Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONOCHROMATIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Y and Z luminescence of polycrystalline cadmium telluride grown by a nonequilibrium reaction of the direct synthesis of components

Microphotoluminescence methods of spectral analysis and topography are used to study the properties of polycrystalline CdTe with grain size 10-20 {mu}m; the polycrystals were grown by a nonequilibrium reaction of direct synthesis in the vapor flow of components at a relatively low temperature. The presence of the Y and Z bands in the luminescence spectra was indicative of clearly nonequilibrium types of crystallization processes. Superlinear dependences of the intensities of these bands on the level of the band-to-band excitation, unusually weak electron-phonon interaction, and also data of monochromatic microluminescence topography correspond to the model of radiation of excitons bound by delocalized potential at various extended defects (elements of dislocations, lamellas twins, and packing faults) generated in the studied samples by the concentration and thermal fluctuations at growth surface as a result of dynamic instabilities in the vapor phase in the crystallization zone.

36 MATERIALS SCIENCE↗

HARD X-RAYS AS A DIAGNOSTIC TOOL FOR WARM DENSE MATTER

We present the application of short-pulse laser-driven hard x-rays (>40 keV) for the direct density measurement of iron compressed by a laser-driven shock. By using an on-shot calibration of the line density, we are able to obtain line densities even though the x-ray source is not monochromatic. The consequences for the line density measurement using a polychromatic source are discussed in detail, as well as the calibration method we propose to solve this problem.

07 ISOTOPE AND RADIATION SOURCES↗

Correlation spectrometer having high resolution and multiplexing capability

A correlation spectrometer permanently incorporates a reference cell and an electro-optical phase modulator (EOPM) in the light path between a sample cell and a detector. The effect of the EOPM is such that its frequency modulates all of the monochromatic component of the incoherent radiation passing through it. The EOPM is adjusted so that when it is ON all of the energy in the monochromatic components is thrown into sidebands differing from the original frequencies by integral multiples of the modulation frequency with the total amount of energy absorbed from the original radiation remaining constant. When there is no coincidence between the constituents in the two cells, the detector's output is the same when the EOPM is ON and when it is OFF. However, when there is coincidence the detector's output changes when the EOPM is switched between its two states. The change in the detector's output is related to the quantity of the constituents in the sample cell.

Margolis, J. S.↗

Probing the inert doublet dark matter model with Cherenkov telescopes

We present a detailed study of the annihilation signals of the inert dark matter doublet model in its high mass regime. Concretely, we study the prospects to observe gamma-ray signals of the model in current and projected Cherenkov telescopes taking into account the Sommerfeld effect and including the contribution to the spectrum from gamma-ray lines as well as from internal bremsstrahlung. We show that present observations of the galactic center by the H.E.S.S. instrument are able to exclude regions of the parameter space that give the correct dark matter relic abundance. In particular, models with the charged and the neutral components of the inert doublet nearly degenerate in mass have strong gamma-ray signals. Furthermore, for dark matter particle masses above 1 TeV, we find that the non-observation of the continuum of photons generated by the hadronization of the annihilation products typically give stronger constraints on the model parameters than the sharp spectral features associated to annihilation into monochromatic photons and the internal bremsstrahlung process. Lastly, we also analyze the interplay between indirect and direct detection searches for this model, concluding that the prospects for the former are more promising. In particular, we find that the upcoming Cherenkov Telescope Array will be able to probe a significant part of the high mass regime of the model.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal radiation from optically driven Kerr (χ{sup (3)}) photonic cavities

We describe thermal radiation from nonlinear (χ{sup (3)}) photonic cavities coupled to external channels and subject to incident monochromatic light. Our work extends related work on nonlinear mechanical oscillators to the problem of thermal radiation, demonstrating that bistability can enhance thermal radiation by orders of magnitude and result in strong lineshape alternations, including “super-narrow spectral peaks” occurring at the onset of kinetic phase transitions. We show that when the cavities are designed to exhibit perfect linear emissivity (rate matching), such thermally activated transitions can be exploited to dramatically tune the output power and radiative properties of the cavity, leading to a kind of Kerr-mediated thermo-optic effect. Finally, we demonstrate that in certain parameter regimes, the output radiation exhibits Stokes and anti-Stokes side peaks whose relative magnitudes can be altered by tuning the internal temperature of the cavity relative to its surroundings, a consequence of strong correlations and interference between the emitted and reflected radiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Invited Review Article: Development of crystal lenses for energetic photons

