Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS SPECTROMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Development of an Atmospheric Pressure Ionization Mass Spectrometer

A commercial atmospheric pressure ionization mass spectrometer (APIMS) was purchased from EXTREL Mass Spectrometry, Inc. (Pittsburgh, PA). Our research objectives were to adapt this instrument and develop techniques for real-time determinations of the concentrations of trace species in the atmosphere. The prototype instrument is capable of making high frequency measurements with no sample preconcentrations. Isotopically labeled standards are used as an internal standard to obtain high precision and to compensate for changes in instrument sensitivity and analyte losses in the sampling manifold as described by Bandy and coworkers. The prototype instrument is capable of being deployed on NASA C130, Electra, P3, and DC8 aircraft. After purchasing and taking delivery by June 1994, we assembled the mass spectrometer, data acquisition, and manifold flow control instrumentation in electronic racks and performed tests.

Source record↗

Gravitropism in higher plant shoots. VI. Changing sensitivity to auxin in gravistimulated soybean hypocotyls

Although the Cholodny-Went model of auxin redistribution has been used to explain the transduction phase of gravitropism for over 60 years, problems are apparent, especially with dicot stems. An alternative to an auxin gradient is a physiological gradient in which lower tissues of a horizontal stem become more sensitive than upper tissues to auxin already present. Changes in tissue sensitivity to auxin were tested by immersing marked Glycine max Merrill (soybean) hypocotyl sections in buffered auxin solutions (0, 10(-8) to 10(-2) molar indoleacetic acid) and observing bending and growth of upper and lower surfaces. The two surfaces of horizontal hypocotyl sections responded differently to the same applied auxin stimulus; hypocotyls bent up (lower half grew more) in buffer alone or in low auxin levels, but bent down (upper half grew more) in high auxin. Dose-response curves were evaluated with Michaelis-Menten kinetics, with auxin-receptor binding analogous to enzyme-substrate binding. Vmax for the lower half was usually greater than that for the upper half, which could indicate more binding sites in the lower half. Km of the upper half was always greater than that of the lower half (unmeasurably low), which could indicate that upper-half binding sites had a much lower affinity for auxin than lower-half sites. Dose-response curves were also obtained for sections scrubbed' (cuticle abraded) on top or bottom before immersion in auxin, and gravitropic memory' experiments of L. Brauner and A. Hagar (1958 Planta 51: 115-147) were duplicated. [1-14C]Indoleacetic acid penetration was equal into the two halves, and endogenous plus exogenously supplied (not radiolabeled) free auxin in the two halves (by gas chromatography-selected ion monitoring-mass spectrometry) was also equal. Thus, differential growth occurred without free auxin redistribution, contrary to Cholodny-Went but in agreement with a sensitivity model.

NASA Discipline Number 29-20↗

Plasma Ion Composition Measurements for Europa

Jupiter magnetospheric interactions and surface composition, both important to subsurface ocean detection for the Galilean icy moons Europa, Ganymede, and Callisto, can be measured using plasma ion mass spectrometry on either an orbiting spacecraft or one designed for multiple flybys of these moons. Detection of emergent oceanic materials at the Europa surface is more likely than at Ganymede and Callisto. A key challenge is to resolve potential intrinsic Europan materials from the space weathering patina of iogenic species implanted onto the sensible surface by magnetospheric interactions. Species resolved measurements of pickup ion currents are also critical to extraction of oceanic induced magnetic fields from magnetospheric interaction background dominated by these currents. In general the chemical astrobiological potential of Europa should be determined through the combination of surface, ionospheric, and pickup ion composition measurements. The requisite Ion Mass Spectrometer (IMS) for these measurements would need to work in the high radiation environment of Jupiter's magnetosphere between the orbits of Europa and Ganymede, and beyond. A 3D hybrid model of the moon magnetosphere interaction is also needed to construct a global model of the electric and magnetic fields, and the plasma environment, around Europa. Europa's ionosphere is probably usually dominated by hot pickup ions with 100-1000 eV temperatures, excursions to a "classical" cold ionosphere likely being infrequent. A field aligned ionospheric wind driven by the electron polarization electric field should arise and be measurable.

