC) endoskeleton. FC skeletons inhibit vaporization, whereas HC skeletons trigger vaporization near the rotator melting transition. Our findings highlight the importance of skeletal interfacial mixing for initiating droplet vaporization. Tuning molecular interactions between the endoskeleton and droplet phase is generalizable for achieving emulsion or other secondary phase transitions, in emulsions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

National User Resource for Biological Accelerator Mass Spectrometry Annual Report

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science.

59 BASIC BIOLOGICAL SCIENCES↗

National User Resource for Biological Accelerator Mass Spectrometry

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National User Resource for Biological Accelerator Mass Spectrometry (Final Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions. Over the next five years, our goals are to: 1. Improve the efficiency of operation for AMS measurements through installation of new interfaces to our AMS systems, technical modifications to improve gas accepting ion source efficiency and upgrading our data analysis software for improved ease of use and data reporting. 2. Increase the accessibility and visibility of ultra-sensitive 14C measurements for the biomedical research community by training of new investigators and expanding our national user base. 3. Provide high throughput, ultra-sensitive 14C analysis for the NIGMS and NIH user community.

47 OTHER INSTRUMENTATION↗

GPS Measurements of Precipitable Water Vapor Can Improve Survey Calibration: A Demonstration from KPNO and the Mayall z -band Legacy Survey

Dual-band Global Positioning Satellite (GPS) measurements of precipitable water vapor (PWV) at the Kitt Peak National Observatory predict the overall per-image sensitivity of the Mayall z-band Legacy Survey (MzLS). The per-image variation in the brightness of individual stars is strongly correlated with the measured PWV and the color of the star. Synthetic stellar spectra through TAPAS transmission models successfully predict the observed PWV-induced photometric variation. We find that PWV absorption can be well approximated by a linear relationship with (airmass × PWV) 0.6 and present an update on the traditional treatment in the literature. The MzLS zero-point sensitivity in electrons s –1 varies with a normalized-mean absolute deviation of 61 mmag. PWV variation accounts 23 mmag of this zero-point variation. The MzLS per-image absolute sensitivity decreases by 40 mmag per effective mm of PWV. The overall gray offset portion of this variation is corrected by the calibration to a reference catalog. But the relative calibration error between blue (r – z < 0.5 mag) versus red (1.2 mag < r – z) stars increases by 0.3–2 mmag per effective mm of PWV. We argue that GPS systems provide more precise PWV measurements than using differential measurements of stars of different colors and recommend that observatories install dual-band GPS as a low-maintenance, low-cost, auxiliary calibration system. We extend our results of the need for well-calibrated PWV measurements by presenting the calculations of the PWV photometric impact on three science cases of interest: stellar photometry, supernova cosmology, and quasar identification and variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

Characterization of Low-energy Ionization Signals in Silicon Detectors for the Nab Experiment

The Nab (Neutron a b) experiment is designed to measure the beta-antineutrino angular correlation in free neutron 𝛽 decay with an ultimate precision goal of 0.1%, providing input for tests of Cabibbo-Kobayashi-Maskawa matrix unitarity. This measurement is performed via detection of electrons and protons in delayed coincidence using custom large-area segmented silicon detectors. We present the characterization of one such detector system to establish the proton energy and timing response, using a dedicated proton accelerator. The detected proton peak was studied for 25, 30, and 35 keV incident protons on a set of detector segments and multiple cooling cycles over a one-year period. Ionization losses were consistent with models of the detector dead layer with thicknesses less than 100 nm. The detected proton peak was stable within the uncertainty from energy calibration (0.25 keV). The rise times of detector pulses from 109Cd and 113Sn conversion electron sources were used to extract the impurity density profile and establish a precise model for the detector timing response. The observed impurity density profile varied from (2±2)×109/cm3 at the center to (26±2)×109/cm3 at the edge. This impurity density profile was then used to characterize systematic effects in proton time-of-flight measurements due to detector pulse-shape effects; the resultant proton timing systematic uncertainties were below 0.3 ns, which is sufficient for the Nab experiment.

