Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEASURING METHODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Optimal Transport as a Tool for Scientific Discovery in Radiation Biology

This report summarizes findings from research conducted for the “Exploration of the Poten tial for Artificial Intelligence and Machine Learning to Advance Low-Dose Radiation Biology Re search” (RadBio-AI) program, supported by the U.S. Department of Energy, Office of Science, Office of Biological and Environmental Research, under Awards KP1601011/FWP CC121 and KP1601017/FWP CC121. The research reported here was undertaken in an effort to assess the potential of optimal measure transport methods as components within the larger scope of a com putational framework envisioned to support research in the radiation biology domain. Within this effort, our interest centered on enabling a unified generic framework where probabilistic modeling, inference, and statistical learning can be carried out for a wide range of data distributions. As described next in Section 1 (and in more detail in our original publication), optimal measure transport offers the possibility of such unified approach.

97 MATHEMATICS AND COMPUTING↗

Pulse shape measurements for neutron/gamma discrimination using the TOFPET2 ASIC

Many highly pixelated organic scintillator detection systems would benefit from independent readout of each scintillator pixel. Recent advances in Silicon Photomultiplier (SiPM) technology makes this goal feasible, however the data acquisition from potentially hundreds or thousands of channels requires a low-cost and compact solution. For pixelated neutron detection with organic scintillators, the capability to distinguish between neutron and gamma interactions using Pulse Shape Discrimination (PSD) is required along with pulse charge and time of arrival. The TOFPET2 ASIC from PETsys Electronics is a 64-channel readout chip providing pulse time and charge integration measurements from SiPMs, and is specifically designed for time-of-flight positron-emission tomography. Using an 8 × 8 array of 6 mm × 6 mm J-series SiPMs from SensL/OnSemi (ArrayJ-60035-64P-PCB), we have studied the energy and PSD performance of the TOFPET2 ASIC using a 4 × 4 array of 6 mm × 6 mm × 30 mm trans -Stilbene crystals from Inrad Optics and a custom SiPM routing board from PETsys Electronics. In conclusion, using a time-over-threshold method, we measure a maximum PSD figure-of-merit of approximately 1.2 at 478 keV (the Compton edge of 662 keV) for a J-series SiPM operating at an over-voltage of 3V.

47 OTHER INSTRUMENTATION↗

DARHT Axis 1 Bremsstrahlung Dose Measurements

he Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography ca pabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces, nominally, a 20-MeV, 1.5-kA, 80-ns-Full Width at Half Max (FWHM) electron beam. The elec tron beam is focused on to a tantalum target to produce a Bremsstrahlung x-ray dose for flash radiography of dynamic systems. This paper will describe and compare a variety of techniques for determining the x-ray dose for two different beam currents produced by a 55mm and 70mm diameter cathode. The data was taken in November of 2022 on DARHT Axis 1. The experimen tal measurement techniques include a platinum calorimeter, a diamond radiation detector (DRD), and a Compton diode (CD). Gafchromic EBT3 self-developing dosimetry film was also used, but no useful results were obtained. Beam charge and energy were recorded and dose was calculated with this information using xtr with Dosecalcx, and simple dose charge-energy scaling. In this pa per, we will discuss the target geometry and experimental layout, the methods of measuring dose, dose diagnostics and measurement of beam charge and energy, and the comparisons of data and calculations.

43 PARTICLE ACCELERATORS↗

Precision measurement of lifetime and branching ratios of the 4⁢𝑓 13⁡ 5⁢𝑑⁢6⁢𝑠 1 ⁢[5/2] 5/2 state in Yb + ions