This paper follows the development of crystal diffraction lenses designed to focus energetic photons. It begins with the search for a solution to the astrophysics problem of how to detect weak astrophysics sources of gamma rays and x-rays. This led to the basic designs for a lens and to the understanding of basic limitations of lens design. The discussion of the development of crystal diffraction lenses is divided into two parts: lenses using crystals with mosaic structure, and lenses that use crystals with curved crystal planes. This second group divides into two sub-groups: (1) Curved crystals that are used to increase the acceptance angle of the diffraction of a monochromatic beam and to increase the energy bandwidth of the diffraction. (2) Curved crystals used to focus gamma ray beams. The paper describes how these two types of crystals affect the design of the corresponding crystal lenses in different fields: astrophysics, medical imaging, detection of weak, distant, gamma-ray sources, etc. The designs of crystal lenses for these applications are given in enough detail to allow the reader to design a lens for his own application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing optical chirality

We examine the recently introduced measure of chirality of a monochromatic optical field [Y. Tang and A. E. Cohen, Phys. Rev. Lett. 104, 163901 (2010)] using the momentum (plane-wave) representation and helicity basis. Our analysis clarifies the physical meaning of the measure of chirality and unveils its close relation to the polarization helicity, spin angular momentum, energy density, and Poynting energy flow. We derive the operators of the optical chirality and of the corresponding chiral momentum, which acquire remarkably simple forms in the helicity representation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Negative magnetoresistance in silicon with manganese-atom complexes [Mn]{sub 4}

It is experimentally shown that an anomalously high negative magnetoresistance is observed in silicon with manganese-atom complexes [Mn]{sub 4} at room temperature. It is established that the negative magnetoresistance has the largest value at T = 230-240 K, while its value decreases with temperature, and the inversion of the magnetoresistance sign takes place at T < 170 K; i.e., the positive magnetoresistance is observed. It is established that the negative magnetoresistance and its temperature dependence are substantially affected by the intensity of both integrated and monochromatic light.

36 MATERIALS SCIENCE↗

Role of transient processes in resonance line spectroscopy of caesium atoms in cells with antirelaxation coating

We study the peculiarities of the absorption spectra in D{sub 1,2}-lines of Cs, caused by optical pumping in cells with antirelaxation coating. In these cells the internal state of the atom, which arose under optical pumping by a monochromatic laser field, is preserved with a high probability in a collision with the wall. As a result, the optical pumping action extends to the entire volume of the cell and to all the velocities of the atoms. This leads to the speed-dependent scanning distortions of the absorption line profile. The detected features should be considered when using laserpumped quantum magnetometers with antirelaxation-coated cells. (laser spectroscopy)

74 ATOMIC AND MOLECULAR PHYSICS↗

Microfocus/Polycapillary-Optic Crystallographic X-Ray System

A system that generates an intense, nearly collimated, nearly monochromatic, small-diameter x-ray beam has been developed for use in macromolecular crystallography. A conventional x-ray system for macromolecular crystallography includes a rotating-anode x-ray source, which is massive (.500 kg), large (approximately 2 by 2 by 1 m), and power-hungry (between 2 and 18 kW). In contrast, the present system generates a beam of the required brightness from a microfocus source, which is small and light enough to be mounted on a laboratory bench, and operates at a power level of only tens of watts. The figure schematically depicts the system as configured for observing x-ray diffraction from a macromolecular crystal. In addition to the microfocus x-ray source, the system includes a polycapillary optic . a monolithic block (typically a bundle of fused glass tubes) that contains thousands of straight or gently curved capillary channels, along which x-rays propagate with multiple reflections. This particular polycapillary optic is configured to act as a collimator; the x-ray beam that emerges from its output face consists of quasi-parallel subbeams with a small angular divergence and a diameter comparable to the size of a crystal to be studied. The gap between the microfocus x-ray source and the input face of the polycapillary optic is chosen consistently with the focal length of the polycapillary optic and the need to maximize the solid angle subtended by the optic in order to maximize the collimated x-ray flux. The spectrum from the source contains a significant component of Cu K (photon energy is 8.08 keV) radiation. The beam is monochromatized (for Cu K ) by a nickel filter 10 m thick. In a test, this system was operated at a power of 40 W (current of 897 A at an accelerating potential of 45 kV), with an anode x-ray spot size of 41+/-2 microns. Also tested, in order to provide a standard for comparison, was a commercial rotating-anode x-ray crystallographic system with a pyrolytic graphite monochromator and a 250-micron pinhole collimator, operating at a power of 3.15 kW (current of 70 mA at an accelerating potential of 45 kV). The flux of collimated Cu K radiation in this system was found to be approximately 16 times that in the rotatinganode system. Data on x-ray diffraction from crystals of tetragonal form of lysozyme (protein) in this system were found to be of high quality and to be reducible by use of standard crystallographic software.

