Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Magnetic resonance imaging and computational fluid dynamics (CFD) simulations of rabbit nasal airflows for the development of hybrid CFD/PBPK models

The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation. These airflows calculations, along with nasal airway geometry determinations, are critical parameters for hybrid CFD/physiologically based pharmacokinetic models that describe the nasal dosimetry of water-soluble or reactive gases and vapors in rabbits. CFD simulations were based upon three-dimensional computational meshes derived from magnetic resonance images of three adult female New Zealand White (NZW) rabbits. In the anterior portion of the nose, the maxillary turbinates of rabbits are considerably more complex than comparable regions in rats, mice, monkeys, or humans. This leads to a greater surface area to volume ratio in this region and thus the potential for increased extraction of water soluble or reactive gases and vapors in the anterior portion of the nose compared to many other species. Although there was considerable interanimal variability in the fine structures of the nasal turbinates and airflows in the anterior portions of the nose, there was remarkable consistency between rabbits in the percentage of total inspired airflows that reached the ethmoid turbinate region (~50%) that is presumably lined with olfactory epithelium. These latter results (airflows reaching the ethmoid turbinate region) were higher than previous published estimates for the male F344 rat (19%) and human (7%). These differences in regional airflows can have significant implications in interspecies extrapolations of nasal dosimetry.

59 BASIC BIOLOGICAL SCIENCES↗

High Occurrence of Aberrant Lymph Node Spread on Magnetic Resonance Lymphography in Prostate Cancer Patients With a Biochemical Recurrence After Radical Prostatectomy

Purpose: To investigate the pattern of lymph node spread in prostate cancer patients with a biochemical recurrence after radical prostatectomy, eligible for salvage radiotherapy; and to determine whether the clinical target volume (CTV) for elective pelvic irradiation in the primary setting can be applied in the salvage setting for patients with (a high risk of) lymph node metastases. Methods and Materials: The charts of 47 prostate cancer patients with PSA recurrence after prostatectomy who had positive lymph nodes on magnetic resonance lymphography (MRL) were reviewed. Positive lymph nodes were assigned to a lymph node region according to the guidelines of the Radiation Therapy Oncology Group (RTOG) for delineation of the CTV for pelvic irradiation (RTOG-CTV). We defined four lymph node regions for positive nodes outside this RTOG-CTV: the para-aortal, proximal common iliac, pararectal, and paravesical regions. They were referred to as aberrant lymph node regions. For each patient, clinical and pathologic features were recorded, and their association with aberrant lymph drainage was investigated. The distribution of positive lymph nodes was analyzed separately for patients with a prostate-specific antigen (PSA) <1.0 ng/mL. Results: MRL detected positive aberrant lymph nodes in 37 patients (79%). In 20 patients (43%) a positive lymph node was found in the pararectal region. Higher PSA at the time of MRL was associated with the presence of positive lymph nodes in the para-aortic region (2.49 vs. 0.82 ng/mL; p = 0.007) and in the proximal common iliac region (1.95 vs. 0.59 ng/mL; p = 0.009). There were 18 patients with a PSA <1.0 ng/mL. Ten of these patients (61%) had at least one aberrant positive lymph node. Conclusion: Seventy-nine percent of the PSA-recurrent patients had at least one aberrant positive lymph node. Application of the standard RTOG-CTV for pelvic irradiation in the salvage setting therefore seems to be inappropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging-Guided Intracavitary Brachytherapy for Cancer of the Cervix