Plasma↗

Ion Neutral Mass Spectrometer Measurements from Titan

Introduction: The Ion Neutral Mass Spectrometer (INMS) aboard the Cassini orbiter has obtained the first in situ composition measurements of the neutral densities of molecular nitrogen, methane, argon, and a host of stable carbon-nitrile compounds in its first flyby of Titan. The bulk composition and thermal structure of the moon s upper atmosphere do not appear to be changed since the Voyager flyby in 1979. However, the more sensitive techniques provided by modern in-situ mass spectrometry also give evidence for large-spatial-scale large-amplitude atmospheric waves in the upper atmosphere and for a plethora of stable carbon-nitrile compounds above 1174 km. Furthermore, they allow the first direct measurements of isotopes of nitrogen, carbon, and argon, which provide interesting clues about the evolution of the atmosphere. The atmosphere was first accreted as ammonia and ammonia ices from the Saturn sub-nebula. Subsequent photochemistry likely converted the atmosphere into molecular nitrogen. The early atmosphere was 1.5 to 5 times more substantial and was lost via escape over the intervening 4.5 billion years due to the reduced gravity associated with the relatively small mass of Titan. Carbon in the form of methane has continued to outgas over time from the interior with much of it being deposited in the form of complex hydrocarbons on the surface and some of it also being lost to space.

Waite, J. H., Jr.↗

Isotopic, optical, and trace element properties of large single SiC grains from the Murchison meteorite

Ion probe mass spectrometry is used to analyze 41 large SiC grains from the Murchison CM2 chondrite, ranging up to 15 x 26 microns, for the isotopic compositions of C, N, Mg, and Si, and the concentrations of Al, Ti, V, Fe, Zr, and Ba. The majority were found to have large isotopic anomalies. Only two grains, characterized by extremely heavy carbon, give evidence for fossil Mg-26. On the basis of C and Si isotopic composition, 29 of the grains fall into three compact clusters, presumably from three discrete sources. The clustering of coarse-grained SiC stands in sharp contrast to the quasi-continuous distribution of finer-grained SiC and suggests that the top 0.1 percent of the mass distribution is a distinct population. The C and N isotopic compositions of the anomalous grains are not very diagnostic, being consistent with H-burning in the CNO cycle. The Si-isotopic compositions qualitatively show the signature of neutron capture in He-burning shells of highly evolved stars.

Virag, Alois↗

Oxidation of the N-terminal methionine of lens alpha-A crystallin

Antiserum against the N-terminal peptide of bovine alpha-A crystallin has been used to monitor purification of two different seropositive peptides (i.e. T1a and T1b) from a tryptic digest of bovine lens proteins. Both these peptides have similar amino acid compositions, but peptide T1b has a molecular weight 16 atomic mass units larger than T1a, suggesting posttranslational modification. Analysis of ionization fragments of the T1b peptide by mass spectrometry demonstrates that this difference in molecular weight is due to the in vivo oxidation of the N-terminal met residue of the alpha-A crystallin molecule.

NASA Discipline Cell Biology↗

The determination of the global average OH concentration using a deuteroethane tracer

It is proposed to measure the decreasing global concentration of an OH reactive isotopic tracer, G sub 2 D sub 6, after its introduction into the troposphere in a manner to facilitate uniform global mixing. Analyses at the level of 2 x 10 to the -19th power fraction, corresponding to one kg uniformly distributed globally, should be possible by a combination of cryogenic absorption techniques to separate ethane from air and high sensitivity isotopic analysis of ethane by mass spectrometry. Aliquots of C sub 2 D sub 6 totaling one kg would be introduced to numerous southern and northern latitudes over a 10 day period in order to achieve a uniform global concentration within 3 to 6 months by the normal atmospheric circulation. Then samples of air of 1000 l (STP) would be collected periodically at a tropical and temperate zone location in each hemisphere and spiked with a known amount of another isotopic species of ethane, C-13 sub 2 H sub 6, at the level of 10 to the -11th power mole fraction. After separation of the ethanes from air, the absolute concentration of C sub 2 D sub 6 would be analyzed using the Argonne 100-inch radius mass spectrometer.