We report spectroscopic and time-resolved experimental observations to characterize the [Xe]⁢4⁢𝑓 13 ⁡( 2 𝐹$^𝑜_{5/2}$)⁢5⁢𝑑⁢6⁢𝑠⁡( 1 𝐷)⁢ 1 ⁢[5/2]$^𝑜_{5/2}$ state in 172 Yb + ions. We access this state from the metastable 4⁢𝑓 14 ⁡5⁢𝑑⁡( 2 𝐷 3/2,5/2 ) manifold and observe an unexpectedly long lifetime of 𝜏 = 37.9⁢(9) ⁢µ⁢s that allows visible Rabi oscillations and resolved-sideband spectroscopy. Using a combination of coherent population dynamics, high-fidelity detection and heralded state preparation, and optical pumping methods, we measure the branching ratios to the 2 𝐷 3/2 , 2 𝐷 5/2 , and 2 𝑆 1/2 states to be 0.359⁢(2), 0.639(2), and 0.0023⁢(16), respectively. The branching ratio to the 4⁢𝑓 13⁡ 6⁢𝑠 2 ⁡( 2 𝐹 7/2 ) is compatible with zero within our experimental resolution. We also report measurements of Landé 𝑔-factor of the 1 ⁢[5/2]$^𝑜_{5/2}$ state. Further, the branching ratio of the 2 𝐷 5/2 to 2 𝑆 1/2 decay in 172 Yb + was measured to be 0.188(3), improving its relative uncertainty by an order of magnitude. Our measurements provide experimental benchmarks for better understanding the atomic structure of Yb + ions, which still lacks accurate numerical descriptions, and the use of high-lying excited states for partial detection and qubit manipulation in the omg architecture.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ultrabroadband two-dimensional electronic spectroscopy in the pump–probe geometry using conventional optics

We report ultrabroadband two-dimensional electronic spectroscopy (2D ES) measurements obtained in the pump–probe geometry using conventional optics. A phase-stabilized Michelson interferometer provides the pump-pulse delay interval,τ 1 , necessary to obtain the excitation-frequency dimension. Spectral resolution of the probe beam provides the detection-frequency dimension,ω 3 . The interferometer incorporates active phase stabilization via a piezo stage and feedback from interference of a continuous-wave reference laser detected in quadrature. To demonstrate the method, we measured a well-characterized laser dye sample and obtained the known peak structure. The vibronic peaks are modulated as a function of the waiting time,τ 2 , by vibrational wave packets. The interferometer simplifies ultrabroadband 2D ES measurements and analysis.

Optics↗

Understanding Type Ia Supernova Distance Biases by Simulating Spectral Variations

In the next decade, transient searches from the Vera C. Rubin Observatory and the Nancy Grace Roman Space Telescope will increase the sample of known Type Ia supernovae (SNe Ia) from ~10 3 to 10 5 . With this reduction of statistical uncertainties on cosmological measurements, new methods are needed to reduce systematic uncertainties. Here, characterizing the underlying spectroscopic evolution of SN Ia remains a major systematic uncertainty in current cosmological analyses, motivating a new simulation tool for the next era of SN Ia cosmology: Build Your Own Spectral Energy Distribution (byosed). byosed is used within the SNANA framework to simulate light curves by applying spectral variations to model SEDs, enabling flexible testing of possible systematic shifts in SN Ia distance measurements. We test the framework by comparing a nominal Roman SN Ia survey simulation using a baseline SED model to simulations using SEDs perturbed with byosed, and investigating the impact of ignoring specific SED features in the analysis. These features include semiempirical models of two possible, predicted relationships: between SN ejecta velocity and light-curve observables, and a redshift-dependent relationship between SN Hubble residuals and host-galaxy mass. We analyze each byosed simulation using the SALT2 and BEAMS with Bias Corrections framework, and estimate changes in the measured value of the dark-energy equation-of-state parameter, w. We find a difference of Δw = –0.023 for SN velocity and Δw = 0.021 for redshift-evolving host mass when compared to simulations without these features. By using byosed for SN Ia cosmology simulations, future analyses (e.g., the Rubin and Roman SN Ia samples) will have greater flexibility to constrain or reduce such SN Ia modeling uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Instance Segmentation for Direct Measurements of Satellites in Metal Powders and Automated Microstructural Characterization from Image Data