Purpose: To determine the feasibility and benefits of optimized magnetic resonance imaging (MRI)-guided brachytherapy (BT) for cancer of the cervix. Methods and Materials: A total of 20 patients with International Federation of Gynecology and Obstetrics Stage IB-IV cervical cancer had an MRI-compatible intrauterine BT applicator inserted after external beam radiotherapy. MRI scans were acquired, and the gross tumor volume at diagnosis and at BT, the high-risk (HR) and intermediate-risk clinical target volume (CTV), and rectal, sigmoid, and bladder walls were delineated. Pulsed-dose-rate BT was planned and delivered in a conventional manner. Optimized MRI-based plans were developed and compared with the conventional plans. Results: The HR CTV and intermediate-risk CTV were adequately treated (the percentage of volume treated to {>=}100% of the intended dose was >95%) in 70% and 85% of the patients with the conventional plans, respectively, and in 75% and 95% of the patients with the optimized plans, respectively. The minimal dose to the contiguous 2 cm{sup 3} of the rectal, sigmoid, and bladder wall volume was 16 {+-} 6.2, 25 {+-} 8.7, and 31 {+-} 9.2 Gy, respectively. With MRI-guided BT optimization, it was possible to maintain coverage of the HR-CTV and reduce the dose to the normal tissues, especially in patients with small tumors at BT. In these patients, the HR percentage of volume treated to {>=}100% of the intended dose approached 100% in all cases, and the minimal dose to the contiguous 2-cm{sup 3} of the rectum, sigmoid, and bladder was 12-32% less than with conventional BT planning. Conclusion: MRI-based BT for cervical cancer has the potential to optimize primary tumor dosimetry and reduce the dose to critical normal tissues, particularly in patients with small tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison Between Perfusion Computed Tomography and Dynamic Contrast-Enhanced Magnetic Resonance Imaging in Rectal Cancer

Purpose: To compare pretreatment scans with perfusion computed tomography (pCT) vs. dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in rectal tumors. Methods and Materials: Nineteen patients diagnosed with rectal cancer were included in this prospective study. All patients underwent both pCT and DCE-MRI. Imaging was performed on a dedicated 40-slice CT-positron emission tomography system and a 3-T MRI system. Dynamic contrast enhancement was measured in tumor tissue and the external iliac artery. Tumor perfusion was quantified in terms of pharmacokinetic parameters: transfer constant K{sup trans}, fractional extravascular-extracellular space v{sub e}, and fractional plasma volume v{sub p}. Pharmacokinetic parameter values and their heterogeneity (by 80% quantile value) were compared between pCT and DCE-MRI. Results: Tumor K{sup trans} values correlated significantly for the voxel-by-voxel-derived median (Kendall's tau correlation, tau = 0.81, p < 0.001) and 80% quantile (tau = 0.54, p = 0.04), as well as for the averaged uptake (tau = 0.58, p = 0.03). However, no significant correlations were found for v{sub e} and v{sub p} derived from the voxel-by-voxel-derived median and 80% quantile and derived from the averaged uptake curves. Conclusions: This study demonstrated for the first time that pCT provides K{sup trans} values comparable to those of DCE-MRI. However, no correlation was found for the v{sub e} and v{sub p} parameters between CT and MRI. Computed tomography can serve as an alternative modality to MRI for the in vivo evaluation of tumor angiogenesis in terms of the transfer constant K{sup trans}.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Macroscopic Pathology Measurements With Magnetic Resonance Imaging and Assessment of Microscopic Pathology Extension for Colorectal Liver Metastases

Purpose: To compare pathology macroscopic tumor dimensions with magnetic resonance imaging (MRI) measurements and to establish the microscopic tumor extension of colorectal liver metastases. Methods and Materials: In a prospective pilot study we included patients with colorectal liver metastases planned for surgery and eligible for MRI. A liver MRI was performed within 48 hours before surgery. Directly after surgery, an MRI of the specimen was acquired to measure the degree of tumor shrinkage. The specimen was fixed in formalin for 48 hours, and another MRI was performed to assess the specimen/tumor shrinkage. All MRI sequences were imported into our radiotherapy treatment planning system, where the tumor and the specimen were delineated. For the macroscopic pathology analyses, photographs of the sliced specimens were used to delineate and reconstruct the tumor and the specimen volumes. Microscopic pathology analyses were conducted to assess the infiltration depth of tumor cell nests. Results: Between February 2009 and January 2010 we included 13 patients for analysis with 21 colorectal liver metastases. Specimen and tumor shrinkage after resection and fixation was negligible. The best tumor volume correlations between MRI and pathology were found for T1-weighted (w) echo gradient sequence (r{sub s} = 0.99, slope = 1.06), and the T2-w fast spin echo (FSE) single-shot sequence (r{sub s} = 0.99, slope = 1.08), followed by the T2-w FSE fat saturation sequence (r{sub s} = 0.99, slope = 1.23), and the T1-w gadolinium-enhanced sequence (r{sub s} = 0.98, slope = 1.24). We observed 39 tumor cell nests beyond the tumor border in 12 metastases. Microscopic extension was found between 0.2 and 10 mm from the main tumor, with 90% of the cases within 6 mm. Conclusions: MRI tumor dimensions showed a good agreement with the macroscopic pathology suggesting that MRI can be used for accurate tumor delineation. However, microscopic extensions found beyond the tumor border indicate that caution is needed in selecting appropriate tumor margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Screening of resonant magnetic perturbation fields by poloidally varying toroidal plasma rotation