Stevens, Charles M.↗

Hypervelocity impact survivability experiments for carbonaceous impactors

We performed a series of hypervelocity impact experiments using carbon-bearing impactors (diamond, graphite, fullerenes, phthalic acid crystals, and Murchison meteorite) into Al plate at velocities between 4.2 and 6.1 km/s. These tests were made to do the following: (1) determine the survivability of carbon forms and organize molecules in low hypervelocity impact; (2) characterize carbonaceous impactor residues; and (3) determine whether or not fullerenes could form from carbonaceous impactors, under our experimental conditions, or survive as impactors. An analytical protocol of field emission SEM imagery, SEM-EDX, laser Raman spectroscopy, single and 2-stage laser mass spectrometry, and laser induced fluorescence (LIF) found the following: (1) diamonds did not survive impact at 4.8 km/s, but were transformed into various forms of disordered graphite; (2) intact, well-ordered graphite impactors did survive impact at 5.9 km/sec, but were only found in the crater bottom centers; the degree of impact-induced disorder in the graphite increases outward (walls, rims, ejecta); (3) phthalic acid crystals were destroyed on impact (at 4.2 km/s, although a large proportion of phthalic acid molecules did survive impact); (4) fullerenes did not form as products of carbonaceous impactors (5.9 - 6.1 km/s, fullerene impactor molecules mostly survived impact at 5.9 km/s; and (5) two Murchison meteorite samples (launched at 4.8 and 5.9 km/s) show preservation of some higher mass polycyclic aromatic hydrocarbons (PAHs) compared with the non-impacted sample. Each impactor type shows unique impactor residue morphologies produced at a given impact velocity. An expanded methodology is presented to announce relatively new analytical techniques together with innovative modifications to other methods that can be used to characterize small impact residues in LDEF craters, in addition to other acquired extraterrestrial samples.

Bunch, T. E.↗

Nitrogen metabolism in Lignifying Pinus taeda cell cultures

The primary metabolic fate of phyenylalanine, following its deamination in plants, is conscription of its carbon skeleton for lignin, suberin, flavonoid, and related metabolite formation. Since this accounts for approximately 30-40% of all organic carbon, an effective means of recycling the liberated ammonium ion must be operative. In order to establish how this occurs, the uptake and metabolism of various 15N-labeled precursors (15N-Phe, 15NH4Cl, 15N-Gln, and 15N-Glu) in lignifying Pinus taeda cell cultures was investigated, using a combination of high performance liquid chromatography, 15N NMR, and gas chromatograph-mass spectrometry analyses. It was found that the ammonium ion released during active phenylpropanoid metabolism was not made available for general amino acid/protein synthesis. Rather it was rapidly recycled back to regenerate phenylalanine, thereby providing an effective means of maintaining active phenylpropanoid metabolism with no additional nitrogen requirement. These results strongly suggest that, in lignifying cells, ammonium ion reassimilation is tightly compartmentalized.

NASA Discipline Number 40-50↗

Vaporization thermodynamics of K2S and K2SO3

The vaporization reactions, vapor pressures, and thermodynamics of potassium sulfide and potassium sulfite were studied for purposes of providing fundamental data for the seed cycle in magnetohydrodynamic electric power generation. Rate of effusion studies, supported by tube furnace experiments, X-ray powder diffraction, mass spectrometry and appropriate chemical analyses and tests, revealed that potassium sulfite disproportionates at high temperatures to form potassium sulfide and potassium sulfate. Potassium sulfide was observed to vaporize incongruently, the initial vapors beng predominantly potassium atoms, with minor species being S2 and various K-S molecules. The ratio of K/S2 in the vapor is very large initially and decreases steadily with prolonged heating. Several materials were evaluated for purposes of containing K2S/K2SO3 at temperatures or = 800 C: Pt, Mo, W, quartz, machinable glass, BN, high density graphite, pyrolytic coated graphite, and alumina. Of these, only alumina was observed to be chemically inert to both K2S but reacted with K2SO3. The other materials were not suitable for either substance. Thermodynamic calculations based on measured vapor pressures and approximate free energy functions are described. Results from isothermal total mass loss experiments and from thermogravimetric experiments are also included.