Joy, Marshall↗

Dipole spectrum structure of nonresonant nonpertubative driven two-level atoms

We analyze the dipole spectrum of a two-level atom excited by a nonresonant intense monochromatic field under the electric dipole approximation and beyond the rotating wave approximation. We show that the apparently complex spectral structure can be completely described by two families: harmonic frequencies of the driving field and field-induced nonlinear fluorescence. Our formulation of the problem provides quantitative laws for the most relevant spectral features: harmonic ratios and phases, nonperturbative Stark shift, and frequency limits of the harmonic plateau. In particular, we demonstrate the locking of the harmonic phases at the wings of the plateau opening the possibility of ultrashort pulse generation through harmonic filtering.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dual energy phase contrast x-ray imaging with Talbot-Lau interferometer

In weakly absorbing materials such as polymers and soft tissue, x-ray phase sensitive imaging methods can provide substantially enhanced contrast compared to classical, absorption based radiography. For specific applications, the latter can be applied in a dual energy scheme that helps to identify, discriminate and/or quantify materials. In this paper, we report on a new method that combines the idea of dual energy with x-ray phase contrast imaging and thus provides material sensitivity among poor absorbers. The dual energy modality cannot be applied in common phase contrast imaging schemes because of their demand for limited bandwidth or even monochromatic x-ray sources. Our new interferometric method based on diffraction gratings can overcome this shortcoming and thus simultaneously deliver x-ray phase contrast images for two distinct x-ray energy intervals. It has been shown that high quality images can be obtained with the dual energy phase setup. Energy spectra with 40 kV and 70 kV were applied to obtain low- and high-energy images, respectively. Furthermore, an estimation of the effective energy in the image formation process for absorption and phase contrast was experimentally determined. Examples are shown for which the dual energy phase contrast modality delivers complementary information on material composition when compared with the conventional dual energy scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Intense laser field effects on p-d exchange interaction in single manganese doped GaAs

We have developed a comprehensive theory about optical control of p - d exchange interaction between spins of hole and Mn{sup 2+} in single-manganese doped GaAs material irradiated by a monochromatic, linearly polarized, intense pulsed laser field (PLF) under nonresonant conditions. The p - d exchange interaction leads to formation of magnetic polaron. While the PLF induces a dressed acceptor Coulomb potential, which transforms single center problem into the one with two virtual positively charged centers, resembling hydrogen molecule ion (H{sub 2}{sup +}). The dichotomy of hole wave functions, determined by the laser-intensity, affects strongly the p - d exchange interaction as well as binding energy of magnetic polaron. Increasing the laser intensity reduces the magnetic polaron binding energy. At larger excitation intensity, the magnetic polaron can be completely dissolved.

36 MATERIALS SCIENCE↗

Disk and circumsolar radiances in the presence of ice clouds

The impact of ice clouds on solar disk and circumsolar radiances is investigated using a Monte Carlo radiative transfer model. The monochromatic direct and diffuse radiances are simulated at angles of 0 to 8° from the center of the sun. Input data for the model are derived from measurements conducted during the 2010 Small Particles in Cirrus (SPARTICUS) campaign together with state-of-the-art databases of optical properties of ice crystals and aerosols. For selected cases, the simulated radiances are compared with ground-based radiance measurements obtained by the Sun and Aureole Measurements (SAM) instrument. First, the sensitivity of the radiances to the ice cloud properties and aerosol optical thickness is addressed. The angular dependence of the disk and circumsolar radiances is found to be most sensitive to assumptions about ice crystal roughness (or, more generally, non-ideal features of ice crystals) and size distribution, with ice crystal habit playing a somewhat smaller role. Second, in comparisons with SAM data, the ice cloud optical thickness is adjusted for each case so that the simulated radiances agree closely (i.e., within 3 %) with the measured disk radiances. Circumsolar radiances at angles larger than ≈ 3° are systematically underestimated when assuming smooth ice crystals, whereas the agreement with the measurements is better when rough ice crystals are assumed. In conclusion, our results suggest that it may well be possible to infer the particle roughness directly from ground-based SAM measurements. In addition, the results show the necessity of correcting the ground-based measurements of direct radiation for the presence of diffuse radiation in the instrument's field of view, in particular in the presence of ice clouds.