The angular frequency of the subsonic equilibrium toroidal flow in a tokamak plasma is typically assumed constant at magnetic flux surfaces, i.e., the rotation frequency does not vary along the poloidal angle of the flux surface. Yet, there are several cases where this symmetry is broken. An interesting situation is a recently observed complex flow pattern induced by magnetic field line ergodization, in the presence of the tri-dimensional (3-D) resonant magnetic perturbation (RMP) [Schmitz et al., Nucl. Fusion 56, 066008 (2016)]. A new flow model including poloidally varying rotation frequencies has been implemented in the full resistive linear MHD code MARS-F [Liu et al., Phys. Plasmas 7, 3681 (2000)], allowing poloidal variation of the angular frequency of the equilibrium toroidal rotation in a generic toroidal geometry. The effect of this asymmetric flow, on top of a poloidally symmetric toroidal flow, on the plasma response to RMP fields is numerically investigated. It is found that a poloidally varying toroidal flow component enhances the favourable average curvature induced plasma screening of the applied 3-D field, for low toroidal flow velocities. At faster flow, when the resistive-inertial response becomes important, the asymmetric toroidal flow reduces the plasma screening. The most significant effect is found to come from the m=1 component of the poloidal asymmetry in the toroidal rotation frequency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Resonance Flow Velocity and Temperature Mapping of a Shape Memory Polymer Foam Device

Interventional medical devices based on thermally responsive shape memory polymer (SMP) are under development to treat stroke victims. The goals of these catheter-delivered devices include re-establishing blood flow in occluded arteries and preventing aneurysm rupture. Because these devices alter the hemodynamics and dissipate thermal energy during the therapeutic procedure, a first step in the device development process is to investigate fluid velocity and temperature changes following device deployment. A laser-heated SMP foam device was deployed in a simplified in vitro vascular model. Magnetic resonance imaging (MRI) techniques were used to assess the fluid dynamics and thermal changes associated with device deployment. Spatial maps of the steady-state fluid velocity and temperature change inside and outside the laser-heated SMP foam device were acquired. Though non-physiological conditions were used in this initial study, the utility of MRI in the development of a thermally-activated SMP foam device has been demonstrated.

42 ENGINEERING↗

Characterization of the AT180 epitope of phosphorylated Tau protein by a combined nuclear magnetic resonance and fluorescence spectroscopy approach

Highlights: {yields} pThr231 of the Tau protein is necessary for the binding of the AT180 antibody. {yields} pSer235 of the Tau protein does not interfere with the AT180 recognition of pThr231. {yields} Epitope mapping is efficiently achieved by combining NMR and FRET spectroscopy. -- Abstract: We present here the characterization of the epitope recognized by the AT180 monoclonal antibody currently used to define an Alzheimer's disease (AD)-related pathological form of the phosphorylated Tau protein. Some ambiguity remains as to the exact phospho-residue(s) recognized by this monoclonal: pThr231 or both pThr231 and pSer235. To answer this question, we have used a combination of nuclear magnetic resonance (NMR) and fluorescence spectroscopy to characterize in a qualitative and quantitative manner the phospho-residue(s) essential for the epitope recognition. Data from the first step of NMR experiments are used to map the residues bound by the antibodies, which were found to be limited to a few residues. A fluorophore is then chemically attached to a cystein residue introduced close-by the mapped epitope, at arginine 221, by mutagenesis of the recombinant protein. The second step of Foerster resonance energy transfer (FRET) between the AT180 antibody tryptophanes and the phospho-Tau protein fluorophore allows to calculate a dissociation constant Kd of 30 nM. We show that the sole pThr231 is necessary for the AT180 recognition of phospho-Tau and that phosphorylation of Ser235 does not interfere with the binding.