Bennet, J. E.↗

Separation of isobaric Amino Acids and Small Molecule Metabolites Using Multipass Ion Mobility Analysis

Amino acids along with small molecule metabolites are important biomarkers for the study and detection of diseases that are initially analyzed in untargeted omics fashion. Amino acids and many metabolites are isomeric, and their specific form can have a significant impact on biological function. Chromatographic separation of isomers is challenging, and they cannot be resolved by mass spectrometry alone. Ion mobility is a technique that allows the separation of ions based on their size, shape, and charge. Here we present the results of the separation of isobaric amino acids and small molecule metabolites using a system that allows for multi-pass ion mobility separation which, in turn, enhances the ion mobility resolution of the separation. Amino acid standards and small molecule metabolites commercially available were infused directly into a SELECT SERIES™ Cyclic™ IMS system. Solutions of individual and mixture of the isobaric species were used and the mobility conditions were optimized for multiple passes for each corresponding set of isobaric species. Both ionization polarities and various solvent adducts were tested to provide the best signal intensity and separation. Amino acids such as leucine and isoleucine have previously been separated with ion mobility in a system with lower ion mobility resolution (SYNAPT™ G2 mass spectrometer) rendering about 90% of valley and mobility resolution of around 40 Ω/ΔΩ. With the enhanced ion mobility resolution using the cyclic IMS technique we have obtained almost complete separation of those amino acids rendering a valley of about 10% after 15 passes. For this case, the mobility resolution is around 250 Ω/ΔΩ. Another example is the separation of glucose-6-phosphate from glucose-1-phosphate, and fructose-6phosphate which were separated after 10 passes. For this case, the mobility resolution is around 205 Ω/ΔΩ.

Hernando J Olivos↗

Application of High-Spatial Resolution LA-MC-ICP-MS in Planetary Materials

High-precision stable and radiogenic isotopic measurements of planetary materials can help elucidate processes taking place during early Solar System formation, as well as during subsequent planetary differentiation. Laser Ablation Multi Collector Inductively Coupled Plasma Mass Spectrometry (LA-MC-ICP-MS) adds the valuable ability of preserving the spatial context of these isotopic measurements, by sampling small sample volumes (~10 – 60 um diameter) using a pulsed laser system. In the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center, these in-situ isotopic measurements are primarily made using the Applied SpectraTM iX-fs-Tandem LA-LIBS Instrument coupled to the Nu InstrumentsTM SP1700 MC-ICP-MS. The instrumental set-up also provides simultaneous Laser Induced Breakdown Spectroscopy (LIBS) measurements and the potential use of a low energy path with a collision/reaction cell for additional interference removal, though we focus here on the typical high-energy LA-MC-ICP-MS operation. We will provide examples of stable (e.g., Mg) and radiogenic (e.g., Lu-Hf) isotopic systems measured in planetary materials and their terrestrial analogs. The measurement of mass dependent Mg isotopic variations is an important tool for reconstructing processes such as evaporation and condensation of solids in the solar nebula. For early Solar System samples, Mg isotope measurements are also important for the short-lived (t1/2 = 0.7 Ma) Al-Mg chronometer. During laser ablation analyses, the measurement of the Al-Mg isotopic system is made in medium mass resolution (RP ~9500 at ~20% transmission) to limit interferences from 48Ti2+ and 48Ca2+ on 24Mg+, in addition to 52Cr2+ and 12C14N+ on 26Mg+. Measured in the mineral zircon, the 176Lu-176Hf decay system is often used for understanding the growth of continents on Earth, and is also a vital aid in deciphering early large-scale planetary differentiation processes, such as the crystallization of the lunar magma ocean, which is thought to be responsible for much of the Moon’s crust. Lu-Hf measurements are made in low resolution mode (RP <2000), with 10 ion masses (from 171Yb to 180Hf) measured simultaneously to facilitate corrections for isobaric interferences from 176Yb and 176Lu on 176Hf.