54 ENVIRONMENTAL SCIENCES↗

Analytic description of high-order harmonic generation by atoms in a two-color laser field

A closed-form analytic formula describing high-order harmonic generation (HHG) in a two-color field of frequencies {omega} and 2{omega} is derived quantum mechanically in the low-frequency (tunneling) limit for an electron bound by a short-range potential and generalized to the case of an active electron in a neutral atom. The HHG rates are presented as a product of an electron wave packet describing the ionization of an active electron and its propagation in a laser field up to the recombination event and an atom-specific cross section of the electron's photorecombination. In contrast to the case of a monochromatic laser pulse [Frolov et al., Phys. Rev. Lett. 102, 243901 (2009)], the two-color wave packet involves the interference of two terms (involving the Airy function) that describe the emission of harmonics during the first and second half-cycles of the fundamental laser cycle and give rise to the two-plateau structures in the HHG spectra. For the case of the H atom, we show that our analytic results are in good agreement with those obtained from a numerical solution of the three-dimensional time-dependent Schroedinger equation. The factorization formula is used for describing the dependence of HHG rates for inert gases on the relative phase and intensities of the {omega} and 2{omega} components of a laser field. It is shown that atomic structure (including electron correlation) effects can modify substantially the two-color HHG spectra of inert gases.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hunting dark matter gamma-ray lines with the Fermi LAT

Monochromatic photons could be produced in the annihilation or decay of dark matter particles. At high energies, the search for such line features in the cosmic gamma-ray spectrum is essentially background free because plausible astrophysical processes are not expected to produce such a signal. The observation of a gamma-ray line would hence be a 'smoking-gun' signature for dark matter, making the search for such signals particularly attractive. Among the different dark matter models predicting gamma-ray lines, the local supersymmetric extension of the standard model with small R-parity violation and gravitino LSP is of particular interest because it provides a framework where primordial nucleosynthesis, gravitino dark matter and thermal leptogenesis are naturally consistent. Using the two-years Fermi LAT data, we present a dedicated search for gamma-ray lines coming from dark matter annihilation or decay in the Galactic halo. Taking into account the full detector response, and using a binned profile likelihood method, we search for significant line features in the energy spectrum of the diffuse flux observed in different regions of the sky. No evidence for a line signal at the 5σ level is found for photon energies between 1 and 300 GeV, and conservative bounds on dark matter decay rates and annihilation cross sections are presented. Implications for gravitino dark matter in presence of small R-parity violation are discussed, as well as the impact of our results on the prospect for seeing long-lived neutralinos or staus at the LHC.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation and simulation of hard x ray photoelectron diffraction to determine polarity of polycrystalline zinc oxide films with rotation domains

X ray photoelectron diffraction (XPD) patterns of polar zinc oxide (ZnO) surfaces were investigated experimentally using hard x rays and monochromatized Cr K{alpha} radiation and theoretically using a cluster model approach and a dynamical Bloch wave approach. We focused on photoelectrons emitted from the Zn 2p{sub 3/2} and O 1s orbitals in the analysis. The obtained XPD patterns for the (0001) and (0001) surfaces of a ZnO single crystal were distinct for a given emitter and polarity. Polarity determination of c-axis-textured polycrystalline ZnO thin films was also achieved with the concept of XPD, even though the in-plane orientation of the columnar ZnO grains was random.

36 MATERIALS SCIENCE↗

Pushing data quality for laboratory pair distribution function experiments

Over the past decade, some studies with laboratory pair distribution function (PDF) data emerged. Yet, limited Q max or instrumental resolution impeded in-depth structural refinements. With more advanced detector technologies, the question arose how to design novel PDF equipment for laboratories that will allow decent PDF refinements over r = 1–70 Å. It is crucial to reflect the essential requirements, namely, monochromatic X-rays, suppression of air scattering, instrumental resolution, and overall measurement times. The result is a novel PDF setup based on a STOE STADI P powder diffractometer in transmission-/Debye-Scherrer geometry with monochromatic Ag Kα 1 radiation, featuring a MYTHEN2 4K detector covering a Q range of 0.3–20.5 Å –1 . PDF data are collected in a moving PDF mode within 6 h. Structural signatures of liquids can be satisfactorily resolved in the PDF as shown for the ionic liquid hmimPF 6 . The high instrumental resolution is mirrored in low q damp values determined from LaB 6 measurements. PDF data from a powder sample of ca. 7 nm TiO 2 nanoparticles were successfully refined over up to 70 Å with goodness-of-fit values R w < 0.22 (respectively R w = 0.18 over 30 Å), thanks to the low background and high instrumental resolution, hereby enlarging the accessible r range by several tens of Angstroms compared to previous laboratory PDF studies.

47 OTHER INSTRUMENTATION↗