60 APPLIED LIFE SCIENCES↗

Nuclear Magnetic Resonance Project at the Medical University of South Carolina

Department of Energy funds were used to support the development of a Center for Marine Structural Biology at the Marine Resources Center at Ft. Johnson in Charleston, South Carolina. The Ft. Johnson site is home to five institutions in a unique state/federal/academic partnership whose member institutions include the National Ocean Service (NOS), the National Institute of Standards and Technology (NIST), the Medical University of South Carolina (MUSC), the SC Department of Natural Resources, and the College of Charleston. The Center for Marine Structural Biology sits adjacent to the newly completed Hollings Marine Laboratory and houses a 700 and 800 MHz nuclear magnetic resource instruments. The completed center is operational and meets it goal to provide state-of-the-art nuclear magnetic resonance capabilities to resolve the molecular structures of compounds that have direct relevance to human health, including marine-derived biotoxins that are tested against cancer cell lines through collaborative studies with researchers at the Hollings Cancer Center at MUSC. Funds from the DOE assisted, in part, with the purchase of NMR probes and ancillary equipment for the 800 MHz NMR instrument. In addition, developmental funds was used to support the visit of an Scientific Advisory Board and for the NMR Planning Team to visit currently operational high field NMR facilities to guide their choice of instrumentation and design of the building.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of the Magnetic Moment of the Probe of a Magnetic Resonance Force Microscope on the Spin-Wave Resonance Spectra

Abstract—The ferromagnetic resonance in an array of permalloy microstrips 3000 × 500 × 30 nm{sup 3} in size, which are ordered on a rectangular 3.5 × 6 μm{sup 2} lattice, is studied using magnetic resonance force microscopy with strong probe–sample interaction. This interaction induces intricate modifications of the observed spectra, which are manifested both in line splitting and in changes in shape. The dependences of the observed spectra on the sample–probe distance and the orientation of the magnetic moment of the probe are analyzed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Raman and nuclear magnetic resonance investigation of alkali metal vapor interaction with alkene-based anti-relaxation coating

The use of anti-relaxation coatings in alkali vapor cells yields substantial performance improvements compared to a bare glass surface by reducing the probability of spin relaxation in wall collisions by several orders of magnitude. Some of the most effective anti-relaxation coating materials are alpha-olefins, which (as in the case of more traditional paraffin coatings) must undergo a curing period after cell manufacturing in order to achieve the desired behavior. Until now, however, it has been unclear what physicochemical processes occur during cell curing, and how they may affect relevant cell properties. We present the results of nondestructive Raman-spectroscopy and magnetic-resonance investigations of the influence of alkali metal vapor (Cs or K) on an alpha-olefin, 1-nonadecene coating the inner surface of a glass cell. It was found that during the curing process, the alkali metal catalyzes migration of the carbon-carbon double bond, yielding a mixture of cis- and trans-2-nonadecene.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Phase Composition of Cobalt Nanoparticles Using {sup 59}Co Internal Field Nuclear Magnetic Resonance

It is well known that cobalt exhibits polymorphism, i.e., the co-existence of both the hcp and fcc phases. In particular, the method of synthesis and other thermodynamic conditions is known to play a crucial role in determining the particular phase of cobalt. In this work, we have compared the phase composition of the cobalt nanoparticles synthesized using two different solvents (water) and ethanol (Co@C). XRD measurements confirm the existence of fcc phase in commercial cobalt nanoparticles (Co@A), co-existence of fcc and hcp phases in Co@B, while the existence of the hcp phase in Co@C. We have studied these cobalt nanoparticles using {sup 59}Co internal field nuclear magnetic resonance (IFNMR) for verification of phase composition. Our studies reveal that the Co@A has fcc as a major phase with minor quantity hcp phase. Co@B exhibits approximately equal amount of fcc and hcp phase while Co@C exhibits hcp as a major phase with minor fcc phase. Our SEM micrograph studies confirm that the cobalt particles have spherical shape in the fcc phase. The cobalt particles exhibit both spherical and dendrite morphology confirming the co-existence of fcc and hcp phases, while the sample with pure hcp phase exhibits the dendrite morphology. Our studies also throw light on understanding the effect of solvent in the phase formation of the cobalt nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Role of Early Postradiation Magnetic Resonance Imaging Scans in Children With Diffuse Intrinsic Pontine Glioma