Jacob B Setera↗

Calcium kinetics with microgram stable isotope doses and saliva sampling

Studies of calcium kinetics require administration of tracer doses of calcium and subsequent repeated sampling of biological fluids. This study was designed to develop techniques that would allow estimation of calcium kinetics by using small (micrograms) doses of isotopes instead of the more common large (mg) doses to minimize tracer perturbation of the system and reduce cost, and to explore the use of saliva sampling as an alternative to blood sampling. Subjects received an oral dose (133 micrograms) of 43Ca and an i.v. dose (7.7 micrograms) of 46Ca. Isotopic enrichment in blood, urine, saliva and feces was well above thermal ionization mass spectrometry measurement precision up to 170 h after dosing. Fractional calcium absorptions determined from isotopic ratios in blood, urine and saliva were similar. Compartmental modeling revealed that kinetic parameters determined from serum or saliva data were similar, decreasing the necessity for blood samples. It is concluded from these results that calcium kinetics can be assessed with micrograms doses of stable isotopes, thereby reducing tracer costs and with saliva samples, thereby reducing the amount of blood needed.

Clinical Trial↗

Calibration and Sequence Development Status for the Sample Analysis at Mars Investigation on the Mars Science Laboratory

The measurement goals of the Sample Analysis at Mars (SAM) instrument suite on the "Curiosity" Rover of the Mars Science Laboratory (MSL) include chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples [1,2]. SAM directly supports the ambitious goals of the MSL mission to provide a quantitative assessment of habitability and preservation in Gale crater by means of a range of chemical and geological measurements [3]. The SAM FM combined calibration and environmental testing took place primarily in 2010 with a limited set of tests implemented after integration into the rover in January 2011. The scope of SAM FM testing was limited both to preserve SAM consumables such as life time of its electromechanical elements and to minimize the level of terrestrial contamination in the SAM instrument. A more comprehensive calibration of a SAM-like suite of instruments will be implemented in 2012 with calibration runs planned for the SAM testbed. The SAM Testbed is nearly identical to the SAM FM and operates in a ambient pressure chamber. The SAM Instrument Suite: SAM's instruments are a Quadrupole Mass Spectrometer (QMS), a 6-column Gas Chromatograph (GC), and a 2-channel Tunable Laser Spectrometer (TLS). Gas Chromatography Mass Spectrometry is designed for identification of even trace organic compounds. The TLS [5] secures the C, H, and O isotopic composition in carbon dioxide, water, and methane. Sieved materials are delivered from the MSL sample acquisition and processing system to one of68 cups of the Sample Manipulation System (SMS). 59 of these cups are fabricated from inert quartz. After sample delivery, a cup is inserted into one of 2 ovens for evolved gas analysis (EGA ambient to >9500C) by the QMS and TLS. A portion of the gas released can be trapped and subsequently analyzed by GCMS. Nine sealed cups contain liquid solvents and chemical derivatization or thermochemolysis agents to extract and transform polar molecules such as amino acids, nucleobases, and carboxylic acids into compounds that are sufficiently volatile to transmit through the GC columns. The remaining 6 cups contain calibrants. SAM FM Calibration Overview: The SAM FM calibration in the Mars chamber employed a variety of pure gases, gas mixtures, and solid materials. Isotope calibration runs for the TLS utilized 13C enriched C02 standards and 0 enriched CH4. A variety of fluorocarbon compounds that spanned the entire mass range of the QMS as well as C3-C6 hydrocarbons were utilized for calibration of the GCMS. Solid samples consisting of a mixture of calcite, melanterite, and inert silica glass either doped or not with fluorocarbons were introduced into the SAM FM cups through the SAM inlet funnel/tube system.

Mahaffy, Paul R.↗

Origin of amphiphilic molecules and their role in primary structure formation

Attempts to solve two fundamental questions are described: the first concerns which mechanisms were responsible for the self-assembly of membrane structures on the prebiotic Earth, and the second concerns the routes by which considerable amounts of membrane amphiphiles formed from simpler hydrocarbons. The physicochemical properties of several amphiphilic compounds extracted from the Murchison carbonaceous chondrite were studied, using infra-red and fluorescent spectroscopy, measurements of surface activity, chromato-mass spectrometry, and polarization and electron microscopy. The results supported previous observations that amphiphilic and aromatic hydrocarbons were present in significant quantities, and the first demonstration of surface activity among a number of acidic derivatives of hydrocarbons is reported. In addition, one fraction of the surface-active compounds can form bilayer structures, showing that membranes could have self-assembled on the prebiotic Earth. Photochemical oxidation of hydrocarbons is shown to be a likely source of the amphiphilic molecules required for the self-assembly of primary membrane structures.