In this work, we propose instance segmentation as a useful tool for image analysis in materials science. Instance segmentation is an advanced technique in computer vision which generates individual segmentation masks for every object of interest that is recognized in an image. Using an out-of-the-box implementation of Mask R-CNN, instance segmentation is applied to images of metal powder particles produced through gas atomization. Leveraging transfer learning allows for the analysis to be conducted with a very small training set of labeled images. As well as providing another method for measuring the particle size distribution, we demonstrate the first direct measurements of the satellite content in powder samples. After analyzing the results for the labeled data dataset, the trained model was used to generate measurements for a much larger set of unlabeled images. The resulting particle size measurements showed reasonable agreement with laser scattering measurements. The satellite measurements were self-consistent and showed good agreement with the expected trends for different samples. Finally, we present a small case study showing how instance segmentation can be used to measure spheroidite content in the UltraHigh Carbon Steel DataBase, demonstrating the flexibility of the technique.

36 MATERIALS SCIENCE↗

Estimation of High-Altitude Electromagnetic Pulse Signal Leakage into Power Generation Facilities: Simulations and Measurements

The coupling of early-time high-altitude electromagnetic pulse signals into a power generation facility was investigated. This study encompasses both electromagnetic simulation and on-site experimental efforts that are relevant to shielding effectiveness estimation with a passive technique. As an initial step in understanding the attenuation models involved, simulations were carried out as a function of frequency, building properties, and signal incidence angle. Testing was then performed at the US Department of Energy’s Oak Ridge National Laboratory campus to identify the equipment needed for signal collection and to fine-tune the experimental procedure. Finally, as an application of the models and methods presented, measurements were conducted at a power generation plant to derive the field transfer functions and coupled high-altitude electromagnetic pulse waveforms for various locations within the facility.

42 ENGINEERING↗

Using X-ray spectrum imaging to quantify fission gas in high-burnup UO2 fuel

Analysis of fission gas bubbles (FGBs) in light-water reactor (LWR) fuel is needed to improve the understanding and predictive capability of fuel evolution under normal- and transient conditions. One of the most important parameters of a FGB is the pressure of the gas, primarily Xe, inside it. Bubble volume and location (inter- vs. intragranular) are important considerations as well. However, experimental analysis of such bubbles is challenging due to their small size and embedded nature, and usefulness of the data requires large numbers be analyzed. This paper proposes a method to measure the pressure of Xe bubbles using X-ray spectrum imaging (XSI) in scanning transmission electron microscopy (STEM). From X-ray generation and instrumental parameters, the number of Xe atoms yielding a given number of Xe L-series X-ray counts is estimated, and then from the estimated volume of the bubble the Xe density is estimated, which can then be converted to pressure via an equation-of-state. We apply the method to XSI datasets from high burnup (HBu) fuel from North Anna 1 reactor in as-irradiated and post-LOCA-test conditions and find Xe pressures in the FGBs clustered around 1 GPa.

Parish, Chad [ORNL] (ORCID:0000000312097439)↗

Measurement of elliptic flow of 𝐽/𝜓 in $\sqrt{s_{NN}}$ = 200 GeV ⁢Au + Au collisions at forward rapidity

Here, we report the first measurement of the azimuthal anisotropy of 𝐽/𝜓 at forward rapidity (1.2 < |𝜂| < 2.2) in Au + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV at the BNL Relativistic Heavy Ion Collider. The data were collected by the PHENIX experiment in 2014 and 2016 with integrated luminosity of 14.5 nb −1 . The second Fourier coefficient (𝑣 2 ) of the azimuthal distribution of 𝐽/𝜓 is determined as a function of the transverse momentum (𝑝𝑇) using the event-plane method. The measurements were performed for several selections of collision centrality: 0%–50%, 10%–60%, and 10%–40%. We find that in all cases the values of 𝑣 2 ⁡(𝑝 𝑇 ), which quantify the elliptic flow of 𝐽/𝜓, are consistent with zero. Within uncertainties, the results are consistent with measurements at midrapidity, indicating no significant elliptic flow of the 𝐽/𝜓 within the quark-gluon-plasma medium at collision energies of $\sqrt{s_{NN}}$ = 200 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Occupational and dietary differences in hydroxylated and methoxylated PBDEs and metals in plasma from Puget Sound, Washington, USA region volunteers