Purpose: To determine optimal timing of assessing postradiation radiographic response on magnetic resonance imaging (MRI) scans in pediatric patients with diffuse intrinsic pontine glioma (DIPG). Methods and Materials: Patients were treated on a prospective study at the National Cancer Institute (Protocol no. 06-C-0219) evaluating the effects of radiotherapy (RT). Standard RT was administered in standard fractionation over 6 weeks. Postradiation MRI scans were performed at 2 and 6-8 weeks. Results: Eleven patients with DIPG were evaluated. Median age was 6 years (range, 4-13 years). Patients were treated with external-beam RT to 55.8 Gy (n = 10) or 54 Gy (n = 1), with a gross tumor volume to planning target volume expansion of 1.8-2.0 cm. All patients received prescribed dose and underwent posttreatment MRI scans at 2 and 6-8 weeks. Pretreatment imaging revealed compression of fourth ventricle (n = 11); basilar artery encasement (n = 9); tumor extension outside the pons (n = 11); and tumor hemorrhage (n = 2). At the 2-week scan, basilar artery encasement improved in 7 of 9 patients, and extent of tumor was reduced in 5 of 11 patients. Fourth ventricle compression improved in 6 of 11 patients but worsened in 3 of 11 patients. Presumed necrosis was observed in 5 of 11 patients at 2 weeks and in 1 additional patient at 6-8 weeks. There was no significant difference in mean anteroposterior and transverse diameters of tumor between the 2- and 6-8-week time points. Six of 11 patients had increasing ventricular size, with no evidence of obstruction. Conclusions: There is no significant difference in tumor size of DIPG patients who have received standard RT when measured at 2 weeks vs. 6-8 weeks after RT. The majority of patients had the largest change in tumor size at the 2-week post-RT scan, with evolving changes documented on the 6-8-week scan. Six of 11 patients had progressive ventriculomegaly without obstruction, suggestive of communicating hydrocephalus. To the best of our knowledge, this is the first documentation of this phenomenon in this cohort of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Technique for Generating Volumetric Cine-Magnetic Resonance Imaging

Purpose: The purpose of this study was to develop a techique to generate on-board volumetric cine-magnetic resonance imaging (VC-MRI) using patient prior images, motion modeling, and on-board 2-dimensional cine MRI. Methods and Materials: One phase of a 4-dimensional MRI acquired during patient simulation is used as patient prior images. Three major respiratory deformation patterns of the patient are extracted from 4-dimensional MRI based on principal-component analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2-dimensional cine MRI. The method was evaluated using both digital extended-cardiac torso (XCAT) simulation of lung cancer patients and MRI data from 4 real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using volume-percent-difference (VPD), center-of-mass-shift (COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest (ROI) selection, patient breathing pattern change, and noise on the estimation accuracy were also evaluated. Results: Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between normalized profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was, on average, 8.43 ± 1.52% and the COMS was, on average, 0.93 ± 0.58 mm across all time steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR = 20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions: Preliminary studies demonstrated the feasibility of generating real-time VC-MRI for on-board localization of moving targets in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of hydrogen storage in sandstone reservoirs using 1 H nuclear magnetic resonance spectroscopy

Evaluation of the hydrogen storage capacity of porous rocks is crucial for underground hydrogen storage. Using 1 H nuclear magnetic resonance (NMR) spectroscopy, we successfully characterized the hydrogen responses and identified storage mechanisms in Berea sandstone under varying water saturation. Here, the results indicate that the injected hydrogen behaves as a free gas phase and is capable of occupying the empty pore volume regardless of the saturation state. No hysteresis was observed during injection and production cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of elongation and triangularity on plasma response to resonant magnetic perturbations

Abstract Systematic toroidal modeling of the plasma response to the n = 1–4 ( n is the toroidal mode number) resonant magnetic perturbation (RMP) field is carried out in order to understand the plasma-shaping effect on controlling the type-I edge-localized modes (ELMs) in tokamak experiments. Considered are large variations of the plasma elongation and triangularity at a fixed edge safety factor q a , for limiter plasmas with both single-null (SN) and double-null (DN) divertor-like boundary shapes. Numerical results assuming conformal 3D RMP coils show that (i) the optimum coil phasing between the upper and lower rows for ELM control becomes increasingly sensitive to the plasma elongation with higher- n toroidal spectra, (ii) the optimum coil phasing is however essentially independent of the plasma triangularity for all n = 1–4 RMP fields, (iii) with the same coil current and the optimum coil phasing, high elongation generally favors ELM control but it may be more challenging for plasmas with intermediate elongation and with lower- n ( n = 1–2) RMPs, and (iv) higher triangularity is generally always better for ELM control with all n = 1–4 fields for both DN and SN divertor-like plasma boundary shapes.