NASA Discipline Number 52-20↗

UV irradiation of polycyclic aromatic hydrocarbons in ices: production of alcohols, quinones, and ethers

Polycyclic aromatic hydrocarbons (PAHs) in water ice were exposed to ultraviolet (UV) radiation under astrophysical conditions, and the products were analyzed by infrared spectroscopy and mass spectrometry. Peripheral carbon atoms were oxidized, producing aromatic alcohols, ketones, and ethers, and reduced, producing partially hydrogenated aromatic hydrocarbons, molecules that account for the interstellar 3.4-micrometer emission feature. These classes of compounds are all present in carbonaceous meteorites. Hydrogen and deuterium atoms exchange readily between the PAHs and the ice, which may explain the deuterium enrichments found in certain meteoritic molecules. This work has important implications for extraterrestrial organics in biogenesis.

NASA Center ARC↗

Low-Energy Sputtering Studies of Boron Nitride with Xenon Ions

Sputtering of boron nitride with xenon ions was investigated using secondary ion (SIMS) and secondary neutral (SNMS) mass spectrometry. The ions generated from the ion gun were incident on the target at an angle of 50' with respect to the surface'normal. The energy of ions ranged from 100 eV to 3 keV. A flood electron gun was used to neutralize the positive charge build-up on the target surface. The intensities of sputtered neutral and charged particles, including single atoms, molecules, and clusters, were measured as a function of ion energy. Positive SIMS spectra were dominated by the two boron isotopes whereas BN- and B- were the two major constituents of the negative SIMS spectra. Nitrogen could be detected only in the SNMS spectra. The intensity-energy curves of the sputtered particles were similar in shape. The knees in P-SIMS and SNMS intensity-energy curves appear at around I keV which is significantly higher that 100 to 200 eV energy range at which knees appear in the sputtering of medium and heavy elements by ions of argon and xenon. This difference in the position of the sputter yield knee between boron nitride and heavier targets is due to the reduced ion energy differences. The isotopic composition of secondary ions of boron were measured by bombarding boron nitride with xenon ions at energies ranging from 100 eV to 1.5 keV using a quadrupole mass spectrometer. An ion gun was used to generate the ion beam. A flood electron gun was used to neutralize the positive charge buildup on the target surface. The secondary ion flux was found to be enriched in heavy isotopes at lower incident ion energies. The heavy isotope enrichment was observed to decrease with increasing primary ion energy. Beyond 350 eV, light isotopes were sputtered preferentially with the enrichment increasing to an asymptotic value of 1.27 at 1.5 keV. The trend is similar to that of the isotopic enrichment observed earlier when copper was sputtered with xenon ions in the same energy range.

Ray, P. K.↗

Novel long-chain anteiso-alkanes and anteiso-alkanoic acids in Antarctic rocks colonized by living and fossil cryptoendolithic microorganisms

Saponified extracts of rock samples colonized by cryptoendolithic microbial communities from the McMurdo Dry Valleys of Southern Victoria Land, Antarctica, were separated into hydrocarbon and fatty acid fractions by silica gel column chromatography. Hydrocarbons and methyl esters of fatty acids were analyzed by capillary gas chromatography-mass spectrometry. Unusually, a suite of long-chain anteiso-alkanes (a-C20 to a-C30) and anteiso-alkanoic acids (a-C20 to a-C30) were detected in many samples, together with straight-chain, branched and/or cyclic and acyclic isoprenoid compounds. These novel compounds are probably derived from unidentified heterotrophic bacteria or symbiotic processes in a unique microbial community in the Antarctic cold desert and suggest the occurrence of a special biosynthetic pathway. Long-chain anteiso-alkanes are probably formed through microbial decarboxylation of corresponding anteiso-alkanoic acids. They may serve as new biomarkers in environmental and geochemical studies.

NASA Program Exobiology↗