BACKGROUND: Electronic waste (E-waste) recycling is a rapidly growing occupation in the USA with the potential for elevated exposure to flame retardants and metals associated with electronic devices. We previously measured polybrominated diphenyl ethers (PBDEs) in plasma from E-waste workers and found them similar to non-E-waste workers. OBJECTIVES: This study focused on structurally related PBDE derivatives, the hydroxylated (OH-PBDEs) and methoxylated (MeO-PBDEs) forms along with metals known to occur in E-waste. Humans can metabolize PBDEs and some MeO-PBDEs into OH-PBDEs, which is a concern due to greater health risks associated with OH-PBDEs METHODS: We measured 32 different OH-PBDEs and MeO-PBDEs in plasma samples provided by 113 volunteers living in the greater Puget Sound region of Washington State, USA. We measured 14 metals in a subset of 10 E-waste and 10 non-E-waste volunteers. Volunteers were classified based on occupational and dietary habits: work outdoors and weekly consume = 5 seafood servings (outdoor), electronic waste recycling (E-waste) or non-specific indoor occupations (indoor). A two-week food consumption diary was obtained from each volunteer prior to blood sampling. RESULTS: OH-PBDEs were detected in all volunteers varying between 0.27 – 102 ng/g/g-lipid. The MeO-PBDEs were detected in most, but not all volunteers varying between 0 – 60.4 ng/g/g-lipid. E-waste recyclers had OH-PBDE and MeO-PBDE plasma levels that were similar to the indoor group. The outdoor group had significantly higher levels of MeO-PBDEs, but not OH-PBDEs. Comparison of plasma concentrations of BDE-47 with its known hydroxylated metabolites suggested OH-PBDE levels were likely determined by biotransformation and at least two subpopulations identified differing in their apparent rates of OH-PBDE formation. The metals analysis indicated no significant differences between E-waste workers and non-E-waste workers. CONCLUSIONS: Our results indicate E-waste workers do not have elevated plasma levels of these contaminants relative to non-E-waste workers with similar dietary habits.

Schultz, Irvin↗

Extension of Complex Refractive Index Measurements to the Near-Infrared for Liquids: Methodology and Uncertainty Analysis

Optical identification of liquid droplets, aerosols, or thin films is important for many applications. While reference spectra are sometimes available for such measurements, they are not always applicable to the observed spectrum or the given sample morphology. Reference spectra for many forms can be modeled, however, if the n/k vectors (real and imaginary refractive indices) are available. In previous work we have reported protocols to determine the n/k vectors for dozens of liquids, primarily in the mid-infrared (MIR) spectral range from 7500 to 400 cm –1 . In this work we extend the spectral range into the near-infrared (NIR) region, demonstrating a method to measure and merge the data sets to create composite n/k data ranging from 10 000 to 400 cm –1 (1.0 to 25 µm) with absorbance fidelity spanning over four orders of magnitude, and vastly improved signal-to-noise in the NIR. The precision of the composite data is evaluated for three different liquids, focusing primarily on the steps for converting the raw absorbance spectra to k values. The variability in both MIR and NIR data as well as in the final n/k vectors is also investigated for several liquids. For typical liquids, the overall variability (reported as 2σ) in the final n and k-vectors is determined to be ∼0.4% and 3%, respectively. Finally, the derived n/k data are used to calculate absorbance spectra for aerosol droplets, showing marginal variability due to the typical measurement errors in the final n/k vectors.