Physics↗

Direct Numerical Simulation of Pore-Scale Flow in a Bead Pack: Comparison with Magnetic Resonance Imaging Observations

A significant body of current research is aimed at developing methods for numerical simulation of flow and transport in porous media that explicitly resolve complex pore and solid geometries, and at utilizing such models to study the relationships between fundamental pore-scale processes and macroscopic manifestations at larger (i.e., Darcy) scales. A number of different numerical methods for pore-scale simulation have been developed, and have been extensively tested and validated for simplified geometries. However, validation of pore-scale simulations of fluid velocity for complex, three-dimensional (3D) pore geometries that are representative of natural porous media is challenging due to our limited ability to measure pore-scale velocity in such systems. Recent advances in magnetic resonance imaging (MRI) offer the opportunity to measure not only the pore geometry, but also local fluid velocities under steady-state flow conditions in 3D and with high spatial resolution. In this paper, we present a 3D velocity field measured at sub-pore resolution (tens of micrometers) over a centimeter-scale 3D domain using MRI methods. We have utilized the measured pore geometry to perform 3D simulations of Navier-Stokes flow over the same domain using direct numerical simulation techniques. We present a comparison of the numerical simulation results with the measured velocity field. It is shown that the numerical results match the observed velocity patterns well overall except for a variance and small systematic scaling which can be attributed to the known experimental error in the MRI measurements. The comparisons presented here provide strong validation of the pore-scale simulation methods and new insights for interpretation of uncertainty in MRI measurements of pore-scale velocity. This study also provides a potential benchmark for future comparison of other pore-scale simulation methods.

computational fluid dynamics↗

Structural Studies of Alloyed and Nanoparticle Transition Metal Dichalcogenides by Selenium-77 Solid-State Nuclear Magnetic Resonance Spectroscopy

Layered transition metal dichalcogenides (TMDCs) such as MoS 2 , MoSe 2 , and WSe 2 are under intense investigation because they are atomically thin semiconductors with photophysical properties that can be tuned by changing their composition or morphology. Mechanochemical processing has been proposed as a method to obtain alloyed TMDCs in the series Mo 1–x W x S y Se 2–y (x = 0–1; y = 0–2). However, elucidating the chemical transformations occurring at the atomic scale following mechanochemical processing can be challenging because the products are often amorphous or microcrystalline. To address this challenge, we probe TMDC mixing and alloying by using a combination of powder X-ray diffraction, Raman spectroscopy, diffuse reflectance spectroscopy, 77 Se solid-state nuclear magnetic resonance (SSNMR) spectroscopy, and planewave density functional theory (DFT) calculations. The nature of the milling material and reaction atmosphere are shown to be essential factors in limiting the formation of undesired oxide byproducts. We demonstrate acquisition of 77 Se SSNMR spectra using different combinations of Carr-Purcell Meiboom-Gill acquisition (CPMG) pulse sequences, magic angle spinning (MAS), and MAS dynamic nuclear polarization. Further, the combination of SSNMR with the other characterization methods clearly demonstrates that high energy impact ball milling induces molecular level alloying of Mo, W and chalcogen atoms in the family Mo 1–x W x S y Se 2–y . Gauge including projector augmented wave DFT calculations yield accurate 77 Se chemical shift (CS) tensor components. 77 Se SSNMR spectroscopy was also applied to study the structure of WSe 2 nanocrystals intercalated with ethylenediamine. The intercalated WSe 2 nanocrystals exhibit a more positive isotropic 77 Se CS as compared to bulk WSe 2 , however, the 77 Se CS anisotropy is the same, confirming the WSe 2 layers have a similar structure as in their bulk counterparts.

36 MATERIALS SCIENCE↗