Taylor, RJ [North Carolina State University]↗

Estimating time in quantum chaotic systems and black holes

We characterize new universal features of the dynamics of chaotic quantum many-body systems, by considering a hypothetical task of "time estimation". Most macroscopic observables in a chaotic system equilibrate to nearly constant late-time values. Intuitively, it should become increasingly difficult to estimate the precise value of time by making measurements on the state. We use a quantity called the Fisher information from quantum metrology to quantify the minimum uncertainty in estimating time. Due to unitarity, the uncertainty in the time estimate does not grow with time if we have access to optimal measurements on the full system. Restricting the measurements to act on a small subsystem or to have low computational complexity leads to results expected from equilibration, where the time uncertainty becomes large at late times. With optimal measurements on a subsystem larger than half of the system, we regain the ability to estimate the time very precisely, even at late times. Hawking's calculation for the reduced density matrix of the black hole radiation in semiclassical gravity contradicts our general predictions for unitary quantum chaotic systems. Hawking's state always has a large uncertainty for attempts to estimate the time using the radiation, whereas our general results imply that the uncertainty should become small after the Page time. This gives a new version of the black hole information loss paradox in terms of the time estimation task. By restricting to simple measurements on the radiation, the time uncertainty becomes large. This indicates from a new perspective that the observations of computationally bounded agents are consistent with the semiclassical effective description of gravity.

Black holes↗

Use of the Manuela 3D/Radiation Scanning Tool at Nuclear Facilities - 20437

Licensees, facility operators and decommissioning contractors have a need for comprehensive, accurate and precise radiological and topographical data to plan and execute safe and efficient Decontamination and Decommissioning (D and D) projects. Traditional approaches rely greatly upon labor and administratively intensive data collection methods that require considerable time and effort to glean the relevant data to plan and perform work in a radiological work area. Orano Decommissioning Services has developed and utilized at French nuclear facilities a lightweight portable scanning instrument called MANUELA (Mobile Apparatus for Nuclear Expertise Localization Assistance). Recently Orano conducted demonstrations at two United States nuclear facilities using MANUELA that may prove useful in areas of the fuel cycle including: - ALARA (As Low As Reasonably Achievable) planning during facility operations; - Scoping and site characterization during the D and D planning phase; - Remedial action support during active decommissioning work; - Radiation and modeling planning for plant modifications; - Support Final Status Survey and demonstration of 'end state' compliance for license termination. MANUELA is currently being evaluated for use during decommissioning of nuclear facilities and could aide in demonstrating compliance with end state criteria after decommissioning. Of particular interest are decommissioning projects planned for various sites across the United States. Most of these sites present unique challenges and opportunities to safely and efficiently decommission in a regulatory compliant manner. The two demonstration site's current conditions of relatively low radiation levels inside containment proved to be ideal platforms to deploy the MANUELA instrument for evaluation of the complex geometries typically found in a nuclear facility. The MANUELA instrument was able to precisely identify local hot spots of the reactor system's primary equipment and was able to simultaneously overlay the dose information onto the scanned 3D images. Using data like this, a licensee would be able to make informed technical and personnel decisions on methods to remediate, shield or properly dispose of the radioactive source term. MANUELA can be used throughout the decommissioning process to validate progress and continue to refine the work activities to optimize the efforts of the crew which reduces downtime waiting for survey results, whereas traditional survey methodology relies on a physical survey to be performed and the data transcribed onto survey maps that are only two dimensional. The traditional format tends to be inaccurate and difficult to interpret the precise location(s) of hot spots or generalized dose rates. The resultant scan also allows the user to know the exact extent of the survey versus transposing information onto a map with only a portion of the map area scanned. MANUELA also compiles all of the relevant survey data into a downloadable table format which includes the measurement identification number, time stamp, point space location on the XYZ plane, and the dose rate value. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gravitational Cardy limit and AdS black hole entropy

We explore the gravitational implementation of the field theory Cardy-like limit recently used in the successful microstate countings of AdS black hole entropy in various dimensions. On the field theory side, the Cardy-like limit focuses on a particular scaling of conserved electric charges and angular momenta and we first translate this scaling to the gravitational side by a limiting procedure on the black hole parameters. We note that the scaling naturally accompanies a near-horizon region for which these black hole solutions are greatly simplified. Applying the Kerr/CFT correspondence to the near-horizon region, we precisely reproduce the Bekenstein-Hawking entropy of asymptotically AdS 4,5,6,7 BPS black holes. Our results explicitly provide a microscopic and universal low energy description for AdS black holes across various dimensions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