47 OTHER INSTRUMENTATION↗

Development of an ERT‐Based Framework for Bentonite Buffers Monitoring From Laboratory Tests: 1. Characterizing Thermal–Hydrological–Mechanical Processes

Abstract Bentonite clay is widely used in engineered barrier systems for the permanent disposal of high‐level radioactive waste due to its low permeability, high swelling capacity, and thermal stability. However, the complex thermal‐hydrological‐mechanical (THM) processes induced by heating from decaying radioactive waste and hydration from surrounding rock can lead to heterogeneous changes that are difficult to measure and predict. This study develops an Electrical Resistivity Tomography (ERT)‐based framework for monitoring THM processes, progressing from sample‐scale to bench‐scale tests, to inform field‐scale applications. Sample‐scale tests analyzed small bentonite samples under controlled variations in water content, temperature, and porosity to establish fundamental resistivity relationships. Bench‐scale tests involved larger bentonite columns subjected to heating (up to 200°C) and hydration under controlled pressure, simulating repository conditions. ERT measurements, complemented by X‐ray CT imaging, temperature monitoring, and tracing sensors, revealed coupled THM processes, such as hydration‐induced compression, swelling, and thermal gradients, leading to complex resistivity patterns. The results demonstrate the potential of ERT for capturing THM‐induced resistivity changes, though challenges remain in upscaling and quantitative analysis. This study evaluates laboratory test capabilities and proposes future improvements for understanding THM‐induced resistivity responses. A conceptual framework for ERT implementation in field‐scale monitoring is presented, synthesizing findings from both scales and exploring how ERT data can inform long‐term modeling and reduce prediction uncertainties. Overall, this ERT‐based framework offers a robust method for monitoring bentonite buffers, aiding in early issue detection and supporting the safe long‐term disposal of radioactive waste in geological repositories, while highlighting the need for future development. Plain Language Summary Bentonite clay is crucial in engineered barrier systems (EBS) for containing high‐level radioactive waste due to its ability to absorb water, swell, seal and remain stable under high temperatures. When bentonite absorbs water and heats up from radioactive decay, it experiences complex changes in its physical and mechanical properties. Understanding these changes is important for ensuring the long‐term safety and effectiveness of EBS. This study used Electrical Resistivity Tomography (ERT), a non‐invasive method that measures electrical conductivity to monitor these changes during laboratory experiments. The ERT data revealed significant variations in resistivity corresponding to changes in water content, temperature, and density, providing detailed spatial and temporal insights into the behavior of bentonite. These findings enhance our ability to predict the long‐term performance of bentonite barriers, ensuring the safe containment of radioactive waste. By improving our understanding of bentonite's behavior, this research supports the development of more reliable and effective barrier systems for radioactive waste disposal, protecting the environment and public health. Key Points ERT monitoring was employed to capture resistivity changes in bentonite during controlled heating and hydration experiments, providing insights into THM processes ERT data reveal significant resistivity changes correlated with water content, temperature, and mechanical effects, enhancing the understanding of THM dynamics in bentonite This study explores the potential of the framework for application in field‐scale EBS monitoring, emphasizing the need for integrating additional geophysical methods for comprehensive subsurface imaging

Chen, Hang↗

CI-MBPT and Intensity-Based Lifetime Calculations for Th II

Lifetime calculations of Th II J = 1.5 and 2.5 odd states are performed with configuration–interaction many-body perturbation theory (CI-MBPT). For many J = 2.5 states, lifetimes are quite accurate, but two pairs of J = 2.5 odd states and many groups of J = 1.5 states are strongly mixed, making theoretical predictions unreliable. To solve this problem, a method based on intensities is used. To relate experimental intensities to lifetimes, two parameters, one an overall coefficient of proportionality for transition rates and one temperature of the Boltzmann distribution of populations, are introduced and fitted to minimize the deviation between theoretical and intensity-derived lifetimes. For strongly mixed groups of states, the averaged lifetimes obtained from averaged transition rates were used instead of individual lifetimes in the fit. Close agreement is obtained. Then intensity branching ratios are used to extract individual lifetimes for the strongly mixed states. The resulting lifetimes are compared to available directly measured lifetimes and reasonable agreement is found, considering limited accuracy of intensity measurements. The method of intensity-based lifetime calculations with fit to theoretical lifetimes is quite general and can be applied to many complex atoms where strong mixing between multiple states exists.

74 ATOMIC AND MOLECULAR PHYSICS↗

Infrared quantum ghost imaging of living and undisturbed plants

Quantum ghost imaging (QGI) is a method that measures absorption at extremely low light intensities. Nondegenerate QGI probes a sample at one wavelength while forming an image with correlated photons at a different wavelength. This spectral separation alleviates the need for imaging detectors with high sensitivity in the near-infrared (NIR) region, thereby reducing the required illumination intensity. Using NCam, a single-photon detector, we demonstrated nondegenerate QGI with unprecedented sensitivity and contrast, obtaining images of living plants with less than 1% light transmission. The plants experienced 3aW/cm 2 of light during imaging, orders of magnitude below starlight. This realization of QGI expands the method to extremely low-light bioimaging and imaging of light-sensitive samples, where minimizing illumination intensity is crucial to prevent phototoxicity or sample degradation.

47 OTHER INSTRUMENTATION↗

Apparatus for measuring strength in biaxial compression

We report most measurements of compressive strength of ductile materials have involved Hopkinson–Kolsky bars or Taylor anvils placing samples in uniaxial compression. In these geometries, strain is limited by the tendency of the sample to petal, in analogy to necking in uniaxial tension. Estimation of strength for any other form of the stress tensor requires assuming a shape of the yield surface; because data exist only for uniaxial compression, these assumptions are untested. In an imploding spherical shell, compression is biaxial, the plastic strain may not be small, and the material behavior may be nonlinear as a result of work hardening and heating by plastic work. We outline a method of measuring the strengths of materials in biaxial compression, both quasistatically and dynamically, using the compression of thin spherical shells. We suggest surrounding the shell with an annulus filled with a mixture of H 2 and Cl 2 gases whose homogeneous ignition is initiated by a flash of blue and near-ultraviolet light. Less promising approaches are described in Appendixes A–C .

47 OTHER INSTRUMENTATION↗

Fast and Non-Destructive Determination of Water Content in Ionic Liquids at Varying Temperatures by Raman Spectroscopy and Multivariate Regression Analysis

Imidazolium acetate ionic liquids (ILs) have been utilized as promising solvents in many applications that involve varying water content and temperature. These experimental variables affect the anion-cation intermolecular interactions, which in turn influence the performance of the ILs in these applications. Here, this paper shows Raman spectroscopy can be used as an operando method to measure water content in IL solvents when simultaneous temperature changes may occur. The Raman spectra of 1-alkyl-3-methylimidazolium acetate ILs (alkyl chain length n = 2, 4, 6, 8) with varying water content (from 0.028 to 0.899 water mole fraction) and temperature (from 78.1 K to 423.1 K) were measured. Increasing the water content or decreasing the temperature of the tested ILs weakens the anion-cation intermolecular interactions. The water content of these ILs can be quantified even in conditions when the temperature is changing using Raman spectroscopy combined with multivariate regression analysis, including principal component regression (PCR), partial-least-squares regression (PLSR), and artificial neural networks (ANNs). The ANN model combined with partial-least-squares (PLS) achieves the highest prediction accuracy of water content in ILs at varying temperatures (RMSECV = 0.017, R 2 CV = 99.1%, RMSEP = 0.019, R 2 P = 98.8%, RPD = 8.93). Raman spectroscopy provides a potential fast non-destructive operando method to monitor the water content of ILs even in applications when the temperature may be simultaneously altered; this information can lead to the optimized use of these ILs in many applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systems, methods and tools for subterranean electrochemical characterization and enthalpy measurement in geothermal reservoirs

The present disclosure is directed to systems, methods and tools that measure ionic concentrations and downhole enthalpy of a flowing geothermal fluid in real-time at high-temperature and pressure. The systems, methods and tools include measuring the concentration of selected naturally occurring ions found in the liquid phase of the geothermal fluid throughout the wellbore using novel electrochemical sensor technologies. The change in liquid-phase ion concentration will be used to calculate the proportion of liquid to steam and allow for accurate enthalpy measurements. The techniques and technologies described here can be applied to any application of electrochemical sensing in extreme environments.

Cieslewski, Grzegorz↗